Macs 10 Multi parameter patient monitor www.sternmed.de

Transcript of Macs 10 - test-ibscg.com

Page 1: Macs 10 - test-ibscg.com

www.sternmed.de

Macs 10Multi parameter patient monitor

www.sternmed.de

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2
Page 2: Macs 10 - test-ibscg.com

The Macs 10 is an affordable compact portable patient monitor with essen-tial basic parameters such as ECG, RESP, temperature, SPO2 and NIBP.

Macs 10Multi parameter patient monitor

© SternMed2

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2
Page 3: Macs 10 - test-ibscg.com

FEATURES

• 7” high resolution color TFT screen

• 5 or 7-channelwaveform display with trend coexistence, switchable to observing screen

• Automatic analysis of 20 arrhythmia waveforms

• S-T segment with automatic & manual analysis

• Monitoring standard parameters of ECG, Spo2, RESP, NIBP, TEMP & PR

• Optimized modes for adult, pediatric & neonate

• DigitalSpo2 technology with anti-motion & anti-low infusion

© SternMed3

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2
Page 4: Macs 10 - test-ibscg.com

• Trend data analysis for 6/24/120/480 hours

• Store & review 800 groups of NIBP list data & 24-hour ECG waveforms

• Audio and Visual alarms with 3-level classification

• Protection against interference from defibrillator & electrosurgical unit

• Removable rechargeable battery

• Network capability (optional)

© SternMed4

IBSCGMED-CPTA
Bas_de_page
stagiaire
Logo-2
Page 5: Macs 10 - test-ibscg.com

Monitoring mode: 0.5-40HzDiagnosis mode: 0.05-75Hz>89dB20-300bpm+1% or +2bpm, whichever is greater1/2 5mm/mV@+5%1 10mm/mV@+5%2 20mm/mV@+5%12.5mm/s, 25mm/s, 50mm/s@+10%

Intelligent oscillometric methodSystolic, diastolic & mean pressureManual, automatic & STAT (5 minutes)0-300 mmHgAdult (standard)Child/neonate (standard)<90sec<10sec (typical adult cuff)<2sec (typical adult cuff)Systolic 40-275mmHg | Mean 20-230mmHg | Diastolic 10-210mmHgSystolic 40-200mmHg | Mean 20-165mmHg | Diastolic 10-150mmHgSystolic 40-135mmHg | Mean 20-110mmHg | Diastolic 10-95mmHg300mmHg240mmHg150mmHgMaximum mean error +5 mmHgMaximum standard deviation 8 mmHg

Thoracic Impedance0-120bpm+5% or +2bom, whichever is greater0-120bpm

25.0-45.0·C+0.2°C< 150sec

Dual-wavelength LED35-100%+3% (50-100%) (RMS of difference)0.4-5%30bpm-240bpm+2% or +2bpm, whichever is greater

100-240VAC, 50/80Hz7 inches TFT color LCDAudible & visible alarmEthernet portRechargeable lithium battery

IEC 60601-1Type BF, CF applied partsClass I equipmentGroup I, Class B

ECGECG Amplifier Bandwidth

CMRRHeart Rate Range Accuracy ECG Gain

ECG Sweeping SpeedNIBPMeasurement MethodParametersWorking ModesPneumatic Pressure RangeCuff Type

Average Measurement TimeInflation TimeDeflation TimeMonitoring Range Adult Child Neonate Overpressure Protection Limit Adult Child NeonateNIBP Accuracy

RESPMeasurement MethodMeasurement RangeAccuracyAlarm Limit RangeTEMPRangeAccuracyResponding TimeSPO2

TransducerSpO2 Measuring RangeSpO2 Measuring RangeLow Perfusion CapabilityPulse rate Measuring RangeAccuracy of Pulse RateGENERAL SPECIFICATIONSPower SupplyDisplay ModeAlarming ModeCommunicationBatteryCLASSIFICATIONSafety StandardType of Protection Against Electric ShockDegree of Protection Against Electric ShockElectro-Magnetic Compatibility

© SternMed5