LONGER SPANS PRECAST INSULATED FLOOR PLANK · Load tables are intended for use as a general design...

4
FEATURES Clear span up to 40 feet Rigid, durable floor system Speed of construction - floor installed in hours Insulated, ready to finish Add valuable living space, including under the garage Versatility Quality control Fire resistance Can be part of a precast basement package - or total precast house Reduced sound transmission (866) 699-2557 Learn more at www.northeastprecast.com LONGER SPANS PRECAST INSULATED FLOOR PLANK TM BY NORTHEAST PRECAST

Transcript of LONGER SPANS PRECAST INSULATED FLOOR PLANK · Load tables are intended for use as a general design...

FEATURES• Clear span up to 40 feet• Rigid, durable floor system• Speed of construction - floor installed in hours• Insulated, ready to finish• Add valuable living space, including under the

garage• Versatility• Quality control• Fire resistance• Can be part of a precast basement package - or

total precast house• Reduced sound transmission

(866) 699-2557Learn more at www.northeastprecast.com

LONGER SPANS

PRECAST INSULATED FLOOR PLANK

TM

BY NORTHEAST PRECAST

HOMES AT THE SHORE

PIER AND BEAM CONSTRUCTION

INTEGRATES WITH SUPERIOR WALLS

MULTI-LEVEL COMMERCIAL

ELEVATED FIRST FLOOR

APARTMENTS

BLOCK OR POURED WALL

#3 REBAR @ 12" O.C.CAST INTO BLOCK WALL

BEND INTO C.I.P. TOPPING(BY OTHERS)

2" C.I.P. TOPPING

BEARING END OF PLANK

PLANK ON BLOCK WALL

DEP

TH V

ARI

ES

2" C.I.P. TOPPINGWITH W.W.M.

PRECAST WALL

2"

PLANK ON PRECAST WALL

512"

12" GAP

BEARING END OF PLANK

INSERT FOR SILL PLATECONNECTION

BEARING DETAIL

10” DEEP SYSTEM SPAN IN FEET

12 14 16 18 20 22 24 26 28

STRAND CONFIG LIVE LOAD IN PSF

26-S 284 198 142 104 77 56 41 28

36-S 121 93 70 52 36 25

12” DEEP SYSTEM SPAN IN FEET

18 20 22 24 26 28 30 32

STRAND CONFIG LIVE LOAD IN PSF

26-S 153 116 88 67 51 38

36-S 165 133 105 83 65 49 37

14” DEEP SYSTEM SPAN IN FEET

22 24 26 28 30 32 34 36 38 40

STRAND CONFIG LIVE LOAD IN PSF

26-S 120 93 73 56 43 32

36-S 183 146 118 95 77 62 50 38

46-S 172 142 114 93 74 60 47 37 28

TYPICAL FLOOR PLANK DETAILS

STANDARD LOAD TABLES

Notes:1. Load tables are intended for use as a general design guide. Complete

design must be performed by engineer and depends on individual conditions.

2. Longer spans and heavier loads are available. Consult with Northeast Precast for more information.

3. Capacities shown are in addition to an allowed 25 PSF dead load, to account for topping weight. Other topping configurations possible.

4. System depth includes the required 2” C.I.P. topping

SYST

EM D

EPTH

92 Reese RoadMillville, NJ 08332

(866) 699-2557www.northeastprecast.com

Superior Walls brand products are manufactured and installed by independently owned and operated factories licensed by

Superior Walls of America, LTD.

ABOUT SUPERIOR WALLSSuperior Walls foundations feature patented, insulated, precast concrete wall panels that are formed in a factory-controlled setting and delivered to the job site, where the panels are lifted into position with a crane and carefully bolted together and sealed. The walls are custom-designed and built to virtually any architectural style, complete with window and door openings.

Superior Walls panels are available in a variety of standard heights and custom lengths to suit your project. The maximum axial load (uniform house weight) for this product is 7,500 pounds per linear foot. Special point loads up to 50,000 pounds can be accommodated.

QUALITY ASSURANCE Each manufacturing plant is regularly inspected by an independent third-party inspection agency to ensure compliance with the Quality Assurance program. In addition, manufacturing and installation personnel are certified by Superior Walls of America, Ltd.

DAMPPROOFING The concrete used in the Superior Walls wall systems provides protection against freeze/thaw cycles and water vapor transmission. The urethane sealant used between panels provides superior protection against water penetration. Therefore, no additional dampproofing materials are required.

VAPOR BARRIER No vapor barrier required. Permeance of the Superior Walls panels have been tested in accordance with ASTM E 96.

FIRE RESISTANCE Superior Walls products do not require the attachment of a 15-minute thermal barrier. Ref ICC-ES ESR-1662.

Superior Walls products qualify as a two-hour fire separation wall when two layers or 5/8” Type ‘X’ drywall are applied to the studs.

INTEGRATES WITH SUPERIOR WALLS

INTEGRATES WITH SUPERIOR WALLS

INTEGRATES WITH SUPERIOR WALLS

TM

BY NORTHEAST PRECAST