Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5...

15
Page 104 MBS AG Eisbachstraße 51 - 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90 E-Mail: [email protected] - Web: www.mbs-ag.com MBS AG Low-voltage current transformers for industrial applications Split-core current transformer for isolated primary conductors KBR 18S Round conductor: 18,5 mm Transformer width: 36 mm Current range: 60 ... 250 A Page: 105 KBR 18 Round conductor: 18,5 mm Transformer width: 41,6 mm Current range: 50 ... 250 A Page: 106 KBR 18L Round conductor: 18,4 mm Transformer width: 49 mm Current range: 100 ... 250 A Page: 107 KBR 28 Round conductor: 27,9 mm Transformer width: 49 mm Current range: 200 ... 500 A Page: 108 KBR 32 Round conductor: 32,5 mm Transformer width: 59,2 mm Current range: 100 ... 600 A Page: 109 KBR 42 Round conductor: 42,4 mm Transformer width: 67 mm Current range: 250 ... 1000 A Page: 110 KBR 42L Round conductor: 2x 42,4 mm Transformer width: 67 mm Current range: 250 ... 1000 A Page: 111 KBR 44 Round conductor: 44 mm Transformer width: 72,2 mm Current range: 250 ... 1000 A Page: 112

Transcript of Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5...

Page 1: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 104

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Low-voltage current transformersfor industrial applications

Split-core current transformer for isolated primary conductors

KBR 18S Round conductor: 18,5 mmTransformer width: 36 mm

Current range: 60 ... 250 A Page: 105

KBR 18 Round conductor: 18,5 mmTransformer width: 41,6 mm

Current range: 50 ... 250 A Page: 106

KBR 18L Round conductor: 18,4 mmTransformer width: 49 mm

Current range: 100 ... 250 A Page: 107

KBR 28 Round conductor: 27,9 mmTransformer width: 49 mm

Current range: 200 ... 500 A Page: 108

KBR 32 Round conductor: 32,5 mmTransformer width: 59,2 mm

Current range: 100 ... 600 A Page: 109

KBR 42 Round conductor: 42,4 mmTransformer width: 67 mm

Current range: 250 ... 1000 A Page: 110

KBR 42L Round conductor: 2x 42,4 mmTransformer width: 67 mm

Current range: 250 ... 1000 A Page: 111

KBR 44 Round conductor: 44 mmTransformer width: 72,2 mm

Current range: 250 ... 1000 A Page: 112

Page 2: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 105

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Round conductor 18,5 mm Transformer width 36,0 mm Height 62,4 mm Depth 50 mm

KBR 18 S Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

1 A Cl. 3

Art.-no.

1 A Cl. 1

Art.-no. 60 0,4 18S-0001 75 0,5 18S-0002 100 0,75 18S-0003 125 0,75 18S-0004 150 1 18S-0005

200 0,4 18S-00061,5 18S-0007

250 0,5 18S-00082 18S-0009

Art.-no.

Snap-on mounting, type H 55016

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 18S has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The delivery follows with 2.5 m connection cable 2 x 0.5 mm² (color coded; S1 =

brown; S2 = blue), other lengths of the connection cables are possible on request.• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 3: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 106

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

5567,30

41,6max. 18,50

64,5

023

Round conductor 18,5 mm Transformer width 41,6 mm Height 64,5 mm Depth 68 mm

KBR 18 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

1 A Cl. 3

Art.-no.

1 A Cl. 1

Art.-no. 50 1 18-0001 75 1 18-0006 100 1,25 18-0011 125 1,5 18-0016 150 2 18-0021

200 1 18-0027 3 18-0026

250 1,5 18-0032 4 18-0031

Optional mit Spannungsausgang:

Primary current [A]

Spannungsausgang [mV]

Class1

50 0...333 18-1001 75 0...333 18-1006 100 0...333 18-1011 125 0...333 18-1016 150 0...333 18-1021 200 0...333 18-1026 250 0...333 18-1031

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 18 has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The delivery follows with 2.5 m connection cable 2 x 0.75 mm² (color coded;S1 =

brown; S2 = blue), other lengths of the connection cables are possible on request.• For the use as a current sensor the KBR 18 is optionally deliverable with a voltage

output of 0 – 333 mV (Min. burden resistance ≥ 1 kΩ).• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 4: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 107

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Round conductor 18,4 mm Transformer width 49,0 mm Height 80,1 mm Depth 59 mm

KBR 18 L Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 100 0,3 18L-0001125 0,5 18L-0002150 1 18L-5001 18L-0003

200 0,2 18L-00041,5 18L-5002 18L-0005

250

0,5 18L-00061 18L-50032 18L-5004

2,5 18L-0007

Art.-no.

Snap-on mounting, type I 55017

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 18L has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 18L with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.5 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2 x 1.5 mm².• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 5: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 108

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Round conductor 27,9 mm Transformer width 49,0 mm Height 79,5 mm Depth 59 mm

KBR 28 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 200 0,3 28-0001250 1 28-5001 28-0002300 1,5 28-5002 28-0003

400 0,5 28-00042,5 28-5003 28-0005

5001 28-5004 28-00063 28-5005 28-0007

Art.-no.

Snap-on mounting, type I 55017

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 28 has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 28 with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.5 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2x1.5 mm².• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 6: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 109

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

max.32,50

59,2

96,4

7589,20

Round conductor 32,5 mm Transformer width 59,2 mm Height 96,4 mm Depth 90 mm

KBR 32 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 3

Art.-no.

5 A Cl. 1

Art.-no.

1 A Cl. 3

Art.-no.

1 A Cl. 1

Art.-no.

100 1,5 32-5011 2,5 32-0011

125 2,5 32-5016 3 32-0016

150 3 32-5021 32-0021

200 3 32-5026 5 32-0026

250 3 32-5031 5 32-0031

300 2,5 32-5035 5 32-0035

400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041

Primary current [A]

Output signal Cl. 1 Art.-no.[mV] AV [mA] DC

100 0...333 – 32-1011

– 4...20 32-2011

125 0...333 – 32-1016

– 4...20 32-2016

150 0...333 – 32-1021

– 4...20 32-2021

200 0...333 – 32-1026

– 4...20 32-2026

250 0...333 – 32-1031

– 4...20 32-2031

300 0...333 – 32-1034

– 4...20 32-2034

400 0...333 – 32-1036

– 4...20 32-2036

500 0...333 – 32-1038

– 4...20 32-2038

600 0...333 – 32-1040

– 4...20 32-2040

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 32 has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 32 with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.75 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2 x 1.5 mm².• For the use as a current sensor the KBR 32 is optionally deliverable with a voltage

output of 0 – 333 mV (min. burden resistance ≥ 1 kΩ). Moreover the KBR 32 is deliverable as a measuring transducer with a measuring output of 4…20 mA DC, connection scheme see page 113.• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 7: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 110

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Round conductor 42,4 mm Transformer width 67,0 mm Height 96,0 mm Depth 69 mm

KBR 42 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 250 2,5 42-0001300 2,5 42-5001 42-0002

4002,5 42-00035 42-5002 42-0004

5002,5 42-00055 42-5003 42-0006

6002,5 42-5004 42-00075 42-5005 42-0008

7502,5 42-5006 42-00095 42-5007 42-0010

8002,5 42-5008 42-00115 42-5009 42-0012

10002,5 42-5010 42-00135 42-5011 42-0014

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 42 has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 42 with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.5 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2 x 1.5 mm².• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 8: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 111

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Round conductor 2x 42,4 mm Transformer width 67,0 mm Height 139,0 mm Depth 69 mm

KBR 42L Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 250 2,5 42L-0001300 2,5 42L-5001 42L-0002

4002,5 42L-00035 42L-5002 42L-0004

5002,5 42L-00055 42L-5003 42L-0006

6002,5 42L-5004 42L-00075 42L-5005 42L-0008

7502,5 42L-5006 42L-00095 42L-5007 42L-0010

8002,5 42L-5008 42L-00115 42L-5009 42L-0012

10002,5 42L-5010 42L-00135 42L-5011 42L-0014

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 42L has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 42L with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.5 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2 x 1.5 mm².• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 9: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 112

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

max.44

120,

6

72,2

8598,10

Round conductor 44 mm Transformer width 72,2 mm Height 120,6 mm Depth 98 mm

KBR 44 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

1 A Cl. 1

Art.-no.

250 1,5 44-5001 2,5 44-0001

300 2,5 44-5006 44-0006 400 5 44-5011 44-0011 500 5 44-5016 44-0016 600 5 44-5021 44-0021 750 5 44-5026 44-0026 800 5 44-5031 44-0031

1000 5 44-5036 44-0036

Primary current [A]

Output signal Cl. 1Art.-no. [mV] AV [mA] DC

250 0...333 – 44-1001

– 4...20 44-2001

300 0...333 – 44-1006

– 4...20 44-2006

400 0...333 – 44-1011

– 4...20 44-2011

500 0...333 – 44-1016

– 4...20 44-2016

600 0...333 – 44-1021

– 4...20 44-2021

750 0...333 – 44-1026

– 4...20 44-2026

800 0...333 – 44-1031

– 4...20 44-2031

1000 0...333 – 44-1036

– 4...20 44-2036

• Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor.• The compact split-core current transformer KBR 44 has been developed to have easy

access in already existing installations.• Due to the „click“-system and the fixing-clasps even a one-hand mounting is possible.• The KBR 44 with secondary 1A will be delivered with 2.5 m connection cable 2 x 0.75 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection

cables are possible on request. The secondary 5A – version will be delivered with 0.5m connection cable 2 x 1.5 mm².• For the use as a current sensor the KBR 32 is optionally deliverable with a voltage

output of 0 – 333 mV (min. burden resistance ≥ 1 kΩ). Moreover the KBR 32 is deliverable as a measuring transducer with a measuring output of 4…20 mA DC.• Operating temperature: -5°C < T < +50°C• Storage temperature: -25°C < T < +70°C

Page 10: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 113

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

KBR

k-s1I-s2

24V DC– +

A

KBR 32 / 44 Technical characteristics for the KBR 32 / 44 with output signal 4…20 mA:

Wiring diagram of the KBR 32 / 44 (4…20 mA):

• 2-wire connection, auxiliary power via output circuit• Auxiliary power: 24 V DC ± 15 %, PV = max. 1 VA• Load-independent DC current: Live-zero, 4…20 mA• External resistance: max. 300 Ω• Current limit under overload: < 30 mA• Residual ripple of the output current: ≤ 1 % p.p.• Response time: < 300 ms

Page 11: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 114

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

Low-voltage current transformersfor industrial applications

Split-core current transformer

KBU 23 Bus bar 1: 20 x 30 mmRound conductor: 20 mmTransformer width: 93 mm

Current range: 100 ... 400 A Page: 115

KBU 58 Bus bar 1: 50 x 80 mmRound conductor: 50 mmTransformer width: 125 mm

Current range: 250 ... 1000 A Page: 116

KBU 812 Bus bar 1: 80 x 120 mmRound conductor: 80 mmTransformer width: 155 mm

Current range: 250 ... 1500 A Page: 117

KBU 816 Bus bar 1: 80 x 160 mmRound conductor: 80 mmTransformer width: 195 mm

Current range: 1000 ... 5000 A Page: 118

Page 12: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 115

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

23

93

3336

,15

106,

15

3458

71

6,50

64

56

Bus bar 1 20 x 30 mm Round conductor 20 mm Transformer width 93 mm Height 106 mm Depth 58 mm

KBU 23 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 3

Art.-no.

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no. 100 1,25 80048 150 1,5 80030 200 2,5 80031 250 1,5 80044 300 3,75 80045

400 1 80037 5 80046

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

1 A Cl. 3

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 100 1,25 80248 150 1,5 80230 200 2,5 80231 250 1,5 80244 300 3,75 80245

400 1 80237 5 80246

Page 13: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 116

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

85

158,

15

125

36,1

5

55

3458

71

56

96

6,50

Bus bar 1 50 x 80 mm Round conductor 50 mm Transformer width 125 mm Height 158 mm Depth 58 mm

KBU 58 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 250 1,5 80061 80261 300 2,5 80062 80262

400 1 80038 80238

2,5 80063 80263

500 2,5 80054 80254 5 80064 80264

600 2,5 80055 80255 5 80065 80265

750 2,5 80056 80256 5 80066 80266

800 2,5 80057 80257 7,5 80067 80267

1000 5 80058 80258

10 80068 80268

Page 14: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 117

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

85155

125

36,1

519

8,15

5834

71

56

126

6,50

Bus bar 1 80 x 120 mm Round conductor 80 mm Transformer width 155 mm Height 198 mm Depth 58 mm

KBU 812 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no. 250 1,5 80091 80291 300 2,5 80092 80292 400 2,5 80093 80293

500 2,5 80074 80274 5 80094 80294

600 2,5 80075 80275 5 80095 80295

750 2,5 80076 80276 5 80096 80296

800 2,5 80077 80277 7,5 80097 80297

1000 5 80078 80278

10 80098 80298

1200 5 80079 80279

10 80099 80299

1250 7,5 80080 80280 15 80100 80300

1500 7,5 80081 80281 15 80101 80301

Page 15: Low-voltage current transformers for industrial … split core.pdf3 32-5031 5 32-0031 300 2,5 32-5035 5 32-0035 400 5 32-5037 32-0037 500 5 32-5039 32-0039 600 5 32-5041 32-0041 imar

Page 118

MBS AGEisbachstraße 51 - 74429 Sulzbach-Laufen

Germany

Telefon: +49 7976 9851-0 - Telefax: +49 7976 9851-90E-Mail: [email protected] - Web: www.mbs-ag.com

MBS AG

85

195

165

243

37

64

79

62

156

6,50

Bus bar 1 80 x 160 mm Round conductor 80 mm Transformer width 195 mm Height 243 mm Depth 79 mm

KBU 816 Split-core current transformer

Secondary current [A] / Class

Primary current

[A] Burden

[VA]

5 A Cl. 1

Art.-no.

5 A Cl. 0,5

Art.-no.

1 A Cl. 1

Art.-no.

1 A Cl. 0,5

Art.-no.

1000 10 80140 80110 80340 80310 15 80141 80341

1200 10 80142 80111 80342 80311 15 80143 80343

1500 10 80144 80112 80344 80312 15 80145 80113 80345 80313

1600 10 80146 80114 80346 80314 15 80147 80115 80347 80315

2000 10 80148 80116 80348 80316 15 80149 80117 80349 80317

2500 10 80150 80119 80350 80319 15 80151 80120 80351 80320

3000 15 80152 80122 80352 80322 30 80153 80353

4000 15 80154 80123 80354 80323 30 80155 80124 80355 80324

5000 15 80156 80125 80356 80325 30 80157 80126 80357 80326