LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with...

16
GE Medical Systems – Americas: 888-202-5528 P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A. GE Ultrasound - Europe: +49-212-28020 P.O. Box 1105 60 D-42665 Solingen GE Ultrasound - Asia: 65-291-8528 Singapore: 298 Tiong Bahru Road, #15-01/06 Tiong Bahru Plaza, Singapore 168730 Internet: http://www.gemedicalsystems.com Product Data R3.0.1 September 21. 2010 LOGIQ P6 Pro TruScan Imaging Technology Product Description - Wheel diameter: 12.5cm - Integrated locking mechanism that provides rolling lock and optional caster swivel lock The LOGIQ P6 PRO is a high end , highly mobile and easy to use, performance multipurpose color Doppler imaging system, designed for Obstetrics, Gynecology, Cardiology, Musculoskeletal, Vascular, Urological, Small Parts, Superficial, Pediatric, Neonatal, Trancranial, Abdominal and other applications. Probe Holders, Removable for Cleaning and Washing Gel Holder, Removable for Cleaning and Washing Air Filters, Easily Removable Front Handle System Architecture User Interface Operator Keyboard TruScan Architecture – GE’s exclusive, software-intensive platform provides unsurpassed computational power, image-manipulation capabilities, real time 4D capabilities, workflow flexibility and product upgrade-ability. Width: 43cm Height: 84/90cm 17mm spacing Alphanumeric Keyboard Ergonomic Hard Key Operations Indicator Lights Identify Activated Keys Image Quality unmatched Image Quality is achieved by leveraging features such as Phase Inversion Harmonics, CrossXBeam, SRI-HD, and unique Coded Technologies paired with world class transducers. Dimensions and Weight Integrated Recording Keys for Remote Control of Up to 2 Peripheral Devices and DICOM Devices Height: - Max 1525/1465 mm - Min. 1360/1300 mm 8 TGC Pods, with Re-mapping Functionality at Any Depth Width: 430mm Depth: 640mm Raw Data is GE’s-exclusive technology that allows a virtual rescan on archived images by applying the same scan controls available during the original exam. Weight: approx. 80 kg (176 lb.) Monitor Electrical Power 17 inch TFT LCD, Voltage: 100-120Vac or 220-240Vac XGA Format: Frequency: 50/60 Hz SmartScan utilizes new advances in operating algorithms and system operations to improve image acquisition and patient throughput while increasing diagnostic confidence and exam consistency. - Display size: 1024 x 768 Power: Max. 950 VA with Built-in and On-Board Peripherals Tilt/Rotate/Translate - Tilt Angle +40°- -90° Maximum Thermal Output: 2500 - Rotate Angle: +/-90° BTU/hr. - Translate Horizontal +/- 442 mm Console Design - Translate Vertical 165 mm Digital Brightness/Dim Bright/Contrast Adjustment ComfortScan, our most advanced ergonomic designed software suite ever, helps maximizing productivity. It simplifies every exam you perform. 3 Active Probe Ports Integrated HDD (Capacity : 250GB) Integrated DVD-R/W Drive System Overview On-board Storage for Peripherals (Max 3 peripherals) Applications General Specifications - B/W-printer, color printer, DVD video recorder Abdominal Obstetrical Wheels Gynecological LOGIQ P6 Product Data Sheet Page 1

Transcript of LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with...

Page 1: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

GE Medical Systems – Americas: 888-202-5528 P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A. GE Ultrasound - Europe: +49-212-28020 P.O. Box 1105 60 D-42665 Solingen GE Ultrasound - Asia: 65-291-8528 Singapore: 298 Tiong Bahru Road, #15-01/06 Tiong Bahru Plaza, Singapore 168730

Internet: http://www.gemedicalsystems.com Product Data R3.0.1 September 21. 2010

LOGIQ P6 Pro TruScan Imaging Technology

Product Description - Wheel diameter: 12.5cm

- Integrated locking mechanism that provides rolling lock and optional caster swivel lock

The LOGIQ P6 PRO is a high end , highly mobile and easy to use, performance multipurpose color Doppler imaging system, designed for Obstetrics, Gynecology, Cardiology, Musculoskeletal, Vascular, Urological, Small Parts, Superficial, Pediatric, Neonatal, Trancranial, Abdominal and other applications.

• Probe Holders, Removable for Cleaning and Washing

• Gel Holder, Removable for Cleaning and Washing

• Air Filters, Easily Removable • Front Handle

System Architecture User Interface Operator Keyboard TruScan Architecture – GE’s exclusive, software-intensive platform provides unsurpassed computational power, image-manipulation capabilities, real time 4D capabilities, workflow flexibility and product upgrade-ability.

• Width: 43cm • Height: 84/90cm • 17mm spacing Alphanumeric

Keyboard • Ergonomic Hard Key Operations • Indicator Lights Identify Activated

Keys Image Quality unmatched Image Quality is achieved by leveraging features such as Phase Inversion Harmonics, CrossXBeam, SRI-HD, and unique Coded Technologies paired with world class transducers.

Dimensions and Weight • Integrated Recording Keys for Remote

Control of Up to 2 Peripheral Devices and DICOM Devices

• Height: - Max 1525/1465 mm - Min. 1360/1300 mm

• 8 TGC Pods, with Re-mapping Functionality at Any Depth

• Width: 430mm • Depth: 640mm Raw Data is GE’s-exclusive technology

that allows a virtual rescan on archived images by applying the same scan controls available during the original exam.

• Weight: approx. 80 kg (176 lb.)

Monitor Electrical Power • 17 inch TFT LCD, • Voltage: 100-120Vac or 220-240Vac • XGA Format: • Frequency: 50/60 Hz

SmartScan utilizes new advances in operating algorithms and system operations to improve image acquisition and patient throughput while increasing diagnostic confidence and exam consistency.

- Display size: 1024 x 768 • Power: Max. 950 VA with Built-in and On-Board Peripherals • Tilt/Rotate/Translate

- Tilt Angle +40°- -90° • Maximum Thermal Output: 2500 - Rotate Angle: +/-90° BTU/hr. - Translate Horizontal +/- 442 mm

Console Design - Translate Vertical 165 mm • Digital Brightness/Dim

Bright/Contrast Adjustment ComfortScan, our most advanced ergonomic designed software suite ever, helps maximizing productivity. It simplifies every exam you perform.

• 3 Active Probe Ports • Integrated HDD (Capacity : 250GB) • Integrated DVD-R/W Drive

System Overview • On-board Storage for Peripherals (Max 3 peripherals) Applications General Specifications - B/W-printer, color printer, DVD video recorder

• Abdominal • Obstetrical

• Wheels • Gynecological

LOGIQ P6 Product Data Sheet Page 1

Page 2: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

• Cardiac • Drawer • CINE Memory (60 sec) (256 MB)> 1000 Frames depending on depth, FOV, line density, etc.

• Musculoskeletal • Probe Cable Hanger • Vascular • Urology Probe Holder • Urological • Real-time Triplex mode at any depth

and any PRF • Stress Echo Package

• Small Parts and Superficial • PFD (Pulsatile Flow Detection) • Breast • Crossbeam • Tissue Velocity Imaging (TVI), with Q-

Analysis • Pediatric and Neonatal • Speckle Reduction Imaging (SRI-HD) • Trancranial • Report Designer

• 1-pedal and 3-Pedal Foot Switch, with programmable functionality

• Endocavitary • Automatic Optimization • Intraoperative • ATO : Auto Tissue Optimization

• Remote Control Switch • Transesophageal • Auto TGC • On-board electronic documentation

(PDF Format) • ASO : Auto Spectrum Optimization Scanning Methods • ACO : Auto Color Optimization

• Electronic Sector • Coded Harmonic Imaging Media & Peripheral Options • Electronic Convex • Coded Excitation • Integrated Mounting Kits and Remote

Controls Provided for • Electronic Linear • Virtual Convex • Real Time 4D Volume Sweep • Patient Information Database • Image Archive on CD/DVD and Hard

Drive - B/W Digital thermal printer

Transducer Types - Digital Color A6 Digital thermal printer • Easy Backup to Media for data

security • Sector Phased Array - Digital Color A5 Digital thermal printer • Convex Array - DVD Video Recorder

• TruAccess, Raw Data Processing and Analysis

• Microconvex Array • Linear Array Display Modes • Real-time Automatic Doppler Calcs • Single CW (Pencil) Probes • Live and Stored Display Format: Full

size and split screen - both w/ thumbnails. For Still and CINE

• OB Calcs • Bi-plane Microconvex Arrays • Fetal Trending • Volume Probes (4D) • Multi Gestational Calcs • Review Image Format: 4x4, and

"thumbnails". For Still and CINE • Hip Dysplasia Calcs Operating Modes • Gynecological Calcs • Simultaneous Capability • B-Mode • Vascular Calcs - B/PW • Coded Harmonic Imaging • Cardiac Calcs - B/CFM or PDI • M-Mode • Urological Calcs - B/M • Color Flow Mode (CFM) • Renal Calcs - B + CFM/M • Power Doppler Imaging (PDI) with

Directional Map • InSite Capability - Realtime Triplex Mode (B + CFM or PDI/PW) • iLinq Capability • PW Doppler with High PRF

- B-Flow + PW (option) • On-board electronic documentation (XPS format)

• M-Color Flow Mode - Dual B (B/B) • Anatomical M-Mode (option) - Dual B + CFM or PDI • MPEGVue • B-Flow Mode (option) - B/PFD (option) • Key macro • B-Flow Color Mode (option) • Selectable Alternating Modes • Network Storage • Coded Contrast Imaging (option) - B/M • Quick Save • CW Doppler Mode (option) - B/PW • PFD Mode (option) - B + CFM/M System Options • Tissue Velocity Imaging (TVI) Mode

(option) - B + CFM (PDI)/PW

• Auto IMT - B-Flow + PW (option) • Elastography on 11L • 3D/4D Volume Modes (option) - 3D – Mode

- 3D Static • Easy 3D (Baby Face, Vascular) - 3D – Color Mode (option) - 4D Realtime - B/CW (option) • Advanced 3D, with 3D Landscape

- B + CFM (PDI)/CW (option) • Elastography (option) • DICOM 3.0 Connectivity - B + PFD/PW (option) - • LOGIQView • Simultaneous Up/Down Display with

Bi-plane probe • B-Flow color System Standard Features

• Hybrid Contrast Imaging - B • Hard Disk partition of 50GB for image storage

• Anatomical M-Mode - B/CFM • Real Time 4D • Multi Image Split Screen

• Without compression: - Live and/or frozen • ECG • Raw DICOM: capacity 33000 images - B + B/CFM or PDI • ECG Cable • DICOM: - B+B/PFD (option) • Steered CWD

- Independent CINE playback • Image Only: > 17,000 images • Rear Handle

LOGIQ P6 Product Data Sheet Page 2

Page 3: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

- Quad screen format - Time Scale • 348 Pre-defined Annotations and User Programmable Libraries/Annotations

• Zoom: Write/Read/Pan • Doppler Mode • Colorized Image - Gain - Colorized B - Angle • Body Patterns: 140 human types plus

14 animal types - Colorized M - Sample Volume Depth and Width - Colorized PW - Wall Filter • Customized Comment Home

Position - Colorized CW (option) - Velocity and/or Frequency Scale - Colorized B-Flow (option) - Spectrum Inversion

- Time Scale • Time line Display Complete User Manual available on board through Help (F1) - Independent Dual B/PW Display - PRF

- Display Formats: - Doppler Frequency User Manual and Service Manual are included on CD with each system. A printed Manual is available upon request.

Top/ Bottom selectable format (Size: 1/2:1/2; 1/3:2/3; 2/3:1/3)

• Color Flow Mode - Line Density

Side/Side selectable format - Frame Averaging (1/2:1/2; 1/3:2/3; 0:1) - Packet Size

- Color Scale Switchable after freeze - Color Velocity Range and Baseline • Virtual Convex CINE Memory/Image Memory - Color Threshold Marker • CrossBeam • CINE Memory: 256MB - Color Gain • Tissue Velocity Imaging (TVI) Mode

(option) • Dual Image CINE Display

- PDI • Quad Image CINE Display - Color Scale Inversion • Elastography and simultaneous

B/Elasto • CINE Gauge and CINE Image Number

Display - Color Doppler Frequency

• TGC Curve • CINE Review Loop • Acoustic Frame Rate • CINE Review Speed: 20 steps (10, 20,

30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 300, 400, 500, 600, 700, 800, 900, 1000%)

• Cine Frame Number Display Annotation • VCR Counter • 1st. Patient Name: First, Last, & Middle

name each store 27 characters. Up to 64 total characters displayed.

• VCR Status • VCR Playback Counter • Selectable CINE Sequence for CINE

Review • Body Pattern • 2nd. Patient ID: 31 characters. Up to 27 total characters displayed. • Application Name • Measurements, Calculations and

Annotations on CINE Playback • Measurement Results • Age, Sex and Birth Date (optional) • Operator Message • Hospital Name: 23 characters. • Scrolling Timeline Memory • Displayed Acoustic Output • Date: 3 Types selectable

MM/DD/YY, DD/MM/YY,

• Cine Capture Function - TIS: Thermal Index Soft Tissue • Digital Continuous CINE Capture - TIC: Thermal Index Cranial (Bone) - TIB: Thermal Index Bone • YY/MM/DD Image Storage - MI: Mechanical Index • Time: 2 types selectable • On-board database of patient

information from past exams • % of Power output • 24 hours, 12 hours • Biopsy Guide Line and/or Zone • Gestational Age from

LMP/EDD/GA/BBT • Storage Format: DICOM/Raw Data

• Heart Rate • DICOM Still Image Storage Size: • Probe Name - Gray Image: ~300K to ~1.3 MB General System Parameters • Gray Map names - Color Image: ~900K to 1.9 MB • Probe Orientation • Multi frame System Setup • Depth Scale Marker • Display Format: Full size, 4x4, and

"thumbnails" • Lateral Scale Marker • 8 Pre-programmable Categories • Live image and stored image side-by-

side display • Focal Zone Markers • User Programmable Preset Capability • Image Depth • Factory Default Preset Data

• CD-R storage: 650, 700 MB • Zoom Depth • Languages: English, French, German, Spanish, Italian, Portuguese, Russian, Greek, Swedish, Danish, Dutch, Finnish, Norwegian, Japanese

• DVD storage: -R (4.7GB) • B-Mode - Gain • Conversion to JPEG, AVI (SaveAs) and

WMV (MPEGvue) file formats - Dynamic Range - Imaging Frequency • Internal Hard Drive partition of 50 GB

for Image Storage • OB Report Format: 5 Types, Tokyo

Univ., Osaka Univ., USA, Europe, and ASUM

- Edge Enhance - Frame Averaging • External USB 2.0 Hard Drive support

for Import, Export, DICOM Read, SaveAs

- Gray Map • EFBW: 10 types, Japan, USA and Europe (Tokyo Univ., Osaka Univ., Tokyo Shinozuka, JSUM, German, Shephard, Merz, Hadlock/Shephard, Williams, Brenner)

- ATO On/Off • M-Mode • MPEGVue file Export

- Gain • USB 1.1 / 2.0 Memory Stick support for SaveAs and MPEGVue - Dynamic Range

LOGIQ P6 Product Data Sheet Page 3

Page 4: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

• Thermal Index: TIC, TIS, TIB • Arbitration Threshold: 15 steps pre-settable

• Network Storage support for Import, Export, DICOM Read, SaveAs, MPEGVue

• Softener: 4 steps • Focus Number: 8 steps • Auto Line Density: On/Off pre-settable • Focus Width: 3 types • PW/CF Ratio: 1, 2, 4 • Range Focus: On/Off • Accumulation: 8 steps Connectivity

• Compression: 0.5 – 1.5, 0.1 step • Ethernet network connection • Line Density: 4 steps Power Doppler Imaging • RS-232 serial data output (need a

converter cable) • Line Density Zoom: 4 steps • PDI Map: 13 types • Suppression: 6 steps • CF/PDI Flash Suppression: 2 steps • DICOM 3.0 (option) • Frame Average: 8 steps • CF/PDI Focus Depth: default pre-

settable for 0 – 100 % of ROI in depth, 10 % step

- Verify • Edge Enhance: 6 steps - Print • Scanning Size (FOV or Angle): probe dependent, see probe specifications - Store

• CF/PDI Acoustic Output: 0 – 100%, 10% step

- Modality Worklist • Gray Scale Map: 23 types - Storage Commitment • Clear Map: 23 types • CF/PDI Angle Steer: 0, +/- 20° - Modality Performed Procedure Step (MPPS) • Tint Map: 10 types • Packet Size: 5 – 16, dependent on

probe/application • Gain: 0 – 98 dB, 2 dB step - Media Exchange • Dynamic Range: 30 – 120 dB, 3 dB step • Spatial Filter: 6 steps - Off network / mobile storage queue • Frame Average: 7 steps - Query/Retrieve; supported on Centricity and other compatible vendors

• Depth: 1 – 30 cm, 1 cm step, depend on probe.

• PRF: 280 Hz – 19600 Hz • Power Threshold: 0 – 100 %, 5 % step

• Rejection: 6 steps • Arbitration Threshold: 15 steps pre-settable

- Structured Reporting; compatible with LOGIQworks • Frequency: Up to 5 steps, depend on

probe • Gain: 0 – 40 dB, 0.5 dB step - Public SR Template • Dual Beam: On/Off pre-settable • Wall Filter: 7 steps depend on probe/application

- Media Store of SR • Auto Line Density: On/Off pre-settable - iLinq capability • Diff: On/Off • CF/PDI Frequency: Up to 3 steps, depend on probe

• Steered Linear: +/- 15° Scanning Parameters • Auto Line Density: On/Off pre-settable Color Flow Mode • Transparent: 5 steps • Digital Beam former • Base Line: 0 – 100 %, 10 % step • Invert: On/Off • 7168 System processing channels • Invert: On/Off • Accumulation: 8 steps • Maximum frame rate > 700F/s • CF/PDI Focus Depth: default pre-

settable for 0 – 100 % of ROI in depth, 10 % step

• Displayed Imaging Depth: 0 – 30 cm M-Mode • Minimum Depth of Field: 0 –2cm (probe

dependent) • Sweep Speed: 8 steps • CF/PDI Flash Suppression: 2 steps • M Color: 10 types • Maximum Depth of Field: 0 – 30 cm

(probe dependent) • CF/PDI Acoustic Output: 0 – 100%, 10%

step • M/PW Display Format: V-1/3B, V-1/2B,

V-2/3B, H-1/2B, H-1/4B, TL only • Transmission Focus • CF/PDI Angle Steer: 0, +/- 20° • B/M Acoustic Output: 0 – 100 %, 2 % step

- 1 – 8 Focus Points selectable (probe and application dependent)

• Packet Size: 5 – 16, dependent on probe/application • Rejection: 6 steps • Dual Beam forming in B-Mode • Line Density: 5 steps • Dynamic Range: 30 – 120 dB, 3 dB step • Continuous Dynamic Receive

Focus/Aperture • Line Density Zoom: 5 steps • Edge Enhance: 6 steps • Frame Average: 7 steps • Gray Scale Map: 23 types • Multi-Frequency/Wideband Technology • PRF: 280 Hz – 19600 Hz • Clear Map: 23 types • Frequency Range 1 to 15MHz • Spatial Filter: 6 steps • M Gain: 0 – 98 dB, 2 dB step • 256 Shades of Gray • Gain: 0 – 40 dB, 0.5 dB step • Up to 197 dB Processing Dynamic

Range • Wall Filter:4 steps depend on

probe/application Anatomical M-Mode • M-mode cursor adjustable at any plane • 16,777,216 Hues of Color • Scanning Size (FOV or Angle): probe

dependent • Can be activated from a CINE loop from

a live or stored image Adjustable Field of View (FOV) up to 170 degree depending on probe • CF/PDI Vertical Size (mm) of ROI: default

pre-settable • Available with Color Flow Mode • Image Reverse: Right/Left • M & A capability • Image Rotation: 4 steps • CF/PDI Center Depth (mm) of ROI:

default pre-settable Rotation: 0°, 90°, 180°, 270° PW/CW-Mode • CF/PDI Frequency: Up to 3 steps,

depend on probe • Maximum and Minimum Velocity Scales B-Mode - Max: 10 m/sec • B/M Acoustic Output: 0 – 100%, 2%

step • Color Map: 20 types depend on

application - Min: 5 cm/sec • Gray Scale Map: 4 types • Image Reverse: On/Off • Transparent: 5 steps • Dynamic Range: 24 – 60, 4 dB step • B Color: 10 types • Color Threshold: 0 – 100 %, 5 % step

LOGIQ P6 Product Data Sheet Page 4

Page 5: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

• Base Line: 5 – 95 %, 11 steps • Algorithm works on focal zone/ number and depth changes

• Line Density Zoom: 4 steps • SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14,

16 mm • Suppression: 6 steps

• Available on stored or live image • Edge Enhance: 6 steps • Available in B-Mode, B-Flow, PW

Doppler, and Color Doppler • Angle Correct: +/- 90°, 1° step • Gray Scale Map: 23 types • Spectral Color: 6 types • Clear Map: 23 types • PW Sweep Speed: 8 steps • Tint Map: 10 types • Invert: On/Off • Gain: 0 – 98 dB, 2 dB step B-Flow (option) • M/PW Display Format: V-1/3B, V-1/2B,

V-2/3B, H-1/2B, H-1/4B, TL only • Dynamic Range: 30 – 120 dB, 3 dB step • Available on 8L, 9L, 11L, i739, T739, i12L,

4C, 5CS and 4D3C-L, 4D5C-L Probes • Rejection: 6 steps • Duplex: On/Off (PW only) • Auto Line Density: On/Off pre-settable • Background: On/Off • PW Acoustic Output: 0 – 100 %, 10 %

step • Frequency: Up to 5 steps, depend on

probe • Sensitivity/PRI: 14 steps • Line Density: 4 steps

• Spectral Averaging: 6 steps • Edge Enhance: 6 steps • Time Resolution: 4 steps Coded Excitation • Frame Average: 8 steps • PW/CF Ratio: 1, 2, 4 • Available on the following probes the

Following Probes • Gray Scale Map: 23 types

• Rejection: 15 steps • Clear Map: 23 types • Gain: 0 – 32 dB, 1 dB step - 11L • Tint Map: 10 types • Wall Filter: 5 – 1500 Hz, 22 steps,

depend on probe/application - 8C • Dynamic Range: 30 – 120 dB, 3 dB step - E8C • Rejection: 6 steps

• PW Angle Steer: 0, +/- 5, 10, 15, 20° - E8CS • Gain: 0 – 98 dB, 2 dB step • PRF: 640 – 29800 Hz with PW, 50000 Hz

with CW - ERB • Auto Line Density: On/Off pre-settable

• Dual Beam: On/Off pre-settable • Sample Volume Depth: 29 steps default

pre-settable • B-Flow Color: 8 color maps and 3

directional color maps Virtual Convex • Provides a Convex Field of View for

Convex, Linear and Sector probes • CW-Mode (option) is Available on the Following Probes

• Accumulation: 8 steps • Available on the Following Probes - 3S Elastography Mode (option) - 8L - 7S - 9L • Elasto Acoustic Output: 0 – 100% - 3Sp - 11L • Line Density - 5Sp - i12L • Elasto Frequency - P2D - T739 • Frame Average - P6D - I739 • Axial Smoothing - 3S • Later Smoothing

Coded Harmonic Imaging - 5S • Window • Available on the Following Probes - 7S • Frame Reject

- 3CRF - 3Sp • Noise Reject - 4C - 5Sp • Transparency Map - 5CS - ERB - Linear • Color and Gray Map - E8C - 4C • Soft Compress - E8CS - 5CS • Hard Compress - 8C - 4D3C-L • Quality Graph : On/Off - ERB - 4D5C-L • Available on the following Probes - BE9CS - 3CRF • 11L - 3S - 8C • ML6-15 - 5S - E8C - 7S - 4D8C Auto IMT (option) - 3Sp - UG7C • Automated measurement of the

intimae media thickness of common carotid artery

- 5Sp - 8L Automatic Optimization - 9L Result window displayed on screen • Optimize B-Mode, B-Flow image to

improve contrast resolution. - 11L - i12L • Selectable amount of contrast

resolution improvement (low, medium, high)

Hybrid Contrast Imaging (option) - i739 • Coded Harmonic Angio: Available on

4C, 5CS, i739 and t739 probes - T739 - 4D3C-L • Auto-TGC in B-Mode and Color –

adjusts overall and axial gain - Tissue Background Selection: 4 steps - 4D5C-L • Dual side by side display of the

fundamental and contrast enhanced image

- 4DE7C • Optimize Spectral Waveform – adjusts baseline, invert, PRF (on live image), and angle correction

- 4D8C - UG7C

• TruAgent Detection: Available on 4C and 5CS probes

• Softener: 4 steps • Line Density: 4 steps

LOGIQ P6 Product Data Sheet Page 5

Page 6: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

- 2 frequencies on 4C and 5CS probes • Frame Average: 7 steps Auto Movie - Monitor Mode • PRF: 280 Hz – 19600 Hz Undo

• Coded Phase Inversion: • Power Threshold: 0 – 100 %, 5 % step Reset • Arbitration Threshold: 15 steps pre-

settable 3 types, Available on 4C and 5CS probes

Advanced 3D (option) • Gain: 0 – 40 dB, 0.5 dB step 1 type, Available on i739, t739 probes • Acquisition of Color data - Tissue Background Selection: 4 steps • Wall Filter: 4 steps • Automatic rendering • Visulaization Contrast Imaging: • CF/PDI/PFD Frequency: Up to 3 steps,

depend on probe • 3D Landscape technology Available on 4C, 5CS, i739 and t739 probes • 3D Movie • Auto Line Density: On/Off pre-settable

• Main Mode • Transparent: 5 steps -Display Tissue image and Contrast Enhanced image simultaneously in split screen

• Invert: On/Off CrossBeam • Accumulation: 8 steps • Provides Spatial Compounding • Max Enhancement: On/Off • Available on the linear and convex

probes SRI-HD • Gray Scale Map: 21 types

• Colorite on/ off • High Definition Speckle Reduction Imaging - 3CRF • Clear Map: 21 types

- 4C • Contrast Clock Display • Provides 6 levels of speckle reduction - 5CS • Time Trigger Scan: 0.3, & 0.5 – 10 sec,

0.5 sec step • Side by Side Display

- 8C • Available on all probes - E8C • Time Intensity Curve Analysis • Compatible with ALL scanning modes - E8CS • Accumulation: 8 steps • Compatible with Side by Side Display - 8L • SRI-HD • Pre and post processing - 9L - 11L The LOGIQ P6 Pro is designed for

compatibility with commercially available ultrasound contrast agents. Because the availability of these agents is subject to government regulation and approval, product features intended for use with these agents may not be commercially marketed nor made available before the contrast agent is cleared for use. Contrast related product features are enabled only on systems for delivery to an authorized country or region of use. GE Medical Systems makes no claims concerning the safety or effectiveness of contrast agents.

TVI (option) - T739 • Myocardial Doppler Imaging with color overlay on tissue image

- BE9C - BE9CS • Available on all sector probes - 4D3C-L • Tissue color overlay can be removed to

show just the 2D image, still retaining the tissue velocity information

- 4D5C-L - 4DE7C - 4D8C • Curved Anatomical M-mode: free

(curved) drawing of M-mode generated from the cursor independent from the axial plane

- ERB - UG7C

• Provides 3, 5 or 7 angles for Compounding on Linear probes, 3 or 5 angles on Convex probes

• Q-Analysis: Multiple Time -Motion trace display from selected points in the myocardium • Compatible with Side by Side Display

• Compatible with: Color mode, Timeline mode, SRI-HD, Coded Harmonic Imaging, Virtual Convex on linear probes

Real Time 4D (option) • Acquisition Modes: LOGIQView (option) - Realtime 4D Bmode • Available on all probes - Static 3D Bmode • Extended Field of View Imaging • Visualization Modes: PFD (option) • For use in B-Mode - 3D Rendering (diverse surface and

intensity projection modes) • Available on all probes • LOGIQView Status • PFD Map: 4 types • Auto detection of scan direction - Sectional Planes (3 Section planes

perpendicular to each other) - PFD directional / pulsatile: 2 types • Pre or post-process zoom up to 10X - PFD pulsatile / non pulsatile: 2 types • Rotation • Render Mode:

• PFD Type: 6 steps • Auto best fit on monitor - Surface texture, Surface Smooth, max-, min- and X-ray (average intensity projection), Gradient, Inversion, Glass Body, Mix Mode of two render Modes

• PFD Scale: 1-109, 3 step • Measurements in B-Mode • CF/PDI/PFD Flash Suppression: 2 steps • Up to 60 cm scan length • CF/PDI/PFD Focus Depth: default pre-

settable for 0 – 100 % of ROI in depth, 10 % step

Easy 3D (option)

• Curved 3point Render start Colorize • CF/PDI/PFD Acoustic Output: 0 – 100%, 10% step

• 3D Movie Threshold (Opacification) • Scalpel: 3D Cut tool Render • CF/PDI/PFD Angle Steer: 0, +/- 20° • Display Format: Texture • Packet Size: 5 – 16, dependent on

probe/application - Quad: A-/B-/C-Plane/3D

Gray Surface - Dual: A-Plane/3D • Spatial Filter: 6 steps - Single: 3D or A- or B- or C-Plane Scalpel

LOGIQ P6 Product Data Sheet Page 6

Page 7: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

Audio Volume Colorize Color Flow Mode(Optional) Compression (Dynamic Range)

Pre-Processing Gain Auto Optimize (ASO) • Acoustic Power Output ROI Position, Size Color Flow Mode • Write Zoom up to 8x PRF Auto Color Optimization (ACO) • B/M-Mode Wall Filter Baseline

Baseline Color Invert Gain Angle Steer Color Map TGC Color Line Density Threshold Image Reverse Color Frequency Frame Average (in loop images)

Depth Packet Size Sweep Speed for Color M-Mode Scan Area Color Invert Anatomical Color M-Mode Auto Optimize (ATO) Color Map Easy 3D (option) Dynamic Range Threshold Colorize

Threshold (Opacification) Frame Average Focus Number Focus Position Focus Position Mix Type 1 ACE Line Density Render Spatial Filter

Frequency Texture CFM/PWD Ratio Image Rotation Gray Surface Duplex Gray Map Sweep Speed for Color M-Mode Scalpel Colorize Anatomical Color M-Mode Auto Movie

3D Acquisition Frame Average Undo Scan Distance Edge Enhance Reset ROI Style Rejection • Advanced 3D (option) Display Format Virtual Convex 3D Landscape Scan Plane

Focus Width Colorize Front to Back Suppression Threshold (Opacification) Side to Side B Softener Acquisition Mode Re-slice

Parallel M/D Cursor Type 1/2 Sweep Sweep Speed for M-Mode Group Planes PW-Mode Scalpel Post-Processing w/TruAccess (Raw Data) Gain

Define Axis SRI- 5 Selectable level Sample Volume Depth Visible Data Read Zoom up to 8x PRF Tile B/M-Mode Wall Filter

Gain Baseline Active Data Dynamic Range Angle Steer Auto Movie TGC Angle Correct Rotate Image Reverse Quick Angle Correct Undo Auto Tissue Optimize (ATO) Auto Angle Correct

Reset Compression Doppler Frequency • 3D Movie Image Rotation Doppler Invert

Colorize Gray Map Display Format Colorize Sweep Speed Pause Frame Average (in loop images) Full Timeline Movie Speed Rejection Rejection Axis Sweep Speed for M-Mode Time Resolution Define Start/End Anatomical M-Mode Gray Map

Auto Movie PW/CW-Mode Colorize Movie 360° Post Gain Dynamic Range Manual Baseline CFM/PWD Ratio

Angle Correct Duplex Quick Angle Correct Auto Calcs Doppler Invert Measurements / Calculations Trace Direction Display Format Modify Calcs Sweep Speed Number of Average Cycles General B-Mode Full Timeline Trace Method • Depth & Distance Rejection Trace Sensitivity • Circumference (Ellipse / Trace) Gray Map Auto Optimize (ASO)

LOGIQ P6 Product Data Sheet Page 7

Page 8: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

• Area (Ellipse / Trace) • SYS PCCA (Systolic Proximal Common Carotid Artery)

- HL (Humerus Length) • Volume (Ellipsoid) - BD (Binocular Distance) • % Stenosis (Area or Diameter) • DIAS PCCA (Diastolic Proximal Common

Carotid Artery) - FT (Foot Length)

• Angle between two lines - OFD (Occipital Frontal Diameter) • SYS DICA (Systolic Distal Internal

Carotid Artery) - TAD (Transverse Abdominal Diameter) - TCD (Transverse Cerebellum

Diameter) General M-Mode

• DIAS DICA (Systolic Distal Internal Carotid Artery)

• M-Depth - THD (Thorax Transverse Diameter) • Distance

• SYS MICA (Systolic Mid Internal Carotid Artery)

- TIB (Tibia Length) • Time - ULNA (Ulna Length) • Slope

• DIAS MICA (Diastolic Mid Internal Carotid Artery)

• Estimated Fetal Weight (EFW) by: • Heart Rate - AC, BPD

• SYS PICA (Systolic Proximal Internal Carotid Artery)

- AC, BPD, FL General Doppler - AC, BPD, FL, HC Measurements/Calculations • DIAS PICA (Diastolic Proximal Internal

Carotid Artery) - AC, FL • Velocity - AC, FL, HC • Time • SYS DECA (Systolic Distal External

Carotid Artery) - AC, HC • A/B Ratio (Velocities / Frequency Ratio • Calculations and Ratios • PS (Peak Systole) • DIAS DECA (Diastolic Distal External

Carotid Artery) - FL/BPD • ED (End Diastole) - FL/AC • PS/ED (PS/ED Ratio) • SYS PECA (Systolic Proximal External

Carotid Artery) - FL/HC • ED/PS (ED/PS Ratio) - HC/AC • AT (Acceleration Time) • DIAS PECA (Diastolic Proximal External

Carotid Artery) - CI (Cephalic Index) • ACCEL (Acceleration) - AFI (Amniotic Fluid Index) • TAMAX (Time Averaged Maximum

Velocity • VERT (Systolic Vertebral Velocity) • Measurements / Calculations by:

Jeanty, Merz, Tokyo University, Mercer, Hansmann, Erickson, Hill, Shephard, Hadlock, Hohler, Campbell

• SUBCLAV (Systolic Subclavian Velocity) • Volume Flow (TAMEAN and Vessel Area) • Summary Reports • Heart Rate • Mean IMT Measurement Tools • PI (Pulsatility Index) • Fetal Graphical Trending • RI (Resistivity Index) • Growth Percentiles Cardiac • Multi-Gestational Calculations (4) Real-time Doppler Auto • Fetal Qualitative Description

(Anatomical survey) Measurements/Calculations Measurements / Calculations B-Mode Measurements • PS (Peak Systole) • Fetal Environmental Description

(Biophysical profile) • Aorta • ED (End Diastole) • MD (Minimum Diastole) Aortic Root Diameter (Ao Root Diam) • Programmable OB Tables • PI (Pulsatility Index) • Over 20 selectable OB Calcs Aortic Arch Diameter (Ao Arch Diam) • RI (Resistivity Index) • Expanded Worksheets Ascending Aortic Diameter (Ao Asc) • AT (Acceleration Time) Descending Aortic Diameter (Ao Desc

Diam) • ACC (Acceleration) GYN Measurements/Calculations • PS/ED (PS/ED Ratio) • Right Ovary Length, Width, Height Aorta Annulus Diameter (Ao Annulus

Diam) • ED/PS (ED/PS Ratio) • Left Ovary Length, Width, Height • HR (Heart Rate) • Uterus Length, Width, Height • TAMAX (Time Averaged Maximum

Velocity) Aorta Isthmus (Ao Isthmus) • Ovarian Volume Aorta *** (Ao st junct) • ENDO (Endometrial thickness)

• PVAL (Peak Velocity Value) • Ovarian RI • Aortic Valve • Volume Flow (TAMEAN and Vessel Area) • Uterine RI Aortic Valve Cusp Separation (AV Cusp) • Follicular measurements Aortic Valve Area Planimetry (AVA Pl

ani met ry) OB Measurements/Calculations • Summary Reports • Gestational Age by: *** ( Trans AVA) - GS (Gestational Sac) Vascular

Measurements/Calculations • Left Atrium - CRL (Crown Rump Length) Left Atrium Diameter (LA Diam) - FL (Femur Length) • SYS DCCA (Systolic Distal Common

Carotid Artery) - BPD (Biparietal Diameter) LA Length (LA Major) - AC (Abdominal Circumference) LA W idth (LA Minor) • DIAS DCCA (Diastolic Distal Common

Carotid Artery) - HC (Head Circumference) Left Atrium Diameter to AoRoot Diameter Ratio (LA/Ao Ratio) - APTD x TTD (Anterior/Posterior Trunk

Diameter by Transverse Trunk Diameter)

• SYS MCCA (Systolic Mid Common Carotid Artery) Left Atrium Area (LAA(d), LAA(s))

• DIAS MCCA (Diastolic Mid Common Carotid Artery)

Left Atrium Volume, Single Plane, Method of Disk (LAEDV A2C, LAESV

- LV (Length of Vertebra) - FTA (Fetal Trunk Cross-sectional Area)

LOGIQ P6 Product Data Sheet Page 8

Page 9: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

• Pulmonic Valve • Aorta A2C ) (LAEDV A4C, LAESV A4C) • Left Ventricle Pulmonic Valve Area (PV Planimetry) Aortic Root Diameter (Ao Root Diam)

• Aortic Valve Pulmonic Valve Annulus Diameter (PV Annulus Diam)

Left Ventricle Mass (LVPWd, LVPWs) Left Ventricle Volume, Teichholz/Cubic (LVIDd, LVI Ds)

Aortic Valve Diameter (AV Diam) Pulmonic Diameter (Pulmonic Diam) Aortic Valve Cusp Separation (AV Cusp)

• Right Atrium Left Ventricle Internal Diameter (LVIDd, LVI Ds)

Aortic Valve Ejection Time (LVET) • Left Atrium Right Atrium Diameter, Length (RAD

Ma) Left Ventricle Length (LVLd, LVLs) Left Atrium Diameter to AoRoot Diameter Ratio (LA/Ao Ratio) Right Atrium Diameter, Width (RAD Mi) Left Ventricle Outflow Tract Diameter

(LVOT Diam) Right Atrium Area (RAA) Left Atrium Diameter (LA Diam) • Left Ventricle Right Atrium Volume, Single Plane,

Method of Disk (RAAd) Left Ventricle Posterior Wall Thickness (LVPWd, LVPWs) Left Ventricle Volume, Teichholz/Cubic

(LVIDd, LVI Ds) Right Atrium Volume, Systolic, Single Plane, Method of Disk (RAAs)

Left Ventricle Length (LV Major) Left Ventricle Width (LV Minor) Left Ventricle Internal Diameter (LVIDd,

LVI Ds) • Right Ventricle Left Ventricle Outflow Tract Area (LVOT) Right Ventricle Outflow Tract Area (RVOT Planimetry)

Left Ventricle Area, Two Chamber/Four Chamber/Short Axis (LVA (d), LVA (s))

Left Ventricle Posterior Wall Thickness (LVPWd, LVPWs)

Left Pulmonary Artery Area (LPA Area) Left Ventricle Endocardial Area, Width (LVA (d), LVA(s))

Left Ventricle Ejection Time (LVET) Right Pulmonary Artery Area (RPA Area) Left Ventricle Pre-Ejection Period

(LVPEP) Right Ventricle Internal Diameter (RVIDd, RVIDs)

Left Ventricle Epicardial Area, Length (LVAepi (d), LVAepi (s)) Interventricular Septum (IVS)

Right Ventricle Diameter, Length (RVD Ma)

Left Ventricle Mass Index (LVPWd, LVPWs)

Left Ventricle Internal Diameter (LVI D) Left Ventricle Posterior Wall Thickness (LVPW) Right Ventricle Diameter, Width (RVD

Mi) Ejection Fraction, Teichholz/Cube (LVIDd, LVIDs) • Mitral Valve

Right Ventricle Wall Thickness (RVAWd, RVAWs)

Left Ventricle Posterior Wall Fractional Shortening (LVPWd, LVPWs)

E-Point-to-Septum Separation (EPSS) Mitral Valve Leaflet Separation (D-E Excursion) Right Ventricle Outflow Tract Diameter

(RVOT Diam) Left Ventricle Stroke Index, Teichholz/Cube (LVIDd, LVIDs, and Body Surface Area)

Mitral Valve Anterior Leaflet Excursion (D-E Excursion) Left Pulmonary Artery (LPA)

Main Pulmonary Artery (MPA) Left Ventricle Fractional Shortening (LVIDd, LVIDs)

Mitral Valve D-E Slope (D-E Slope) Right Pulmonary Artery (RPA) Mitral Valve E-F Slope (E-F Slope)

• System • Pulmonic Valve Left Ventricle Stroke Volume, Teichholz/Cubic (LVIDd, LVIDs) Interventricular Septum Thickness

(IVSd, IVSs) QRS complex to end of envelope (Q-to-PV close) Left Ventricle Stroke Index, Single Plane,

Two Chamber, Method of Disk (LVI Dd, LVIDs, LVSd, LVSs)

• Right Ventricle Inferior Vena Cava Pulmonary Artery Diameter (MPA) Right Ventricle Internal Diameter

(RVIDd, RVIDs) Systemic Vein Diameter (Systemic Diam)

Left Ventricle Stroke Index, Single Plane, Four Chamber, Method of Disk (LVI Dd, LVIDs, LVSd, LVSs)

Right Ventricle Wall Thickness (RVAWd, RVAWs) Patent Ductus Arterosis Diameter (PDA

Diam) Left Ventricle Stroke Index, Bi-Plane, Bullet, Method of Disk (LVAd, LVAs)

Right Ventricle Outflow Tract Diameter (RVOT Diam) Pericard Effusion (PEs)

Patent Foramen Ovale Diameter (PFO Diam)

Interventricular Septum (IVS) Right Ventricle Ejection Time (RVET) Left Ventricle Internal Diameter (LVI D) Right Ventricle Pre-Ejection Period

(RVPEP) Ventricular Septal Defect Diameter (VSD Diam)

Left Ventricle Posterior Wall Thickness (LVPW) Velocity Circumferential Fiber

Shortening (Vcf) • Mitral Valve Interventricular Septum (IVS) Fractional Shortening (IVSd, IVSs) • System Mitral Valve Annulus Diameter (MV Ann

Diam) • Tricuspid Valve Interventricular Septum Thickness (IVSd, IVSs) Tricuspid Valve Area (TV Panimetry) E-Point-to-Septum Separation (EPSS)

Tricuspid Valve Annulus Diameter (TV Annulus Diam)

Mitral Valve Area by Pressure Half Time (MVA By PHT)

Pericard Effusion (PE(d)) Interventricular Septum (IVS) Fractional Shortening (IVSd, IVSs) Mitral Valve Area Planimetry (MVA

Planimetry) M-Mode Measurements • Tricuspid Valve

LOGIQ P6 Product Data Sheet Page 9

Page 10: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

QRS complex to end of envelope (Q-to-TV close)

Doppler Mode Measurements • Aortic Valve

Aortic Insufficiency Mean Pressure Gradient (AR Trace) Aortic Insufficiency Peak Pressure Gradient (AR Vmax) Aortic Insufficiency End Diastole Pressure Gradient (AR Trace) Aortic Insufficiency Mean Velocity (AR Trace) - Aortic Insufficiency Mean Square

Root Velocity (AR Trace) - Aortic Insufficiency Velocity Time

Integral (AR Trace) - Aortic Valve Mean Velocity (AV

Trace) - Aortic Valve Mean Square Root

Velocity (AV Trace) - Aortic Valve Velocity Time Integral

(AV Trace) Aortic Valve Mean Pressure Gradient (AV Trace) Aortic Valve Peak Pressure Gradient (AR Vmax) Aortic Insufficiency Peak Velocity (AR Vmax) Aortic Insufficiency End-Diastolic Velocity (AR Trace) Aortic Valve Peak Velocity (AV Vmax) Aortic Valve Peak Velocity at Point E (AV Vmax) Aorta Proximal Coarctation (Coarc Pre-Duct) Aorta Distal Coarctation (Coarc Post-Duct) Aortic Valve Insufficiency Pressure Half Time (AR PHT) Aortic Valve Flow Acceleration (AV Trace) Aortic Valve Pressure Half Time (AV Trace) Aortic Valve Acceleration Time (AV Acc Ti me) Aortic Valve Deceleration TIme (AV Trace) Aortic Valve Ejection Time (AVET) Aortic Valve Acceleration to Ejection Time Ratio (AV Acc Time, AVET) Aortic Valve Area according to PHT

• Left Ventricle Left Ventricle Outflow Tract Peak

Pressure Gradient (VLOT Vmax) Left Ventricle Outflow Tract Peak Velocity (LVOT Vmax) Left Ventricle Outflow Tract Mean Pressure Gradient (LVOT Trace) Left Ventricle Outflow Tract Mean Velocity (LVOT Trace) Left Ventricle Outflow Tract Mean Square Root Velocity (LVOT Trace) Left Ventricle Outflow Tract Velocity Time Integral (LVOT Trace) Left Ventricle Ejection Time (LVET) Cardiac Output by Aortic Flow (AVA Pl ani met ry, AV Trace) Stroke Volume Index by Aortic Flow (AVA Planimetry, AV Trace)

• Mitral Valve Mitral Valve Regurgitant Flow Acceleration (MR Trace) Mitral Valve Regurgitant Mean Velocity (MR Trace) Mitral Regurgitant Mean Square Root Velocity (MR Trace) Mitral Regurgitant Mean Pressure Gradient (MR Trace) Mitral Regurgitant Velocity Time Integral (MR Trace) Mitral Valve Mean Velocity (MR Trace) Mitral Valve Mean Square Root Velocity (MR Trace) Mitral Valve Velocity Time Integral (MR Trace) Mitral Valve Mean Pressure Gradient (MR Trace) Mitral Regurgitant Peak Pressure Gradient (MR Vmax) Mitral Valve Peak Pressure Gradient (MR Vmax) Mitral Regurgitant Peak Velocity (MR Vmax) Mitral Valve Peak Velocity (MR Vmax) Mitral Valve Velocity Peak A (MV A Velocity) Mitral Valve Velocity Peak E (MV E Velocity) Mitral Valve Area according to PHT (MV PHT) Mitral Valve Flow Deceleration (MV Trace) Mitral Valve Pressure Half Time (PV PHT) Mitral Valve Flow Acceleration (MV Trace) Mitral Valve E-Peak to A-Peak Ratio (A-

C and D-E) (MV E/ARatio) Mitral Valve Acceleration Time (MV Acc Time) Mitral Valve Deceleration Time (MV Dec Time) Mitral Valve Ejection Time ((MV Trace) Mitral Valve A-Wave Duration (MV A Dur) Mitral Valve Time to Peak (MV Trace) Mitral Valve Acceleration Time/Deceleration Time Ratio (MVAcc/Dec Time) Stroke Volume Index by Mitral Flow (MVA Planimetry, MVTrace) Mitral Valve Area from Continuity Equation (MVAPlanimetry, LVOT Vmax, MV Vmax)

• Pulmonic Valve Pulmonic Insufficiency Peak Pressure Gradient (PR Vmax) Pulmonic Insufficiency End-Diastolic Pressure Gradient (PRTrace) Pulmonic Valve Peak Pressure Gradient (PV Vmax) Pulmonic End-Diastolic Pressure Gradient (PR Trace) Pulmonic Insufficiency Peak Velocity (PR Vmax) Pulmonic Insufficiency End-Diastolic Velocity (Prend Vmax) Pulmonic Valve Peak Velocity (PV Vmax) Pulmonic End-Diastolic Velocity (PV Trace) Pulmonary Artery Diastolic Pressure (PV Trace) Pulmonic Insufficiency Mean Pressure Gradient (PR Trace) Pulmonic Valve Mean Pressure Gradient (PV Trace) Pulmonic Insufficiency Mean Velocity (PR Trace) Pulmonic Insufficiency Mean Square Root Velocity(PR Trace) Pulmonic Insufficiency Velocity Time Integral (PR Trace) Pulmonic Valve Mean Velocity (PV Trace) Pulmonic Valve Mean Square Root Velocity (PV Trace) Pulmonic Valve Velocity Time Integral (PV Trace) Pulmonic Insufficiency Pressure Half Time (PR PHT)

LOGIQ P6 Product Data Sheet Page 10

Page 11: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

Pulmonic Valve Flow Acceleration (PV Acc Time) Pulmonic Valve Acceleration Time (PV Acc Time) Pulmonic Valve Ejection Time (PVET) Pulmonic Valve Pre-Ejection Period (PVPEP) QRS complex to end of envelope (Q-to-PV close) Pulmonic Valve Acceleration to Ejection TIme Ratio (PV Acc Time, PVET) Pulmonic Valve Pre-Ejection to Ejection Time Ratio (PVPEP, PVET)

• Right Ventricle Right Ventricle Outflow Tract Peak Pressure Gradient (RVOT Vmax) Right Ventricle Systolic Pressure (RVOT Vmax) Right Ventricle Outflow Tract Peak Velocity (RVOT Vmax) Right Ventricle Diastolic Pressure (RVOT Trace) Right Ventricle Outflow Tract Velocity Time Integral (RVOTTrace) Right Ventricle Ejection Time (RV Trace) Stroke Volume by Pulmonic Flow (RVOTPlanimetry, RVOTTrace) Right Ventricle Stroke Volume Index by Pulmonic Flow (RVOT Planimetry, RVOT Trace)

• System Pulmonary Artery Peak Velocity (PV Vmax) Pulmonary Vein Velocity Peak A (reverse) (P Vein A) Pulmonary Vein Peak Velocity (P Vein D, P Vein S) Systemic Vein Peak Velocity (PDA Diastolic, PDA Systolic) Ventricular Septal Defect Peak Velocity (VSD Vmax) Atrial Septal Defect (ASD Diastolic, ASD Systolic) Pulmonary Artery Velocity Time Integral (PV Trace) Systemic Vein Velocity Time Integral (PDA Trace) Pulmonary Vein A-Wave Duration (P Vein A Dur) IsoVolumetric Relaxation Time (IVRT) IsoVolumetric Contraction Time (IVCT) Pulmonary Vein S/D Ratio (P Vein D, P Vein S) Ventricular Septal Defect Peak

Pressure Gradient (VSD Vmax) Proximal Isovelocity Surface Area: Regurgitant Volume Flow (AR Trace) Pulmonic-to-Systemic Flow Ratio

(Qp/Qs) Proximal Isovelocity Surface Area: Aliased Velocity (AR Vmax) • Tricuspid Valve

• Mitral Valve Tricuspid Regurgitant Peak Pressure Gradient (TR Vmax) Proximal Isovelocity Surface Area:

Regurgitant Orifice Area (MR Radius) Tricuspid Valve Peak Pressure Gradient (TV Vmax) Proximal Isovelocity Surface Area:

Radius of Aliased Point (MR Radius) Tricuspid Regurgitant Peak Velocity (TR Vmax) Proximal Isovelocity Surface Area:

Regurgitant Flow (MR Trace) Tricuspid Valve Peak Velocity (TV Vmax) Tricuspid Valve Velocity Peak A (TV A Velocity)

Proximal Isovelocity Surface Area: Regurgitant Volume Flow (MR Trace)

Tricuspid Valve Velocity Peak E (TV E Velocity)

Proximal Isovelocity Surface Area: Aliased Velocity (MR Vmax)

Tricuspid Regurgitant Mean Pressure Gradient (TR Trace)

Combination Mode Measurements • Aortic Valve Tricuspid Valve Mean Pressure

Gradient (TV Trace) Aortic Valve Area (Ao Root Diam, LVOT Vmax, AV Vmax) Tricuspid Regurgitant Mean Velocity

(TR Trace) Aortic Valve Area by Continuity Equation by Peak Velocity (Ao Root Diam, LVOT Vmax, AV Vmax)

Tricuspid Regurgitant Mean Square Root Velocity (TR Trace) Tricuspid Regurgitant Velocity Time Integral (TR Trace)

Stroke Volume by Aortic Flow (AVA Pl ani met ry, AV Trace)

Tricuspid Valve Mean Velocity (TV Trace)

Cardiac Output by Aortic Flow (AVA Planimetry, AV Trace, HR)

Tricuspid Valve Mean Square Root Velocity (TV Trace)

Aortic Valve Area by Continuity Equation VTI (Ao Root Diam, LVOT Vmax, AV Trace) Tricuspid Valve Velocity Time Integral

(TV Trace) • Left Ventricle Tricuspid Valve Time to Peak (TV Acc/Dec Time)

Cardiac Output, Teichholz/Cubic (LVIDd, LVI Ds, HR)

Tricuspid Valve Ejection Time (TV Acc/Dec Time)

Cardiac Output Two Chamber, Single Plane, Area-Length/ Method of Disk(Simpson) (LVAd, LVAs, HR) Tricuspid Valve A-Wave Duration (TV A

Dur) Cardiac Output Four Chamber, Single Plane, Area-Length/ Method of Disk(Simpson) (LVAd, LVAs, HR)

QRS complex to end of envelope (Q-to-TV close) Tricuspid Valve Pressure Half Time (TV PHT)

Ejection Fraction Two Chamber, Single Plane, Area-Length/ Method of Disk(Simpson) (LVAd, LVAs) Stroke Volume by Tricuspid Flow (TV

Planimetry, TV Trace) Ejection Fraction Four Chamber, Single Plane, Area-Length/ Method of Disk(Simpson) (LVAd, LVAs)

Tricuspid Valve E-Peak to A-Peak Ratio (TV E/A Velocity)

Left Ventricle Stroke Volume, Single Plane, Two Chamber/Four Chamber, Area-Length (LVAd, LVAs)

Color Flow Mode Measurements • Aortic Valve

Left Ventricle Stroke Volume, Single Plane, Two Chamber/Four Chamber, Method of Disk(Simpson) (LVIDd, LVIDs, LVAd, LVAs)

Proximal Isovelocity Surface Area: Regurgitant Orifice Area (AR Radius) Proximal Isovelocity Surface Area: Radius of Aliased Point (AR Radius)

Left Ventricle Volume, Two Chamber/Four Chamber, Area-Length

Proximal Isovelocity Surface Area: Regurgitant Flow (AR Trace)

LOGIQ P6 Product Data Sheet Page 11

Page 12: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

- Harmonic Frequency : 3.6, 3.8, 4.0, 4.2MHz

- B-mode Imaging Frequency : 6.0, 8.0, 10.0 MHz

(LVAd, LVAs) Ejection Fraction, Bi-Plane, Method of Disk (LVAd, LVAs, 2CH, 4CH) - Doppler Frequency : 2.5, 3.3 MHz - Harmonic Frequency : 8.0, 10.0 MHz

- Biopsy Guide Available : Single Angle, Reusable

- Doppler Frequency : 4.0, 5.0 MHz Left Ventricle Stroke Volume, Bi-Plane, Method of Disk (LVAd, LVAs, 2CH, 4CH)

- Biopsy Guide Available : Single Angle, Disposable and Reusable

Left Ventricle Volume, Bi-Plane, Method of Disk (LVAd, LVAs, 2CH, 4CH)

• 4C Wide Band Convex Probe - Applications: Abdomen, OB Gyn,

Urology, Vascular • 8C Wide Band Microconvex Probe

- Applications : Neonatal, Pediatrics Left Ventricle Stroke Index, Single Plane, Two Chamber/Four Chamber, Area-Length (LVSd, LVSs, and BSA)

- Probe Band Width : 1.4 – 5.0 MHz - Probe Band Width : 4 – 11 MHz - Number of Element: 128 - Number of Element : 128 - Convex Radius : 60 mmR - Convex Radius : 11 mmR

Left Ventricle Volume, Single Plane, Two Chamber/Four Chamber, Method of Disk (LVAd, LVAs)

- FOV (Max) : 58° - FOV (Max) : 133° - Physical Foot Print : 60 x 18 mm - Physical Foot Print : 26 x 10 mm - B-mode Imaging Frequency : 2.0, 3.0,

4.0, 5.0 MHz - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz Left Ventricle Volume, Apical View, Long Axis, Method of Disk (LVAd, LVAs) - Harmonic Frequency : 4.0, 5.0, 5.2, 5.5

MHz - Harmonic Frequency : 8.0, 10.0 MHz - Doppler Frequency : 4.0, 5.0 MHz Stroke Volume by Aortic Flow (AVA

Planimetry, AV Trace) - Doppler Frequency : 2.5, 3.3 MHz - Biopsy Guide Available : None - Biopsy Guide Available : Multi Angle,

Reusable

• Mitral Valve • 3S Wide Band Phased Array Sector Probe Stroke Volume by Mitral Flow (MVA

Planimetry, MV Trace)

• 5CS Convex Probe - Applications : Cardiac, Trancranial, Abdomen Cardiac Output by Mitral Flow (MVA

Planimetry, MV Trace, HR) - Applications: Abdomen, OB Gyn,

Urology - Probe Band Width : 1.5 – 3.5 MHz - Probe Band Width : 2 – 6MHz - Number of Element : 64 • Pulmonic Valve - Number of Element : 128 - FOV (Max) : 90° Stroke Volume by Pulmonic Flow (PV

Planimetry, PV Trace) - Convex Radius : 60 mmR - Physical Foot Print : 19 x 12 mm - FOV (Max) : 58° - B-mode Imaging Frequency : 2.0, 2.5,

3.0 MHz Cardiac Output by Pulmonic Flow (PV Planimetry, PV Trace, HR)

- Physical Foot Print : 60 x 18 mm - B-mode Imaging Frequency : 2.0, 3.0,

4.0, 5.0 MHz - Harmonic Frequency : 2.8, 3.0, 3.2, 3.6

MHz • Tricuspid Valve Cardiac Output by Tricuspid Flow (TV Planimetry, TV Trace, HR)

- Harmonic Frequency : 4.0, 5.0, 5.2, 6.0 MHz

- Doppler Frequency : 1.7, 2.0, 2.2 MHz - CW Doppler Frequency : 2.0 MHz

- Doppler Frequency : 2.5, 3.3 MHz - Biopsy Guide Available : Multi Angle, Reusable Report Designer - Biopsy Guide Available : Multi Angle,

Reusable • On-board reporting package automates report writing • 5S Wide Band Phased Array Sector

Probe

• E8C Wide Band Microconvex Probe • Formats various exam results into a report suitable for printing to a windows printer or reviewing on a standard PC

- Applications : OB Gyn, Urology, Endocavity

- Applications : Cardiac, Trancranial, Abdomen

- Probe Band Width : 4 – 11 MHz - Probe Band Width : 2 – 5MHz - Number of Element : 128 - Number of Element : 96 • Exam results include patient info, exam

info, measurements, calculations, images, comments and diagnosis

- Convex Radius : 11 mmR - FOV (Max) : 90° - FOV (Max) : 133° - Physical Foot Print : 19 x 11 mm - Physical Foot Print : 26 x 10 mm - B-mode Imaging Frequency : 3.0 , 4.0,

5.0 MHz • Standard templates provided

- B-mode Imaging Frequency : 6.0, 8.0, 10.0 MHz

• Customizable templates - Harmonic Frequency : 4.0, 5.0 MHz - Harmonic Frequency : 8.0, 10.0 MHz - Doppler Frequency : 2.5, 3.3 MHz

Probes - Doppler Frequency : 4.0, 5.0 MHz - CW Doppler Frequency : 4.0 MHz - Biopsy Guide Available : Single Angle,

Disposable and Reusable Biopsy Guide Available: Multi Angle, Reusable

• 3CRF Wide Band Microconvex Probe

- Applications: Abdomen, Urology, Vascular • E8CS Wide Band Microconvex Probe • 7S Wide Band Phased Array Sector

Probe - Applications : OB Gyn, Urology, Endocavity

- Probe Band Width : 2.0 – 4 MHz - Applications: Cardiac, Pediatrics,

Abdomen - Number of Element: 128

- Probe Band Width : 4 – 11 MHz - Convex Radius : 20 mmR - Number of Element : 128 - Probe Band Width : 3 – 8 MHz - FOV (Max) : 80° - Convex Radius : 9 mmR - Number of Element : 96 - Physical Foot Print : 28 x 15 mm - FOV (Max) : 168° - FOV (Max) : 90° - B-mode Imaging Frequency : 2.0, 3.0,

3.5, 4.0 MHz - Physical Foot Print : 15 x 10 mm - Physical Foot Print : 9 x 7 mm

LOGIQ P6 Product Data Sheet Page 12

Page 13: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

- B-mode Imaging Frequency : 5.0, 6.0, 7.0 MHz

- Number of Element : 192

- Harmonic Frequency : 6.0, 7.0, 8.0, 8.5 MHz

- Doppler Frequency : 4.0, 5.0 MHz - CW Doppler Frequency : 4.0 MHz - Biopsy Guide Available : None

• 3Sp Wide Band Phased Array Sector Probe - Applications : Cardiac, Transcranial,

Abdomen - Probe Band Width : 1.5 – 5.5 MHz - Number of Element : 64 - FOV (Max) : 90° - Physical Foot Print : 16 x 14 mm - B-mode Imaging Frequency : 2.0, 3.0,

4.0, 5.0 MHz - Harmonic Frequency : 3.0, 3.5, 4.0, 5.0,

5.5 MHz - Doppler Frequency : 1.8, 2.0, 2.5, 3.3,

4.0 MHz - CW Doppler Frequency : 2.0 MHz Biopsy Guide Available: Multi Angle, Reusable

• 5Sp Wide Band Phased Array Sector Probe - Applications : Cardiac, Trancranial,

Abdomen - Probe Band Width : 2 – 8 MHz - Number of Element : 64 - FOV (Max) : 90° - Physical Foot Print : 10 x 10 mm - B-mode Imaging Frequency : 4.0, 5.0,

6.7, 8.0 MHz - Harmonic Frequency : 5.0, 6.0, 8.0,

10.0 MHz - Doppler Frequency : 3.0, 3.3 4.0, 5.0

MHz - CW Doppler Frequency : 2.5 MHz Biopsy Guide Available: Multi Angle, Reusable

• 8L Wide Band Linear Probe - Applications : Vascular, Small Parts - Probe Band Width : 4 – 11MHz - Number of Element : 128 - FOV (Max) : 38 mm - Physical Foot Print : 38 x 10 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 8.0, 10.0, MHz - Doppler Frequency : 5.0, 6.7 MHz - Steered Angle : 0, +/- 5, 10, 15, 20° - Biopsy Guide Available : Multi Angle,

Reusable

• 9L Wide Band Linear Probe - Applications: Vascular, Small Parts - Probe Band Width : 3 – 10MHz

- FOV (Max) : 44 mm - Physical Foot Print : 44 x 10mm - B-mode Imaging Frequency : 5.0, 7.0,

9.0 MHz - Harmonic Frequency : 8.0, 10.0 MHz - Doppler Frequency : 4.0, 5.0 MHz - Steered Angle : 0, +/- 5, 10, 15, 20° - Biopsy Guide Available : Multi Angle,

Reusable

• 11L Wide Band Linear Probe - Applications : Small Parts, Vascular,

Neonatal, Pediatrics - Probe Band Width : 5 – 13 MHz - Number of Element : 192 - FOV (Max) : 38.4 mm - Physical Foot Print : 38 x 10 mm - B-mode Imaging Frequency : 7.0, 10.0,

12.0 MHz - Harmonic Frequency : 10.0, 12.0, 13.0

MHz - Doppler Frequency : 5.0, 6.7 MHz - Steered Angle : 0, +/- 5, 10, 15, 20° - Biopsy Guide Available : Multi Angle,

Reusable

• i12L Intraoperative Wide Band Linear Probe - Applications : Intraoperative, Small

Parts, Vascular, Pediatrics - Probe Band Width : 5 – 12 MHz - Number of Element : 96 - FOV (Max) : 25 mm - Physical Foot Print : 25 x 10 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 10.0, 12.0MHz - Doppler Frequency : 5.0 MHz - Steered Angle : +/- 5, 10, 15, 20° - Biopsy Guide Available : None

• T739 Intraoperative Wide Band Linear Probe - Applications : Intraoperative, Small

Parts, Vascular, Pediatrics - Probe Band Width : 4 – 12 MHz - Number of Element: 192 - FOV (Max) : 39 mm - Physical Foot Print : 39 x 10 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 8.0, 10.0, 12.0

MHz - Doppler Frequency : 5.0, 6.7 MHz - Steered Angle : +/- 5, 10, 15, 20° - Biopsy Guide Available : None

• I739 Intraoperative Wide Band Linear Probe - Applications : Intraoperative, Small

Parts, Vascular, Pediatrics - Probe Band Width : 4 – 12 MHz - Number of Element: 192 - FOV (Max) : 39 mm - Physical Foot Print : 39 x 10 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 8.0, 10.0, 12.0

MHz - Doppler Frequency : 5.0, 6.7 MHz - Steered Angle : +/- 5, 10, 15, 20° Biopsy Guide Available : None

• BE9CS Wide Band Biplane Microconvex Probe - Applications: Urology, Endocavity - Probe Band Width : 4 – 11 MHz - Number of Element : 96 x 2 - Convex Radius : 9 mmR - FOV (Max) : 127° - Physical Foot Print : 20 x 10 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 8.0, 10.0 MHz - Doppler Frequency : 4.0, 5.0 MHz - Biopsy Guide Available : Single Angle

Reusable (stainless steel), Disposable • ERB Wide Band Biplane Probe

- Applications: Urology - Probe Band Width: 3- 11MHz ERB Linear 3 – 10 MHz ERB Convex: 4 - 9 MHz - Number of Element: 128 - FOV (Max) : ERB Linear: 51mm ERB Convex: 123° - Physical Foot Print: ERB Linear: 51 x 10 mm ERB Convex: 17 x 10.5 mm - B-mode Imaging Frequency: 6.0, 8.0,

10.0 MHz - Harmonic Frequency: 8.0, 10.0 MHz - Doppler Frequency: 5.0, 6.7 MHz - Biopsy Guide Available: Multi Angle,

Grid Reusable

• 4D3C-L Convex Volume Probe - Applications : Abdomen, OB Gyn - Probe Band Width : 2.0 – 5.0 MHz - Number of Element: 192 - Convex Radius : 39.1 mmR - Volume Sweep Radius: 19.8 mmR - FOV: 87° Volume 85° x 80° - Physical Foot Print : 60 x 13 mm - B-mode Imaging Frequency : 3.0, 4.0,

5.0 MHz - Harmonic Frequency : 4.0, 4.5, 4.8, 5.0

MHz - Doppler Frequency : 2.5, 3.3 MHz - Biopsy Guide Available : Single Angle,

LOGIQ P6 Product Data Sheet Page 13

Page 14: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

- Applications Transesophageal, Stomach

Reusable (stainless steel, plastic) • 4D5C-L Convex Volume Probe - Probe Band Width : 4.5 – 10.5 MHz

- Applications : Abdomen, OB Gyn - Number of Element: 128 - Probe Band Width : 3 – 7 MHz - Convex Radius: 8.5 mmR

- Number of Element: 192 - FOV (Max) : 125° - Convex Radius : 39.1 mmR - Physical Foot Print : 19 x 10 mm - Volume Sweep Radius: 19.8 mmR - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - FOV: 87° Volume 85° x 80° - Physical Foot Print : 60 x 13 mm - Harmonic Frequency : 8.0, 10.0 MHz - B-mode Imaging Frequency : 4.0, 5.0,

6.0 MHz - Doppler Frequency : 5.0, 6.7 MHz

- Biopsy Guide Available: None - Harmonic Frequency : 5.0, 6.0, 6.5,7.0

MHz • only available in Europe

- Doppler Frequency : 2.5, 3.3 MHz - Biopsy Guide Available : Single Angle

• 4D8C Micro Convex Volume Probe - Applications : Neonatal, Pediatrics - Probe Band Width : 4 – 11 MHz

- Number of Element: 192 - Convex Radius : 14.0 mmR - Volume Sweep Radius: 80 mm - FOV: 120° Volume 37.4 mm x 29°

- Physical Foot Print : 30 x 50 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz - Harmonic Frequency : 8.0, 10.0, 11.0

MHz

- Doppler Frequency : 4.0, 5.0 MHz

- Biopsy Guide Available : Single Angle Reusable (stainless steel, plastic)

• 4DE7C Convex Volume Probe

Inputs and Outputs - Applications : OB Gyn, Urology - Probe Band Width : 4 – 11 MHz Safety Conformance - Number of Element: 192 • Video In - Convex Radius: 10.1 mmR

- S-Video The LOGIQ P6 / P6 PRO are: - Volume Sweep Radius: 11.6 mmR - Composite Color - FOV: 133° Volume 146° x 90° • Listed to UL 2601-1 by a Nationally

Recognized Test Lab • Video Out - Physical Foot Print : 27 x 6 mm - B-mode Imaging Frequency : 6.0, 8.0,

10.0 MHz • Certified to CSA 22.2, 60601.1 by an

SCC accredited Test Lab - S-Video - Analog VGA

- Harmonic Frequency : 8.0, 10.0, 11.0 MHz

• CE Marked to Council Directive 93/42/EEC on Medical Devices

- Composite Color • Audio Stereo In - Doppler Frequency : 4.0, 5.0 MHz • Conforms to the following standards

for safety: • Audio Stereo Out - Biopsy Guide Available : Single Angle, Reusable (stainless steel) • External Microphone In - EN 60601-1 Electrical medical

equipment • Connectors • P2D Non-imaging Single CW Doppler

Pencil Probe - EN 60601-1-1 Electrical medical

equipment - Footswitch - USB for BW printer

- Applications : Cardiac - EN 60601-1-2 Electromagnetic compatibility

- USB for Color Printer - Frequency: 2.0 MHz - USB for remote control - EN 60601-1-4 Programmable medical

systems

- USB for DMC • P6D Non-imaging Single CW Doppler Pencil Probe - Additional USB (2) - EN 60601-1-6 Usability

- Ethernet - IEC 61157 Declaration of acoustic output

- Applications : Cardiac, Vascular, Pediatric - Power for Peripherals (3)

- EN 60601-2-37 Particular requirements for the safety of ultrasonic medical diagnostic and

- Frequency: 5.0 MHz

• UG7C Gastro Probe – Europe Only

LOGIQ P6 Product Data Sheet Page 14

Page 15: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are

monitoring equipment GE, GE Monogram and LOGIQ®, CrossXBeam , TruScan , LOGIQView and Inte are trademarks of General Electric Company.

- ISO 10993 Biological evaluation of medical devices

- NEMA UD3 Acoustic output display (MI, TIS, TIB, TIC)

- EMC Emissions Group 1 Class B device requirements as per Sub clause 4.2 of CISPR 11

GE LOGIQ P6 / P6 PRO are designed

for compatibility with commercially available ultrasound contrast agents. Because the availability of these agents is subject to government regulation and approval, product features intended for use with these agents may not be commercially marketed nor made available before the contrast agent is cleared for use. Contrast related product features are enabled only on systems for delivery to an authorized country or region of use. GE Healthcare makes no claims concerning the safety or effectiveness of contrast agents.

© 2008 General Electric Company - All rights reserved.

Not all features or specifications described in this document may available in all probes and/or modes. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product at any time without notice or obligation. Contact GE Representative for the most current information.

GE Healthcare. - America: 888-202-5528 P.O Box 414, Milwaukee , Wisconsin 53201 USA GE Healthcare , GE Asia Technology Park 3rd Floor, Building 1,1 Hua Tuo Road , Shanghai – 201203 Tel : +86 21 38774000 GE Ultraschall Deutschland GmbH & Co KG Beethovenstr. 239, D-42655 Solingen Tel.: (+49) 212-2802-0 Fax: (+49) 212-2802-28 Internet : www.gehealthcare.com GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC a General Electric company doing business as GE Healthcare

LOGIQ P6 Product Data Sheet Page 15

Page 16: LOGIQ P6 Pro - scilvet-es.com · The LOGIQ P6 PRO is a high end , ... • 8 TGC Pods, with Re-mapping ... User Manual and Service Manual are