LOT 7 BURLEIGH VIEW (A) UNIT 2 - Custom Land Group

7
CLIENT: GENERAL NOTES DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN PLANNING REQUIREMENTS, REPORT ANY DISCREPANCIES TO BLUEWATER BUILDING DESIGNS . ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF AUSTRALIAN AND THE AUSTRALIAN STANDARDS. AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE AS 2049 - 2002 ROOF TILES AS 2050 - 2002 INSTALLATION OF ROOF TILES AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION AS/NZS 2904 - 1995 DAMP - PROOF COURSES AND FLASHINGS AS 3600 - 2000 CONCRETE STRUCTURES AS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITES AS 3700 - 2001 MASONRY IN BUILDINGS AS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS AS 3786 - 1993 SMOKE ALARMS AS 4055 - 2006 WIND LOADINGS FOR HOUSING AS 4100 - 1998 STEEL STRUCTURES THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL ENGINEERING COMPUTIONS AND DRAWINGS. SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST. ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS. SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES - i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE iii) FULLY GLAZED DOORS iv) SHOWER SCREENS v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY WITH MANUFACTURER, FLASHING ALL ROUND. ALL GUTTERS TO BE QUAD GUTTERING WITH MIN. 100x75 RECTANGULAR OR 100 dia. DOWNPIPES, EACH DOWNPIPE SHALL SERVICE A MAXIMUM ROOF AREA OF 36sq.m OR SHALL BE POSITIONED AS PER AS 3500.3, 2003, SECTION 3. STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY. TILED DECKS OVER LIVABLE AREAS ARE TO BE IN THE FOLLOWING ORDER OVER THE FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF 1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750. FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR. ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED. ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BE IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE WALL. PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL. SUB - FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sq FOR INTERNAL WALLS BELOW BEARER. THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5 BATTS AND REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY RATING. STAIR REQUIREMENTS: MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm, SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE. BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND IN ACCORDANCE WITH BCA 3.9.2. FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE DEFLECTION) OF THE BCA. THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF EXISTING AND NEW STRUCTURES THROUGH - OUT CONSTRUCTION. SITE DETAILS: JOB No: ISSUE: BLUEWATER BUILDING DESIGNS BLUEWATER BUILDING DESIGNS BLUEWATER BUILDING DESIGNS BLUEWATER BUILDING DESIGNS AREA PROPERTY DETAILS S.P. NUMBER PARISH COUNTY LOT PHONE : 0410 648 059 ABN : 25 367 288 616 QBSA LIC. 1212800 EMAIL : [email protected] Bluewater Template | Version 20.1.2 LOT 7 SIREC WAY BURLEIGH HEADS A Sheet List Sheet Name Sheet Number Site Plan 100 Floor Plan - UNIT 2 300 Elevations - UNIT 2 301 Electrical Plan 400 Internal Elevations 500 Internal Elevations 501 UNIT 2 UNIT 2

Transcript of LOT 7 BURLEIGH VIEW (A) UNIT 2 - Custom Land Group

CLIENT:

GENERAL NOTES

DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.

THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS

AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING MATERIALS AND SHALL BE

RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BUILDING CODE OF

AUSTRALIA 2006, CURRENT AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN

PLANNING REQUIREMENTS, REPORT ANY DISCREPANCIES TO BLUEWATER BUILDING DESIGNS.

ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF AUSTRALIAN AND

THE AUSTRALIAN STANDARDS.

AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION

AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING

AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE

AS 2049 - 2002 ROOF TILES

AS 2050 - 2002 INSTALLATION OF ROOF TILES

AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION

AS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGS

AS 3600 - 2000 CONCRETE STRUCTURES

AS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITES

AS 3700 - 2001 MASONRY IN BUILDINGS

AS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS

AS 3786 - 1993 SMOKE ALARMS

AS 4055 - 2006 WIND LOADINGS FOR HOUSING

AS 4100 - 1998 STEEL STRUCTURES

THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL ENGINEERING

COMPUTIONS AND DRAWINGS.

SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.

ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE WITH AS

3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX INDICATING TYPE OF

BARRIER AND REQUIRED PERIODICAL INSPECTIONS.

SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -

i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR

ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE

iii) FULLY GLAZED DOORS

iv) SHOWER SCREENS

v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL

vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY

WITH MANUFACTURER, FLASHING ALL ROUND.

ALL GUTTERS TO BE QUAD GUTTERING WITH MIN. 100x75 RECTANGULAR OR 100 dia. DOWNPIPES,

EACH DOWNPIPE SHALL SERVICE A MAXIMUM ROOF AREA OF 36sq.m OR SHALL BE POSITIONED

AS PER AS 3500.3, 2003, SECTION 3. STORMWATER TO BE TAKEN TO THE LEGAL POINT OF

DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.

TILED DECKS OVER LIVABLE AREAS ARE TO BE IN THE FOLLOWING ORDER OVER THE FLOOR

JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF PARCHEM EMERPROOF

750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF 1300 MICRON, INSTALLED TO MANUF.

SPECIFICATIONS, AND FLOOR TILES OVER, ALL CORNERS TO HAVE 20mm MASTIC SEALANT

UNDER THE PARCHEM EMERPROOF 750.

FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS RECOMMENDED THAT

WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BUNDARIES, A CHECK SURVEY

BE CONDUCTED BY A LICENSED SURVEYOR.

ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.

ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BE

IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE

WALL.

PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND WITHIN 300mm

OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.

SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sq FOR

INTERNAL WALLS BELOW BEARER. THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5

BATTS AND REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY RATING.

STAIR REQUIREMENTS: MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm, SPACE

BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE. BALUSTRADES : MIN.

1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND IN ACCORDANCE WITH BCA 3.9.2.

FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE

CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE DEFLECTION) OF THE

BCA.

THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF EXISTING AND

NEW STRUCTURES THROUGH-OUT CONSTRUCTION.

SITE DETAILS:

JOB No: ISSUE:

BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

AREA

PROPERTY DETAILS

S.P. NUMBER

PARISH

COUNTY

LOT

PHONE: 0410 648 059ABN: 25 367 288 616

QBSA LIC. 1212800

EMAIL: [email protected]

Bluewater Template | Version 20.1.2

LOT 7 SIREC WAY BURLEIGH HEADS

A

Sheet List

Sheet NameSheetNumber

Site Plan 100

Floor Plan - UNIT 2 300

Elevations - UNIT 2 301

Electrical Plan 400

Internal Elevations 500

Internal Elevations 501

UNIT 2

UNIT 2

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Site Plan

2.4.20

100 A

PRELIMINARY2.4.20

EAST

WEST

SUMMERBREEZES

PMN

E-

SE

WINTERSUNAM

SUMMERSUN

AM

SU

MM

ER

BR

EE

ZES

AM

S-

SE

SUMMER STORMS

WINTER WINDS W- SWSUMMER

SUN

PM W

INT

ER

SU

NP

M

SOUTH

TRUE NORTH

M.G

.A.

LOT AREA =

HOUSE FOOTPRINT =

SITE COVERAGE = 50%

500m²

1000m²

GL = 00.00

CUT = <000mm

FILL = <000mm

FL = REFER TO ENGINEERS

1. EARTHWORKSa) Cut and fill indicated on plan may vary at construction stage and builder is to verify and adjust as required.b) Any variation at construction stageis to comply with Council policy on earthworks/drainage for residential sites.c) Site works indicated on this plan are for construction purposes only.2. RETAINING WALLSa) All retaining walls are to comply with Council policy on retaining walls and embankments on residential building sites.b) Position of retaining wall may vary and must be verified by builder prior to commencement.c) Any variation at construction stage to comply with Council policy.3. CONTOURS AND LEVELSa) Contours and levels shown on plan are taken from levels supplied by contour surveyor and no responsibility is taken for accuracy or cut and fill levels.

NOTE:STORMWATER DRAINAGE CALCULATED FOR BUILDING ROOF AREAS AND/OR PAVED AREAS SHOWN ON THIS PROPOSED DEVELOPMENT ONLY AND MAY NOT BE ADEQUATE FOR ANY SUBSEQUENT ROOF OR PAVED AREAS.

MIN 100x75 DOWNPIPES ( EACH TO DRAIN MAX 40.00m sq. ROOF AREA) DISCHARING INTO 100mm sq. S/W DRAINAGE PIPEWORK (EACH RUN CARRYING MAX CAPACITY OF 8 litres/sec) MIN GRADE TO RUBBLE PITS ON SITE TO BE 1%

NOTE:

ALL FENCING, RETAINING WALLS,

LANDSCAPING & COVENANT

APPROVAL BY OWNER.

REFER TO BUILDERS SPECIFICATION

FOR DETAILS

BAL 12.5 BUSH FIRE REQUIREMENTS

• VENTS AND WEEPHOLES TO BE SCREENED WITH MESH AT A 2mm APERTURE

• FLYSCREENS TO BE METAL WITH A 2mm APERTURE

• WINDOW GLAZING LESS THAN 400mm FROM GROUND TO HAVE 4mm SAFETY GLASS

• EXTERNAL TIMBER DOORS TO BE SOLID CORE OF 35mm min. THICKNESS. GLAZING IN DOORS TO BE 4mm SAFETY GLASS. WEATHER STRIPS TO BE FITTED TO THE BOTTOM OF DOOR

• PANEL LIFT GARAGE DOORS TO BE FITTED WITH WEATHER STRIPS

• ALL ROOF TYPES TO BE SEALED TO PREVENT OPENING S OF 3mm. ALL ROOF OPENINGS TO HAVE EMBER GUARDS

• TILED AND COLORBOND ROOFS TO BE FULLY SARKED

• EAVE VENTS TO HAVE EMBER GUARDS WITH A 2mm APERTURE

NOTE:

NATURAL GAS SUPPLY TO BE CONNECTED

TO THE HOUSE IF AVAILABLE

TO BE CONFIRMED

REFER TO UNIT 1 PLANS FOR SITE PLAN

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Tap

Tap

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

FDFD

S

S

S

S

S

S

10

20

LIVING

DINING

KITCHEN

ENTRY

PORCH

GARAGE

L'DRY

WCP'TRY

ALFRESCO

F

720

820

82

0

82

0

720

SHELVES

2448 AUTO PANEL LIFT

820

70580070

7024807040907098070145070139070113070162070

703400429070144070260070162070

13700

70142070580070

255052105940

69070

73070

5720

2400

70 703890

704000

1030

9750

702150

705900

70530

70705900

7053070

1090

70990

70

705900

702750

70

8860

LINEN LINEN

1200

0906 SF 0624 F

690

1300

OH

C

SERVICES

21

15

SD

3000

2124 SD

2106 DH-FB2106 DH-FB

2106 DH-FB 2106 DH-FB

980 70 4090 70 2480 70

720 3000 70 2480 70

13700

BEAM

BE

AM

720

140sq. HWD

TIMBER

POSTS

21

24

SD

5.9

0 m

5.80 m

3.8

9 m3.40 m

890

820

WM

D

ryr.

DP

DP

DP DP

DP

DP

DP

90mm STEP

90mm STEP

702150

3930

701970

70

108.42m2

Ground Floor

14.80m2

Alfresco

2.62m2

Porch

MASTER BEDROOM

WIR

ENS

BED 2

BED 3

STUDY

BED 4BATH

WC

82

0

72

0

720

ROBE

BATH1520

RETREAT

LINEN

1600

0906 SF0912 SF0450 x 0900 SF

1518 F1506 DH1518 F 1506 DH

1518 F1506 DH

4.00 m

4.0

0 m

1000m

m wall

1000m

m wall

ROBE

12

18

SF

1218 SF

770

820

820

82

0

1800

21

00

09

24

FS

SF

3.0

0 m

3.25 m

2.9

3 m

3.00 m

2.2

5 m

4.07 m

3.0

0 m

3.47 m

70 3000 70 1690 70 970 70 1000 70 4070 70

70 3000 70 1690 70 2040 70530

70 3470 70

11150

70900

701000

3500

701000

703000

70

890

702110

701820

701100

7053070

2880

70

890

704000

1080

701700

701800

70

890

8860

70 3000 1000 70 1730 70 1000 70 4070 70

70 4000 70550

70 3250 70 3000 70

703000

701000

704500

70900

70

703000

703470

70950

701980

70 703000

702250

70530

702930

70690

9750

4690 3390 3070

11150

18

00

DP

DP

DPDP

DP

DP

98.36m2

First Floor

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

As indicated

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Floor Plan - UNIT 2

2.4.20

300 A

PRELIMINARY2.4.20

Elevation 3

Elevation 4

Elevation 1

Elevation 2

1 : 100

Floor Plan - Ground Floor

Area ScheduleName Area Perimeter

Alfresco 14.80 m² 15.20 m

First Floor 98.36 m² 41.80 m

Ground Floor 108.42 m² 46.66 m

Porch 2.62 m² 6.86 m

Grand total: 4 224.19 m²

1 : 500

Area Plan

1 : 100

Floor Plan - First Floor

1 : 500

First FloorUNIT 2

UNIT 2

Ground Floor

Plate Height

Head Height

Pad Level

First Floor

Head Height - FirstPlate Height - First

21002400

5.00°

8.00°

SELECTED

COLORBOND

ROOF

SELECTED

COLORBOND

ROOF

SELECTED

COLORBOND

ROOF

SELECTED

NEWPORT

CLADDING

SELECTED AXON

CLADDING

SELECTED

NEWPORT

CLADDING

9.00°

140sq. HWD

TIMBER

POSTS

300

2448 AUTO PANEL LIFT

320

2740

2100

600

400

600

600

Ground Floor

Plate Height

Head Height

Pad Level

First Floor

Head Height - FirstPlate Height - First

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

1 : 100

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Elevations - UNIT 2

2.4.20

301 A

PRELIMINARY2.4.20

1 : 100

Elevation 1

1 : 100

Elevation 2

1 : 100

Elevation 3

1 : 100

Elevation 4

UNIT 2

Tap

Tap

FDFD

S

S

S

S

S

S

2-WAY

2-WAY

ME

TE

R B

OX

2-WAY

2-WAY

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

1 : 100

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Electrical Plan

2.4.20

400 A

PRELIMINARY2.4.20

Electrical FixturesDescription Count

2 - Way Light Switch 2

2 Bulb & Sensor Spot Light 1

Ceiling Fan 5

Data Point 1

Double Fluroesent 1

Double Power Outlet 14

Double Power Outlet w/ USB 1

Downlight w/ energy efficient bulb 32

Exhaust Fan 2

External Bunker Wall Light 2

Meter Box 1

Seperate Sensor 1

Single Power Outlet 4

Smoke Alarm 6

Telephone Outlet 2

TV Outlet 2

Two Globe Heat Lamp & Exhaust Fan 2

Weatherproof Double Power Outlet 1

S

ELECTRICAL LEGEND

DOWNLIGHT w/ ENERGY EFFICIENT BULBS

DOUBLE FLUORESCENT

OYSTER LIGHT

POWER OUTLETS

TELEVISION OUTLET

EXHAUST FAN

WEATHERPROOF POWER OUTLETS

TELEPHONE OUTLET

SMOKE ALARM

CEILING FAN

EXTERNAL BUNKER WALL LIGHT

TWO GLOBE HEAT LAMP & EXHAUST FAN

GAS METER

SEPERATE SENSOR

EXTERNAL 2 BULB & SENSOR SPOT LIGHT

REVERSE CYCLE AIR CONDITIONER

LIGHT SWITCHES TO BE 1150 ABOVE FFL.WALL LIGHTS TO BE 1800 ABOVE FFL.

POWER POINTS TO BE 300 ABOVE FFL.UNLESS STATED OTHERWISE.

FEATURE LIGHT

DATA POINT

NBN HOME DISTRIBUTOR

METER BOX

PENDANT LIGHT

DOUBLE POWER OUTLET w/ USB

DOWNLIGHT w/ BUILT-IN SENSOR

F CIRCULAR FLURO

1 : 100

Electrical - Ground1 : 100

Electrical - First

UNIT 2

70 1440 70 1290 3000

70

600

1000

800

70 1440 70 980 70 1040 2200

70

1090

70

990

70

KITCHEN

FOHC

F/S GC

OHC

DW

SHELVES

P'TRY

OH

CW

M

Dry

r.

L'DRY

70

2750

70

70 600 1020 70

PWD

SERVICES

70 2230 70

300

70

70

990

70

495

495

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

1 : 50

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Internal Elevations

2.4.20

500 A

PRELIMINARY2.4.20

3D Kitchen1 : 50

Callout Kitchen

1 : 50

Callout Laundry 3D Laundry1 : 50

Callout PWD 3D PWD

UNIT 2

FD

FD

BATH

BATH 1520

70 900 790 70

70

900

100

1000

880

70

70

2000

880

70

70 1690 70

ENSUITE

70 1600 100 1300 70

70

1800

70

70

900

900

70

70 3000 70450

450

WC

450

450

70

900

70

70 2040 70

Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads

PHONE: 0410 648 059ABN: 25 367 288 616

EMAIL: [email protected]

CLIENT:

SITE

DETAILS:

PROJECT:

JOB No:

ISSUE:DWG No:

SCALE:

DATE:

DRAWN:

A

ISS DATE DESCRIPTION

COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS

Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local

Authority regulations & BCA.All drawings copyright to STROUD HOMES.

JDM

QBSA LIC. 1212800

A3A3A3A3

1 : 50

LOT 7 SIREC WAY BURLEIGH HEADS

UNIT 2

Internal Elevations

2.4.20

501 A

PRELIMINARY2.4.20

1 : 50

Callout Bathroom

1 : 50

Callout Ensuite

1 : 50

Callout WC

3D Bathroom

3D Ensuite

3D WC

3D Stairs

3D Stairs SectionUNIT 2