8/17/2019 Luse Volume http://slidepdf.com/reader/full/luse-volume 1/36 HP StorageWorks XP24000 LUN Expansion User's Guide Part number: T5214–96005 First edition:  June 2007

Transcript of Luse Volume

Page 1: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 1/36

HPStorageWorks

XP24000LUNExpansionUser'sGuide

Part

number:

T5214–96005

First

edition:

 June

2007

Page 2: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 2/36

Legalandnotice information

©Copyright2007Hewlett-Packard DevelopmentCompany,L.P.

Confidential

computer

software.

 Valid

license

from

HP

required

for

possession,

use

or

copying.

Consistent

with

FAR

12.211

and

12.212,CommercialComputerSoftware,ComputerSoftwareDocumentation,andTechnicalData forCommercial Itemsare

licensed to theU.S.Governmentundervendor'sstandardcommercial license.

The

information

contained

herein

is

subject

to

change

without

notice.

The

only

warranties

for

HP

products

and

services

are

set

forth

in theexpresswarrantystatementsaccompanyingsuchproductsandservices. Nothinghereinshouldbeconstruedasconstituting

an

additional

warranty.

HP

shall

not

be

liable

for

technical

or

editorial

errors

or

omissions

contained

herein.

Microsoft,

 Windows,

and

 Windows

XP

are

U.S.

registered

trademarks

of

Microsoft

Corporation.

Export

Requirements

You

may

not

export

or

re-export

this

document

or

any

copy

or

adaptation

in

violation

of

export

laws

or

regulations.

 Without limiting the foregoing, thisdocumentmaynotbeexported,re-exported, transferredordownloaded toorwithin (or to

a

national

resident

of)

countries

under

U.S.

economic

embargo,

including

Cuba,

Iran,

North

Korea,

Sudan,

and

Syria.

This

list

is

subject

to

change.

Thisdocumentmaynotbeexported,re-exported, transferred,ordownloadedtopersonsorentities listedon theU.S.DepartmentofCommerceDeniedPersonsList,EntityListofproliferationconcernoronanyU.S.TreasuryDepartmentDesignatedNationals

exclusion

list,

or

to

parties

directly

or

indirectly

involved

in

the

development

or

production

of

nuclear,

chemical,

biological

weapons,

orinmissile technologyprogramsasspecifiedin theU.S.Export AdministrationRegulations(15CFR744).

RevisionHistory

Edition

Date Description

First  June2007 This

edition

applies

to

microcode

version

60-01-31-00/00

or

later.

Page 3: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 3/36

Contents

 About this Guide

. . . . . . . . . . . . . . . . . . . . . . . . . .

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  

Conventions for Storage Capacity Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  

 Window Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  

HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  

Subscription Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  

HP Websites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  

Documentation Feedback   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 

1 About LUSE Operations . . . . . . . . . . . . . . . . . . . . . 11  

Overview of HP StorageWorks XP LUN Expansion (LUSE) . . . . . . . . . . . . . . . . . . . . 11  

LUSE Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  

LUSE Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12 LUSE Operations Using a Path-defined LDEV   . . . . . . . . . . . . . . . . . . . . . . . .

13 

2 Preparing for LUSE Operations

. . . . . . . . . . . . . . . . . .

15 

System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  

Preparing to Use LUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  

3 Using the LUSE GUI . . . . . . . . . . . . . . . . . . . . . . . 17 

LUN Expansion Window

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17 

LDEV Information Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  

LDEV Detail Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  

LDEV Operation Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  

4 Performing LUSE Operations

. . . . . . . . . . . . . . . . . . .

21 

Launching LUN Expansion (LUSE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  

 Viewing Concatenated Parity Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21 

Creating a LUSE Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  

Creating a LUSE Volume from the LDEV Detail Table . . . . . . . . . . . . . . . . . . . . 22  

Creating a LUSE Volume from the LDEV Operation Detail (Select an LDEV Combo Box)   . . . . . . 24 

Creating a LUSE Volume Using the Volume Count Combo Box . . . . . . . . . . . . . . . . 24  

Resetting an Unregistered LUSE Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25  

Releasing a LUSE Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  

Changing LUSE Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  

Displaying a List of Volumes Combined into a LUSE Volume . . . . . . . . . . . . . . . . . . . 28  

5 Troubleshooting   . . . . . . . . . . . . . . . . . . . . . . . . .

31 Troubleshooting LUN Expansion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  

Calling HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  

 A Glossary, Acronyms, and Abbreviations . . . . . . . . . . . . . . 33  

Index

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35 

XP24000 LUN Expansion User's Guide

3

Page 4: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 4/36

Figures 

LUSE Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  

LUSE Window  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  

Concatenation List Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . 22  

Set LUSE Confirmation Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . 23  

Reset LUSE Confirmation Dialog Box

. . . . . . . . . . . . . . . . . . . . . . .

26 

Release LUSE Confirmation Dialog Box . . . . . . . . . . . . . . . . . . . . . . 27  

LUSE Detail Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29  

4

Page 5: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 5/36

Tables 

Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8  

Specifications and Restrictions on LDEVs Used to Configure a LUSE Volume   . . . . . . . 12  

Specifications and Restrictions on LDEVs Released from a LUSE Volume . . . . . . . . 13 

LDEV Status Icons

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18 

Glossary, Acronyms, and Abbreviations . . . . . . . . . . . . . . . . . . . . . . 33  

XP24000 LUN Expansion User's Guide

5

Page 6: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 6/36

Page 7: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 7/36

 About

this

Guide 

Thisuser'sguideprovidesinstructionsforusingtheLUNExpansionoptionon theHPstoragesystem.

The termstorage system inthisguiderefers toanHPStorageWorksXP24000Disk Array.

Intended Audience

Thisdocumentassumes the following:

•  Theuser is familiarwith theoperatingsystemandwebbrowsersoftwareon thesystemhosting

theRemote Web

Console software.

•  Theuserhasabackground indataprocessingandunderstandsRAIDstoragesystemsand

their basic functions.

•  TheuserisfamiliarwiththestoragesystemandhasreadandunderstandstheHP StorageWorks

XP24000 Disk  Array Owner'sGuide  for thestoragesystem.

Related

Documentation

•  HP StorageWorksXP24000  Audit LogUser and Reference Guide 

•  Hitachi Cache Manager User’sGuide 

•  HP StorageWorksXP24000 Cache Residency Manager User’sGuide 

•  HP StorageWorksXP RAID Manager User'sGuide 

•  HP StorageWorksXP24000 for Compatible Parallel  AccessVolumesSoftware User’sGuide 

•  HP StorageWorksXP24000 for Compatible Extended Remote Copy (XRC)Software User’sGuide 

•  HP StorageWorksXP24000 Snapshot User’sGuide 

•  HP StorageWorksXP24000 DataRetentionUtility User’sGuide 

•  Hitachi Dataset Replication for  IBMz/OSUser’sGuide  forHPStorageWorksLogical Volume

Divider software

• 

HP 

StorageWorks

XP 

Logical 

Volume 

Divider 

User's

Guide 

•  HP StorageWorksXP24000 for FlashCopy MirroringSoftware User’sGuide 

•  HP StorageWorksXP24000 LUN ExpansionUser’sGuide 

•  HP StorageWorksXP24000 LUN Manager User’sGuide 

•  HP StorageWorksXP24000 Performance Monitor User’sGuide 

•  HP StorageWorksXP24000  Auto LUN Software User’sGuide 

•  HP StorageWorksXP24000 BusinessCopy Software User'sGuide 

•  Hitachi ShadowImage  for z/OS User’s Guide 

•  HP StorageWorksXP24000 SNMP  Agent Reference Guide 

•  HP StorageWorksXP24000 Remote Web Console Error Codes

•  HP StorageWorksXP24000 Continuous AccessSoftware User and Reference Guide 

• 

Hitachi 

TrueCopy 

for 

z/OS

User 

and 

Reference 

Guide •  HP StorageWorksXP24000 Continuous Access Journal Software User and Reference Guide 

•  Hitachi Universal  Replicator  for z/OS User and  Reference Guide 

•  HP StorageWorksXP24000 External Storage Software User’sGuide 

•  HP StorageWorksXP24000 Disk  Array Owner'sGuide 

•  HP StorageWorksXP24000 Virtual LVI/LUN (VLL)and Volume Shredder User’sGuide 

•  HP StorageWorksXP24000 Disk/Cache PartitionUser’sGuide 

XP24000 LUNExpansionUser'sGuide

7

Page 8: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 8/36

• HP StorageWorksXP24000 Volume RetentionManager User’sGuide 

• HP StorageWorksXP24000 Volume Security User’sGuide 

You can findrelatedHPStorageWorksdocuments from theManualspageof theHPBusinessSupportCenter website:

http://www.hp.com/support/manuals. 

In

the

Storage

section,

click

Storage

Software

and

then

select

the

product. 

Document

ConventionsTable 1 Document Conventions

Convention Element

Blue text: Table1 Cross-reference linksande-mailaddresses

Blue,underlined text:

http://www.hp.com

 Websiteaddresses

Bold text• Text emphasis

• UIelements

Conventions

for

Storage

Capacity

 Values

HPXPstoragesystemsuse the followingvalues tocalculatephysicalstoragecapacityvalues (hard

disk drives):

• 1 KB (kilobyte) = 1,000 bytes

• 1 MB (megabyte) =1,0002 bytes

• 1 GB (gigabyte) =1,0003 bytes

• 1 TB (terabyte)= 1,0004 bytes

HPXPstoragesystemsuse the followingvalues tocalculate logicalstoragecapacityvalues (logicaldevices):

1 KB (kilobyte) = 1,024 bytes

• 1 MB (megabyte) = 1,0242 bytes

• 1 GB (gigabyte) =1,0243 bytes

• 1 TB (terabyte) = 1,0244 bytes

• 1 block = 512 bytes

 Window Illustrations

The

windows

shown

in

this

guide

were

displayed

on

a

 Windows

computer

with

the

Internet

Explorer

browser. Thewindowsmayappeardifferentonyourcomputerdependingon theoperatingsystem

andbrowserbeingused. Windowcontentsalsovarydependingon installedprogramproductsand

the storagesystem beingmanaged.

HPTechnicalSupportForworldwide technicalsupport information,see theHPsupportwebsite:

http://www.hp.com/support

BeforecontactingHP,collect the following information:

• Productmodelnamesandnumbers

8  About this Guide

Page 9: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 9/36

• Technicalsupportregistrationnumber (ifapplicable)

• Product serial numbers

• Error messages

• Operatingsystem typeand revision level

• Detailed questions

Subscription

Service

HP

recommends

that

you

register

your

product

at

the

Subscriber’s

Choice

for

Business

website:

http://www.hp.com/go/e-updates

 After

registering,

you

will

receive

e-mail

notification

of

product

enhancements,

new

driver

versions,

firmwareupdates,andotherproductresources.

HP

 Websites

Foradditional information,see the followingHPwebsites:

•   http://www.hp.com

•   http://www.hp.com/go/storage

•   http://www.hp.com/service_locator

•   http://www.hp.com/support/manuals

DocumentationFeedback

HPwelcomesyour feedback.

To make comments and suggestions about product documentation, send a message to

[email protected]. Allsubmissionsbecome thepropertyofHP.

XP24000 LUNExpansionUser'sGuide

9

Page 10: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 10/36

10  About this Guide

Page 11: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 11/36

1 About

LUSE

Operations

Overview

of

HP

StorageWorks

XP

LUN

Expansion

(LUSE)

LUN

Expansion

(LUSE)

operations

allow

hosts

that

can

use

only

a

limited

amount

of

LUs

perfi

bre

interface

tohaveaccess to largeramountsofdatabyusingexpandedLUs.

LUSEFunction

LUNExpansion(LUSE) isafunctionforopensystems. Touse thisfunction,youneedthesoftwarecalled

Open VolumeManagement.

TheLUSE function isapplied toopen-system logicalvolumesandenablesyou toconfigureone large

logical

volume

by

combining

several

small

LDEVs.

The

LUSE

function

allows

hosts

that

can

use

only

a

limitednumberof logicalunits (LUs)perfibre interface tohaveaccess to largeramountsofdataby

using expanded LUs.

Figure1onpage 11 shows the LUSE configuration. ByusingtheLUSEfunction,youcancombineseveral

logical

devices

(LDEVs)

or

volumes

into

one

large

logical

volume.

The

size

of

the

confi

gured

LDEV

can

be

expandedupto36timesthesizeoftheoriginalLDEV.TheIDofthelogicalvolumedefinedasthelarge

logicalvolume isrepresentedby thesmallestLDEV ID(assigned to the topLDEV).Thehostrecognizes

theexpanded logicalvolumeasonerepresentativeLDEV. As longas thenumberofLDEVscombined

intoone large logicalvolumedoesnotexceed thespecified limit(seeTable2onpage12),youcan

arbitrarily

select

any

LDEVs

as

the

volumes

to

combine,

regardless

of

their

size

(or

capacity)

or

whether

ornot theyareon thesameCU(ControlUnit). TheLUSEfunctionalsoallowsyou tocombineseveralLDEVsandaLUSEvolume(combinedLDEVs) intooneLUSEvolumeorcombineLUSEvolumes togetherinto one

LUSE volume.

Before thehostcanaccesseachLDEVcomposinganexpandedLU (LUSEvolume),youmustrelease

the expanded LU.

LDEV (1:00)LUSE (1:00)

The host sees LUSEvolumes as one LDEV.

LDEV (1:01) 

Host  LDEV (1:03) 

LUSE (1:04) 

LDEV (1:04) 

LDEV (1:05)

Figure

1

LUSE

Configuration

Tocreateanopen-systemsvolume(LU) largerthan2.8TB,youmustuseLUSE tocombineopen-systems

volumesso thataLUSEvolume larger than2.8TB iscreated.

XP24000 LUNExpansionUser'sGuide

11

Page 12: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 12/36

 Whetherhostscanaccessavolume larger than2TBdependson theoperatingsystemsof thehosts.Hostsrunning thefollowingoperatingsystemscanaccessLUSEvolumeslarger than2TB:

•   AIX 5.2TL08or later

•   AIX 5.3 TL04 or later

•   WindowsServer 2003 SP1 or later

• RedHatEnterpriseLinux AS4Update1or later 

Cautions : 

• 

Other

operating

systems

do

not

support

LUs

larger

than

2

TB.

If

other

operating

systems

are

used

by

hosts,

make

sure

that

the

LUs

are

not

larger

than

2

TB.

•  For informationaboutthemaximumLUcapacitysupportedbyyouroperatingsystem,contactthe

vendorofyouroperatingsystem.

LUSEGuidelinesTable 2 onpage12 liststhespecifications and restrictions for LDEVs used to configureaLUSEvolume.Table

3

on

page13liststhespecificationsandrestrictionsforLDEVsreleasedfromaLUSEvolume.

Table

2

SpecificationsandRestrictionsonLDEVsUsedtoConfigureaLUSE Volume

No. Specifications and Restrictions

1

Open

volumes

(OPEN-3,

OPEN-8,

OPEN-9,

OPEN-E,

OPEN-L,

and

OPEN-V)

are

supported.

2

The

number

of

LDEVs

combined

into

a

LUSE

volume

must

be

within

the

range

of

2

to

36

(see

Note  1 ).

3 The emulation type of the LDEVs combined into a LUSE volume must be the same.

4

The RAID level of the LDEVs that are to be combined into LUSE volumes should be the same

(recommended) (seeNote  2 ).

5

LDEVsorLUSEvolumes thatare tobecombinedmustnothaveassignedpathdefinitions.For this reason, TrueCopy for Mainframe, HP StorageWorks XP Continuous Access Software,

ShadowImage for Mainframe, HP StorageWorks XP Business Copy Software, and HP

StorageWorksXPContinuous Access JournalSoftwarepairvolumescannotbe targetsofLUSE

operations(see“LUSEOperationsUsingaPath-definedLDEV” on page 13).

6

LDEVs thatare tobecombined intoLUSEvolumesmustnotbereserved forHPStorageWorksXP

 Auto

LUN

Software.

7

 WhenyoucombineaLUSEvolumewithanotherLUSEvolume, therangeofLDEVsshouldnotoverlap (see Note  3 ).

8 ThemaximumcapacityofaLUSEvolume is60TB(seeNote  4 ).

9 Combining

command

devices

into

a

LUSE

volume

is

not

supported.

10 Theaccessattributemustbeset toRead/Write.

11 Combininginternalvolumes,externalvolumes,andvirtualvolumes(V-VOLs)isnotsupported.

12  While online, the host mode must not be 0x0C [Windows] or 0x01 [VMWare].

13 Thecachemodesettings forLDEVscombinedintoaLUSEvolumemustbethesame.

14

 All LDEVs

combined

into

a LUSE volume must be of the

same

drive

type (however,

SATA

drives

andBD

drives

can

be

intermixed).

15 LDEVsarenotpoolvolumes (pool-VOLs).

16 LDEVsarenot journalvolumes.

17 LDEVs are

not system volumes.

12  About LUSEOperations

Page 13: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 13/36

Note  1:  ThenumberofexpandedLUs(LDEVs)shouldnotexceed36,even iftheLUSEvolumecontains

another LUSE volume.

Note  2:  CombiningRAID1andRAID5volumes into thesameLUSEvolume issupported,butnotrecommended.

Note  3:   IfyoucombineLDEV00,LDEV03,andLDEV05 intoLUSE1, LDEV02 and LDEV04 into LUSE2,andLDEV06andLDEV07 intoLUSE3,youcanalsocombineLUSE1andLUSE3. However,youcannotcombineLUSE1andLUSE2becausetheLDEVrangeinLUSE1andLUSE2overlaps.

Note  

4:  

 ALUSEvolumecontainsup to4MBofdiskarea tobeused forcontrolling thevolume,and

this

disk

area

cannot

contain

user

data.

Therefore,

the

maximum

capacity

for

user

data

in

a

LUSEvolume is less than60TB.

Table

3

Specifications

and

Restrictions

on

LDEVs

Released

from

a

LUSE

 Volume

No. Specifications and Restrictions

1 The LUSE volume must not have any definedpath.

2 The access

attribute must be set

to

Read/Write.

LUSE Operations Using a Path-definedLDEV

 WhenyoucreateaLUSEvolume, thetopLUSEvolumecanbeeitheranLDEVoraLUSEvolumethathas

one

or

more

paths

defined to it.

Only

the top

volume

in

the LUSE volume

to be created

can have anypaths. Theothervolumesin theLUSEvolume tobecreatedmustnothaveanypaths.

Note : You canperformaLUSEoperationusingapath-definedLDEVregardlessofhowmanypaths

are defined to the LDEV.

Note : Youcannotcombineapath-definedLDEVorLUSEvolumewithanotherpath-definedLDEV

or LUSE volume.

Note : When youstarttheLUSEoperationtocombineapath-definedLDEVorLUSEvolumewithanotherpath-definedLDEVorLUSEvolume,adialogboxwillappearwithamessageasking ifyouwant to

continue

the

operation.

Click

the

OK 

button

if

you

want

to

continue

or

the

Cancel

button

if

you

do

not.

Note thefollowingpointswhenyouperformaLUSEoperationusingapath-definedLDEV:

•  Caution : Ifapath isdefinedfroma Windows2000host,a WindowsServer2003host,oran

 AIX5.2

host

to

an

LDEV,

the

LDEV

can

be

used

for

LUSE

operations

using

a

path-defi

ned

LDEV.

However,ifapathisdefinedfromahostrunninganotheroperatingsystemtoanLDEV,theLDEV

cannotbeusedforLUSEoperationsusingapath-definedLDEV.

•  Caution : Ifapathisdefinedfroma Windows2000hostora WindowsServer2003hosttoan

LDEVandyouwant toperformaLUSEoperation thathandles thispath-definedLDEV,youmustensure that thehostmodeforthe Windowshost is2C(WindowsExtension). Ifthehostmodeis

not2C,youmustchange thehostmodeto2CbeforeperformingtheLUSEoperation.

XP24000 LUNExpansionUser'sGuide

13

Page 14: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 14/36

14  About LUSE Operations

Page 15: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 15/36

2

Preparing

for

LUSE

Operations 

Thischapterdescribes theenvironmentyouneed toprepare inordertooperateLUSE.

System

Requirements

TooperateLUNExpansion(LUSE),youneed the following items:

• HPstoragesystem(orsimplystoragesystemwhereapplicablehereafter)

• HPStorageWorksXPRemote WebConsolecomputer

• LicensedLUNExpansionsoftware

Note : To

use

the

LUSE

function,

you

need

the

software

called

Open

 Volume

Management.

Note

that

thissoftware isonly foropensystems.

Preparing

to

Use

LUSE

Before

starting

a

LUSE

operation

on

a

selected

storage

system,

make

sure

that

you

unmount

theopen-system

volumes

and/or

remove

the

LU

paths

to

the

open

volumes.

For

instructions

on

removing

LU

paths,seeHP StorageWorksXP24000 LUN Manager User’sGuide .

XP24000 LUNExpansionUser'sGuide

15

Page 16: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 16/36

16 Preparing for LUSEOperations

Page 17: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 17/36

3 Using

the LUSE GUI 

This

chapter

describes

the

GUI

for

LUN

Expansion

(LUSE)

operations.

LUN

Expansion

 Window

The following

is the LUN Expansion (LUSE) window. Later sections in this chapter explain

components of the LUSE window. For instructions on how to display this window, see

“LaunchingLUNExpansion (LUSE)”onpage21.

Figure

2

LUSE

 Window

LDEV

Information

Tree

•  The LDEV  Information tree ison the upper-leftcornerof theLUNExpansion tab. The LDEV

InformationtreedisplaystheLDKC(logicalDKC)andCUnumbersinstalledonthestoragesystem.

LDEV

Detail

Table

•  The

LDEV 

Detail table ison theupper-rightcornerof the

LUN

Expansion tab.

TheLDEVDetailtabledisplaysdetailedinformationforallopen-systemLDEVsintheselectedCU.The tabledisplays the following information:

•  LDKC:CU:LDEV  - LDEV status icon (see Table 4 onpage18)and theLDKC,CUandLDEV

numbers. If theselectedLDEV isaLUSEvolume, theLDEVnumberof the topLDEV in the

LUSE volume isdisplayed.

XP24000 LUNExpansionUser'sGuide

17

Page 18: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 18/36

Note:   AnLDEVnumber thatendswitha# indicates that theLDEV isanexternalvolume

(forexample,00:00:01#). Fordetailsregardingexternalvolumes,seeHP StorageWorks

XP24000 

External 

Storage 

Software 

User’s

Guide .

Note:   AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)forHPStorageWorksXPSnapshot(forexample,00:00:01V ).Fordetailsregarding

 V-VOLs,seeHP StorageWorksXP24000 Snapshot User’sGuide .Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL) forHPStorageWorksXPThinProvisioningSoftware (forexample,00:00:01X).

For details regarding V-VOLs, see HP StorageWorksXP24000 ThinProvisioningSoftware User’s Guide .

• 

Emulation

- Emulation

type.

If

the

selected

LDEV

is

a

LUSE

volume,

the

emulation

type

is

displayedwithanasteriskand thenumberofvolumes in theLUSEvolume (forexample,OPEN-E*5).

•  Capacity- LDEVcapacity,displayed ineitherMBorGB,dependingonwhichunit isselected

in theCapacityUnit box.

•  RAID - RAID levelof theLDEV.Note:TheRAID level is leftunspecifiedwithahyphen (-)when theLDEV isanexternalLU

orvirtualvolume (V-VOL).

•  PG- Paritygroup. IftheLDEVextendsovertwoormoreparitygroups,thePGcolumndisplays

the smallerparitygroupnumber.Note:   AparitygroupnumberthatstartswithaletterEindicatesthattheparitygroupconsists

ofoneormoreexternalLUs (forexample,E1-1).Note: 

 

 Aparitygroupnumber thatstartswithaletter Vindicatesthattheparitygroupconsists

of

one

or

more

virtual

volumes

(V-VOLs)

for

XP

Snapshot

(for

example,

 V1-1).Note : AparitygroupnumberthatstartswithaletterXindicatesthattheparitygroupconsists

ofoneormorevirtualvolumes(V-VOLs)forXPThinProvisioning. (forexample,X1-1).

•  Paths - Number ofpaths thatareset for theLDEV. If this column displays the numberof paths for an LDEV, you can use the LDEV as the top LDEV ofa LUSE volume (see

“LUSE

Operations

Using

a

Path-defined

LDEV”

on

page

13).

•   Access Attribute - Theaccessattribute that issetfor theLDEV.

•  Cachemode- Displays Disablewhen thecache isset tobeunused for responding toan

I/Orequestfrom thehost,orEnablewhen thecache isset tobeused forresponding toan

I/O request from the host.

• 

Ex-Dev

Info. - Displaysthedrivetypeofexternalvolumes. Displaysanasterisk(*)foraSATA

orBDdrivecontainingexternalvolumes. Nothing isdisplayed forFCdrivescontaining

external

volumes

and

drives

containing

internal

volumes.

•  Int. VOLInfo - Displays thedrivetypesofinternalvolumes. DisplaysnothingforanFCdrive

containinginternalvolumes. Displaysahyphen(-)foradrivecontainingexternalvolumes.

•  CLPR- The ID of the CLPR (cache logicalpartition) towhich thedisplayedvolumesbelong.TheCLPR ID isa two-digitnumber.

Table 4 LDEV Status Icons

Icon

LDEV 

status

NormalLDEV

Expanded(LUSE)volume

• 

Capacity

Unit

box

- Capacity

of

the

LDEV

displayed

in

the

Capacity

column,

in

either

GB

(defaultview) orMB.

•  SelectedLDEVs - NumberofLDEVsselected in theLDEVDetail table.

LDEVOperationDetail•  SelectanLDEV drop-downbox - LDEVsandLUSEvolumesoftheselectedCUthatareeligibleto

becomepartofaLUSEvolumearedisplayed. TheselectedLDEVnumberbecomesthetopLDEV

numberof a LUSEvolume.

18 Using the LUSEGUI

Page 19: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 19/36

•   VolumeCount drop-downbox - NumberofLDEVs that formaLUSEvolume.Forexample,ifyouselect3 inthe VolumeCountcombobox,threeLDEVsareexpectedtoforma

LUSEvolume,andthenthreeLDEVsareaddedtotheExpandedLDEVslist.Note:  

You can selectanLDEVonlyfromthe VolumeCountdrop-downbox. YoucannotselectaLUSEvolume.

•  ExpandedLDEVslist- LDEVsthatareselectedasLUSEvolumecomponents. AnLDEVisaddedto

this listwhen the<<Addbutton isselected (seebelow).

•  SelectedLDEVs- NumberofLDEVsselected in theExpandedLDEVs list.

•  Number ofLDEVs- NumberofLDEVsdisplayedin theExpandedLDEVslist.

• 

Size

- Total

capacity

of

the

LDEVs

displayed

in

the

Expanded

LDEVs

list,

in

either

GB

or

MB.

• 

Free

LDEVs

table

- LDEVs

or

LUSE

volumes

selected

in

the

Select

an

LDEV 

drop-down

box

that

areeligible tobecomepartofaLUSEvolume.Note: 

 

Thedrop-downlistsontheupper-rightoftheFreeLDEVstableenableyoutonarrowentries

in this table. IfyouselectanLDKCandaCU from theLDKCandCUdrop-down lists, theFree

LDEVs tabledisplaysonly theLDEVsbelonging to theselectedLDKCandCU.

•  LDKC:CU:LDEV : LDEV status icon (see Table4onpage18)and theLDKC,CU,andLDEV

numbers. If theselectedLDEV isaLUSEvolume, theLDEVnumberof the topLDEV in the

LUSE volume is displayed.Note:   AnLDEVnumber thatendswitha# indicates that theLDEV isanexternalvolume

(forexample,00:00:01#). Fordetailsregardingexternalvolumes,seeHP StorageWorks

XP24000 External Storage Software User’sGuide .Note:   AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)forXPSnapshot(forexample,00:00:01V ). Fordetails regarding V-VOLs, seeHP 

StorageWorks

XP24000 

Snapshot 

User’s

Guide .Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL)forXPThinProvisioning(forexample,00:00:01X).Fordetailsregarding V-VOLs,see

HP StorageWorksXP24000 ThinProvisioningSoftware User’sGuide .

•  RAID:RAID levelof theLDEV.Note:  TheRAID level is leftunspecifiedwithahyphen (-)when theLDEV isanexternalLU

or

virtual

volume

(V-VOL).

• 

PG:

Parity

group.

If

the

LDEV

extends

over

two

or

more

parity

groups,

the

PG

column

displays

thesmaller paritygroupnumber.Note:   Aparitygroupnumberthatstartswitha letterEindicates thattheparitygroupconsists

ofoneormoreexternalLUs (forexample,E1-1).Note:   A

parity

group

number

that

starts

with

a

letter

 V

indicates

that

the

parity

group

consists

ofoneormorevirtualvolumes(V-VOLs). (forexample, V1-1).

• 

CLPR:

The

CLPR

number.

For

detailed

information

about

CLPRs

(cache

logical

partitions),

seeHP StorageWorksXP24000 Disk/Cache PartitionUser’sGuide .

• 

Selected

LDEVs: NumberofLDEVsselected in the

Free

LDEVs table.

• 

<<Add - MovesaselectedLDEVfrom the

Free

LDEVs listto the

Expanded

LDEVslist.

• 

Delete>> - MovesaselectedLDEVfrom the

Expanded

LDEVslistto the

Free

LDEVs list.

•  Set - CreatesaLUSEvolumeconsistingofthevolumescurrently in theExpandedLDEVslist. The

newLUSEisdisplayedinblue  bold   italics  intheLDEV Detailtable(ontheupper-rightcornerofthe

LUNExpansiontab),but isnotactuallycreateduntilyouclickthe Applybutton.

•   Apply - Implements thesettings to thestoragesystem.

•  Cancel - Cancels the settings.

XP24000 LUNExpansionUser'sGuide

19

Page 20: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 20/36

20 Using the LUSE GUI

Page 21: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 21/36

4

Performing

LUSE

Operations

Launching

LUN

Expansion

(LUSE)

To

launch

LUN

Expansion:

1.  In the Remote Web Console main window, click Go, VolumeManager ,andthenLUNExpansion

on the menu bar.TheLUSEwindowappears. Thiswindowenablesyou toperformLUSEoperations.

Note:   To exit LUSE, click the Logout button in theupper-rightcornerof theRemote Web

Consolemain

window,orend the Webbrowser.

Ifyouaregoing to implementanychanges forLUNExpansion,youmusthavemodifypermissionforLUN Expansion.

You can view thecurrentLUSEconfigurationon theLUSEwindow(seeFigure2onpage17).

•  TheLDEV Information treedisplays theCUandLDEVnumbers installedon thestoragesystem

in ahierarchical structure.

• 

The

LDEV

Detail

table

displays

detailed

information

for

all

open-system

LDEVs

in

the

selected

CU.IfyouhaveselectedanormalLDEV,theinformationinthissectionisforthe topLDEV.Ifyouhave

selectedaLUSEvolume,the informationin thistableisforalloftheLDEVs in theLUSEvolume.Note:   AnLDEVnumber thatendswitha

# indicates that theLDEV isanexternalvolume (for

example,00:00:01#). Fordetailsregardingexternalvolumes,seeHP StorageWorksXP24000 External Storage Software User’sGuide .Note: 

 

 AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)(for

example,

00:00:01V ).

For

details

regarding

 V-VOLs,

see

HP 

StorageWorks

XP24000 

Snapshot User’sGuide .

 ViewingConcatenatedParityGroups

In thestoragesystem,datacanbewritten toanLDEV thatextendsoverconcatenatedparitygroups.

Concatenation

of

parity

groups

enables

faster

access

to

data.

To view aconcatenatedparitygroup:

1.  Makesure thatRemote WebConsole is inModifymode.Fordetailed informationaboutModifymode,see theHP StorageWorksXP24000 Remote Web  Console  User's Guide .

2.  SelectaCUnumberfrom theLDEV Information tree. TheLDEV Detail tabledisplaysallLDEVs

in the selected CU.

3.  In theLDEV Detail table,selectandright-click the freeLDEVs thatyouwant to form theLUSE

volume. Ifparitygroupsareconcatenated,thisdisplaystheConcatenationListpop-upmenu.Note : The ConcatenationListcommanddoesnot appear if theselectedLDEVdoesnot extend

over

concatenated

parity

groups.

4.  SelectConcatenationListtodisplaytheConcatenationListdialogbox(seeFigure3onpage22).

5. 

 When

you

are

finished

viewing

the

list,

click

OK 

(or

Cancel)

to

return

to

the

LUN

Expansion

tab.

XP24000 LUNExpansionUser'sGuide

21

Page 22: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 22/36

Figure 3 Concatenation

List

Dialog

Box

Note:  

 A

parity

group

number

that

starts

with

a

letter

E

indicates

that

the

parity

group

consists

of

one

or

moreexternalLUs (forexample,E1-1).

CreatingaLUSE Volume

WARNING:  LUSEcreationisadestructiveoperation. Moveand/orbackupyourdatabeforeproceeding.

There are

three ways to create a LUSE

volume:

•  UsingtheLDEV Detailtable (see “CreatingaLUSE VolumefromtheLDEVDetailTable” on page 22)

•  Using the LDEV Operation detail (Select an LDEV  combo box) (see

“CreatingaLUSE VolumefromtheLDEVOperationDetail(SelectanLDEVComboBox)”onpage24)

•  Using the  Volume Count combo box (see

“Creating

a

LUSE

 Volume

Using

the

 Volume

Count

Combo

Box”

on

page

24)

(recommended)

CreatingaLUSE Volumefrom theLDEVDetailTable

Tocreatea LUSEvolume from theLDEVdetail table:

1.  Makesure thatRemote WebConsole is inModifymode.For

detailed

informationaboutModifymode,see theHP StorageWorksXP24000 Remote Web  Console  User's Guide .

2.  SelectaCUnumberfrom theLDEV Information tree. TheLDEV Detail tabledisplaysallLDEVs

in the selected CU.

3.  IntheLDEV Detailtable,selectandright-clickthenormalLDEVsorLUSEvolumesthatyouwantto

form theLUSEvolume. Thisdisplays theSetLUSE Volumepop-upmenu.

4. 

Select

Set

LUSE

 Volume. A dialog box isdisplayed. If thedisplayeddialogboxasks ifyouwant toperformaLUSE

operationonavolume thathasapathdefinition,followstepabelow. If thedisplayeddialog

boxasks ifyouwant toperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,follow

step

b

below.

If

the

displayed

dialog

box

is

the

Set

LUSE

Confirmation

dialog

box,

follow step c below.

a.  ToperformaLUSEoperationonavolumethathasapathdefinition,clickOK . If a message

appearsandasks ifyouwanttoperformaLUSEoperation thatwillaffectmore thanone

SLPR

or

CLPR, go to step b. Ifthismessagedoesnotappear,go tostep5.

22 Performing LUSE Operations

Page 23: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 23/36

IfyoudonotwanttoperformaLUSEoperationonavolumethathasapathdefinition,click

Cancel. Youarereturnedtothepreviousdialogbox,andthenyoucanretrytheoperation.

b.  ToperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,clickOK . A

confirmationdialogboxappears. Then,go tostep5.Ifyoudonotwant toperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,clickCancel. Youarereturned to thepreviousdialogbox,and thenyoucanretry

the operation.

c.  Ifthedisplayeddialogbox istheSetLUSEConfirmationdialogbox,go tostep5.

5.  ClickOK  tocreate theLUSEvolume (orCancel).

Note :

The

new

settings

that

appear

in

the

window

in

blue  

bold   

italics  

are

not

yet

registered

tothestoragesystem. TheLUSEvolumesthathavebeencreatedbutarenotyetregisteredto the

storagesystem(thoseinblue  bold   italics )canberesettothestatetheywereinbeforetheywere

created (see“ResettinganUnregisteredLUSE Volume”onpage25).

6.  Click Apply (orCancel).

7.  ClickOK  (orCancel).

 Whenyouselectandright-click thefreeLDEVs thatyouwant toformaLUSEvolume in theLDEV Detailtable,

and

select

the

Set

LUSE

 Volume

pop-up

menu,

the

Set

LUSE

confirmation

dialog

box

appears.

Youcanverify that theLDEVs listed in theconfirmationdialogboxare the onesyouwant tocreate

a LUSE volume.

Figure 4 Set LUSE Confirmation Dialog Box

•  LUSEcomponents listThis listshows informationforLDEVs thatconstitute theLUSEvolume.

•  LDKC:CU:LDEV : This fieldshowsanLDEV icon. ThisfieldalsoshowsanLDKCnumber,a

CU number, andanLDEVnumber.Note:   AnLDEVnumber thatendswitha# indicates that theLDEV isanexternalvolume

(for

example,

00:00:01#).

For

details

regarding

external

volumes,

see

HP 

StorageWorksXP24000 External Storage Software User’sGuide .

Note:   AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)forXPSnapshot(forexample,00:00:01V ). Fordetails regarding V-VOLs, seeHP StorageWorksXP24000 Snapshot User’sGuide .Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL)forXPThinProvisioning(forexample,00:00:01X).Fordetailsregarding V-VOLs,see

HP StorageWorksXP24000 ThinProvisioningSoftware User’sGuide .

•  Emulation: This fieldshows theemulation type for theLDEV.

XP24000 LUNExpansionUser'sGuide

23

Page 24: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 24/36

•  Capacity: This fieldshows thecapacity for theLDEV.

•  OK  - Creates the LUSE volume.Click thisbutton toset theLUSEvolumeconfigurationfor theLDEVs in theLUSEcomponent list.TheLDEVsregisteredascomponentsof theLUSEvolumearedisplayed inblue 

 

bold   

italics  

in

the LDEV information list.

•  Cancelbutton

ThisbuttonisusedtocanceltheoperationtocreateaLUSEvolumeusingtheLDEVsinthelist.

CreatingaLUSE Volume from theLDEVOperationDetail (SelectanLDEV

Combo

Box)

To create a LUSEvolumefrom theLDEVOperationdetail(SelectanLDEV combobox):

1.  Makesure thatRemote WebConsole is inModifymode.Fordetailed informationaboutModifymode, see the HP StorageWorksXP24000 Remote Web  Console  U ser's Guide .

2.  Select a CU number from theLDEV  Information tree (in theupper-left cornerof theLUN

Expansion tab).

3.  Clickthear rowbutton in the

Select

an

LDEV drop-downbox(inthe lower-rightofthewindow).

For theLUSE,selectthefirstLDEVfrom theFreeLDEVs listthatdisplaysavailableLDEVs.Note:  Thedrop-down listsintheupper-rightof theFreeLDEVs listenableyou tonarrowentries

in

this

table.

If

you

select

an

LDKC

and

a

CU

from

the

LDKC

and

CU

drop-down

lists,

the

Free

LDEVs

table

displays

only

the

LDEVs

belonging

to

the

selected

LDKC

and

CU.

4.  SelectoneormoreadditionalnormalLDEVsorLUSEvolumesfortheLUSEvolume. Click<<Add

tomove theselectedLDEVsfrom theFreeLDEVs listto theExpandedLDEVslist.

5.  TodeleteanLDEVfrom theExpandedLDEVslistandmove itbackto theFreeLDEVs list,selectoneormorevolumes. ClickDelete>>.

6.  SelectSet. Adialogbox isdisplayed. If thedisplayeddialogboxasks ifyouwant toperformaLUSE

operationonavolumethathasapathdefinition,followstepabelow. If thedisplayeddialog

boxasks ifyouwant toperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,follow

step

b

below.

If

the

displayed

dialog

box

is

the

Set

LUSE

Confirmation

dialog

box,

follow step c below:

a.  To performaLUSEoperationonavolumethathasapathdefinition,clickOK . If a message

appearsandasks ifyouwanttoperformaLUSEoperation thatwillaffectmore thanone

SLPR

or

CLPR,

go

to

step

b.

If

this

message

does

not

appear,

go

to

step

7.IfyoudonotwanttoperformaLUSEoperationonavolumethathasapathdefinition,click

Cancel. Youarereturnedtothepreviousdialogbox,andthenyoucanretrytheoperation.

b.  ToperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,clickOK . A

confirmationdialogboxappears. Then,go tostep7.Ifyoudonotwant toperformaLUSEoperation thatwillaffectmore thanoneSLPRorCLPR,clickCancel. Youarereturned to thepreviousdialogbox,and thenyoucanretry

the operation.

c.  IfthedisplayeddialogboxistheSetLUSEConfirmationdialogbox,go tostep7.

7.  SelectOK  (orCancel).

Note : The

new

settings

that

appear

in

the

window

inblue 

 

bold   

italics  

are

not

yet

registered

to

thestorage

system.

The

LUSE

volumes

that

have

been

created

but

are

not

yet

registered

to

the

storagesystem(thoseinblue  bold   italics )canberesettothestatetheywereinbeforetheywere

created

(see

“Resetting

an

Unregistered

LUSE

 Volume”

on

page

25).8.  Click Apply (orCancel).

9.  ClickOK  (orCancel).

CreatingaLUSE VolumeUsing the VolumeCountComboBox

TocreateaLUSEvolumeusing the VolumeCountcombobox:

1. Makesure thatRemote WebConsole is inModifymode.

24 Performing LUSE Operations

Page 25: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 25/36

Fordetailed informationaboutModifymode,see theHP StorageWorksXP24000 Remote Web  Console  User's Guide .

2.  Select theCUnumber tocreatetheLUSEvolumefrom theLDEVinformation tree.

3.  Click thearrowbutton inSelectanLDEV .Select the topLDEVof theLUSEvolume from the

drop-down list.Theselected topvolumeappears in theExpandedLDEVslist. NormalLDEVsandLUSEvolumes

that can be used for a LUSE volume are displayed in the FreeLDEVs list.Note:  Thedrop-down listsintheupper-rightof theFreeLDEVs listenableyoutonarrowentries

in this table. IfyouselectanLDKCandaCUfrom theLDKCandCUdrop-down lists, theFree

LDEVs

table

displays

only

the

LDEVs

belonging

to

the

selected

LDKC

and

CU.

4.  Select thenumberofLDEVsneeded toformaLUSEvolumefrom the VolumeCountbox.TheExpandedLDEVs listdisplaysasmanyLDEVsasspecified in the VolumeCount box. Forexample,if3 isspecifiedin VolumeCount,threeLDEVsappearinExpandedLDEVs.Note:  YoucannotselectLUSEvolumesfrom the VolumeCount box. ToselectLUSEvolumes,selectLDEVs

from

Free

LDEVs, and

click

<<Add.

a. 

Select

normal

LDEVs

or

LUSE

volumes

from

Free

LDEVs

to

add

more

LDEVs

to

the

Expanded

LDEVs list,and then click<<Add.

b.  TodeleteLDEVsfrom theExpandedLDEVslist,select theLDEVsfrom theExpandedLDEVslist, and thenclickDelete>>.

5.  ClickSet. A dialog box is displayed. If the displayed dialog box asks if you wantto perform a LUSE operation on a volume that has a path definition (see

“LUSE

Operations

Using

a

Path-defined

LDEV”

on

page

13

for

the

details

on

this

operation),followstepabelow. If thedisplayeddialogbox is theSetLUSEConfirmationdialogbox (see

“Creating

a

LUSE

 Volume

from

the

LDEV

Detail

Table”

on

page

22),

follow

step

b

below.

a. 

If

the

displayed

dialog

box

asks

if

you

want

to

perform

a

LUSE

operation

on

a

volume

that

hasapathdefinition,clickOK . Amessageappearsand informsyou that thespecified

volumeswillbeexpandedtoaLUSEvolume. Next,go tostep6.Tocancel theLUSEoperation,click

Cancel. Thescreenwillreturn to thepreviousdialog

box,

and

then

you

can

retry

the

operation.

b.  Ifthedisplayeddialogbox istheSetLUSEConfirmationdialogbox,go tostep6.

6.  Tocreate the LUSE, clickOK .Theselected topLDEV isdisplayed (inblue  bold    italics ) as a

LUSE volume in the LDEV list.Note : The LUSE volumes that have been created but are not yet registered to the storage system

(thoseinblue  bold   italics )canberesetto thestate theywereinbeforetheywerecreated(see

“Resetting

an

Unregistered

LUSE

 Volume” on page 25).7.  Click Apply.

8. 

Click

OK 

(or

Cancel). 

ThesettingforthisLUSEoperation isregisteredfor thestoragesystem. 

Resetting

an

Unregistered

LUSE

 Volume

 WhenyoucreateaLUSEvolume,itwillremainhighlighted inblue  bold   italics  untilyouregisteritto the

storagesystembyclicking Apply. A LUSE volume in blue  bold   italics   indicates thatyoucanreset this

LUSE volume to thestate itwas inbefore itwascreated.

Note : This isafunctionthatallowsyoutoresetanunregisteredLUSEvolumetothestate itwasinbefore

itwascreated. However, itdoesnot allowyou to recoveranyLUSEvolumes thathavebeenreleased

already

to

the

state

they

were

in

before

they

were

created.

Therefore,

if

the

LUSE

volume

that

you

havecreated consists of any LDEVs (those in blue  bold    italics ) thathavepreviouslybeenreleased froma

differentLUSEvolume,yourLUSEvolumecanonlyberesetto thestate itwas inwhen theconstituting

LDEVswere released from thatdifferentLUSEvolume.

Theprocedure toput theunregisteredLUSEvolumeback to thestate itwas inbefore itwascreated

by using thisreset function isdescribedbelow.

1. 

Make sure that Remote Web Console is in Modify mode.

XP24000 LUNExpansionUser'sGuide

25

Page 26: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 26/36

Fordetailed informationaboutModifymode, see the HP StorageWorksXP24000 Remote Web  Console  User's Guide .

2.  Select a CU number from theLDEV  Information tree (in theupper-left cornerof theLUN

Expansion tab).TheLDEV Detail table(in theupper-rightcornerof theLUNExpansiontab)displaysallLDEVs

in the selected CU.

3.  Select anunregistered LUSEvolume (inblue  bold    italics ) in the LDEV Detail table (in the

upper-arightcorneroftheLUNExpansiontab). Right-click theselectedLUSEvolumetodisplay

apop-upmenu that includes theResetSelected Volumecommandused toexecute theLUSE

volume

reset

operation.

4. 

Select

Reset

Selected

 Volume.

 A dialog box to confirm theLUSEvolumeresetoperationwillappear.

5.  ClickOK on thedialogbox toconfirm theLUSEvolumeresetoperation.

Thesettingof aselected LUSE volume that isnot registeredyetwillbe reset to the state itwas in

before thisLUSEvolumewascreated,and theLUSEvolumesor theLDEVsconstituting theselected

LUSEvolume thathas justbeen resetwillappear in theLDEV Detail table (in theupper-rightcornerof theLUNExpansion tab).

Figure 5 Reset LUSE Confirmation Dialog Box

•  UnregisteredLUSE volume listThis

list

shows

the

LDEVs

created

in

a

LUSE

volume,

but

not

yet

registered

to

the

storage

system,

that you can reset to the state they were in before they were created.

•  LDKC:CU:LDEV : This fieldshowsanLDEV icon. ThisfieldalsoshowsanLDKCnumber,a

CU number,andanLDEVnumber.Note: 

 

 AnLDEVnumber thatendswitha

# indicates that theLDEV isanexternalvolume

(for

example,

00:00:01#).

For

details

regarding

external

volumes,

see

HP 

StorageWorks

XP24000 External Storage Software User’sGuide .Note: 

 

 AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)forXPSnapshot(forexample,00:00:01V ). Fordetails regarding V-VOLs, see HP StorageWorks

XP24000 

Snapshot 

User’s

Guide .

Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL)forXPThinProvisioning(forexample,00:00:01X).Fordetailsregarding V-VOLs,see

HP 

StorageWorks

XP24000 

Thin

Provisioning

Software 

User’s

Guide .

• 

Emulation: This fieldshows theemulation typeof theLDEV.

•  Capacity: This fieldshows thecapacityof theLDEV.

•  OK  button

ThisbuttonisusedtoresettheunregisteredLUSEvolumetothestateitwasinbeforeitwascreated.

• 

Cancel button

Thisbutton isused tocancel theresetLUSEoperation.

26 Performing LUSE Operations

Page 27: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 27/36

Releasing

a

LUSE

 Volume

WARNING:  ReleasingLUSEvolumesisadestructiveoperation. Moveand/orbackupyourdatabefore

proceeding. DeleteallSCSIpaths to theLUSEvolume thatyouwantreleased.

To release a LUSE volume:

1. 

Make

sure

that

Remote

 Web

Console

is

in

Modify

mode.

For detailed informationaboutModifymode,see theHP StorageWorksXP24000 Remote Web  Console  User's Guide .

2. 

Select

a

CU

number

from

the

LDEV 

Information

tree

(in

the

upper-left

corner

of

the

LUN

Expansiontab). The LDEV Detail table (in theupper-rightcornerof theLUNExpansion tab)displaysallLDEVs in theselected CU.

3.  SelectaLUSEvolume in theLDEV Detail table (in the upper-right corner of the LUNExpansiontab). Right-click the LUSE volume to display the ReleaseLUSE Volumepop-upmenu.

4.  ClickReleaseLUSE Volume.

5. 

The

Release

LUSE

 Volume

confirmation

dialog

box

displays.

 Verify

that

the

LUSE

volumes

listed

in theconfirmationdialogboxare theones thatyouwantreleased.

6.  ClickOK  (orCancel).

Note : Thenewsettingsappear in theLUNExpansion tab inblue  

bold   

italics , but are not yet

implemented.

7.  Click Apply in the

LUN

Expansion tab (orCancel).

8. 

Click

OK 

(or

Cancel).

Figure

6

Release

LUSE

Confirmation

Dialog

Box

Note:  

If theselectedLUSEvolumehasapathorifanyvolumeotherthanaLUSEvolumeisselected,this

dialog

box

lists

only

LDEVs

containing

a

LUSE

volume

to

be

released.

•  ListofLDEVscontainingaLUSEvolume tobereleased

This listshows theLDEVscontainingLUSEvolumes tobereleased.

• 

LDKC:CU:LDEV : This

field

shows

an

LDEV

icon.

This

field

also

shows

an

LDKC

number,

aCU number, andanLDEVnumber.

Note:   AnLDEVnumber thatendswitha# indicates that theLDEV isanexternalvolume

(forexample,00:00:01#). Fordetailsregardingexternalvolumes,seeHP StorageWorks

XP24000 External Storage Software User’sGuide .Note:   AnLDEVnumber thatendswitha letter V indicates that theLDEV isavirtualvolume

(V-VOL)forXPSnapshot(forexample,00:00:01V ). Fordetails regarding V-VOLs, seeHP StorageWorksXP24000 Snapshot User’sGuide .

XP24000 LUNExpansionUser'sGuide

27

Page 28: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 28/36

Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL)forXPThinProvisioning(forexample,00:00:01X).Fordetailsregarding V-VOLs,see

HP 

StorageWorks

XP24000 

Thin

Provisioning

Software 

User’s

Guide .

• 

Emulation: This fieldshows theemulation typeof theLDEV.

•  Capacity: This fieldshows thecapacityof theLDEV.

•  OK  button

ThisbuttonisusedtoreleasetheLUSEvolumeconfigurationinthereleaselist. ThereleasedLDEVs

aredisplayed inblue  bold   italics  in theLDEV information list.

•  Cancelbutton 

This

button

is

used

to

cancel

the

release

LUSE

operation. 

ChangingLUSECapacities

There

are

two

ways

to

change

the

capacity

of

a

LUSE

volume:

•  ExpandingLUSE capacities

To

expand

the

capacity

of

a

LUSE

volume,

select

the

LUSE

volume

that

you

want

to

expand,

and thenadd

LDEVsorLUSEvolumes; orfirst select LDEVs or LUSE volumes that you want

to add, and then select a LUSE volume to be expanded. For further information, see

“CreatingaLUSE Volume”onpage22.

•  Reducing LUSEcapacities

You cannot reduce

the

capacity

of

an

existing

LUSE

volume.

If

you

want

a

LUSE

volume

to

have

a

smaller

capacity,

you

must

first

release

the

LUSE

volume

(see“Releasing a LUSE Volume” on page 27), and then redefine the LUSE volume (see

“Creating

a

LUSE

 Volume” on page 22).

Displaying

a

List

of

 Volumes

Combined

into

a

LUSE

 Volume

 ALUSEvolume isacombinationofmultiplevolumes (LDEVs). Todisplaya listofvolumes thatare

combined intooneLUSEvolume, follow theprocedurebelow:

1.  Makesure thatRemote WebConsole is inModifymode.Fordetailed informationaboutModifymode, see the HP StorageWorksXP24000 Remote Web  Console  User's Guide .

2.  SelectaLUSEvolume in theLDEV Detail table (in theupper-rightcornerof theLUNExpansion

tab).

Right-click

a LUSE volume to display

a pop-up menu.3.

  SelectLUSEDetail from thepop-upmenu.The

LUSE

Detail

dialog

box

(Figure

7

on

page

29)

displays

a

list

of

volumes

(LDEVs)

combined

intotheLUSEvolume. Afterviewingthis list,clickClose toclose thedialogbox.

28 Performing LUSE Operations

Page 29: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 29/36

Figure 7 LUSE

Detail

Dialog

Box

•  LDKC:CU:LDEV : This fieldshowsanLDEVstatus icon. Thisfieldalsoshows theLDKC,CU,and

LDEV numbersof anLDEV.Note : An

LDEVnumber thatendswitha# indicates that theLDEV isanexternalvolume (forexample,00:00:01#). Fordetailsregardingexternalvolumes,seeHP StorageWorksXP24000 External Storage Software User’sGuide .Note:   AnLDEVnumberthatendswithaletter VindicatesthattheLDEVisavirtualvolume(V-VOL)

for

XP

Snapshot

(for

example,

00:00:01V ).

For

details

regarding

 V-VOLs,

see

HP 

StorageWorksXP24000 Snapshot User’sGuide .

Note : AnLDEVnumber thatendswitha letterX indicates that theLDEV isavirtualvolume

(V-VOL)for XP Thin Provisioning (for example, 00:00:01X).Fordetailsregarding V-VOLs,seeHP StorageWorksXP24000 ThinProvisioningSoftware User’sGuide .

• 

Capacity: Thisfield

shows

the

LDEV

capacity.

• 

RAID: Thisfield

shows

the

RAID

level

of

the

LDEV.

Note : The

RAID level is leftunspecifiedwithahyphen (-)when theLDEV isanexternalLU

orvirtual volume (V-VOL).

•  PG: This fieldshows theparitygroupnumber.Note : Aparitygroupnumberthatstartswitha letterEindicatesthattheparitygroupconsistsofoneormoreexternalLUs (forexample,E1-1).Note : A paritygroupnumber thatstartswitha letter V indicates that theparitygroupconsists

of

one

or

more

virtual

volumes

(V-VOLs)

(for

example,

 V1-1).•

 

CLPR: Thisfield

shows

the

CLPR

number.

For

detailed

information

about

CLPRs

(cache

logical

partitions),seeHP StorageWorksXP24000 Disk/Cache PartitionUser'sGuide .

•  Closebutton: Thisbuttoncloses theLUSEDetaildialogbox.

XP24000 LUNExpansionUser'sGuide

29

Page 30: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 30/36

30 Performing LUSEOperations

Page 31: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 31/36

5

Troubleshooting

Troubleshooting

LUN

Expansion

• 

For

troubleshooting

information

for

the

storage

system,

see

the

HP 

StorageWorks

XP24000 

Disk 

 Array 

Owner's

Guide .

•  FortroubleshootinginformationfortheRemote WebConsolesoftware,seetheHP StorageWorks

XP24000 Remote Web Console User’sGuide .

•  ForinformationabouttheRemote WebConsoleerrorcodes,seetheHP StorageWorksXP24000 Remote Web Console Error Codes.

CallingHPTechnical

Support

If

you

need

tocallHP technicalsupport,makesureyoucanprovideasmuch informationabout the

problemaspossible. Includethecircumstancessurroundingtheerrororfailure,theRemote WebConsole

configuration informationsaved in thefloppy diskettes by theFDDumpTool, the exact content of

messagesdisplayedontheRemote WebConsole,and theseveritylevelsandreferencecodesdisplayed

on

the

Status

tab

in

the

Remote

 Web

Console

Main

window

(see

the

HP 

StorageWorks

XP24000 

Remote Web  Console  Error  Codes).

Forworldwide technicalsupport information,see theHPsupportwebsite:

http://www.hp.com/support

XP24000 LUNExpansionUser'sGuide

31

Page 32: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 32/36

32 Troubleshooting

Page 33: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 33/36

 A Glossary,

 Acronyms,

and

 Abbreviations

Table

5

Glossary,

 Acronyms,

and

 Abbreviations

Cache

extents  Areasused forCacheResidencyManager

CU controlunit

Customaccess

 Afeaturethatallowsanon-administratortobeassignedupdateaccessto

one

or

more

of

the

restricted

Remote

Console

functions

DASD directaccessstoragedevice

DKCMAIN diskcontrollermain

ESCON

Enterprise

System

Connection

FD floppy disk

FDCopy floppy

disk

copy

CacheResidencyManager dynamiccache residency

GB gigabyte

KB kilobyte

LAN local-areanetwork

LBA logicalblockaddress

LDEV logicaldevice

LU logicalunit

LUN

logical

unit

number

LUN

Manager Remote

Console software option

LUSE LogicalUnitSizeExpansion

LVI logicalvolume image(alsocalleddeviceemulation)

MB megabyte

MIB message informationblock

Parity group

 Asetofharddiskdrives thathave thesamecapacityandaretreatedas

onegroup. Aparitygroupcontainsbothuserdataandparityinformation,

which

allows

the

user

data

to

be

accessed

in

the

event

that

one

or

more

of

the

drives

within

the

group

are

not

available.

RMCMAIN

remote

console

main

software

R-SIM remoteservice informationmessage.

SCSI smallcomputersystem interface

ShadowImage

HPMulti-RAIDCouplingFeatureand/orHPOpenMulti-RAIDCoupling

Feature.

SIM

service

information

message

(generated

by

a

disk

controller

when

it

detectsanerrororservicerequirement)

XP24000 LUNExpansionUser'sGuide

33

Page 34: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 34/36

SSID storagesubsystem ID

SVP

service processor

TCP/IP transmissioncontrolprotocol/internetprotocol

TID

target

ID

Trap

 AnSNMPagent initiates trapoperationswhenR-SIMsoccur inordertosend theR-SIMs to theSNMPmanager.  AnSNMPagentcanbe

configured todeliver

traps

to

more

than

one

SNMP

manager.

UCB

unit

control

block

 Volser volumeserialnumber (mainframevolume identifier,notrelated to the

LDEV ID)

 VMA volumemanagement

area

 WorldwideName,whichisauniqueidentifierforaparticularopen-system

 WWN host,consistingofa64-bitphysicaladdress(the IEEE48-bitformatwith

12-bitextensionand4-bitprefix)

34 Glossary, Acronyms,and Abbreviations

Page 35: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 35/36

Index 

 A

audience, 7

B

Before launchingLUNExpansion, 15

C

conventionsdocument, 8

storagecapacityvalues, 8

Create

LUSE volume, 19

CreateaLUSE Volume

methods, 22

D

documentconventions, 8

relateddocumentation, 7

documentation

HPwebsite, 7

providing feedback, 9

E

EnableLUNExpansion, 15

ExpandedLDEVs

create, 25

G

GUI, 17

H

help

obtaining, 8

HP

technicalsupport, 8

LLDEV, 11

LDEVDetailTable

create, 22

overview, 17

LDEVstatus icons, 18

logical

volume, 11

LUN Expansion, 11

LUN

Expansion

GUI, 17

LUSE, 11

function, 11

guidelines, 12

LUSE OperationsReleasingaLUSEvolume, 27

LUSE operationsChangingLUSEcapacities, 28

CreatingaLUSE Volume, 22

CreatingaLUSEvolume, 22

ReleasingaLUSEvolume, 27

LUSE window, 17

O

Overview

LUSE operations, 11

P

Preparing

to

use

LUSE, 15

R

related

documentation, 7

Releasingavolume

LUSE, 27

S

storagecapacityvalues

conventions, 8

storagesystems

supported

models, 7

Subscriber'sChoice,HP, 9

SystemRequirements, 15

T

technicalsupportHP, 8

service locatorwebsite, 9

Troubleshooting, 31

 V

 Volume Countdefinition, 19

XP24000 LUNExpansionUser'sGuide

35

Page 36: Luse Volume

8/17/2019 Luse Volume

http://slidepdf.com/reader/full/luse-volume 36/36

 W

websites

HP, 9

HPSubscriber'sChoiceforBusiness, 9

productmanuals, 7