LWL-Inspektion & Reinigung 2018 - opternus.de · Beispiele für Einzelfaser Stecker (und viele...

1
Beispiele für Einzelfaser Stecker (und viele weitere...) FIP-400 Adapter Spitzen APC FIP-400 Adapter Spitzen UPC Male Female Male Female FIPT-400-U25MA FIPT-400-SC-APC SC Simplex (singlemode/ multimode) FIPT-400-U25M FIPT-400-FC-SC SC Duplex (singlemode/ multimode) FIPT-400-FC-APC FC Simplex (singlemode/ multimode) N/A ST Simplex (singlemode/ multimode) FIPT-400-ST FIPT-400-E2000- APC E2000 Simplex (singlemode/ multimode) FIPT-400-E2000 E2000 Duplex (singlemode/ multimode) FIPT-400-U12MA FIPT-400-LX5-APC LX-5 Simplex (singlemode/ multimode) FIPT-400-U12M FIPT-400-LX.5 LX-5 Duplex (singlemode/ multimode) FIPT-400-LC-APC LC Simplex (singlemode/ multimode) FIPT-400-LC LC Duplex (singlemode/ multimode) N/A MU Simplex (singlemode/ multimode) FIPT-400-MU MU Duplex (singlemode/ multimode) Mehrfaser Stecker FIP-400 Adapter Spitzen APC FIP-400 Adapter Spitzen UPC Male Female Male Female N/A MT-RJ (2 fibers) (singlemode/ multimode) FIPT-400-MTRJ and a coupler FIPT-400-MTRJ FIPT-400-MTPA2 and a coupler FIPT-400-MTPA2 MTP/MTPA/MPO (4, 8, 12 fibers) (singlemode/ multimode) FIPT-400-MTP2 and a coupler FIPT-400-MTP2 FTTA Stecker FIP-400 Adapter Spitzen UPC Male Female Outdoor connector (ODC) 2 fibers (singlemode/multimode) FIPT-400-ODC-S FIPT-400-ODC- 2PIN-P-K Outdoor connector (ODC) 4 fibers (singlemode/multimode) FIPT-400-ODC- 4PIN-P-K FTTH Stecker FIP-400 Adapter Spitzen UPC Male Female OptiTap ® (drop terminal with single fiber ports) 1 fiber (singlemode/multimode) FIPT-400-U25MA FIPT-400-OTAP- APC OptiSheat ® (drop terminal with multifiber expansion port) Up to 12 fibers (singlemode) FIPT-400-U25MA and FIPT-400- OTAP-MTP-APC FIPT-400-OTAP- APC and FIPT-400- OTAP-MTP-APC OptiTip ® Up to 12 fibers (singlemode/multimode) FIPT-400-OTAP-MTP-APC Mehrfaser Stecker Inspektion: Mit 3 Klicks alles erledigt! Stecker Stecker-Problematik Kriterien der LWL Steckerinspektion Steckerreinigung Lösungen Dank EXFOs leistungsfähiger Messgeräte-Plattformen, auf denen auch die Auswertesoftware ConnectorMax läuft, stehen integrierte Lösungen für Messtechnik, Inspektion, Auswertung nach IEC / IPC und Protokoll zur Verfügung. Empfohlene Inspektions- und Reinigungsprozedur “Wenn die Steckerinspektion aufgrund von Defekten ein negatives Ergebnis bringt, muss der Stecker gereinigt werden und die Inspektion muss wiederholt werden” Den Stecker immer 2x reinigen bevor man ihn tauscht. Trockenreinigung Eine mechanische Trockenreinigung ist immer der erste Schritt. Wenn nach 2 Reinigungs- versuchen die Verschmutzung immer noch vorhanden ist, probieren Sie eine hybride Reinigung. Hybride Reinigung „Nassreinigung“ Die „hybride Reinigung“ ist eine Kombination aus Nass- und Trockenreinigung. Im ersten Schritt wird der Stecker mit einer Reinigungsflüssigkeit gereinigt und im zweiten Schritt werden Rück- stände mit einem fusselfreien Tuch oder Tupfer entfernt. Wenn der Stecker nach dieser Prozedur die Kriterien immer noch nicht erfüllt, sollten Sie er- wägen, ihn auszutauschen. Wie funktioniert die Trockenreinigung Einfacher als mit dem OCC geht es nicht: Nur den Stecker aufstecken und mit dem Reinigungs- tool einen leichten Druck ausüben, bis ein Klicken zu hören ist - fertig. Das funktioniert auch im Patch- Feld durch die Kupplung hindurch. Für Mehrfaser-Stecker gibt es spezielle Reiniger. Standardisierte Kriterien IEC 61300-3-35 Fiber-optic interconnecting devices and passive components—basic test and measurement procedures http://webstore.iec.ch/ ANALYSIS SOFTWARE „Was du in Vorsorge investierst, zahlt sich 10-fach aus!“ Die meisten Probleme in Glasfasernetzen werden durch verschmutzte Stecker verursacht! • Mehrfaser Stecker werden in verschiedenen Anwendungen eingesetzt, zum Beispiel FTTH, Datacenter, ROADM etc. Gängige Typen sind PTM ,OPM ® * und OptiTip ® * * MTP is a registered trademark of US Conec and OptiTip is a registered trademark of Corning Cable Systems Erfüllt die zulässigen Kriterien? Nein Nein Nein Ja Ja Ja Fehler wegen Kratzern? Fehler verringert ? Anzahl Kratzer und Fehler Fehler wg. Schmutz Prüfling besteht nicht Prüfling besteht Ende Stecker reinigen Start Anzahl Kratzer und Fehler 3 1 2 Führungsstifte/-löcher Optische Faser Ferrule Optische Mikroskope Nur für „männliche“ Stek- ker geeignet (keine Buchsen) Nicht 100%ig sicher bei in Betrieb befindlichen Netzen. Risiko der Augenverletzung durch Laserlicht. Wo prüfen/reinigen Folgende Dinge sollten immer auf Ihrer Inspektions- und Reinigungsliste stehen: h-Feld ( z.B. Splitter, Schaltschrank) c t a P r e p m u J t s e T Wann reinigen Der allererste Schritt ist die Stecker-Inspektion. Das gilt für alle Testphasen – Konstruktion, Inbetriebnahme und Wartung. Stecker sollten nur gereinigt werden, wenn sich bei der Inspektion herausstellt, dass Sie schmutzig sind. Wie prüfen 1. Verbinden Sie das Mikroskop mit dem Stecker und wählen Sie den entsprechenden IEC Standard. 2. Stellen Sie die maximale Vergrößerung ein 3. Starten Sie die Analyse mit dem Capture Knopf. 4. PrüfenSie die Pass-Fail-Anzeige an der FIP od. am Monitor . Reinigen oder ersetzen Sie den Stecker abhängig vom Resultat. 5 6. Speichern Sie den Report. Faser-Inspektions-Probe mit FTB Plattform • Arbeitet mit dem Display der Plattform • Speichert Bilder zu Referenz- Zwecken Leistet eine automatische Bildauswertung Patch Panel-Prüfung (durch die Buchse) 2 4 3 FIP-Lösungen -- Test Möglichkeiten tabellarisch Komfortable Faser Inspektions Test Kits Staub- und Schmutz-Rückstände Wenn nicht sorgfältig gereinigt wird, können Rückstände übertragen werden und beim Stecken sogar dauerhafte Schäden verursachen. Feuchte Rückstände • Meistens durch eine ungeeignete Reinigungs- methode verursacht — die Stecker müssen nach einer Nassreinigung sorgfältig getrocknet werden. Ölige Rückstände Kreisrunde Rückstände • Meistens durch eine ungeeignete Reinigungs- methode verursacht. • Entsteht, wenn noch nass gesteckt wird. • Tritt typischerweise im Kontaktbereich auf. • Die Verunreinigungen werden von dem einen auf den anderen Stecker übertragen. Defekte in der Kleberegion • Kann schon im Herstellungsprozess entstehen oder durch falsche Handhabung. • Epoxy-Rückstände oder Chips können in dieser Region aftreten. Akzeptabel innerhalb der Standards. Schmutziger/beschädigter Stecker • Entsteht meist durch falsche Handhabung oder Fehler beim Reinigen. • Auch wenn die Fehler klein erscheinen mögen, können Sie trotzdem unzulässig sein. Kratzer • Können als helle oder dunkle Fehler erscheinen. • Sind mit bloßem Auge möglicherweise nicht zu erkennen. • Kritisch, wenn im Kernbereich. Vor der Reinigung Nach der Reinigung Patch Panel Patch Panel N. d. Trocknen Eine Steckerendfläche hat verschiedene Zonen e Stecker haben unterschiedlich große Bereiche. d o m e l g n i S d n u e d o m i t l u •M • Größen sind abhängig von Stecker- und Fasertyp Core (0-65 μm) Core (0-25 μm) Cladding (65-120 μm) Cladding (25-120 μm) Adhesive (120-130 μm) Adhesive (120-130 μm) Contact (130-250 μm) Contact (130-250 μm) Beispiel für ein Reinigungskit (optional) FTB-1 Überzug (offen) FTB-1 Überzug (geschlossen) Beispiel für ein Reinigungskit (optional) OCC - mechanische Reinigung von Einzelfaser-Steckern (male/female) Mechanischer Reiniger für Mehrfaser-Stecker (MTP/MPO) (male/female) Cletop - mechanische Reinigung von Patch-Kabeln LWL-Reinigungsmaterial auf der Opternus-Homepage Quick Link (http:www...) TK-1 / TK-2-FIP-400B Auf Basis der leistungsfähigen Plattformen FTB-1, FTB-2 und sogar des MaxTesters, kombiniert dieses Test Set eine Fiber Inspection Probe mit einem großen 7-Zoll Display, integriertem opti- schen Leistungsmessgerät und Visual Fault Locator (VFL). Damit kombinierbar ist die ConnectorMax 2 Software zur automatisierten Pass-/Fail-Bewertung der Steckerendflächen sowie eine komplette IP-Service Test Suite. IEC Zonengrößen von PC Steckern mit Multimode Fasern IEC Zonengrößen von PC Steckern, Singlemode non-dispersion shifted Faser, RL ≥45 dB • LWL-Stecker • Häufig durch Anfassen verursacht. • Ein öliger Rückstand kann wie ein Matching Gel wirken. • Beeinflusst möglicherweise IL/RL nicht kurzfristig. ABER kann Staub anziehen und IL/RL negativ beeinflussen. ConnectorMax 2 Analyse Software • Unter Anwendern innerhalb einer Firma • Zwischen Ausrüster und Kunden • Zwischen Dienstleister und Netzbetreiber • Garantiert einheitliche Bewertungskriterien • Einfache Entscheidungsfindung ohne subjektive Einflüsse Mühelose Steckerinspektion Um Mehrfaser Stecker zu untersuchen, wird ein besonderes Inspektions-Tool benötigt. Der neue Mehrfasersteckeradapter von EXFO hat einen Revolverabzug um durch die einzelnen Fasern zu springen - auf diese Weise kann keine Faser übersehen werden! Für die verschiedenen Typen von Mehrfasersteckern werden entsprechende Adapteraufsätze angeboten, jeweils für Grad- und Schrägschliff. Die schlanke Bauform ermöglicht es auch in engen Umgebungen, wie im Rechenzentrum, an die Stecker bzw. Buchsen heranzukommen, was mit Lösungen anderer Hersteller oft nicht gelingt. Pass/Fail wird direkt an der Probe angezeigt und die Steckerbilder werden an das Smartphone oder einen Computer übertragen. 6 1 Standard Inspection Test Sequence FIP-430B Inspection Test Sequence MANUAL STEPS 100% AUTOMATED STEPS CONNECT CENTER FOCUS CAPTURE ANALYSE SAVE AND REPORT CONNECT CENTER FOCUS CAPTURE ANALYSE SAVE AND REPORT VOLLAUTOMATISCH Die einzigartige Autofokus-Funktion ermöglicht eine automatisierte Faser-Inspektion Das einzigartige Autofokus-System der FIP-430B automatisiert jede operation in der Testsequenz und macht dadurch aus der kritischen Steckerinspektion einen schnellen und einfachen Vorgang von nur einem Arbeitsschritt, den jeder ausführen kann. Opternus Vorlauffaser- & Reinigungs-Koffer Fragen Sie nach unseren maßgeschneiderten Lösungen für Inspektion und Reinigung. Einfluss verschmutzter Stecker auf die Übertragung 1. Einfluss auf höhere Datenraten bereits bei 10G und insbesondere bei 40G/100G In Rechenzentren oder z.B. Metro-Core-Netzen gibt es ein enges Dämpfungsbudget. 1 oder 2 dB Verlust durch einen verschmutzten oder beschädigten Stecker können bereits zu Fehlfunktionen führen. 2. Genereller Einfluss auf die Testergebnisse Da verschmutzte Stecker eine höhere Reflexion und Dämpfung ausweisen, werden die OTDR- oder OLTS- Messungen höhere Werte zeigen. Reinigung kann helfen den ORL zu begrenzen (z.B. Raman-Systeme). Verschmutzungen am Stecker be- einflussen IL und ORL ! Akzeptable Dämpfungswerte je Stecker bei 1310/1550nm sind: Kleiner 0,35 dB, kleiner -50dB Re- flektion bei PC, kleiner -65db bei APC 3. Einfluss auf OTN BER-Tests Schmutzige Stecker beeinflussen das Signal-Rausch-Verhältnis am Empfänger und erhöhen die BER. ANALYSIS SOFTWARE Übersicht der LWL-Mikroskope auf der Opternus-Homepage Quick Link (http:www...) WiFi-Inspektions-Probe Smartphone / Messgerät • Geeignet zum Prüfen von Steckern und Buchsen Sehr sicher, da kein direkter Augenkontakt Automatische Analyse und Anzeige auf Smart Device LWL-Inspektion & Reinigung 2018 USB-ANSCHLUSS USB + WIFI Eigenschaft / Modell Basis FIP-410B Halbautomat. FIP-420B Vollautomat. FIP-430B Halbautomat. FIP-425B Vollautomat. FIP-435B Drei Vergrößerungsstufen Bildaufnahmeknopf 5 Megapixel CMOS Aufnahmechip Automatische Bildzentrierung Autofokus Onboard Pass-/Fail-Analyse / Anzeige MPO/MTP-Stecker-Tests mit PIP WIFI und iOS- bzw. Android-App

Transcript of LWL-Inspektion & Reinigung 2018 - opternus.de · Beispiele für Einzelfaser Stecker (und viele...

Beispiele für Einzelfaser Stecker (und viele weitere...)FIP-400 Adapter Spitzen APC FIP-400 Adapter Spitzen UPC

Male Female Male Female

FIPT-400-U25MA

FIPT-400-SC-APC

SC Simplex (singlemode/multimode)

FIPT-400-U25M

FIPT-400-FC-SC

SC Duplex (singlemode/multimode)

FIPT-400-FC-APC

FC Simplex (singlemode/multimode)

N/A

ST Simplex (singlemode/multimode) FIPT-400-ST

FIPT-400-E2000-APC

E2000 Simplex (singlemode/multimode)

FIPT-400-E2000E2000 Duplex (singlemode/multimode)

FIPT-400-U12MA

FIPT-400-LX5-APC

LX-5 Simplex (singlemode/multimode)

FIPT-400-U12M

FIPT-400-LX.5LX-5 Duplex (singlemode/multimode)

FIPT-400-LC-APC

LC Simplex (singlemode/multimode)

FIPT-400-LCLC Duplex (singlemode/multimode)

N/A

MU Simplex (singlemode/multimode)

FIPT-400-MUMU Duplex (singlemode/multimode)

Mehrfaser SteckerFIP-400 Adapter Spitzen APC FIP-400 Adapter Spitzen UPC

Male Female Male Female

N/A

MT-RJ (2 �bers) (singlemode/multimode) FIPT-400-MTRJ

and a coupler FIPT-400-MTRJ

FIPT-400-MTPA2 and a coupler FIPT-400-MTPA2

MTP/MTPA/MPO (4, 8, 12 �bers)

(singlemode/multimode)

FIPT-400-MTP2 and a coupler FIPT-400-MTP2

FTTA SteckerFIP-400 Adapter Spitzen UPC

Male Female

Outdoor connector (ODC) 2 �bers (singlemode/multimode)

FIPT-400-ODC-S

FIPT-400-ODC-2PIN-P-K

Outdoor connector (ODC) 4 �bers (singlemode/multimode) FIPT-400-ODC-

4PIN-P-K

FTTH SteckerFIP-400 Adapter Spitzen UPC

Male Female

OptiTap ® (drop terminal with single �ber ports)1 �ber (singlemode/multimode)

FIPT-400-U25MAFIPT-400-OTAP-

APC

OptiSheat ® (drop terminal with multi�ber expansion port)Up to 12 �bers (singlemode) FIPT-400-U25MA

and FIPT-400-OTAP-MTP-APC

FIPT-400-OTAP-APC and FIPT-400-

OTAP-MTP-APC

OptiTip®

Up to 12 �bers (singlemode/multimode)FIPT-400-OTAP-MTP-APC

Mehrfaser Stecker Inspektion: Mit 3 Klicks alles erledigt!

Stecker

Stecker-Problematik Kriterien der LWL Steckerinspektion Steckerreinigung

Lösungen

Dank EXFOs leistungsfähiger Messgeräte-Plattformen, auf denen auch die Auswertesoftware ConnectorMax läuft,stehen integrierte Lösungen für Messtechnik, Inspektion,Auswertung nach IEC / IPC und Protokoll zur Verfügung.

Empfohlene Inspektions- und Reinigungsprozedur“Wenn die Steckerinspektion aufgrund von Defekten ein negatives Ergebnis bringt, muss der Stecker gereinigt werden und die Inspektion muss wiederholt werden”

Den Stecker immer 2x reinigen bevor man ihn tauscht.

TrockenreinigungEine mechanische Trockenreinigung ist immer der erste Schritt. Wenn nach 2 Reinigungs-versuchen die Verschmutzung immer noch vorhanden ist, probieren Sie eine hybride Reinigung.

Hybride Reinigung „Nassreinigung“Die „hybride Reinigung“ ist eine Kombination aus Nass- und Trockenreinigung. Im ersten Schrittwird der Stecker mit einer Reinigungs�üssigkeit gereinigt und im zweiten Schritt werden Rück-stände mit einem fusselfreien Tuch oder Tupfer entfernt.Wenn der Stecker nach dieser Prozedur die Kriterien immer noch nicht erfüllt, sollten Sie er-wägen, ihn auszutauschen.

Wie funktioniert die TrockenreinigungEinfacher als mit dem OCC geht es nicht:Nur den Stecker aufstecken und mit dem Reinigungs-tool einen leichten Druck ausüben, bis ein Klicken zu hören ist - fertig. Das funktioniert auch im Patch-Feld durch die Kupplung hindurch.Für Mehrfaser-Stecker gibt es spezielle Reiniger.

Standardisierte Kriterien• IEC 61300-3-35

Fiber-optic interconnecting devices and passive components—basic test andmeasurement procedureshttp://webstore.iec.ch/

A N A L Y S I S S O F T W A R E

„Was du in Vorsorge investierst, zahlt sich 10-fach aus!“Die meisten Probleme in Glasfasernetzen werden durch verschmutzte Stecker verursacht!

• Mehrfaser Stecker werden in verschiedenen Anwendungen eingesetzt,zum Beispiel FTTH, Datacenter, ROADM etc.

Gängige Typen sind PTM ,OPM®* und OptiTip®*•

* MTP is a registered trademark of US Conec and OptiTip is a registered trademark of Corning Cable Systems

Erfüllt diezulässigen

Kriterien?

Nein

Nein

Nein

Ja

Ja

Ja

Fehlerwegen

Kratzern?

Fehlerverringert

?

AnzahlKratzer

und Fehler

Fehler wg.Schmutz

Prü�ingbesteht nicht

Prü�ingbesteht

Ende

Steckerreinigen

Start

AnzahlKratzer

und Fehler

3

1

2

Führungsstifte/-löcher

Optische Faser

Ferrule

Optische Mikroskope Nur für „männliche“ Stek-

ker geeignet (keine Buchsen) •

Nicht 100%ig sicher bei inBetrieb be�ndlichen Netzen. •

Risiko der Augenverletzungdurch Laserlicht. •

Wo prüfen/reinigenFolgende Dinge sollten immer auf IhrerInspektions- und Reinigungsliste stehen:

h-Feld ( z.B. Splitter, Schaltschrank)ctaP •

repmuJ tseT •

Wann reinigen Der allererste Schritt ist die Stecker-Inspektion. Das gilt für alle Testphasen – Konstruktion, Inbetriebnahme und Wartung. Stecker sollten nur gereinigt werden, wenn sich bei der Inspektion herausstellt, dass Sieschmutzig sind.

Wie prüfen1. Verbinden Sie das Mikroskop mit dem Stecker und

wählen Sie den entsprechenden IEC Standard.

2. Stellen Sie die maximale Vergrößerung ein

3. Starten Sie die Analyse mit dem Capture Knopf.

4. PrüfenSie die Pass-Fail-Anzeige an der FIP od. am Monitor

. Reinigen oder ersetzen Sie den Stecker abhängig vom Resultat.

5

6. Speichern Sie den Report.

Faser-Inspektions-Probe mit FTB Plattform

• Arbeitet mit dem Display derPlattform

• Speichert Bilder zu Referenz-Zwecken

• Leistet eine automatischeBildauswertung

Patch Panel-Prüfung (durch die Buchse)

2

4

3

FIP-Lösungen -- Test Möglichkeiten tabellarisch

Komfortable Faser Inspektions Test Kits

Staub- und Schmutz-Rückstände• Wenn nicht sorgfältig gereinigt wird, können

Rückstände übertragen werden und beimStecken sogar dauerhafte Schäden verursachen.

Feuchte Rückstände• Meistens durch eine ungeeignete Reinigungs- methode verursacht — die Stecker müssen

nach einer Nassreinigung sorgfältig getrocknetwerden.

Ölige Rückstände

Kreisrunde Rückstände• Meistens durch eine ungeeignete Reinigungs- methode verursacht.

• Entsteht, wenn noch nass gesteckt wird.

• Tritt typischerweise im Kontaktbereich auf.

• Die Verunreinigungen werden von dem einenauf den anderen Stecker übertragen.

Defekte in der Kleberegion• Kann schon im Herstellungsprozess entstehen

oder durch falsche Handhabung.

• Epoxy-Rückstände oder Chips können in dieserRegion aftreten.

• Akzeptabel innerhalb der Standards.

Schmutziger/beschädigter Stecker• Entsteht meist durch falsche Handhabung

oder Fehler beim Reinigen.

• Auch wenn die Fehler klein erscheinen mögen,können Sie trotzdem unzulässig sein.

Kratzer• Können als helle oder dunkle Fehler erscheinen.

• Sind mit bloßem Auge möglicherweise nicht zuerkennen.

• Kritisch, wenn im Kernbereich.

Vor der Reinigung

Nach der Reinigung

Patch Panel

Patch Panel

N. d. Trocknen

Eine Steckerend�äche hat verschiedene Zonen

e Stecker haben unterschiedlich große Bereiche.domelgniS dnu edomitlu• M

• Größen sind abhängig von Stecker- und Fasertyp

Core (0-65 μm) Core (0-25 μm)

Cladding (65-120 μm) Cladding (25-120 μm)

Adhesive (120-130 μm) Adhesive (120-130 μm)

Contact (130-250 μm) Contact (130-250 μm)

Beispiel für ein Reinigungskit(optional)

FTB-1 Überzug(o�en)

FTB-1 Überzug(geschlossen)

Beispiel für ein Reinigungskit(optional)

OCC - mechanische Reinigung vonEinzelfaser-Steckern (male/female)

Mechanischer Reiniger für Mehrfaser-Stecker (MTP/MPO)(male/female)

Cletop - mechanische Reinigung von Patch-Kabeln

LWL-Reinigungsmaterial auf der Opternus-Homepage

Quick Link (http:www...)

TK-1 / TK-2-FIP-400B

Auf Basis der leistungsfähigen Plattformen FTB-1, FTB-2 und sogar des MaxTesters, kombiniertdieses Test Set eine Fiber Inspection Probe mit einem großen 7-Zoll Display, integriertem opti-schen Leistungsmessgerät und Visual Fault Locator (VFL).Damit kombinierbar ist die ConnectorMax 2 Software zur automatisierten Pass-/Fail-Bewertungder Steckerend�ächen sowie eine komplette IP-Service Test Suite.

IEC Zonengrößen von PC Steckern mit Multimode Fasern IEC Zonengrößen von PC Steckern, Singlemode non-dispersion shifted Faser, RL ≥45 dB

• LWL-Stecker

• Häufig durch Anfassen verursacht.

• Ein öliger Rückstand kann wie ein MatchingGel wirken.

• Beeinflusst möglicherweise IL/RLnicht kurzfristig. ABER kann Staub anziehenund IL/RL negativ beein�ussen.

ConnectorMax 2 Analyse Software

• Unter Anwendern innerhalb einer Firma• Zwischen Ausrüster und Kunden• Zwischen Dienstleister und Netzbetreiber

• Garantiert einheitliche Bewertungskriterien

• Einfache Entscheidungsfindung ohne subjektive Einflüsse

Mühelose Steckerinspektion

Um Mehrfaser Stecker zu untersuchen, wird ein besonderes Inspektions-Tool benötigt. Der neue Mehrfasersteckeradapter von EXFO hat einen Revolverabzug um durch die einzelnen Fasern zu springen - auf diese Weise kann keine Faser übersehen werden!

Für die verschiedenen Typen von Mehrfasersteckern werden entsprechende Adapteraufsätze angeboten, jeweils für Grad- und Schrägschliff. Die schlanke Bauform ermöglicht es auch in engen Umgebungen, wie im Rechenzentrum, an die Stecker bzw. Buchsen heranzukommen, wasmit Lösungen anderer Hersteller oft nicht gelingt. Pass/Fail wird direkt an der Probe angezeigt und die Steckerbilder werden an das Smartphone oder einen Computer übertragen.

6

1

StandardInspection

Test Sequence

FIP-430B Inspection

Test Sequence

MANUALSTEPS

100%AUTOMATEDSTEPS

CONNECT CENTER FOCUS CAPTURE ANALYSE SAVE ANDREPORT

CONNECT CENTER FOCUS CAPTURE ANALYSE SAVE ANDREPORT

VOLLAUTOMATISCH

Die einzigartige Autofokus-Funktion ermöglicht eine automatisierte Faser-InspektionDas einzigartige Autofokus-System der FIP-430B automatisiert jede operation in der Testsequenzund macht dadurch aus der kritischen Steckerinspektion einen schnellen und einfachen Vorgang vonnur einem Arbeitsschritt, den jeder ausführen kann. Opternus Vorlauffaser- & Reinigungs-Koffer

Fragen Sie nach unseren maßgeschneiderten Lösungen für Inspektion und Reinigung.

Ein�uss verschmutzter Stecker auf die Übertragung1. Ein�uss auf höhere Datenraten bereits bei 10G und insbesondere bei 40G/100GIn Rechenzentren oder z.B. Metro-Core-Netzen gibt es ein enges Dämpfungsbudget. 1 oder 2 dB Verlustdurch einen verschmutzten oder beschädigten Stecker können bereits zu Fehlfunktionen führen.

2. Genereller Ein�uss auf die TestergebnisseDa verschmutzte Stecker eine höhere Re�exion und Dämpfung ausweisen, werden die OTDR- oder OLTS-Messungen höhere Werte zeigen. Reinigung kann helfen den ORL zu begrenzen (z.B. Raman-Systeme).

Verschmutzungen am Stecker be-ein�ussen IL und ORL !

Akzeptable Dämpfungswerte jeStecker bei 1310/1550nm sind:Kleiner 0,35 dB,kleiner -50dB Re-�ektion bei PC,kleiner -65db beiAPC

3. Ein�uss auf OTN BER-TestsSchmutzige Stecker beein�ussen das Signal-Rausch-Verhältnis am Empfänger und erhöhen die BER.

A N A L Y S I S S O F T W A R E

Übersicht der LWL-Mikroskope auf der Opternus-Homepage

Quick Link (http:www...)

AA RR EE

WiFi-Inspektions-Probe Smartphone / Messgerät• Geeignet zum Prüfen von

Steckern und Buchsen

• Sehr sicher, da kein direkterAugenkontakt

• Automatische Analyse und Anzeige auf Smart Device

WiFi-Inspektions-Probe -Inspektions-Probe Smartphone / MessgerätSmartphone / MessgerätSmartphone / Messgerät

Um Mehrfaser Stecker zu untersuchen, wird

Pass/Fail wird direkt an der Probe angezeigt und die Steckerbilder werden an das Smartphone oder einen Computer übertragen.werden an das Smartphone oder einen Computer übertragen.

LWL-Inspektion & Reinigung 2018

USB-ANSCHLUSS USB + WIFI

Eigenschaft / Modell BasisFIP-410B

Halbautomat.FIP-420B

Vollautomat.FIP-430B

Halbautomat.FIP-425B

Vollautomat.FIP-435B

Drei Vergrößerungsstufen ● ● ● ● ●

Bildaufnahmeknopf ● ● ● ● ●

5 Megapixel CMOS Aufnahmechip ● ● ● ● ●

Automatische Bildzentrierung – ● ● ● ●

Autofokus – – ● – ●

Onboard Pass-/Fail-Analyse / Anzeige – ● ● ● ●

MPO/MTP-Stecker-Tests mit PIP – – ● ● ●

WIFI und iOS- bzw. Android-App – – – ● ●