M E Progress Report ( 11 Feb 2013 )
-
Upload
moe-htun-libra -
Category
Documents
-
view
17 -
download
0
Transcript of M E Progress Report ( 11 Feb 2013 )
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
PROGRESS MONITORING CHART --- M&E -- Tower 1PLUMBING SANITARY ACMV
1 2 3 4 5 6 7 8 9 10 11 12
WALL, FLOOR & CEILING PIPING PRESSURE TEST WALL & FLOOR COCEAL PIPE LEAK & FLOW TEST HEATER INSTALLATION SANITARY FIXTURE LEAK & FLOW TEST REFRIGERANT PIPE INSTALLATION NITROGEN TEST FCU & CU INSTALLATION TESTING & COMMISSIONING
UNITS 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06
TYPE B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L
#21 60% 60% 60% 60% 60% 60% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#20 60% 60% 60% 60% 60% 60% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#19 60% 60% 60% 80% 80% 80% 80% 80% 80% 80% 100% 100% 100% 100% 100% 100%
#18 80% 80% 60% 60% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#17 80% 80% 60% 60% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#16 80% 80% 85% 60% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#15 80% 35% 85% 70% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#14 80% 30% 85% 70% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#13 80% 30% 85% 70% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#12 70% 80% 85% 80% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 30% 30% 30% 30% 30% 30%
#11 60% 80% 80% 80% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#10 60% 80% 80% 80% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#9 85% 80% 80% 80% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#8 85% 80% 80% 100% 100% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 90% 90% 90% 90% 90% 90%
#7 100% 100% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#6 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#5 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#4 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#3 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#2 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
79% PRESSURE TEST 27% 99% LEAK & FLOW TEST 3% 100% SANITARY FIXTURE 0% 70% LEAK & FLOW TEST 25% 39% NITROGEN TEST 23% 0% 0%
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon
PROGRESS MONITORING CHART --- M&E -- Tower 2PLUMBING SANITARY ACMV
1 2 3 4 5 6 7 8 9 10 11 12
WALL, FLOOR & CEILING PIPING PRESSURE TEST WALL & FLOOR COCEAL PIPE LEAK & FLOW TEST HEATER INSTALLATION SANITARY FIXTURE LEAK & FLOW TEST REFRIGERANT PIPE INSTALLATION NITROGEN TEST FCU & CU INSTALLATION TESTING & COMMISSIONING
UNITS 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06
TYPE B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L
#21 35% 50% 35% 35% 85% 90% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#20 35% 80% 80% 80% 85% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#19 35% 80% 80% 80% 85% 80% 100% 100% 100% 100% 80% 80% 100% 100% 100% 100% 100% 100%
#18 80% 80% 80% 80% 85% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#17 80% 80% 80% 80% 85% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#16 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#15 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#14 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#13 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#12 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 30% 30% 30% 30% 30% 30%
#11 90% 90% 90% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 50% 50% 50% 50% 50% 50%
#10 90% 90% 85% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#9 90% 90% 85% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#8 90% 90% 85% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#7 90% 90% 85% 90% 90% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 80% 100% 100% 100% 100%
#6 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#5 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#4 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#3 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 30% 80% 30% 30% 30% 100%
#2 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
WALL & FLOOR CONDENSATION DRAIN PIPE
WALL, FLOOR & CEILING PIPING
WALL & FLOOR COCEAL PIPE
HEATER INSTALLATION
WALL & FLOOR CONDENSATION DRAIN PIPE
REFRIGERANT PIPE INSTALLATION
FCU & CU INSTALLATION
TESTING & COMMISSIONING
WALL & FLOOR CONDENSATION DRAIN PIPE
TRADES
TRADES
WALL, FLOOR & CEILING PIPING 87% PRESSURE TEST 19% WALL & FLOOR COCEAL PIPE 99% LEAK & FLOW TEST 15% HEATER INSTALLATION 79% SANITARY FIXTURE 5% 69% LEAK & FLOW TEST 24% 33% NITROGEN TEST 29% FCU & CU INSTALLATION 3% TESTING & COMMISSIONING 0%
RESOURCES GROUPPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
PROGRESS MONITORING CHART --- M&E -- Tower 1
ELECTRICAL ELV SYSTEMS
1 2 3 4 5 6 7 8 9
NEW CABLE MEGA TEST FIXTURES CONDUITE PIPING CABLING CONTINUTY TEST FIXTURES
UNITS 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06
TYPE B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L
#21 100% 100% 95% 100% 95% 95% 100% 100% 98% 100% 95% 95% 70% 40% 70% 70% 30% 70% 70% 90% 90% 100% 100% 100% 50% 70% 90% 100% 100% 100%
#20 100% 100% 100% 90% 100% 100% 100% 95% 100% 90% 100% 100% 15% 100% 100% 100% 80% 80% 100% 100% 60% 5% 80% 80% 90% 100% 10%
#19 50% 25% 70% 80% 25% 30% 50% 30% 70% 80% 20% 50%
#18 20% 30% 70% 30% 30% 90% 20% 20% 70% 20% 20% 90%
#17 25% 80% 95% 70% 65% 95% 20% 70% 95% 70% 65% 95% 90% 95%
#16 60% 75% 95% 30% 70% 95% 50% 60% 95% 20% 70% 95% 60% 95%
#15 95% 65% 95% 60% 95% 80% 90% 60% 95% 60% 95% 80% 20% 95% 95%
#14 80% 75% 90% 95% 90% 95% 80% 70% 90% 90% 90% 95% 40% 80% 80% 75% 80% 40% 80% 80% 80% 80%
#13 95% 95% 95% 95% 95% 60% 95% 95% 95% 95% 95% 50% 95% 95% 95% 95% 95% 60% 40% 70% 50% 40% 60% 60% 50%
#12 75% 95% 95% 95% 95% 90% 60% 95% 95% 90% 95% 90% 90% 95% 95% 95% 60% 50% 70% 50% 30% 30% 60% 20% 60% 40%
#11 95% 95% 55% 95% 100% 75% 90% 95% 65% 90% 75% 75% 80% 95% 95% 70% 80% 70% 70% 70% 30% 70% 80%
#10 95% 90% 60% 100% 100% 90% 90% 90% 50% 100% 100% 90% 40% 90% 100% 100% 70% 70% 70% 70% 70% 30% 60% 70%
#9 90% 90% 85% 100% 100% 85% 90% 95% 75% 100% 100% 70% 90% 90% 100% 95% 80% 75% 70% 70% 70% 20% 80% 75%
#8 90% 95% 75% 100% 95% 90% 85% 95% 75% 100% 95% 80% 95% 100% 95% 75% 95% 75% 70% 70% 70% 70% 80% 75% 40% 70%
#7 95% 100% 95% 100% 100% 100% 90% 100% 95% 100% 100% 100% 95% 100% 100% 100% 100% 80% 100% 100% 100% 100% 70% 80% 100% 80% 100% 100% 85%
#6 100% 100% 90% 100% 95% 100% 100% 100% 95% 100% 95% 100% 100% 100% 85% 100% 20% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#5 100% 100% 90% 100% 90% 90% 100% 100% 90% 100% 90% 90% 100% 100% 20% 100% 30% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#4 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 80% 100% 100% 50% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#3 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 60% 100% 100% 50% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#2 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 95% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
86% 85% NEW CABLE 56% MEGA TEST 0% FIXTURES 0% CONDUITE PIPING 57% CABLING 47% CONTINUTY TEST 0% FIXTURES 0%
RESOURCES GROUPPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
PROGRESS MONITORING CHART --- M&E -- Tower 2ELECTRICAL ELV SYSTEMS
1 2 3 4 5 6 7 8 9NEW CABLE MEGA TEST FIXTURES CONDUITE PIPING CABLING CONTINUTY TEST FIXTURES
UNITS 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06 01 02 03 04 05 06
TYPE B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L B1 A1 B2R B3 C1 B2L
#21 90% 80% 75% 70% 70% 60% 80% 80% 80% 70% 70% 80% 55% 70% 75% 90% 90% 90% 95% 90% 90% 90% 80% 95% 90% 95%
#20 80% 90% 45% 90% 85% 15% 80% 85% 30% 90% 85% 10% 85% 90% 100% 100% 95% 100% 75% 100% 95% 100% 95% 20% 60%
#19 100% 90% 50% 40% 60% 50% 70% 80% 50% 40% 80% 80% 60% 80% 95% 85% 30% 95% 95% 85%
#18 90% 90% 50% 50% 70% 40% 90% 90% 50% 50% 90% 70%
#17 100% 70% 60% 90% 95% 50% 70% 70% 50% 85% 90% 85% 80% 90%
#16 85% 70% 95% 20% 25% 90% 70% 70% 95% 10% 10% 85% 50%
#15 100% 100% 50% 15% 40% 85% 50% 100% 40% 15% 10% 85% 75% 5%
#14 40% 100% 100% 20% 90% 80% 30% 100% 80% 10% 90% 80% 90%
#13 100% 100% 100% 30% 55% 100% 100% 100% 100% 10% 65% 80% 100% 100% 90% 40% 30% 75%
#12 100% 100% 100% 70% 80% 100% 100% 100% 100% 60% 70% 80% 100% 70% 90% 10% 80% 50%
#11 100% 100% 100% 20% 100% 35% 100% 100% 100% 10% 100% 10% 80% 100% 20% 80% 50%
#10 100% 100% 100% 30% 95% 15% 100% 100% 100% 25% 90% 10% 20% 60% 75% 40% 100% 100% 50% 20% 100% 100%
#9 60% 95% 100% 90% 100% 30% 40% 90% 100% 90% 100% 20% 10% 90% 100% 100% 100% 75% 75% 100% 100% 100% 100% 40% 60% 100% 100% 100%
#8 90% 100% 100% 90% 100% 100% 100% 100% 100% 100% 100% 100% 20% 100% 100% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#7 100% 100% 100% 100% 95% 100% 100% 100% 100% 100% 95% 100% 90% 100% 100% 90% 80% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#6 100% 100% 90% 90% 95% 100% 100% 100% 90% 90% 80% 100% 90% 90% 70% 80% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#5 100% 100% 90% 100% 90% 100% 100% 100% 90% 100% 90% 100% 90% 100% 100% 90% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#4 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
WALL & FLOOR CONDENSATION DRAIN PIPE
REFRIGERANT PIPE INSTALLATION
WALL & FLOOR PIPE INSTALLATION ABOVE CEILING -- TRUNKING & CONDUITE
WALL & FLOOR PIPE INSTALLATION
ABOVE CEILING -- TRUNKING & CONDUITE
WALL & FLOOR PIPE INSTALLATION ABOVE CEILING -- TRUNKING & CONDUITE
TRADES
TRADES
#3 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
#2 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
81% 79% NEW CABLE 46% MEGA TEST 5% FIXTURES 1% CONDUITE PIPING 56% CABLING 50% CONTINUTY TEST 1% FIXTURES 1%
TOWER 1 & 2 --- OVERALL SUMMARY
TASK DESCRIPTIONS TOWER 1 TOWER 2
PLUMBING
1 WALL, FLOOR & CEILING PIPING 78.58% 87.17% 82.88%
2 PRESSURE TEST 26.67% 19.17% 22.92%
SANITARY
3 WALL & FLOOR COCEAL PIPE 99.00% 98.83% 98.92%
4 LEAK & FLOW TEST 2.50% 15.00% 8.75%
5 HEATER INSTALLATION 100.00% 79.17% 89.58%
6 SANITARY FIXTURE 0.00% 5.00% 2.50%
ACMV
7 WALL & FLOOR CONDENSATION DRAIN PIPE 70.00% 69.17% 69.58%
8 LEAK & FLOW TEST 25.00% 24.17% 24.58%
9 REFRIGERANT PIPE INSTALLATION 38.50% 33.17% 35.83%
10 NITROGEN TEST 23.33% 29.00% 26.17%
11 FCU & CU INSTALLATION 0.00% 2.50% 1.25%
12 TESTING & COMMISSIONING 0.00% 0.00% 0.00%
ELECTRICAL
1 WALL & FLOOR PIPE INSTALLATION 86.38% 81.12% 83.75%
2 ABOVE CEILING -- TRUNKING & CONDUITE 84.82% 78.71% 81.76%
3 NEW CABLE 56.21% 45.50% 50.85%
4 MEGA TEST 0.00% 5.00% 2.50%
5 FIXTURES 0.00% 0.83% 0.42%
ELV SYSTEMS
6 CONDUITE PIPING 57.33% 56.50% 56.92%
7 CABLING 46.88% 50.13% 48.50%
8 CONTINUTY TEST 0.00% 0.83% 0.42%
9 FIXTURES 0.00% 0.83% 0.42%
WALL & FLOOR PIPE INSTALLATION
ABOVE CEILING -- TRUNKING & CONDUITE
CURRENT STATUS
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
PROGRESS MONITORING CHART --- M&E -- Tower 1 ( Lift Lobby )
S/N TASK STOREY1 PLUMBING STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Ceiling piping 0%
b Pressure test 0%
c Riser piping 0%
d Water meter 0%
2 ELECTRICAL WORK STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90% 90%
b New cable 0%
c Megga test 0%
d Fixtures 0%
e Riser tray 0%
f Riser cabling 0%
g Metering panel & tap off 0%
3 FIRE ALARM WORKS STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
b New Cable 70% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
c Megger Test 0%
d Fixtures 0%
3 CCTV/PA WORK STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 51% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 25%
b New Cable 5% 100%
c Continuty Test 0%
d Fixtures 0%
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
PROGRESS MONITORING CHART --- M&E -- Tower 2 ( Lift Lobby )
S/N TASK STOREY1 PLUMBING STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Ceiling piping 75% 80% 100% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 60% 60% 60% 60% 60% 60%
b Pressure test 0%
c Riser piping 3% 50%
d Water meter 5% 100%
2 ELECTRICAL WORK STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 20% 100% 100% 100% 100%
b New cable 5% 100%
c Megga test 0%
d Fixtures 0%
e Riser tray 0%
f Riser cabling 0%
g Metering panel & tap off 0%
3 FIRE ALARM WORKS STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 85% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
b New Cable 5% 100%
c Megger Test 0%
d Fixtures 0%
3 CCTV/PA WORK STATUS #02 #03 #04 #05 #06 #07 #08 #09 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21
a Trunking conduit piping 25% 100% 100% 100% 100% 100%
b New Cable 0%
c Contituty Test 0%
d Fixtures 0%
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
S/N TASK DESCRIPTIONS & STATUS
1 PLUMBING CURRENT STATUS REMARKS
a YCDC main pipe
b Valve pit & Water meter
c Underground piping
e Garden tap
f New Tube well ( drilling & casing )
g Pump c/w panel
h Piping to raw water tank
2 SANITARY WORKS CURRENT STATUS REMARKES
a Underground piping 30%
b Inspection chamber 20%
c Flow test
3 FIRE PROTECTION CURRENT STATUS REMARKS
a Piping
b Pressure test
c Equipments
4 SWIMMING POOL CURRENT STATUS REMARKS
a Piping 20%
b Pump & Equipments
c Testing
d Fixtures
5 SEWAGE TREATMENT CURRENT STATUS REMARKS
a Piping
PROGRESS MONITORING CHART --- EXTERNAL M&E ITEMS - Mechanical
b Pump & Equipment
c Testing
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
S/N TASK DESCRIPTIONS & STATUS
1 HT CURRENT STATUS REMARKS
a Cabling works 48%
d Cable joint test
2 LT (400V) CURRENT STATUS REMARKES
a Lead-in pipe 100%
b Draw pit & M/H 100%
c Cabling works 3%
d Mega test
3 LIGHTING & POWER (230V) CURRENT STATUS REMARKS
a Cabling Work
b Megga test
c Fixture
d Testing & Commissioning
4 ELV CURRENT STATUS REMARKS
a Lead-in pipe
b Draw pit & M/H
c Cabling works
d Continuity test
PROGRESS MONITORING CHART --- EXTERNAL M&E ITEMS - Electrical
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
TOWER 1 --- M&E PROGRESS @ 1ST FLOOR
S/N TASK DESCRIPTIONS & STATUS
1 PLUMBING WORKS CURRENT STATUS REMARKS
a Piping
b Pump & Equipment
c Testing
2 SANITARY WORKS CURRENT STATUS REMARKES
a Piping
b Testing
c Fixtures
3 FIRE PROTECTION CURRENT STATUS REMARKS
a Piping
b Pressure test
c pump & Equipments
4 ACMV CURRENT STATUS REMARKS
a Condensate pipe
b Leak & flow test
c Refrigerant piping
d N2 Test
e Ducting
f FCU / CU
g Ventilation Fan
h Grille & Diffuser
i Testing & Commissioning
5 SUB-STATION CURRENT STATUS REMARKS
a HT / LT / TRANSFORMER
b HT Switch gear
c 33 / 11Kv, 11/0.4 Transformer
d LT Switch board
e Testing
6 GEN SET CURRENT STATUS REMARKS
a Gen set
b Pump, Tank & Piping
c Testing & commissioning
7 COMMON AREAS CURRENT STATUS REMARKS
a Tray, trunking & conduit
b Sub-main cable
c Final circuit cabling
d Megga test
e Fixtures
8 ELV CURRENT STATUS REMARKS
a Tray, trunking & conduit
b Cabling
c Continuty test
d Fixtures
e Equipment
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon UPDATED ON: 8-Apr-23
TOWER 2 --- M&E PROGRESS @ 1ST FLOOR
S/N TASK DESCRIPTIONS & STATUS
1 PLUMBING CURRENT STATUS REMARKS
a Piping
b Pump & Equipment
c Testing
2 SANITARY WORKS CURRENT STATUS REMARKES
a Piping
b Testing
c Fixtures
3 FIRE PROTECTION CURRENT STATUS REMARKS
a Piping
b Pressure test
c pump & Equipments
4 ACMV CURRENT STATUS REMARKS
a Condensate pipe
b Leak & flow test
c Refrigerant piping
d N2 Test
e Ducting
f FCU / CU
g V Fan
h Grille & Diffuser
i Testing & Commissioning
5 SUB-STATION CURRENT STATUS REMARKS
a HT / LT / TRANSFORMER
b HT Switch gear
c 33 / 11Kv, 11/0.4 Transformer
d LT Switch board
e Testing
6 GEN SET CURRENT STATUS REMARKS
a Gen set
b Pump, Tank & Piping
c Testing & commissioning
7 COMMON AREAS CURRENT STATUS REMARKS
a Tray, trunking & conduit
b Sub-main cable
c Final circuit cabling
d Megga test
e Fixtures
8 ELV CURRENT STATUS REMARKS
a Tray, trunking & conduit
b Cabling
c Continuty test
d Fixtures
e Equipment
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon
TOWER 1 --- M&E PROGRESS @ ROOF
S/N TASK DESCRIPTIONS & STATUS
1 PLUMBING WORKSa Piping w/water tap
b Raw Water Transfer Pump w/piping
c Raw Water Storage tank w/piping
( 5m x 3m x 2m )
d Water Treatment equipment & piping
e Domestic Storage Water Tank w/piping
( 3m x 2m x 2m )
f Booster pump w/ piping
g Testing & Commissioning
2 SANITARY WORKSa Vent pipe w/vent cowl
b Waste pipe w/drain cover
3 FIRE PROTECTION a Wet Riser Tank w/piping
( 6m x 4m x 3m )
b Wet Riser Pump w/piping
c Hose Reel w/piping
d Testing & Commissioning
e Conduite / trunking piping
f Cabling work
g Heat/smoke detector,alarm bell etc
4 ACMVa Ducting
b Ventilation Fan
c Allow to Electrical Work cw/ Control Panel
d Testing & commissioning
5 ELECTRICAL WORKa Conduit, trunking work
b Cabling work
c Megga Test
d Fixture
6 ELVa Conduit & trunking
b Cabling
c Continuity Test
d MATV Rack
e Sattelite Disc
f CCTV Camera
ELTG PTE LTDPROJECT : Shangri-La Residence @Yangon
TOWER 2 --- M&E PROGRESS @ ROOF
S/N TASK DESCRIPTIONS & STATUS
1 PLUMBING WORKSa Piping w/water tap
b Raw Water Transfer Pump w/piping
c Raw Water Storage tank w/piping
d Water Treatment equipment & piping
e Domestic Storage Water Tank w/piping
( 3m x 2m x 2m )
f Booster pump w/ piping
g Testing & Commissioning
2 SANITARY WORKSa Vent pipe w/vent cowl
b Waste pipe w/drain cover
3 FIRE PROTECTION a Wet Riser Tank w/piping
( 6m x 4m x 3m )
b Wet Riser Pump w/piping
c Hose Reel w/piping
d Testing & Commissioning
e Conduite / trunking piping
f Cabling work
g Heat/smoke detector,alarm bell etc
4 ACMVa Ducting
b Ventilation Fan
c Allow to Electrical Work cw/ Control Panel
d Testing & commissioning
5 ELECTRICAL WORKa Conduit, trunking work
b Cabling work
c Megga Test
d Fixture
6 ELVa Conduit & trunking
b Cabling
c Continuity Test
d MATV Rack
e Sattelite Disc
f CCTV Camera
ELTG PTE LTDUPDATED ON: 8-Apr-23
TOWER 1 --- M&E PROGRESS @ ROOF
TASK DESCRIPTIONS & STATUS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKES
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS
ELTG PTE LTDUPDATED ON: 8-Apr-23
TOWER 2 --- M&E PROGRESS @ ROOF
TASK DESCRIPTIONS & STATUS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKES
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS
CURRENT STATUS REMARKS