Loca Por Las Compras 01- LOCA POR LAS COMPRAS- Sophie Kinsella
LOCA/LOFA Analyses for LiPb/FS System
description
Transcript of LOCA/LOFA Analyses for LiPb/FS System
![Page 1: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/1.jpg)
1
LOCA/LOFA Analyses for LiPb/FS System
Carl Martin, Jake Blanchard
Fusion Technology InstituteUniversity of Wisconsin - Madison
ARIES-CS Project MeetingNovember 4-5, 2004
![Page 2: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/2.jpg)
2
LOCA/LOFA Analysis Update
1. Description of the thermal models, boundary conditions, and assumptions used for the LOCA/LOFA analyses.
2. Update of results presented previously to include plasma / nuclear heating for 3 seconds after loss of coolant.
3. LOCA/LOFA analysis with new Li/Pb afterheat data.
4. Modeling in progress to include support structure.
![Page 3: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/3.jpg)
3
LiPb/FS/He Radial Build(Water Cooled Internal VV)
SOL
Vac
uum
Ves
sel
FS S
hiel
d
Ga p
Thickness(cm)
FW
Gap
+ T
h. In
sula
tor
Win
ding
Pac
k
Plas
ma
4.8 2 ≥ 231 312.228
≥ 149 cm| |C
oil C
ase
& In
sula
tor
Bla
nket
(LiP
b/FS
/He)
47
Bac
k W
all
9 1G
ap
Ext
erna
l Str
uctu
re
18
• These LOCA/LOFA analyses assume perfect insulation between the vacuum vessel ant the coil case, i.e. no heat loss.
• Also, no support structure in gaps included.
![Page 4: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/4.jpg)
4
ANSYS FE Model and Boundary Conditions for Thermal Analyses
Blanket Shield Vacuum Vessel
First WallTinit = 500 C
LiPBTinit = 625 C
Back WallTinit = 450 C
ShieldTinit = 450 C
Vacuum VesselTinit = 100 C
Gap
Gap
Ra d
ius
= 2 .
0 m
Ferritic Steel Boronated Ferritic Steel LiPb
H20
H20
H20
• Adiabatic boundary at back of vacuum vessel• Model is axisymmetric about plasma centerline and symmetric on sides• Emissivity of 0.3 assumed across vacuum gaps and vacated cooling channels• All analyses assume there is no helium in channels
![Page 5: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/5.jpg)
5
Analyses without LiPb in Blanket Including Surface and Nuclear Heating
Blanket Shield Vacuum Vessel
First WallTinit = 500 C
Back WallTinit = 450 C
ShieldTinit = 450 C
Vacuum VesselTinit = 100 C
Gap
Gap
Ra d
ius
= 2 .
0 m
SiC liner
• Surface and nuclear heating continues for three seconds after loss of coolant• First case assumes loss of all coolants – complete LOCA
![Page 6: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/6.jpg)
6
Complete LOCA Thermal Response
Long Term Response(10 Days)
Short Term Effect of Surface Heating(600 sec.)
• Without coolant or heat loss, temperature continues to rise.• Surface and nuclear heating have little long term effect. Long term
temperature rise increases by 0.2 C. First peak temperature increases by 2.6 C.
First peak (3.6 hr) Temperature spikes 100 C at 1st wall due to surface heating at 3 sec.
![Page 7: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/7.jpg)
7
LOCA in Blanket and ShieldLOFA in Vacuum Vessel
SiC liner
Blanket Shield Vacuum Vessel
First WallTinit = 500 C
Back WallTinit = 450 C
ShieldTinit = 450 C
Vacuum VesselTinit = 100 C
Gap
Gap
Ra d
ius
= 2 .
0 m
• Natural convection to water in vacuum vessel assumed• Heat transfer coefficient of 500 W/m2-C to 100 C water • Surface and nuclear heating continues for three seconds
wa t
er
wa t
er
wa t
er
![Page 8: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/8.jpg)
8
Thermal Response for LOCA in Blanket/Shield and LOFA in Vacuum Vessel
• Peak temperature of 730 C occurs 3.6 hr after loss off coolant / flow and continues to drop with time.
• Addition of surface and nuclear heating increases peak by 2.5 C.• Results not particularly sensitive to VV convection assumptions.
![Page 9: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/9.jpg)
9
Blanket Shield Vacuum Vessel
First WallTinit = 500 C
LiPBTinit = 625 C
Back WallTinit = 450 C
ShieldTinit = 450 C
Vacuum VesselTinit = 100 C
Gap
Gap
Ra d
ius
= 2 .
0 m
Ferritic Steel Boronated Ferritic Steel LiPb
H20
H20
H20
• Updated estimates of LiPb afterheat included. Heating levels much lower than previously assumed.
• Nuclear heating assumed for three seconds after loss of flow.• Analysis repeating with (LOFA) and without water (LOCA) in vacuum vessel.
Analyses Including the Static Presence of LiPb in the Blanket
![Page 10: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/10.jpg)
10
Afterheat in Blanket Materials
0
25
50
75
100
125
150
175
200
0 4 8 12 16 20 24
Time (hr)
Hea
ting
(kW
/m3 )
LiPb in Blanket
Steel in Blanket
• LiPb afterheat scaled from ARIES-AT data.• Previously presented results (Sept.) had used heating for steel.
![Page 11: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/11.jpg)
11
Thermal Results LOFA for LiPb and LOCA for He and Water
• Resulting temperatures slightly lower than complete LOCA.
![Page 12: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/12.jpg)
12
• Maximum temperature 17.8 C less than the case without LiPb.
Thermal Results LOFA for LiPb and Water and LOCA for He
![Page 13: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/13.jpg)
13
Support Structure Modeling• Model to include heat loss through supporting leg and also structures
in vacuum gaps.• Potential to model noncircular cross-sections.• Heat transfer from vacuum vessel to coils may also be included.
Shield
Blanket
Vacuum Vessel
Supporting Leg
![Page 14: LOCA/LOFA Analyses for LiPb/FS System](https://reader036.fdocuments.net/reader036/viewer/2022062521/56814c26550346895db92c87/html5/thumbnails/14.jpg)
14
Summary
• Peak temperatures are below 730 C for cases with LOFA in the vacuum vessel. Results not particularly sensitive to VV convection assumptions.
• Without heat removal (LOCA in VV), the temperatures continue to rise over time.
• The addition of surface and nuclear heating for three seconds after LOCA increased the peak temperature by 2.5 C.
• Models are being developed to include support structure and heat loss from vacuum vessel.