For technical assistance call 866-357-8832 MA50777-MNL_revN MOTION ACCESS , LLC automatic entrance solutions Installation & Operation Manual CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove Village, IL 60007 847-357-8832 toll free: 866-357-8832 fax: 847-357-8834 www.MotionAccess.com [email protected]

Transcript of MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For...

Page 1: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

For technical assistance call 866-357-8832 MA50777-MNL_revN

MOTIONACCESS, LLCautomatic entrance solutions

Installation & Operation Manual

CONDOR SWING MA50777 Swing Control

For Motion Access Condor Swing Operators

MotionAccess, LLC 775 Nicholas Blvd.

Elk Grove Village, IL 60007

847-357-8832

toll free: 866-357-8832

fax: 847-357-8834

www.MotionAccess.com

[email protected]

Page 2: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

2 For technical assistance call 866-357-8832 MA50777-MNL_revP1

IMPORTANT INSTALLATION INSTRUCTIONS WARNING – To reduce the risk of severe injury or death: 1) READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2) Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to pivots, and other hardware before installing the operator. 3) Remove all manual closers that are connected to the door before installing the operator. 4) Do not connect the door operator to the source of power until instructed to do so. 5) If being used, locate the control station: (a) within sight of the door, (b) away from all moving parts of the door. 6) Never let children operate or play with door controls. Keep the remote control (where provided) away from children. 7) Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. 8) Test the door’s safety features once a day. Have a trained door systems technician make any adjustments to the opening or closing speeds and retest the door operator’s safety features. Failure to adjust the operator properly may cause severe injury or death. 9) KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer’s Owner’s Manual. An improperly operating or balanced door could cause severe injury or death. Have a trained door systems technician make repairs to pivots, and other hardware. 10) This operator is intended for indoor use only. 11) Use Copper, Copper-Clad Aluminum, or Aluminum Conductors when making connections to this operator. 12) SAVE THESE INSTRUCTIONS.

Page 3: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

3 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section A: Installation Instructions

! DANGER: This controller must be adjusted to ANSI/BHMA A156.10 and

A156.19 standards by a qualified person. Unsafe operation may result if standards are not met.

! DANGER: Never attempt uses which are not covered in this manual.

Serious injury or death may result.

! WARNING: Controller may already be set to High Energy if requested at

time of order, or if the cover seal is broken. See item 8 for details.

1. Ensure dedicated power (120VAC, 50/60HZ, 10A).

2. Ensure power is not shared with other equipment.

3. Main power into the header must be de-energized before making connections.

4. Incoming power wires should be connected per local codes and then connected to the power harness inside the header (see “Wiring Diagram” on last page). a. Black – Line (Hot) b. White – Neutral c. Green – Ground (earth ground)

! WARNING: Supply earth ground should be connected to the green

ground screw inside the operator header. Severe injury or death may result if ground wire is not properly connected.

5. Install required equipment into the door opening (safety sensors, activation sensors, beams, switches, electric lock etc.).

! DANGER: Connections are safety critical. Ensure wires are fastened

securely in terminal blocks.

6. Strip 3/8” off of wire ends and make connections to controller ensuring proper wire engagement. Do not connect the power harness at this time. Make all terminal block connections. Reference the attached table “Wiring Inputs at Terminal Block” for description of terminal usage and the attached “Wiring Diagram” for wire routing.

Depress tab completely before inserting wire

Terminal block

Insert wire here & pull lightly to check engagement

Page 4: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

4 For technical assistance call 866-357-8832 MA50777-MNL_revP1

7. Connect the motor harness to the controller’s M1 connector. If using two operators, connect the slave unit using the slave “extension” harness to the M2 connector.

8. Select appropriate program for the application. See the attached “Program Selector” table in the “Controller Settings & Adjustments” section for details.

Operation Program

Low Energy 0 thru 5 012 3 4

65

A987

FED CB High Energy A thru D

! WARNING: Controller may already be set to High Energy if requested at

time of order, or if the cover seal is broken.

Internal jumper J2 must be in the correct position to permit High Energy programs. All units are shipped as Low Energy unless specifically requested to be High Energy. See the attached section “Controller Settings & Adjustments” for details.

! DANGER: When using High Energy programs, appropriate safety

equipment must be in place. See ANSI/BHMA A156.10 and A156.19 standards.

9. Select DIP switches. See the attached “DIP Switch Settings” table in “Controller Settings & Adjustments” section for details.

on

off

1 2 3 4 DIP Switches

Available Option “ON”

DIP Switch Low Energy

Low Energy / Low Force

High Energy

Power Boost 1 & 2 Yes No Yes

Electric Lock & Delay 3 Yes Yes Yes

Push & Go 4 Yes Yes No

Safety Stop (normally Safety Slow)

4 No No Yes

! DANGER: Doors should be set up according to ANSI/BHMA A156.10 and

A156.19 standards and any other applicable standards.

Page 5: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

5 For technical assistance call 866-357-8832 MA50777-MNL_revP1

10. Install control box into header ensuring wires are not pinched, rotate retaining wings into the header groove and tighten screws.

! DANGER: Never modify harnesses. Unsafe operation may result. For

technical assistance call MotionAccess 847-357-8832.

! DANGER: Stay clear of doors and keep fingers and hands way from

moving parts. The door may activate unexpectedly when power is restored.

! DANGER: Route harnesses away from moving parts & sharp edges.

11. Ensure you and others are clear of door(s) and mechanism.

12. Connect power harness to controller and restore main power.

13. Provide a continuous activation signal to the control; or set the jamb/function switch to “Hold Open” if available. The spindle will rotate to the full open position.

14. Attach arm to spindle and door (see instructions provided with arm). Stay clear of the arms closing path as the loss of the activation signal or power will cause the arm to swing quickly towards the closed position.

retaining wing

Page 6: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

6 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section B: Adjustment Instructions

! DANGER: This controller must be adjusted to ANSI/BHMA A156.10 and

A156.19 standards by a qualified person. Unsafe operation may result if standards are not met.

! DANGER: Never attempt uses which are not covered in this manual.

Serious injury or death may result.

15. Allow the door to close by removing the activation signal or set the jamb/function switch to “Auto”.

16. Reset the controller by momentarily disconnecting power and then restoring power.

17. Activate the system and the door will go through one sizing cycle. The door can be activated by momentarily jumpering the activation terminals 16 and 17 (see “Wiring Diagram”). Or, the door can also be activated by pushing the door slightly open.

18. Always wait 5 seconds before reactivating after a sizing cycle.

19. Using the thumb-turn potentiometers, adjust the door operation. See the attached “Potentiometer Adjustments” table in the “Controller Settings & Adjustments” section for details. Doors should be adjusted to ANSI/BHMA A156.10 and A156.19 standards and any other applicable standards.

! DANGER: This controller must be adjusted to ANSI/BHMA A156.10 and

A156.19 standards by a qualified person.

! DANGER: Complete a walk through test. Refer to the latest version of

ANSI/BHMA A156.10 and A156.19 for proper door setup. Ensure the door is setup to meet all applicable national & local standards.

20. Complete a Walk-Through-Test. Ensure compliance with ANSI/BHMA A156.10 & A156.19 all applicable national and local standards.

21. Replace header cover/dress plates.

Page 7: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

7 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Table: Wiring Inputs at Terminal Block

Terminal Function Description (All sensors inputs are dry contacts.)

10, 11 12 Vac Power Supply

Accessory Power: Output terminals for accessory power. Do not exceed 0.5 Amp.

12,14,16,18 Commons Commons: Commons for all the dry contact inputs.

13 End of Rail Beams

End-of-Rail-Beam: When photo beams are mounted to the end of a rail; the input is wired to this connector. This input is typically used with Header Mounted Sensors.

15 Safety Carpets

Safety Carpets: Safety carpets on the swing side of the door should be connected to this terminal.

17, M Activate

Activate: Standard activations are routed to this connection such as push plates, header mounted activate, activation carpets and door mounted activation sensors. Not used for secondary activate zone.

19, O Door

Mounted Safety

Door Mounted Safety: The control does not respond to this input at the near-full-open position. This prevents the wall and/or rail from being mistaken as an obstruction; and allows the full capabilities of the sensors to be used.

F,G 12 Vac Power Supply

Accessory Power: Output terminals for accessory power. Do not exceed 0.5 Amp.

H,L,N,U,W,Y Commons Commons: Commons for all the dry contact inputs.

I Header Mounted Safety

Header Mounted Safety: Swing side safety sensor, not active during door motion typically used with end of rail beams.

J Data - Output to Bodyguard

K Data + Output to Bodyguard

Q,R,S Electric Lock

Relay

Electric Lock Relay: Control for electric lock. Rated to accept 10A at 250Vac or 30 Vdc. Dip Switch “#3” must be “on”. Q - normally closed, R - common, S - normally open.

T Breakaway Breakaway: If this circuit is not closed, it will cause the control to shutdown. If a breakaway function is not being used, ensure a jumper is in place.

V Secondary Activate Zone

Secondary Activate Zone: This input is only active when the door is not fully closed. It is typically used for trailing traffic applications (knowing act).

X 2-3 Position

Switch

2-3 Position Switch: Jamb switches are typically routed to this input. The modes are: “On/Off” or “Off,” “Automatic” & “Hold Open.”

Z 2-3 Position

Switch

2-3 Position Switch: Jamb switches are typically routed to this input. The modes are: : “On/Off” or “Off,” “Automatic” & “Hold Open.”

Page 8: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

8 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section: Controller Settings & Adjustments

Program Selector Switch:

012 3 4

65

A987

FED CB

Table: Program Selector - Low Energy

Program Description

0 Two second hold open time when activated by Push & Go. Adjustable hold open time when activated by a dry-contact.

1 Adjustable hold open time when activated by Push & Go or a dry-contact.

2 Program “1” with Auto reverse in closing (the door will power open slowly if blocked or pushed open during closing).

3 Program “1” with Safety Stop

4 Reserved.

5 Alternate action – activate to open activate to close

! DANGER: This controller must be adjusted to ANSI standards by a

qualified person. Refer to the latest version of ANSI/BHMA A156.10 and A156.19 for proper door setup. Ensure the door is setup to meet all applicable national & local standards.

Enabling High Energy Programs – the next steps are NOT required if the unit was ordered as High Energy and a “HIGH ENERGY !” warning sticker is displayed next to the “Program Selector” on the control.

Page 9: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

9 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section: Controller Settings & Adjustments (continued) **Ensure power is disconnected from the control before proceeding** To enable the High Energy Programs, the control box must be opened and jumper J2 must be moved to the High Energy position. Safety sensors that are configured to meet the latest ANSI/BHMA A156.10 and A156.19 standards are required for High Energy operation.

High

Energy

Low

Energy

! DANGER: When using High Energy Programs appropriate safety

equipment must be in place See ANSI standards.

Page 10: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

10 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section: Controller Settings & Adjustments (continued) All inputs are dry-contacts.

! DANGER: When using High Energy Programs appropriate safety

equipment must be in place See ANSI standards.

Program Selector Switch:

012 3 4

65

A987

FED CB

Table: Program Selector - High Energy

Program Description

A High Energy applications with safety equipment that meets the latest ANSI/BHMA standards.

B Program “A” with Auto reverse in closing.

C Reserved

D Alternate action – activate to open activate to close

! DANGER: This controller must be adjusted to ANSI standards by a

qualified person. Refer to the latest version of ANSI/BHMA A156.10 and A156.19 for proper door setup. Ensure the door is setup to meet all applicable national & local standards.

Page 11: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

11 For technical assistance call 866-357-8832 MA50777-MNL_revP1

Section: Controller Settings & Adjustments (continued)

Table: DIP Switch Settings DIP# Option

“ON” Description

1

Power Boost

Continuous or 2 Sec.

While closed, the door remains powered toward the closed position until an activation signal is received. When the “Continuous” and “5 Sec.” switches are both “on” the result is “2 Sec.” Power Boost. Not available on “Low Force” operators.

2

Power Boost

5 Seconds or 2 Sec

While closed, the door remains powered toward the closed position for 5 seconds or until an activation signal is received. When the “Continuous” and “5 Sec.” switches are both “on” the result is “2 Sec.” Power Boost. . Not available on “Low Force” operators.

3 Electric

Lock Delay

Enables the 10A lock relay wired through “R”, “Q” and “S” terminals and sets a delay for door activation after lock is energized.

4 Low

Energy Push & Go

Door will power-open after it is manually pushed. Not available for program 5 (Alternate Action).

2 Sec.

SWITCHES

onoff

Electric Lock/Delay

Push & Go or Safety Stop

Power

Boost

Continuous

5 Seconds

1 2 3 4

4 High

Energy

Safety Stop

The door will stop while opening if a safety signal is detected through terminals 18 & 19 or “N” & “O”) (normally the doors will slow). Slow speed opening resumes after 2 seconds. Note: If the “Hold Open” voltage is set too high the door may not stop completely.

Table: Potentiometer Adjustments Function Description of Function

Opening Speed Sets the opening speed of the door.

Backcheck Speed Sets the speed of the door near the full open position.

Hold Voltage Sets the strength of the door in the open position such as to resist wind load etc. This setting also effects safety stop. If set too high the door will creep open when on safety stop setting.

Time Delay Sets how long the door stays open after activation (1-45 seconds).

Backcheck Position

Sets position that backcheck speed initiates.

Latch Position Sets position that latch speed initiates.

Master Closing Speed

Sets the closing speed of the Master door (M1).

Slave Closing Speed

Sets the closing speed of the Slave door (M2).

Page 12: MA50777 Swing Control - Motion Access · 2012. 12. 6. · CONDOR SWING MA50777 Swing Control For Motion Access Condor Swing Operators MotionAccess, LLC 775 Nicholas Blvd. Elk Grove

MOTIONACCESS, LLCautomatic entrance solutions

For technical assistance call 866-357-8832 MA50777-MNL_revN

Wiring Diagram: Condor Swing Control MA50777MotionAccess, LLC

750 Nicholas Blvd., Unit H

Elk Grove Village, IL 60007

toll free: 866-357-8832

847-357-8832, fax: 847-357-8834

www.MotionAccess.com

MA50777-WIRE_revA

12 Vac, .5APower Supply

10

11

12

13

14

15

16

17

18

19

Door

mounted

safety

Activate

(header mounted

sensor, door

mounted sensor,

pressplate etc.)

Safety

carpets

common

End of rail beam

common

Safety carpets

common

Activate

common

Door mounted safety

12

Vac

12 Vac

End of rail

beams

12 Vac 12 Vac

12 Vac, .5APower Supply

F

G

H

I

J

K

L

M

N

O

Door

mounted

safety

12

Vac

12 Vac

12 Vac

Data -

Header mounted safety

common

Data +

common

Activate

common

Door mounted safety

Power

Power

Common

(N. O.) Safety Signal

NOT USED

Data -

Data +

Bodyguard Reference

6

1

2

3

4

5

7

K

F

G

H

I

J

Header mounted safety

12

Vac

QNormally closed

Rcommon

SNormally openElectric

Lock

Relay

VSecondaryActivate Zone

Wcommon

2-3 PositionSwitch

TBreakaway

Ucommon

Breakaway

switch

Jumper if no

breakaway switch

Ycommon

Z

X

2-3 PositionSwitch Z

Electric

Lock

Depending on

Lock requirement

Motion Access

3 Position Switches

Rocker MA40011 or

Key Switch MA40111

Off / Auto / Hold Open

green

red

black

Secondary

Activation

Sensor

120 VACLINEinto header

Neutral

Earth Ground

Line (Hot)

Ground screw in headergreen

black

white

not used

WARNING! Black wire must be line

power (HOT) otherwise controler may

be damaged.

Reference Switch Logic

Mode

Auto

Hold open

OFF

X Y

open

open

closed

Z Y

open

open

closed

J8 J9 J7

J3

J6M1M2

Power connectoron control board

Single motoror

Master (pair)

Slave motor(pair only)

Controller MA50777

DANGER! 120 Vac Line power must be

deenergized before installing power

harness into connector J6.

Power harnessin header

Independentpowersupply

J7

J3

J6

M1

M2

J8

J9

This unit must be

adjusted to the

latest ANSI/BHMA

standardsby a

qualified person.!

Activate

(header mounted

sensor, door

mounted sensor,

pressplate etc.)

Bodyguard only

NOTE: SENSOR OUTPUT DRY CONTACT ONLY