Plate Mounting Minimise press downtime Latest developments in mounting.
LOAD CELL - اتوماسیون صنعتیmapsa-eng.com/file/Loadcell.pdf · Load cell Connection...
Transcript of LOAD CELL - اتوماسیون صنعتیmapsa-eng.com/file/Loadcell.pdf · Load cell Connection...
LOAD CELLLoad Cell Selection Guide
www.sewhacnm.co.kr - 25 -25
LOAD CELL
MODEL AB LLB SB SS SL SC SM ST SB SBW
Capacity 120 130 140 200 210 300 410 520 530 600 601 602 603 800 900 910 920
1kgf
2kgf
3kgf
5kgf
10kgf
15kgf
20kgf
30kgf
50kgf
60kgf
100kgf
150kgf
200kgf
250kgf
300kgf
500kgf
1tf
2tf
3tf
5tf
10tf
15tf
20tf
25tf
30tf
50tf
70tf
100tf
200tf
500tf
800tf
NO
MEN
CLA
TUR
E C
OD
ESE
LEC
TIO
N G
UID
E
LOAD DIRECTGRADE
UNITS
MATERIAL
A : AluminumS : SteelL : Stainless Steel
B : Beam-TypeS : S-TypeL : Low-ProfileC : CanisterM : MiniatureH : HollowO : Option
G : GeneralL : LowH : HighS : Special
kgftf1bfN
T : TensionC : CompressionU : Universal
ModelNumber Capacity
Single Point Shear/Bending
Low CanisterType Miniature Type Tension
Type Truck / Tank Scale TypeS-Beam
LBB200 Explosion Proof Version, Ex nA IIB-T4LBB200 Explosion Proof Version, Ex nA IIB-T4Bending Beam Load Cell 20kgf ~ 500kgf
www.sewhacnm.co.kr- 26 -26
LOAD CELLPR
OD
UC
TSPE
CIFIC
ATION
DIM
ENS
ION
(R.C) kgf / tf 20, 50, 100, 200, 500kgf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.2Combined Error % 0.03Repeatability % 0.01Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.028Output Value % / 10°C 0.015
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 50Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operaing Temp Range °C -20 ~ +70
Feature
- All Stainless Steel Construction- Protection Class IP67- Braided Shield 4-Wire Round Cable- Explosion Proof function Addable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
Cable Length 3m42
82120
10 18
3-Ø8.2 Thru
NEWProduct
2012
AB120/130/140Single Point Load Cell 3kgf ~ 1tf
www.sewhacnm.co.kr - 27 -27
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) kgf / tfAB120 AB130 AB140
3, 5, 10, 15, 20, 30, 50kgf 30, 50, 60, 100, 150, 300kgf 500kgf, 1tfRated Output (R.O) mV/V 2.0 ± 10%Zero Balance mV/V 0 ± 0.1Combined Error % 0.03Repeatability % 0.01Creep (30min) % 0.03Temperature Effect on
Zero Value % / °C 0.03Output Value % / °C 0.02
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -30 ~ +80Physical Weight kg 0.3 1.5 2.5
Feature
- Low Cost- Off Center Compensated- Protection Class IP65- Material : Aluminium- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
SB210Shear Beam Load Cell 150kgf ~ 10tf
www.sewhacnm.co.kr- 28 -28
LOAD CELLPR
OD
UC
TSPE
CIFIC
ATION
DIM
ENS
ION
Rated Capacity (R.C) kgf / tf 150, 200, 250, 300, 500kgf, 1, 2, 3, 5, 10tf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.02Combined Error % 0.03Repeatability % 0.01Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.02
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -30 ~ +80
Model Capacity A B C D E F ØG ØH I J K L WeightSB210 - 150kgf 150kgf
25.4 76.2 130 31.8 32 15.8 13.5 13.5 16 M12xP1.75 57 58 1.0kg
SB210 - 200kgf 200kgfSB210 - 250kgf 250kgfSB210 - 300kgf 300kgfSB210 - 500kgf 500kgfSB210 - 1tf 1tfSB210 - 2tf 2tfSB210 - 3tf 3tfSB210 - 5tf 5tf 38.1 95.3 171.5 38 38 19 20 20 19 M18xP1.5 76 44.5 2.0kgSB210 - 10tf 10tf 50.8 120.4 222 50.8 50.8 25.4 26.2 26.2 25.4 M24xP2.0 100 57.2 4.3kg
Feature
- Low Cost- Compact Design- Compression Type- Protection Class IP66- Nickel Plated Steel- Braided Shield 4-Wire Round Cable
Option
- Stainless Steel - LB210 ( )
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
SS300SS - Beam Load Cell 50kgf ~ 10tf
www.sewhacnm.co.kr - 29 -
LOAD CELL
Rated Capacity (R.C) kgf / tf 50, 100, 150, 200, 250, 300, 500kgf, 1, 2, 3, 5, 10tf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.02Combined Error % 0.03Repeatability % 0.01Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.02
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -30 ~ +80
Model Capacity ØA B C D E ØF G H WeightSS300 ~ 50kgf 50kgf
80 74
76
19
M12xP1.75
- - - 1.0kg
SS300 ~ 150kgf 150kgfSS300 ~ 200kgf 200kgf
26
SS300 ~ 250kgf 250kgf 80
74SS300 ~ 300kgf 300kgfSS300 ~ 500kgf 500kgf
80SS300 - 1tf 1tf M18xP1.5SS300 - 2tf 2tfSS300 - 3tf 3tf 115 90 110 30 M20xP1.5 1.8kgSS300 - 5tf 5tf 125 123 120 36 M24xP2.0 13 42 18 2.7kgSS300 - 10tf 10tf 175 172 168 50 M30xP2.0 21 64 29 7.5kg
Feature
- Low Cost- Compact Design- Compression Type- Protection Class IP66- Nickel Plated Steel- Braided Shield 4-Wire Round Cable
Option
- Stainless Steel - LS300 ( )
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPE
CIF
ICAT
ION
DIM
ENS
ION
SC530Canister Type Compression Load Cell 20 ~ 800tf
www.sewhacnm.co.kr- 30 -30
LOAD CELL
Rated Capacity (R.C) tf 20, 30, 50, 100, 200, 500, 800tf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.03Combined Error % 0.15Repeatability % 0.10Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 350 ± 3.5Output 350 ± 3.5Insulation >2,000@ DC 50V
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80
Feature
- Hermetically Sealed High Accuracy Grade- Robust Design- Compression Type- Fully Environmental Protection IP67- Paint Finished Steel- Braided Shield 4-Wire Round Cable with PVC - Jacket
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPEC
IFICATIO
ND
IMEN
SIO
N
Model Capacity ØA B ØC D E F G H I ØJ ØK L M N O P Q WeightSC530 - 20tf 20tf 118 145 36 10 104 150 M12xP1.75 80 150 200 150 30 200 150 15 14 190 7.5kgSC530 - 30tf 30tf 118 145 36 10 104 150 M12xP1.75 80 150 200 150 30 200 150 15 14 190 7.5kgSC530 - 50tf 50tf 118 160 50 20 104 170 M12xP1.75 80 200 220 160 40 220 160 20 19 220 10.0kgSC530 - 100tf 100tf 158 190 70 20 144 190 M16xP2.0 100 200 260 200 60 260 200 30 23 280 13.0kgSC530 - 200tf 200tf 214 230 95 30 188 249 M16xP2.0 130 300 280 200 80 280 200 40 27 350 13.0kgSC530 - 500tf 500tf 214 280 140 30 188 249 M16xP2.0 130 800SC530 - 800tf 800tf 260 360 180 30 228 295 M20xP2.5 160 720Special Order
SL410 Explosion Proof Version, Ex nA IIB-T4SL410 Explosion Proof Version, Ex nA IIB-T4
www.sewhacnm.co.kr - 31 -
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) tf 1, 2, 3, 5, 10, 20, 30, 50, 100, 200tf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.02Accuracy Class A BCombined Error % 0.02 0.05Repeatability % 0.01 0.02Creep (30min) % 0.03 0.03Temperature Effect on
Zero Value % / 10°C 0.03 0.03Output Value % / 10°C 0.03 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 350 ± 3.5Output 350 ± 3.5Insulation >2,000@ DC 50V
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80
Capacity ØA B C D E F G ØH ØI J WeightSL410 - 1tf 1tf
110 46 4
1 38 68
139.5 8-Ø6.6 97.2 M16xP2.01.8kg
SL410 - 2tf 2tf 2.3kgSL410 - 3tf 3tf 2.8kgSL410 - 5tf 5tf 120 46 4 149.5 8-Ø9 103.2 M18xP1.5 3.2kgSL410 - 10tf 20tf 138 60 11 167.5 8-Ø11 117.6 M24xP2.0 5.1kgSL410 - 20/30tf 20/30tf 184 80 21 213.5 8-Ø14 157.6 M39xP2.0 12.0kgSL410 - 50tf 50tf 200 60 11 229.5 12-Ø14.3 170 M45xP3.0 15.0kgSL410 - 100tf 100tf 278 90 26 307.5 16-Ø16.3 229 M70xP3.0 28.0kgSL410 - 200tf 200tf 335 108 35 384.5 12-Ø26 298 M90xP3.0 37.0kg
Feature
- Hermetically Sealed- High Reliability Against Fatigue & Force- Fully Environmental Protection IP- Paint Finished Steel- Explosion Proof function Addable- Braided Shield 4-Wire Round Cable with PVC - Jacket
Option
- Stainless Steel - LL410 ( )
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
G
F
D
C
4-ØI thru
4-ØI thru
Flexible Rubber
5 m
4-ØI thru
4-ØI thru
Flexible Rubber
5 m
C
D
F
G
SL410 Compression/Ball Type SL410 Compression/Ball Type Pan Cake Load Cell 1tf ~ 100tf / 1tf ~30 tf
www.sewhacnm.co.kr- 32 -32
LOAD CELL
Capacity A B C D E F G H I1tf, 2tf, 3tf 105 59 130x130 105x105 23 210x130 185x105 23 12
5tf 107 61 130x130 105x105 23 210x130 185x105 23 1210tf 140 80 160x160 125x125 30 160x160 125x125 30 14
20tf, 30tf 175 115 200x200 150x150 30 200x200 160x160 30 1450tf 225 105 260x260 200x200 60 260x260 200x200 60 23100tf 275 155 360x360 280x280 30 360x360 280x280 30 27
A B C D E F G H I1tf, 2tf, 3tf 136 90
130x130 105x105
23 210x130 185x105 23 125tf 145 99 23 210x130 185x105 23 12
10tf 166 113 30 160x160 125x125 30 1420tf, 30tf 196 143 30 200x200 160x160 30 14
INSTALLATION AS COMPRESSION APPLICATION
Manual
Manual
Accessory Features
Accessory Features
INSTALLATION AS BALL TYPE APPLICATION
INS
TALLATIO
N A
S CO
MPR
ESSIO
N A
PPLIC
ATION
INS
TALLATIO
N A
S CO
MPR
ESSIO
N A
PPLIC
ATION
High Durability Appropriate for Tank and Hopper Applica-
High Durability Appropriate for Tank and Hopper Applica-
Load cell Connection with The Mounting Plate Fix The Mounting Plate on the Surface Check the level of The Mounting Plate Place the Loading Plate over the Load cell Check the value with a Display System.
Load cell Connection with The Mounting Plate Fix The Mounting Plate on the Surface Check the level of The Mounting Plate Place the Loading Plate over the Load cell Check the value with a Display System.
[Unite: mm]
[Unite: mm]
SC520Canister Load Cell 200kgf ~ 20tf
www.sewhacnm.co.kr - 33 -33
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) kgf / tf 200, 300, 500kgf, 1, 2, 3, 5, 10, 20tf
Rated Output (R.O) mV/V 3.0 ± 0.003Zero Balance mV/V 0 ± 0.02Accuracy Class A BCombined Error % 0.02 0.05Repeatability % 0.01 0.02Creep (30min) % 0.03 0.03Temperature Effect on
Zero Value % / 10°C 0.03 0.03Output Value % / 10°C 0.03 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 350 ± 3.5Output 350 ± 3.5Insulation >2,000@ DC 50V
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -30 ~ +80
Model Capacity A ØB C D E F G H WeightSC520 - 200kgf 200kgf
115 89 6 115 2 M12xP1.25 34 38 4.0kgSC520 - 300kgf 300kgfSC520 - 500kgf 500kgfSC520 - 1tf 1tfSC520 - 2tf 2tf
148 89 9 115 2 M24xP2.0 55 38 5.0kgSC520 - 3tf 3tfSC520 - 5tf 5tfSC520 - 10tf 10tf 215 127 12 152 2 M39xP2.0 75 38 8.0kgSC520 - 20tf 20tf 290 165 15 193 2 M50xP2.0 80 38 10.0kg
Feature
- Hermetically Sealed High Accuracy Grade- Robust Design- Compression / Tension Type- Fully Environmental Protection IP67- Paint Finished Steel- Braided Shield 4-Wire Round Cable with PVC - Jacket
Option
- Stainless Steel - LC520 ( )
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
SC520 Compression/Tension TypeSC520 Compression/Tension TypeCanister Load Cell 200kgf ~ 20tf
www.sewhacnm.co.kr- 34 -
LOAD CELL
Capacity A B C D E F G H I200kgf
153.7 123.7 100 77 15 100 77 15 8300kgf500kgf
1tf2tf
210.3 164.3 130 105 23 130 105 23 123tf5tf10tf 303 243 160 125 30 160 125 30 1420tf 375.5 315.5 200 150 30 200 150 30 14
Capacity A B C D E F G200kgf
255 ~ 260 221 ~ 216 34 16 12 12 15.4300kgf500kgf
1tf2tf
525 ~ 530 423 ~ 428 102 28 27 22 25.83tf5tf
10tf 680 ~ 685 545 ~ 550 135 40 38 39.0 45.020tf Demand Accessory
Installation as Compression Application
Installation as Tension Application
INS
TALLATIO
N A
S CO
MPR
ESSIO
N A
PPLIC
ATION
INS
TALLATIO
N A
S TEN
SION
AP
PLICATIO
NRod End (200kgf ~1tf: M12 x P1.25)Rod End (2tf ~5tf: M24 x P2.0)
SM600Miniature Load Cell 50kgf ~ 20 tf
www.sewhacnm.co.kr - 35 -35
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) kgf / tf 50, 100, 200, 500kgf, 1, 2, 5, 10, 20tf
Rated Output (R.O) mV/V 2.0 ± 0.005Zero Balance mV/V 0 ± 0.02Combined Error % 0.05Repeatability % 0.02Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -30 ~ +80
Model Capacity A B ØC ØD E F ØG H WeightSM600 - 50kgf 50kgf
25 21 59 10 68 M5xP0.8(dp7) 42 50 0.6kg
SM600 - 100kgf 100kgfSM600 - 200kgf 200kgfSM600 - 500kgf 500kgfSM600 - 1tf 1tfSM600 - 2tf 2tfSM600 - 5tf 5tf 40 35 98 20 115 M6xP1.0(dp8) 72 150 1.8kgSM600 - 10tf 10tf 45 40 98 20 115 M6xP1.0(dp8) 72 150 2.2kgSM600 - 20tf 20tf 50 45 118 20 135 M8xP1.25(dp10) 90 250 3.6kg
Feature
- Miniature Dimension- Compression Application- Application for Limited Space- Protection Class IP66- Nickel Plated Steel- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
SM601/602Miniature Load Cell 1kgf ~ 2tf
www.sewhacnm.co.kr- 36 -36
LOAD CELL
Rated Capacity (R.C) kgf / tfSM601 SM602
10, 30, 50, 100kgf, 1, 2tf 1, 5, 10, 30, 50, 100kgfRated Output (R.O) mV/V 1.0 ± 0.05 (1kgf, 5kgf) 2.0 ± 0.05Zero Balance mV/V 0 ± 0.02Combined Error % 0.15 0.1Repeatability % 0.1 0.05Creep (30min) % 0.05 0.05Temperature Effect on
Zero Value % / 10°C 0.01Output Value % / 10°C 0.02
ExcitationRecommended V 10Maximum V 15
ResistanceInput 410 ± 30Output 350 ± 10Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +70Physical Weight kg 0.3
Feature
- Miniature Dimension- Compression Application- Application for Limited Space- Protection Class IP66- Nikel Plated Steel- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPEC
IFICATIO
ND
IMEN
SIO
N
Model Capacity A B ØC D ESM601 - 10kgf 10kgf
14 1 4 20
12.5
SM601 - 30kgf 30kgfSM601 - 50kgf 50kgfSM601 - 100kgf 100kgfSM601 - 1tf 1tfSM601 - 2tf 2tfSM602 - 1kgf 1kgf
18 2.5 5 35
SM602 - 5kgf 5kgfSM602 - 10kgf 10kgfSM602 - 30kgf 30kgfSM602 - 50kgf 50kgfSM602 - 100kgf 100kgf
SM603Miniature Load Cell 1kgf ~ 2tf
www.sewhacnm.co.kr - 37 -37
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) kgf / tf 1, 5, 10, 20, 30, 50, 100, 200, 500kgf, 1, 2tf
Rated Output (R.O) mV/V 1 ± 0.05Zero Balance mV/V 0 ± 0.02Combined Error % 0.1Repeatability % 0.1Creep (30min) % 0.05Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 420 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80Physical Weight kg 1.5
Feature
- Miniature Dimension- Tension Type- Application for Limited Space- Protection Class IP67- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
(RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
ST800Tension Meter Load Cell 10tf ~ 70tf
www.sewhacnm.co.kr- 38 -38
LOAD CELL
Rated Capacity (R.C) kgf / tf 10, 20, 30, 50, 70tf
Rated Output (R.O) mV/V 1.0 ± 0.005Zero Balance mV/V 0 ± 0.02Combined Error % 0.05Repeatability % 0.05Creep (30min) % 0.05Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 400 ± 30Output 350 ± 3.5Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80
Feature
- Tension Type- Protection Class IP66- Nikel Plated Steel
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPEC
IFICATIO
ND
IMEN
SIO
N
Model Capacity A B C ØD ØE ØF W WeightST800 - 10tf 10tf 231 161 91 88 60 30 30 4.4kgST800 - 20tf 20tf 331 216 91 88 85 55 45 9.0kgST800 - 30tf 30tf 391 266 131 125 95 65 55 12.0kgST800 - 50tf 50tf 451 296 131 125 120 75 65 25.0kgST800 - 70tf 70tf 511 326 131 150 140 95 80 35.0kg
SB900Truck Weighing Load Cell 10tf ~ 25tf
www.sewhacnm.co.kr - 39 -
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) tf 10, 15tf 25tf
Rated Output (R.O) mV/V 2.0 ± 0.004Zero Balance mV/V 0 ± 0.03Combined Error % 0.03Repeatability % 0.02Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.015
ExcitationRecommended V 10Maximum V 15
ResistanceInput 800 ± 40Output 700 ± 7Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80Physical Weight kg 12.5 18.0
Feature
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
- Robust Design and Easy Installation- Strong Against Shock or Side Force- Protection Class IP67- Paint Finished Steel- Braided Shield 4-Wire Round Cable
SB910Truck Weighing Load Cell 10tf ~ 25tf
www.sewhacnm.co.kr- 40 -40
LOAD CELL
(R.C) tf 10tf 25tf
Rated Output (R.O) mV/V 3.0 ± 0.006Zero Balance mV/V 0 ± 0.03Combined Error % 0.03Repeatability % 0.02Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.015
ExcitationRecommended V 10Maximum V 15
ResistanceInput 800 ± 40Output 700 ± 7Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80Physical Weight kg 8.0 23.0
Feature
- Robust Design and Easy Installation- Strong Against Shock or Side Force- Nikel Plated Steel- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPEC
IFICATIO
ND
IMEN
SIO
N
SB920Truck and Tank Weight Load Cell 25tf
www.sewhacnm.co.kr - 41 -
LOAD CELLPR
OD
UC
TSP
EC
IFIC
ATIO
ND
IMEN
SIO
N
Rated Capacity (R.C) tf 25tf
Rated Output (R.O) mV/V 2.0 ± 0.004Zero Balance mV/V 0 ± 0.02Combined Error % 0.03Repeatability % 0.02Creep (30min) % 0.03Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.015
ExcitationRecommended V 10Maximum V 5
ResistanceInput 800 ± 40Output 700 ± 7Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80Physical Weight kg 21.0
Feature
- Robust Design and Easy Installation- Strong Against Shock or Side Force- Protection Class IP67- Suitable for Moisture Environment- Paint Finished Steel- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
SBWTruck Weighing Load Cell 20tf ~ 30tf
www.sewhacnm.co.kr- 42 -42
LOAD CELL
(R.C) tf 20, 25, 30tf
Rated Output (R.O) mV/V 2.0 ± 0.006Zero Balance mV/V 0 ± 0.03Combined Error % 0.02Repeatability % 0.01Creep (30min) % 0.017Temperature Effect on
Zero Value % / 10°C 0.03Output Value % / 10°C 0.03
ExcitationRecommended V 10Maximum V 15
ResistanceInput 800 ± 40Output 700 ± 7Insulation >2,000
Compensated Temp Range °C -10 ~ +40Operating Temp Range °C -20 ~ +80Physical Weight kg 12.0
Feature
- Robust Design and Easy Installation- Strong Against Shock or Side Force- Protection Class IP68- Suitable for Moisture Environment- Paint Finished Steel- Braided Shield 4-Wire Round Cable
CABLE COLOR CODE
EXC + (RED)
EXC + (WHITE)
SIG + (GREEN)
SIG + (BLUE, BLACK)
SHLD (YELLOW)
PRO
DU
CT
SPEC
IFICATIO
ND
IMEN
SIO
N
LOAD CELLLoad Cell Installation Guide
www.sewhacnm.co.kr - 43 -43
LOAD CELLFO
R C
OM
PR
ESSI
ON
FOR
TEN
SIO
N
LOAD CELL
www.sewhacnm.co.kr- 44 -
LOAD CELLTE
CH
INIC
AL D
EFINITIO
NS
OF TER
MIN
OLO
GY
(1) RATED CAPACITY (R.C)The maximum axial load that a load cell is designed to
(2) RATED OUTPUT (R.O)The algebraic difference between the outputs at on load
millivolts per volt at rated capacity.
(3) NON-LINEARITYThe maximum deviation of the calibra-
tion curve from a straight line between zero and rated load outputs, expressed as a percent of the rated output and measured on increasing load only.
A: Linear line drawn to obtain terminal linearly
(4) HYSTERESISThe maximum difference between out-
put readings for the same applied load one point obtained while decreasing from rated output. The points are taken on the dame continuous cycle. The deviation is expressed as a percent of rated output.
(5) REPEATABILITYThe ability of load cell to reproduce
output readings when the same load is applied to it consecutively, under the same conditions, and in the same direction. Repeatability is expressed as the maximum difference between output readings as a percent of rated output.
(6) ZERO BALANCEThe output signal of the load cell with rated excitation
and with on load applied, usually expressed in percent of rated output.
(7) TEMPERATURE RANGE, COMPENSATEDThe range of temperature over which the load cell is
compensated to maintain rated output and zero balance
(8) TEMPERATURE RANGE, SAFEThe range of temperature over which the load cell may
be safely operated up to full scale without causing failure
(9) TEMPERATURE EFFECT ON RATED OUTPUTThe change in rated output due to a change in ambi-
ent temperature. Usually expressed as +/- a percentage change in rated output per degree °C change in ambient
temperature, over the compensated temperature range.(10) TEMPERATURE EFFECT ON ZERO BALANCEThe change in zero balance due to a change in ambi-
ent temperature. Usually expressed as +/- a percentage change in the compensated temperature range.
(11) TERMINAL RESISTANCE, INPUTThe resistance of the load cell circuit measured at the excitation terminal. At standard temperature, with no-load applied. And with The output terminals open circulated.
(12) TERMINAL RESISTANCE OUTPUTThe resistance of the load cell circuit measured at the
output signal terminals, at standard temperature, with no-load applied, and with excitation terminals open cir-culated.
(13) INSULATION RESISTANCEThe DC resistance expressed in ohms measured be-
tween any electrical connector pin or lead wire and the load cell body or case. Normally measured at DC 50V.
(14) EXCITATIONThe voltage or current applied to the input terminals of
the load cell.
(15) SAFE OVERLOADThe maximum load in percent of rated capacity which
can be applied without causing a producing a structural failure.
(16) ULTIMATE OVERLOADThe maximum load in percent of rated capacity which
can be applied without producing a structural failure.
(17) CREEPThe change in load cell output occurring with time, while
under load, and with all environmental conditions and other variables remaining constant. Usually measured with rated load applied and expressed as a percent of
(18) ACCURACYStated as a limit tolerance which deafness the average
deviation between the actual output versus theoretical output. In practical load cell applications, the potential errors of nonlinearity, hysteresis, repeatability and tem-perature effects do not normally occur simultaneously, nor are they necessarily additive.Therefore, accuracy is calculated based upon the RMS value of potential errors, assuming a temperature band of ± 10 °C, full rated load applied, and proper set up and calibration.Potential errors of the read out, cross talk, or creep ef-Potential errors of the read out, cross talk, or creep efPotential errors of the read out, cross talk, or creep effects are not included.
TECHNICAL DEFINITIONS OF TERMINOLOGY