LTE LTE-AIO-020 / Luminaire Data Sheet · Project 1 01.06.2016 Operator Telephone Fax e-Mail LTE...
Transcript of LTE LTE-AIO-020 / Luminaire Data Sheet · Project 1 01.06.2016 Operator Telephone Fax e-Mail LTE...
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
LTE LTE-AIO-020 / Luminaire Data Sheet
See our luminaire catalog for an image of the luminaire.
Luminous emittance 1:
Luminaire classification according to CIE: 100CIE flux code: 37 72 96 100 100
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
Page 1
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Planning data
Street Profile
Maintenance factor: 0.67
Roadway 1 (Width: 10.000 m, Number of lanes: 2, tarmac: R3, q0: 0.070)
Luminaire Arrangements
Luminaire: LTE LTE-AIO-020Luminous flux (Luminaire): 2281 lm Maximum luminous intensities
at 70°: 539 cd/klmat 80°: 340 cd/klmat 90°: 73 cd/klmAny direction forming the specified angle from the downward vertical, with
the luminaire installed for use.
Arrangement complies with glare index class D.6.
Luminous flux (Lamps): 2281 lmLuminaire Wattage: 20.4 WArrangement: Double row, with offsetPole Distance: 20.000 mMounting Height (1): 6.000 mHeight: 5.868 mOverhang (2): 0.000 mBoom Angle (3): 20.0 °Boom Length (4): 0.000 m
Page 2
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Luminaire parts list
LTE LTE-AIO-020Article No.: Luminous flux (Luminaire): 2281 lmLuminous flux (Lamps): 2281 lmLuminaire Wattage: 20.4 WLuminaire classification according to CIE: 100CIE flux code: 37 72 96 100 100Fitting: 1 x LTE-AIO-020 (Correction Factor 1.000).
See our luminaire catalog for an image of
the luminaire.
Page 3
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Photometric Results
Maintenance factor: 0.67 Scale 1:186
Calculation Field List
1 Valuation Field Roadway 1
Length: 20.000 m, Width: 10.000 mGrid: 10 x 6 PointsAccompanying Street Elements: Roadway 1. tarmac: R3, q0: 0.070Selected Lighting Class: ME4a (Not all lighting performance requirements are met.)
Lav [cd/m²] U0 Ul TI [%] SR
Calculated values: 0.58 0.70 0.60 9 0.53Required values according to class: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15 ≥ 0.50
Fulfilled/Not fulfilled:
Page 4
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / 3D Rendering
Page 5
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / False Colour Rendering
Page 6
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Isolines (E)
Values in Lux, Scale 1 : 186
Grid: 10 x 6 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
9.06 7.85 12 0.867 0.653
Page 7
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Greyscale (E)
Scale 1 : 186
Grid: 10 x 6 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
9.06 7.85 12 0.867 0.653
Page 8
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Value Chart (E)
Values in Lux, Scale 1 : 186
Grid: 10 x 6 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
9.06 7.85 12 0.867 0.653
Page 9
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Table (E)
9.167 12 9.34 7.87 7.89 8.26 8.39 8.33 8.16 9.45 12
7.500 11 9.18 7.93 7.97 8.81 8.94 8.46 8.27 9.27 11
5.833 9.98 8.62 7.85 8.13 9.20 9.40 8.54 8.17 8.78 10
4.167 9.20 8.13 7.85 8.62 9.98 10 8.78 8.17 8.54 9.40
2.500 8.81 7.97 7.93 9.18 11 11 9.27 8.27 8.46 8.94
0.833 8.26 7.89 7.87 9.34 12 12 9.45 8.16 8.33 8.39
m 1.000 3.000 5.000 7.000 9.000 11.000 13.000 15.000 17.000 19.000Attention: The coordinates refer to the image above. Values in Lux.
Grid: 10 x 6 Points
Eav
[lx] Emin
[lx] Emax
[lx] u0 Emin
/ Emax
9.06 7.85 12 0.867 0.653
Page 10
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 1 / Isolines (L)
Values in Candela/m², Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 2.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.71 0.61 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 11
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 1 / Greyscale (L)
Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 2.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.71 0.61 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 12
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 1 / Value Chart (L)
Values in Candela/m², Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 2.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav
[cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.71 0.61 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 13
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 2 / Isolines (L)
Values in Candela/m², Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 7.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.70 0.60 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 14
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 2 / Greyscale (L)
Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 7.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav [cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.70 0.60 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 15
Project 1
01.06.2016
OperatorTelephone
Faxe-Mail
Street 1 / Valuation Field Roadway 1 / Observer 2 / Value Chart (L)
Values in Candela/m², Scale 1 : 186
Grid: 10 x 6 Points Observer Position: (-60.000 m, 7.500 m, 1.500 m) tarmac: R3, q0: 0.070
Lav
[cd/m²] U0 Ul TI [%]
Calculated values: 0.58 0.70 0.60 9
Required values according to class ME4a: ≥ 0.75 ≥ 0.40 ≥ 0.60 ≤ 15
Fulfilled/Not fulfilled:
Page 16