LV live feeder and phase identifier
-
Upload
al-buraq-hardware-tools-llc -
Category
Technology
-
view
258 -
download
2
description
Transcript of LV live feeder and phase identifier
![Page 1: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/1.jpg)
LV Live Feeder and Phase Identifier FC3000
![Page 2: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/2.jpg)
LV Live Feeder and Phase Identifier FC3000
![Page 3: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/3.jpg)
Line Unit leadsCentral Unit leads
Heavy duty case
Illustrated operating instruction in the lid Display on LCD screen with
a choice of many languages
Fuse protection on Central Unit (CU) and Line Unit (LU)
Fused leads
Fuse leads
Up to 12 Circuits/feeders
IP2X probes
LV Live Feeder and Phase Identifier FC3000
![Page 4: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/4.jpg)
■ Functions of the LV Live Feeder and Phase Identifier
This device can be used by a single operator for mapping customer phase and feeder connection in 5 seconds.
Which are compulsory information to enable Smart Meters communication. Applications : Helps to balance the
loads on the phases of the low voltage network.
Simple to use : The Central Unit (CU) is connected to all the outgoing lines on a supply substation. The Line Unit (LU), connected to any points of the network (customer, connection box, …), automatically provides you with all the useful information : Local voltage measurement
Phase indication : L1, L2 or L3 Feeder or circuit : From 1 to 6 (9 or 12) Substation (CU code) : Form 1 to 8 Didactic operating mode on the Central
Unit Category IV device protected by HRC fuses Insulated connection accessories Built-in self-test Thanks to the CU unit code it is possible to
use simultaneously several CUs located in several substations.
LV Live Feeder and Phase Identifier FC3000
![Page 5: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/5.jpg)
■ Specifications of the LV Live Feeder and Phase Identifier
Central Unit FC3000 UC Nominal voltage (phase-neutral) : 115 Vrms to 230
Vrms 200 Vrms to 400 Vrms between phases Maximum rated voltage : 440 Vrms (between phases, and
between phase en neutral) Minimum operating voltage : 200 Vrms between phases Network frequency : 50 or 60 Hz Input plugs L1-L2-L3-Neutral : Ø 4mm male IP2X (at the end
of the power lead) Functions : automatic and manual modes menus available in
6 languages Inputs protection : fast-acting HRC fuses in the housing and
at the leads connecting points Overvoltage category : 1000 V – Cat. IV Enclosure protection : IP51 (IP67 in closed case) Dimensions : 300 x 230 x 85mm Weight : 2.35 kg Detection coils : 6 for FC30006, 9 for FC30009, 12 for
FC300012 Identification : by colour coded ring (s) Loop diameter : Ø 120 mm
Line Unit : FC3000 UL Nominal voltage : 230 Vrms (between phase and neutral
terminals) Power supply : 4 alkaline batteries 1.5 V AA Autonomy : over 1000 detections Inputs protection : fast-acting HRC fuses in the housing and at
the IP2X leads connecting points Overvoltage Category : 1000 V – Cat. IV Enclosure protection : IP54 Approximate dimensions : 250 (235) x 130 x 65 mm Protection : shockproof rubber-type shell case Weight : 1.4 kg with shell case, lead, test probes and alligator
clips Complete unit
• Synthetic carry and storage case, IP67 when closed• Operating temperature : from 0°C to + 40°C / Hygrometry <
90 % non condensing.• Storage and transport temperature : from -20°C to + 70°C.
LV Live Feeder and Phase Identifier FC3000
![Page 6: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/6.jpg)
■ Standard and Environment
CE marking: Compliant with European Directives EMC Directive (Electro Magnetic Compatibility) 89/336/EEC, 92/31/EEC,
93/68/EEC et 92-587/RF, 95-283/RF, standard EN 55011 edition 2009 + A1/2010
Low Voltage Safety Directive (Safety of low-voltage equipment ) 73/23/EEC et 75-848/RF standard IEC/EN 61010-1 ed. 3.0 (2010-06) IEC/EN 61010-031 ed.1.1 (2008-06)
LV Live Feeder and Phase Identifier FC3000
Smart Meter friendlyNo perturbations for CLC signalsCompliant with standard requirements EN
50065-1 edition 07-2012
![Page 7: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/7.jpg)
All our products help utilities to face global challenges providing high safety level for electrical network improvement operations:Preparation / safetyEfficiency / Availability
THE NETWORK WILL CHANGE !
![Page 8: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/8.jpg)
THE NETWORK WILL CHANGE !
![Page 9: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/9.jpg)
THE NETWORK WILL CHANGE !
![Page 10: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/10.jpg)
Work in total confidence
with your powernetwork
![Page 11: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/11.jpg)
HISTORY & FIGURES
1949: creation of the company to supply earthing devices to “compagnie du Rhin”
1960: creation of the French LiveW competence Center (SERECT) in Mulhouse
1989: building of this building specialy designed around high voltage laboratory
1998: integration in Novarc Group 4800 m², 3500 references, TOP80% 1500 ref / 40 products 330 suppliers, 2M components, 200k end products ISO 9002 in 1996, ISO 9001 since 2002 Export rate > 65% in more than 100 countries
![Page 12: LV live feeder and phase identifier](https://reader033.fdocuments.net/reader033/viewer/2022061507/558e70891a28ab5e638b4644/html5/thumbnails/12.jpg)
For Sales: [email protected]