Low p T Muon trigger studies for J/ Supreet Pal Singh (Panjab University, Chandigarh) Prof....

17
Low p T Muon trigger studies for J/ Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof. Kajari Mazumdar (TIFR, Mumbai) 1 India-CMS Meeting 29th-30th July 2010

Transcript of Low p T Muon trigger studies for J/ Supreet Pal Singh (Panjab University, Chandigarh) Prof....

Page 1: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Low pT Muon trigger studies for J/

Supreet Pal Singh (Panjab University, Chandigarh)

Prof. J.B.Singh (Panjab University, Chandigarh)

Prof. Kajari Mazumdar (TIFR, Mumbai)

1India-CMS Meeting 29th-30th July 2010

Page 2: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

MotivationStudy of quarkonium production at high energy collision is always

interesting testing ground of non-relativistic QCD including the technique of factorisation:

production of heavy quark-antiquark pair calculated in perturbative method.

non-perturbative effects which bind the heavy quark pair into a quarkonium various models try to describe this, eg. , colour singlet, colour octet, etc.

Final state polarisation depends on the model as well as the transverse momentum of the produced J/ψ .

Experimental data till now is unable to resolve various issues at LHC physics of J/ψ will be pursued hot through differential cross-section

d (J/ψ)/ dPT, polarisation measurements, etc.

2India-CMS Meeting 29th-30th July 2010

Page 3: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

New Trigger paths at HLT proposed

At LHC startup the actual instantaneous luminosity is lower than anticipated low pT physics can be studied using softer triggers than planned earlier. At high instantaneous lumi, low

threshold triggers will have to be prescaled.

J event statistics should be high enough to be competitive with other experiments at the early stage of CMS.

Need as low PT Jevent sample as possible produced in mid-rapidity regions atleast.

• In 70% of J dimuons that CMS can reconstruct in minimum bias events, one of the muon can be only a tracker muon, and NOT a global muon

• Thus GT and TT samples are crucial to cover low pT range , especially for | ~ 1 - 2.5India-CMS Meeting 29th-30th July 2010

Page 4: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Way out in CMS: devise a double muon trigger at HLT to catch low pt tracks from J/ ψ Start with standard L1 info

L1 firmware remains unchanged

Combine Global Muon + track of J/ψ trigger rate < 10 Hz, tolerable.

Distribution of J/ψ dimuons in phase space.

Page 5: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

• HLT_MuX_Track0_Jpsi A new trigger configuration where a single L3 muon is combined to tracker track within invariant mass window of 2.8-3.4 GeV/c2 . Different trigger configurations possible with transverse momentum cut on L3 muon.

HLT_Mu0_Track0_Jpsi : L3 Muon pT > 0 GeV/c,

HLT_Mu1p5_Track0_Jpsi : L3 Muon pT > 1.5 GeV/c,

HLT_Mu2_Track0_Jpsi : L3 Muon pT > 2 GeV/c,

HLT_Mu3_Track0_Jpsi : L3 Muon pT > 3 GeV/c,

HLT_Mu5_Track0_Jpsi : L3 Muon pT > 5 GeV/c,

This lowers the trigger rate and the signal statistics are not reduced much.

Exercise for detremining gain of new path, evaluating trigger rates etc. during April, May, June of this year , strategy validated, trigger in placeMore work in progress.

Page 6: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

pT distributions for different trigger Configurations

Dimuon combinations: GG global-global muons (black) GT global-tracker muons (red) ; TT tracker-tracker muons (blue)

Global muons Reconstruction starts from muon stations and matched to a track in tracker.Tracker muons Reconstruction starts in tracker and matched to a tracklet in muon station.

6India-CMS Meeting 29th-30th July 2010

Page 7: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Muon trigger rate will change with evolving luminosityMaximum trigger rate should be about 25 Hz with change in trigger path once a month, almost.

Page 8: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Efficiencies and trigger rates for different trigger configurations of “HLT_MuX_Track0_Jpsi”

pTmin [GeV/c]

of L3 Muon

Trigger Rate [Hz]

0.0 6.11.5 5.82.0 4.33.0 1.75.0 0.4

Going from Mu0 to Mu3 the trigger rates drops very strongly (good) but the signal efficiency also suffers.

We could set the muon pT threshold at 2.0 Gev/c instead of 3.0 GeV/c, to keep a good low pT coverage for a longer period.

8India-CMS Meeting 29th-30th July 2010

Page 9: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Effect of changing the pT cut on pixel and tracker track (matched to L3 muon) in HLT_Mu0_Track0_Jpsi.

Presently pT cut on pixel and tracker track 3.0 GeV

To improve the signal efficiency new cuts on pixel and tracker track pTpixel > 2.2 GeV/c pTtracker > 2.5 GeV/c

9India-CMS Meeting 29th-30th July 2010

Page 10: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Efficiencies for different configurations of HLT for various pT cuts

increase in the efficiency

10India-CMS Meeting 29th-30th July 2010

Before

After

Page 11: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

pT & rapidity distributions and the corresponding Efficiencies for various HLT triggers for CMS Data run numbers (certified) 132440-135445

“Reference” trigger: HLT_L1MuOpen, Efficiencies of other trigger paths are calculated relative to the same for events passing the HLT_L1MuOpen trigger

11India-CMS Meeting 29th-30th July 2010

Page 12: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Mass distributions and the corresponding efficiencies CMS Data run numbers (certified) 132440-135445

HLT_L1MuOpen is prescaled after run rumber 135445 cannot be taken as a “default” trigger .

HLT_Mu3 is good only for pT > 3 GeV.

HLT_L1DoubleMuOpen is very efficient can be taken as reference to study HLT_Mu0_Track0_Jpsi till it is prescaled.

12India-CMS Meeting 29th-30th July 2010

Page 13: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

pT & rapidity distributions and the corresponding Efficiencies for HLT_Mu0_Track0_Jpsi for CMS Data run numbers (certified) 135521-140076

13India-CMS Meeting 29th-30th July 2010

Page 14: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

2D efficiency plot of the HLT_Mu0_Track0_Jpsi trigger path w.r.t. HLT_L1DoubleMuOpen trigger

• HLT_Mu0_Track0_Jsi trigger is best suited for mid-rapidity region No requirement for 2nd muon in DT, while HLT_L1DoubleMuOpen require hits in at least “two” DT segments.

• HLT_L1DoubleMuOpen is efficient but effected by background, cannot be used as unprescaled for long.

• HLT_Mu0_Track0_Jpsi “Cleaner” trigger.

14India-CMS Meeting 29th-30th July 2010

Page 15: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Keep ψ(2S) in the game !

Increase HLT mass window from 2.7 -- 3.5 GeV to 2.7 – 3.9 GeV the rate incrases by a factor of 1.5

Work in porgress

Page 16: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.

Summary

New J triggers in CMS: looser muon triggers (eg. no pt threshold)• HLT_Mu0 + track in the J/ mass window

Good for all physics analyses with a J/ in the final state Also gives a handle to measure all muon related efficiencies.

• Trigger rate for the different trigger configurations of HLT_Mu0_Track0_Jpsi has to be monitored carefully.

• The efficiency can be increased further by changing the pT cut on the pixel and tracker track to 2.2 GeV/c and 2.5 GeV/c.

• Data has started coming and HLT_Mu0_Track0_Jpsi has been included in the official HLT trigger paths.

• Favorable for polarization studies of low pT dimuons from J/ more statistics can be accumulated.

• Good Time ahead for physics with J/ muons

16India-CMS Meeting 29th-30th July 2010

Page 17: Low p T Muon trigger studies for J/       Supreet Pal Singh (Panjab University, Chandigarh) Prof. J.B.Singh (Panjab University, Chandigarh) Prof.