Ma Griffith Tundish Access Panel Broch

2
MAG MAG-MIFAB Inwall Tundish Access Panels Use slip coupling Cover with viewing panel is the only part visible on wall. 5 Willsmore Street, (PO Box 718) Williamstown Victoria 3016 T: (61 3) 9399 8444 F: (61 3) 9399 8446 E: sales@magriffith.com.au W: www.magriffith.com.au 5 Willsmore Street, (PO Box 718) Williamstown Victoria 3016 T: (61 3) 9399 8444 F: (61 3) 9399 8446 E: sales@magriffith.com.au W: www.magriffith.com.au MAG Inwall Tundish The ideal air break. Made of 316 stainless steel to fit in fire rated walls. > Easy and economical to set up for air conditioning discharges > Easily removed face plate > Can be vandal proof fitted > Washing machine hose discharge box > Face plates are available in: Standard satin stainless steel with windows Non windowed, powdered coated or to your special requirements VARIOUS MODELS AVAILABLE Product Code Description No. 78000 MAG Windowed Inwall Tundish No. 78001 MAG Non Windowed Inwall Tundish No. 78006 MAG Washing Machine Hose Tundish No. 78006F MAG Washing Machine Hose Tundish with Hinge Cover No. 78010 MAG Inwall Tundish - Suit Clipsal Cover (supplied by others) 150mm 170mm 35mm 35mm Ears for fixing Nuts FRONT VIEW FRONT VIEW FRONT VIEW FRONT VIEW FRONT VIEW FRONT VIEW TOP VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW 130 mm 175 mm 70mm 65mm 95mm Face Flap 50mm 50mm 75mm 95mm 55mm 25mm Ø 95mm 55 x 20mm Slot 110 x 30mm Slot 50mm 60mm 15mm SS SLIP over outlet 40mm (use PVC slip coupling) COVER - 190 x 80 x 10mm SLOT - 110 x 30mm 78000 78006F 78006 78010 78001 140mm 135mm 40mm 60mm Ø Top 132mm The MIFAB ® MDW access door is designed for installation after the drywall has been applied and when a concealed outer flange is required, The outer frame has a galvanised drywall taping bead. Drywall cement can be applied over the beading at the same time as the wallboard joints and corners. Only the door is visible. It has a unique white finish. A-B Door Size C-D Overall Dimensions - Door Size - Plus 2 1/4” (57) E-F Wall Opening - Door Size - Plus 1/2” (12) A-B Door Size C-D Overall Dimensions - Door Size - Plus 2 1/8” (53) E-F Wall Opening - Door Size - Plus 3/8” (9) The MIFAB ® MI-VB valve box is designed for flush installation into walls to house valves and pipes. The MIFAB ® CAD-FL-PL recessed door is designed for flush installation in a drywall or plaster surface. The door panel is flush with frame. When installed flush with the wall or ceiling, only the door panel is exposed. A 3” wide metal lathe on all sides provides a rigid frame. A mounting bracket is recessed 5/8” from the door. It has a unique white finish. The MIFAB ® PA plastic access door is designed to provide easy access to plumbing and cables behind walls and ceilings. The door is removable from the frame and fits tightly with snap latches. The white finish can be painted or wallpapered or left as to match the surrounding environment. This door should not be installed near any existing or potential source of excessive heat or open flame. Door Size Wall Opening mm mm 305 x 305 317 x 317 356 x 356 368 x 368 406 x 406 419 x 419 457 x 457 470 x 470 610 x 610 622 x 622 A-B Door Size C-D Overall Dimensions - Door Size - Plus 5-1/2” (140) E-F Wall Opening - Door Size - Plus 1/2” (12) A-B Door Size C-D Overall Dimensions - Door Size - Plus 3” (75) E-F Wall Opening - Door Size - Minus 1/8” (3) Door Size Wall Opening mm mm 305 x 305 317 x 317 356 x 356 368 x 368 457 x 457 470 x 470 610 x 610 622 x 622 914 x 914 927 x 927 Door Size Wall Opening mm mm 203 x 203 200 x 200 356 x 356 352 x 352 Door Size mm 203 x 203 x 102 305 x 305 x 102 356 x 356 x 102 356 x 356 x 203 MA Griffith Tundish/Access Panel Broch.indd 1 1/10/08 1:20:46 PM

Transcript of Ma Griffith Tundish Access Panel Broch

Page 1: Ma Griffith Tundish Access Panel Broch

MAGMAG-MIFABInwall TundishAccess Panels

Use slip coupling

Cover with viewing panel is theonly part visible on wall.

5 Willsmore Street, (PO Box 718) Williamstown Victoria 3016

T: (61 3) 9399 8444 F: (61 3) 9399 8446

E: [email protected] W: www.magriffith.com.au

5 Willsmore Street, (PO Box 718) Williamstown Victoria 3016

T: (61 3) 9399 8444 F: (61 3) 9399 8446

E: [email protected] W: www.magriffith.com.au

MAG Inwall TundishThe ideal air break. Made of 316 stainless steel to fit in fire rated walls.

> Easy and economical to set up for air conditioning discharges > Easily removed face plate > Can be vandal proof fitted > Washing machine hose discharge box > Face plates are available in: • Standard satin stainless steel with windows • Non windowed, powdered coated or to your special requirements

VARIOUS MODELS AVAILABLE

Product Code Description No. 78000 MAG Windowed Inwall TundishNo. 78001 MAG Non Windowed Inwall TundishNo. 78006 MAG Washing Machine Hose TundishNo. 78006F MAG Washing Machine Hose Tundish with Hinge CoverNo. 78010 MAG Inwall Tundish - Suit Clipsal Cover (supplied by others)

150mm

170mm

35mm 35mm

Ears for fixing

Nuts

FRONT VIEW

FRONT VIEW

FRONT VIEW

FRONT VIEW

FRONT VIEW

FRONT VIEW

TOP VIEW

SIDE VIEW

SIDE VIEW

SIDE VIEW

SIDE VIEW

SIDE VIEW

130mm 175

mm

70mm

65mm

95mmFace Flap

50mm

50mm

75mm

95mm 55mm

25mm Ø95mm

55 x 20mm Slot110 x 30mm Slot

50mm

60mm

15mm

SS SLIP overoutlet 40mm(use PVC slip

coupling)

COVER - 190 x 80 x 10mmSLOT - 110 x 30mm

78000

78006F

78006

78010

78001

140mm135mm

40mm

60mm Ø Top

132mm

The MIFAB® MDW access door is designed for installation after the drywall has been applied and when a concealed outer flange is required, The outer frame has a galvanised drywall taping bead. Drywall cement can be applied over the beading at the same time as the wallboard joints and corners. Only the door is visible. It has a unique white finish.

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 2 1/4” (57)E-F Wall Opening - Door Size - Plus 1/2” (12)

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 2 1/8” (53)E-F Wall Opening - Door Size - Plus 3/8” (9)

The MIFAB® MI-VB valve box is designed for flush installation into walls to house valves and pipes.

The MIFAB® CAD-FL-PL recessed door is designed for flush installation

in a drywall or plaster surface. The door panel is flush with frame. When

installed flush with the wall or ceiling, only the door panel is exposed. A 3”

wide metal lathe on all sides provides a rigid frame. A mounting bracket is

recessed 5/8” from the door. It has a unique white finish.

The MIFAB® PA plastic access door is designed to provide easy access to

plumbing and cables behind walls and ceilings. The door is removable from the

frame and fits tightly with snap latches. The white finish can be painted or wallpapered

or left as to match the surrounding environment. This door should not be

installed near any existing or potential source of excessive heat or open flame.

Door Size Wall Openingmm mm

305 x 305 317 x 317356 x 356 368 x 368406 x 406 419 x 419457 x 457 470 x 470610 x 610 622 x 622

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 5-1/2” (140)E-F Wall Opening - Door Size - Plus 1/2” (12)

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 3” (75)E-F Wall Opening - Door Size - Minus 1/8” (3)

Door Size Wall Openingmm mm

305 x 305 317 x 317356 x 356 368 x 368457 x 457 470 x 470610 x 610 622 x 622914 x 914 927 x 927

Door Size Wall Openingmm mm

203 x 203 200 x 200356 x 356 352 x 352

Door Sizemm

203 x 203 x 102305 x 305 x 102356 x 356 x 102356 x 356 x 203

MA Griffith Tundish/Access Panel Broch.indd 1 1/10/08 1:20:46 PM

Page 2: Ma Griffith Tundish Access Panel Broch

MAG MAG-MIFABInwall Tundish Access Panels

MAG Inwall TundishSet up for current or future AC Wastes in shopping and office tenancies etc. Is also ideal for discharging to an above sink mounted IWT as the sink has live trap.

The MAG Inwall Tundish has been designed to fit into a 63mm stud wall.

The spigot or outlet fits into a slip coupling (Iplex D1244040) known as a 40mm copper to PVC adaptor which is complete with a Red Coloured Rubber to receive copper sized pipe with lubricant. This slips over the outlet.

If requiring a 25mm copper outlet (e.g. to kitchen sink trap), it is best to silver braze to copper or brass using high grade 45% silver content alloys. (Refer to brazing manufacturer for details).

Wall Opening for TundishThe cover is fitted with the opening to the bottom to allow overflow onto the adjacentsurfaces

Inlet ConnectionsThere a three inlet cut-outs in the top of the tundish, two are sealed with rubber grommets to allow for additional inlets.If not sealed with grommets, inlets should be sealed with epoxy similar to Ferropre or Silicon to prevent the entry of spiders, ants or other vermin.

The inlet pipe must be set to maintain the approved air gap. On completion of the project, test the maximum flow into the tundish to ensure that there is no splashing front he tundish.

It may be necessary to shield the inlet pipe similar to the splashing is contained within the tundish.

The MIFAB® UA is a multipurpose access door. It is designed for flush installation in drywall, block or tile, walls and ceilings. Frame features rounded safety corners, concealed hinge, flush with frame fit. It has a unique white finish. Door is formed for rigidity and safety. A-B Door Size

C-D Overall Dimensions - Door Size - Plus 2 1/8” (53)E-F Wall Opening - Door Size - Plus 3/8” (9)

A-B Recess - Door Size - Minus 3/16” (4)E-F Overall Dimensions - Door Size - Plus 3/8” (9)

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 2 1/4” (57)E-F Wall Opening - Door Size - Plus 1/2” (12)

A-B Door SizeC-D Overall Dimensions - Door Size - Plus 2 5/8” (66)E-F Wall Opening - Door Size - Plus 1/2” (13) (Allow an extra 1/4” (6) clearance for latch housing on “D” side).

The MIFAB® CAD recessed access door is designed for use in acoustical, drywall, or tiled surfaces. The door panel is recessed 5/8” to allow the insertion of various types of material. Only the thickness of the door and frame edges are exposed. It has a unique white finish.

The MIFAB® MPFR fire rated access door is fire rated by Underwriters Laboratories Inc., for 11/2 hours,

“B” label in walls and is rated by Warnock Hersey for 2 hours in

ceilings. The door meets ANSI-UL 10B standards. The same door can

be used in walls and ceilings.

The MIFAB® CAD-FL access door is designed for flush installation in a drywall or plastic surface. The door panel is flush with the frame. When

installed flush with the wall or ceiling only the door panel is exposed. A

mounting bracket is recessed 5/8” from the door. It has a unique white finish.

Pipe SleeveAllow to cut a socket of thepipe size to the fit over thepipe and rotate to the bestangle within the opening,check for splashing.

APPLICATIONS

A

A Connected to wet area floor waste gully.

B Built into toe space. Overflow to floor.

C Built into wall. Overflow to sink top.

D Built into duct or wall. Overflow to sink top.

E Built into wall. Overflow to floor.

Diagramatic only: Some connections maybe subject to State or Local approval

32mm pipe built in wall cappedin ceiling for future connection.

Inwall Tundish with waste connected above wasteseal of FWG

Opening

Opening

Bath/Wet Area

Condensor

IWT

B

CD

E

Ferropre orSilicon Seal

Rotate Socketto suit

> Undercoat finish > Powder coating available

> Rigid engineered construction > Stainless steel available

> Rounded safety corners > Speciality locks availableFEATURES & BENEFITS

Door Size Wall Openingmm mm

305 x 305 314 x 314356 x 356 365 x 365457 x 457 466 x 466610 x 610 619 x 619914 x 914 924 x 924

Door Size Wall Openingmm mm

305 x 305 317 x 317356 x 356 368 x 368457 x 457 470 x 470610 x 610 622 x 622914 x 914 927 x 927

Door Size Wall Openingmm mm

305 x 305 318 x 318356 x 356 368 x 368457 x 457 470 x 470610 x 610 622 x 622914 x 914 927 x 927

Door Size Wall Openingmm mm

305 x 305 314 x 314406 x 406 416 x 416457 x 457 467 x 467610 x 610 619 x 619

MA Griffith Tundish/Access Panel Broch.indd 2 1/10/08 1:20:47 PM