NVLAP LAB CODE 201011-0 Report No.: GZN140214-D Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 Address8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 14 LM-79-08 Test Report For RL/Apadana LLC (Brand Name: Apadana ) 3801 York Ave. South Minneapolis, MN 55410 Low-Bay/High-Bay Luminaires for Commercial & Industrial Buildings Model name(s): AP-HB-100W-LV Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Manager: Tommy Liang Date: May.19.2014 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Transcript of LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774...

Page 1: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 14

LM-79-08 Test Report

For

RL/Apadana LLC

(Brand Name: Apadana )

3801 York Ave. SouthMinneapolis, MN 55410

Low-Bay/High-Bay Luminaires for Commercial

& Industrial Buildings

Model name(s): AP-HB-100W-LV

Test & Report By: Review By:

Sean Zhuo Engineer: Sean Zhuo Manager: Tommy Liang

Date: May.19.2014

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

Page 2: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 14

U.S. Department of Energy

Lighting FactsTM

Uniform LM-79 Reporting Template

Laboratory Information:

Name of Test Laboratory Standard-Tech Co. Ltd

Date of Test Report May.19.2014

Test Report No. GZN140214-D

Laboratory Contact Name Tommy Liang

Product Information:

Organization Name RL/Apadana. Brand Name Apadana Model Number AP-HB-100W-LV

SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type)

Low-Bay/High-Bay Luminaires for

Commercial and Industrial Buildings

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

Electrical Measurements:

Integrating Sphere

Output

Goniophotometer

Output

Input Wattage -- 92.92 W

Input Current -- 0.7846 A

Input Voltage (ac) -- 120.0 V

Power Factor -- 0.9845

Off-State Power -- 0 W

Photometric Characteristics

Total Initial Lumen Output -- 7333.1 lm

Initial Lumen Efficacy -- 78.92 lm/w

Correlated color temperature / CCT 5247 -- K

Color rendering index / CRI 83.5 --

R9 Value 14 --

Duv -0.0005 --

Luminous Intensity Distribution

Center beam candlepower (if applicable)

-----

5779 cd

Beam angle (if applicable) 60.5 °

Zonal lumens in the 0°-60° zone 89.57 %

Zonal lumens in the 60°-90° zone 10.23 %

Zonal lumens in the 90°-120° zone 0.00 %

Zonal lumens in the 120°-180° zone 0.20 %

Page 3: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 14

Test Specifications:

Date of Receipt : May.15.2014

Date of Test : May.16.2014

Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous

Efficacy, Correlated Color Temperature, Color Rendering Index,

Chromaticity Coordinate, Electrical parameters

Reference Standard IES LM-79-2008 Electrical and Photometric Measurements of Solid-State

Lighting Products

ANSI C78.377-2008 Specifications for the Chromaticity of Solid State

Lighting Products

CIE 13.3-1995 Method of Measuring and Specifying Colour Rendering

Properties of Light Sources

CIE 15-2004 Technical Report Colorimetry

IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED)

Sources and Systems

Reference Work

Instruction

QD25

Test Methods

1. Photometric and Electrical measurements – Light Distribution Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 Volts AC, 60Hz. It was

stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2. Photometric and Electrical Measurements – Integrating Sphere Method:

Photometric parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 Volts AC, 60Hz. It

was stabilized before measurement was made. Chromaticity coordinates, correlated color temperature

and color rendering index were calculated from the spectral radiant flux measurements taken at least 5

nm intervals over the range of 380 to 780 nm.

Page 4: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 14

1. Product Information:

Brand Name RL/Apadana Model Number AP-HB-100W-LV

Luminaire Type Low-Bay/High-Bay Luminaires for

Commercial and Industrial Buildings

Rated Voltage / Frequency 100 ~ 277 Vac, 50/60 Hz

Nominal Power 100W

Rated Initial Lamp Lumen --

Declared CCT 5000K

LED Manufacturer OSRAM

LED Model DURIS S 5

Sample Receipt Date May.15.2014

Sample Number 140214-4

Photo

Page 5: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 14

2.1 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

IES LM-79 2008

Test date 2014-05-16 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number AP-HB-100W-LV

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

140214-4 120.0 60 0.7864 92.92 0.9845 7.78

277.0 60 0.3634 92.18 0.9157 17.34

Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 82 R9 14

Frequency (Hz) 60 R2 88 R10 71

Color Rendering Index (CRI) 83.5 R3 91 R11 82

R9 14 R4 83 R12 63

CCT (K) 5247 R5 83 R13 84

Chromaticity (x, y) x=0.3384 y=0.3452 R6 83 R14 95

Chromaticity (u’, v’) u'=0.2094 v'=0.4805 R7 87 R15 78

Duv -0.0005 R8 70 -- --

Goniophotometer Method:

Parameter Result

Test Voltage (V) 120.0

Frequency (Hz) 60

Total Luminous (lm) 7333.1

Luminous Efficacy (lm/W) 78.92

Beam Angle° 60.5

Center Beam Candle Power (cd) 5779

S/MH(C0/180) 0.86

S/MH(C90/270) 0.87

Page 6: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 14

Spectral Power Distribution

Spectral Power Distribution:

Page 7: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 14

Chromaticity Diagram

Page 8: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 14

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Lamp % Luminaire

0-30 3,509.3 47.9% 47.9%

0-40 4,941.7 67.4% 67.4%

0-60 6,566.2 89.5% 89.6%

60-90 750.1 10.2% 10.2%

70-100 339.7 4.6% 4.6%

90-120 0.7 0% 0%

0-90 7,316.3 99.8% 99.8%

90-180 15.4 0.2% 0.2%

0-180 7,331.7 100% 100%

Lumens Per Zone

Zone Lumens % Total Zone Lumens % Total

0-10 527.4 7.2% 90-100 0.0 0%

10-20 1,342.5 18.3% 100-110 0.2 0%

20-30 1,639.4 22.4% 110-120 0.5 0%

30-40 1,432.3 19.5% 120-130 1.2 0%

40-50 996.7 13.6% 130-140 2.3 0%

50-60 627.9 8.6% 140-150 3.4 0%

60-70 410.4 5.6% 150-160 3.7 0.1%

70-80 259.6 3.5% 160-170 2.9 0%

80-90 80.1 1.1% 170-180 1.2 0%

Page 9: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 14

Photometric Data

Illuminance Plots

Page 10: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 14

ISOCANDELA DIAGRAM

ISOLUX DIAGRAM

Page 11: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 14

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772 5772

1 5773 5770 5765 5759 5755 5752 5752 5754 5759 5764 5770 5773 5775 5778 5779 5778 5773

2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765

3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759 5761 5755 5747

4 5718 5708 5686 5664 5653 5644 5642 5645 5661 5676 5699 5712 5722 5735 5736 5728 5718

5 5680 5666 5640 5614 5601 5590 5588 5592 5609 5626 5657 5673 5684 5701 5701 5691 5680

6 5632 5614 5583 5552 5536 5528 5527 5532 5549 5567 5601 5623 5636 5657 5658 5645 5632

7 5573 5552 5518 5486 5468 5460 5458 5465 5483 5503 5536 5562 5578 5601 5605 5592 5573

8 5506 5482 5444 5411 5393 5385 5385 5393 5412 5431 5466 5494 5512 5538 5544 5527 5506

9 5432 5405 5365 5330 5312 5303 5304 5312 5332 5352 5386 5414 5435 5464 5470 5455 5432

10 5348 5321 5282 5247 5226 5218 5216 5225 5248 5267 5301 5331 5350 5380 5388 5375 5348

11 5261 5234 5194 5157 5133 5126 5124 5133 5156 5178 5211 5246 5260 5291 5302 5287 5261

12 5168 5144 5103 5062 5039 5031 5025 5037 5061 5084 5117 5152 5168 5200 5213 5194 5168

13 5070 5048 5008 4962 4938 4931 4927 4936 4960 4987 5020 5057 5072 5100 5115 5100 5070

14 4972 4948 4908 4858 4834 4825 4822 4834 4858 4883 4917 4958 4969 5001 5015 5000 4972

15 4870 4846 4807 4755 4730 4719 4719 4730 4752 4780 4817 4853 4865 4896 4911 4898 4870

16 4765 4740 4701 4645 4620 4608 4610 4620 4642 4669 4711 4746 4756 4788 4805 4789 4765

17 4657 4630 4589 4534 4505 4492 4497 4507 4529 4561 4602 4636 4642 4678 4698 4680 4657

18 4545 4515 4472 4417 4389 4376 4379 4391 4413 4446 4489 4521 4526 4563 4580 4565 4545

19 4428 4397 4355 4297 4266 4255 4258 4267 4293 4326 4372 4403 4406 4443 4462 4447 4428

20 4305 4275 4234 4175 4144 4133 4134 4142 4169 4203 4252 4281 4285 4321 4339 4324 4305

21 4181 4151 4109 4050 4018 4006 4008 4016 4042 4077 4128 4157 4160 4195 4211 4200 4181

22 4053 4023 3982 3925 3890 3875 3876 3884 3913 3947 3998 4029 4033 4067 4083 4075 4053

23 3924 3894 3853 3795 3760 3746 3742 3752 3780 3816 3866 3898 3906 3938 3951 3943 3924

24 3792 3765 3723 3665 3629 3613 3611 3620 3647 3684 3735 3767 3776 3807 3820 3813 3792

25 3662 3632 3591 3534 3499 3481 3477 3485 3513 3551 3600 3637 3646 3678 3689 3683 3662

26 3532 3501 3458 3402 3366 3349 3345 3351 3380 3415 3466 3505 3515 3546 3560 3552 3532

27 3399 3369 3324 3270 3237 3214 3212 3218 3251 3283 3332 3372 3383 3414 3426 3421 3399

28 3269 3236 3193 3136 3107 3080 3078 3086 3118 3151 3198 3241 3252 3283 3292 3288 3269

29 3139 3105 3059 3005 2976 2945 2945 2953 2985 3018 3064 3110 3119 3151 3162 3157 3139

Page 12: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 14

30 3006 2971 2925 2874 2845 2822 2814 2825 2852 2886 2931 2979 2989 3023 3031 3026 3006

31 2874 2842 2794 2743 2716 2694 2686 2697 2724 2756 2802 2848 2858 2894 2902 2897 2874

32 2748 2712 2662 2616 2591 2567 2557 2570 2596 2628 2672 2718 2729 2764 2772 2767 2748

33 2619 2584 2535 2489 2464 2442 2432 2443 2469 2500 2546 2589 2601 2635 2645 2639 2619

34 2493 2457 2409 2367 2346 2322 2311 2322 2347 2377 2422 2464 2476 2508 2519 2514 2493

35 2365 2333 2287 2246 2223 2203 2191 2202 2224 2256 2299 2339 2352 2384 2392 2389 2365

36 2245 2212 2167 2127 2109 2087 2078 2086 2107 2137 2179 2218 2230 2261 2271 2265 2245

37 2125 2093 2050 2014 1996 1975 1966 1975 1994 2024 2063 2100 2112 2142 2154 2146 2125

38 2009 1979 1938 1903 1887 1867 1859 1867 1883 1911 1951 1985 1998 2026 2039 2032 2009

39 1897 1867 1830 1796 1781 1764 1756 1763 1777 1805 1841 1875 1888 1915 1927 1919 1897

40 1790 1759 1724 1694 1681 1662 1656 1661 1675 1703 1736 1767 1781 1805 1817 1811 1790

41 1685 1655 1626 1596 1582 1568 1561 1566 1579 1605 1636 1665 1679 1701 1714 1706 1685

42 1585 1565 1537 1509 1491 1477 1470 1474 1487 1511 1541 1569 1580 1603 1613 1606 1585

43 1497 1474 1448 1422 1402 1390 1384 1387 1400 1422 1449 1477 1494 1514 1524 1516 1497

44 1409 1383 1359 1337 1320 1308 1302 1305 1318 1338 1363 1390 1407 1426 1435 1426 1409

45 1323 1298 1276 1256 1240 1230 1224 1227 1239 1258 1281 1305 1322 1340 1346 1339 1323

46 1239 1217 1197 1180 1165 1158 1151 1154 1166 1181 1204 1225 1240 1257 1261 1255 1239

47 1161 1141 1124 1107 1096 1089 1082 1085 1096 1110 1131 1151 1164 1179 1182 1176 1161

48 1088 1069 1055 1039 1029 1024 1018 1020 1030 1043 1062 1080 1091 1106 1107 1102 1088

49 1019 1003 989 976 968 963 957 959 969 981 998 1014 1024 1037 1037 1031 1019

50 956 941 929 916 910 906 901 902 911 922 938 952 961 973 973 968 956

51 897 884 872 861 856 853 848 850 857 867 882 895 903 913 912 907 897

52 842 830 821 811 806 802 799 800 806 816 829 840 848 858 856 852 842

53 791 781 771 763 759 757 753 754 761 768 780 790 797 806 804 799 791

54 745 735 727 719 717 714 711 712 717 724 735 744 750 758 756 752 745

55 701 692 685 679 677 675 673 673 677 684 694 701 706 714 712 707 701

56 660 652 647 642 641 640 637 638 641 647 655 662 666 672 670 666 660

57 623 615 612 608 607 607 605 605 608 612 620 626 628 634 632 628 623

58 588 581 579 576 576 577 574 574 577 581 588 592 594 599 596 592 588

59 556 549 548 546 547 548 546 545 547 551 557 561 563 565 563 560 556

60 526 520 520 519 520 522 520 519 521 524 529 532 533 535 533 529 526

61 498 493 493 493 494 498 495 494 496 498 503 505 506 507 505 501 498

Page 13: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 14

62 472 468 469 469 471 474 472 471 472 474 478 479 480 481 478 475 472

63 449 444 445 447 448 453 451 449 450 452 455 456 456 457 454 450 449

64 426 422 424 426 428 432 431 428 431 431 434 434 434 434 431 427 426

65 405 401 404 406 408 413 412 410 412 411 414 413 413 413 410 405 405

66 386 382 386 388 390 395 394 392 395 392 395 394 393 394 390 385 386

67 368 363 368 371 372 378 378 375 379 374 378 375 375 376 371 366 368

68 351 346 352 355 356 362 362 358 364 357 362 358 357 358 353 348 351

69 335 329 337 340 340 347 347 342 349 341 346 341 341 342 337 331 335

70 320 312 322 325 325 332 333 327 335 325 332 325 325 326 321 314 320

71 306 296 308 310 310 318 318 312 320 309 317 309 309 309 305 298 306

72 291 280 293 295 295 303 303 297 307 294 304 293 294 293 289 282 291

73 275 264 278 280 279 287 287 281 293 278 290 278 278 276 273 266 275

74 259 248 263 264 264 271 272 266 278 262 276 261 262 259 257 250 259

75 242 232 247 247 248 254 257 250 263 246 261 246 247 242 241 233 242

76 225 216 230 230 232 237 241 234 247 230 245 229 230 226 225 217 225

77 208 199 214 213 215 220 225 217 230 213 229 213 213 209 208 201 208

78 190 182 197 196 199 202 209 200 212 196 212 197 197 192 191 185 190

79 171 165 180 178 182 185 192 183 193 179 194 180 180 176 174 168 171

80 153 148 162 161 164 168 174 165 174 161 176 164 163 159 157 151 153

81 135 130 144 143 146 151 156 147 154 143 157 147 146 143 140 134 135

82 116 113 127 126 128 133 138 129 134 125 139 129 128 127 123 116 116

83 98 94 109 109 110 116 119 111 114 107 121 112 110 111 105 98 98

84 80 76 91 92 92 99 100 92 94 88 102 95 93 94 87 81 80

85 62 58 72 75 74 81 80 73 74 69 83 78 75 77 68 63 62

86 44 40 54 58 57 62 60 54 55 50 63 61 59 59 50 44 44

87 25 23 35 40 41 43 40 34 36 31 42 44 42 39 31 25 25

88 7 8 15 21 25 23 21 17 16 14 21 25 26 19 12 7 7

89 0 0 1 5 10 7 5 3 2 1 3 6 4 1 0 0 0

90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Page 14: LM-79-08 Test Report · 2 5765 5759 5748 5736 5729 5724 5725 5726 5736 5742 5756 5763 5767 5774 5774 5770 5765 3 5747 5738 5721 5704 5695 5689 5688 5691 5703 5713 5733 5742 5750 5759

NVLAP LAB CODE 201011-0

Report No.: GZN140214-D

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:8th floor, Block B, No. 11 Caipin Road, Guangzhou Science City, Tianhe, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 14

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-336 2 meter Integrating Sphere 2013-07-08 2014-07-07

ST-R-331 Spectral analysis system HAAS-2000 2013-06-21 2014-06-20

D204 Standard Lamp 2013-06-28 2014-06-27

PF2010 Power Meter for Integrating Sphere 2013-06-20 2014-06-19

EE-09 Goniophotometer system 2013-06-21 2014-06-20

D908S Standard Lamp 2013-07-05 2014-07-04

PF210 Power Meter for Goniophotometer 2013-06-20 2014-06-19

ST-R-181A Temperature Tester 2013-08-14 2014-08-13

****** END OF DATASHEET PACKAGE ******