Liner Hanger Selection

24
8/10/2019 Liner Hanger Selection http://slidepdf.com/reader/full/liner-hanger-selection 1/24 Liner Hanger Selection  A Guide for Drilling and Completion Engineers

Transcript of Liner Hanger Selection

Page 1: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 1/24

Liner Hanger Selection

 A Guide for Drilling and Completion Engineers

Page 2: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 2/24

Disclaimer This document has been developed to help drilling and completion engineers identify the liner hangerequipment best suited for their applications. All information, ratings, and recommendations are based onassumptions that may not apply to your specific objectives or well conditions; therefore, Weatherfordrecommends that you use this document only as a starting point for communications with Weatherford aboutyour liner needs. Then contact the authorized Weatherford representative for liner systems in your area todesign the system that is best for your application: www.weatherford.com.

This document does not cover all of Weatherford's liner hanger equipment; it covers the most readily availableequipment that is suited for conventional l iner applications. Your area's Weatherford liner systemsrepresentative may recommend other equipment that is better suited to the region or the application.

Page 3: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 3/24

Liner Hanger Selection 1st ed. May 2006

ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Liner Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Intermediate (Drilling) Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Production Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Drill-Down Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Extended-Reach Liners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Components of a Liner Hanger System. . . . . . . . . . . . . . . . . . . . . . . . . . 6

Liner-Top Packers/Liner Setting Sleeves and Tie-Back PBRs. . . . . . . . 6

Liner-Top Packers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Liner Setting Sleeves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Liner Hangers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Mechanical Liner Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Hydraulic Liner Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Cement Displacement Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Cementing Packoffs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Liner Wiper Plugs, Drillpipe Darts and Landing Collars. . . . . . . . . . 14

Liner Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Holddown Subs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Centralizers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Multi-Stage Cementing Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

 ACP™ Annulus Casing Packers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Float Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Reamer Shoes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

DrillShoe™ Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Liner Tie-Backs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Tie-Back Seal Stems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Tie-Back Packers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Liner Hanger Selection Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

 Contents

© 2006-2010 Weatherford. All rights reserved. 1

Page 4: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 4/24

Page 5: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 5/24

3© 2006-2010 Weatherford. All rights reserved.Liner Hanger Selection 1st ed. May 2006

IntroductionDesigning a liner hanger installation can be complexbecause it involves many variables; but the followingselection criteria are essential:

Size, weight, grade, and setting depth of casing

Size, weight, grade, connections, and length of liner 

Setting depth of liner hanger 

Inclination of liner hanger 

Proposed trajectory of liner wellbore

Size and weight of drillpipe

Liner application

Completion/stimulation operations after the liner isinstalled

Loads applied to the liner hanger from the liner weight and fromhydraulic operations

Completion and/or wellbore fluids to which the liner may be exposed

Pressures and temperatures to which liner equipment may be exposed

 All of these considerations must go into the design of a liner system thatwill meet your needs while remaining within the operational capabilities

of the equipment.

 Introduction

Page 6: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 6/24

Page 7: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 7/24

Page 8: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 8/24

6 © 2006-2010 Weatherford. All rights reserved. Liner Hanger Selection 1st ed. May 2006

 Components of a Liner Hanger System

Components of a Liner Hanger System A typical liner hanger system consists of the following components:

Liner-top polished bore receptacle (PBR), also known as a tie-backsleeve or tie-back extension

Liner-top packer or liner setting sleeve

Liner hanger 

Cement displacement system consisting of cementing packoff,wiper plug, drillpipe dart, and landing collar

Float collar 

Float shoe

Running tools are also required for running the liner hanger to bottom,setting it, executing a cement job, and setting the liner-top packer (ifapplicable). A typical liner running-tool string will consist of thefollowing:

Debris protection system

Packer setting tool

Liner running tool

Retrievable cementing packoff 

Plug adaptor 

Wiper plug

Liner-Top Packers/Liner Setting Sleeves and Tie-Back PBRs

 All liners consist of either a liner-top packer or a liner setting sleeve, which connects the liner to the running tool. All liner-top packers and most setting sleeves also are used in conjunction with a tie-back polished borereceptacle (PBR).

For many reasons liner-top packers are used to isolate the liner top after the hanger is set and cementingoperations are completed:

Isolation of formation pressure below the liner-top from the casing ID above

Isolation of treating pressures below the liner-top during fracture or acid work

Isolation of formation fluids while the cement sets, helping to stop gas migrationIsolation of lost-circulation zones

The only isolation above the production zone in uncemented liners

The liner-top packer can also be used as a tie-back completion or production packer.

 A liner setting sleeve is used as an alternative to a liner-top packer and provides the means by which the runningtool deploys the liner. A PBR is attached for tying back the liner either to surface, with a tie-back packer, or with ascab liner.

Liner-Top Packers

Liner Setting Sleeves

Page 9: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 9/24

Liner Hanger Selection 1st ed. May 2006

Weatherford Liner-Top Packers

Weatherford has three types of liner-top packers:

The TSP4 liner-top packer is a premium packer that is suited formost applications. The packer features holddown slips and anelement that is rated to 7,500 psi (48.3 MPa) at 300°F (149°C) inmost sizes. The packer is set by setting down weight through thetie-back PBR. The PBR also supplies a means for liner tie-back

operations. It is available with a profile for either the R or the HNGrunning tool. It is also available with a high-pressure packing elementwith a differential pressure rating that exceeds 7,500 psi (51.7 MPa).

The TSP5 liner-top packer is identical to the TSP4 except that it islock-wired to the PBR; that is, the PBR cannot be backed off even ifthe liner is rotated aggressively down to depth. This packer is idealfor drilldown or extended-reach applications.

The WCTSP4 liner-top packer is set by setting down weight on thePBR in the same manner as with the TSP4 and TSP5 liner-top

packers. The WCTSP4 is available with or without holddown slipsand with profiles for either the R or the HNG running tool. Theelement is rated for 5,000 psi (34.5 MPa) at 300°F (149°C) and isideal for any application that does not exceed this differential

TSP4 Liner-Top Packer 

TSP5 Liner-Top Packer 

WCTSP4 Liner-Top Packer 

 Components of a Liner Hanger System

WCTSP4 liner-top packer with HNG running tool profile

7© 2006-2010 Weatherford. All rights reserved.

Page 10: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 10/24

8 © 2006-2010 Weatherford. All rights reserved. Liner Hanger Selection 1st ed. May 2006

Components of a Liner Hanger System

Liner Hangers

Most liner hangers can be categorized by their setting mechanism, which is either hydraulic or mechanical.Hangers can be further defined by other features or abilities, such as the number of cones and the ability to rotateafter the hanger has been set.

Cones. In general, a greater number of cones means increased hanging capacity, but it also means longer andmore expensive assemblies.

Liner system design takes into account more parameters than hanging capacity such as additional loads appliedto the liner hanger. A 7-in. liner hanger that can accommodate an 800,000-lbf (3,559-kN) load in 9 5/8-in.,47-lb/ft N-80 casing may carry 7-in., 29-lb/ft L-80 pipe that is only good for 676,000-lbf (3,007-kN). The additional

hanging capacity may be required to prevent the hanger from failing should pressure be applied to the liner top.Weatherford's liner hangers are designed to maximize hanging capacity to carry long liners while supportingpressure-induced loads.

Rotating versus non-rotating liner hangers. Rotating-style hangers feature a bearing that allows the linerhanger body to rotate independently of the slips and cone. This capability allows rotation of the liner after the slipshave been set into the host casing. Rotation of the liner during cementation significantly improves the quality ofthe cement bond.

Rotatable versus non-rotatable liner hangers. Rotatable liner hangers can be rotated to bottom, depending onthe liner hanger design and the type of running tool used—not on the liner hanger itself. Conventional mechanicalliner hangers that rely on drag springs for setting are non-rotatable, as rotation before setting the hanger candamage the drag springs.

Protected slips. Protected slips are slips that are protected inside recesses in the liner hanger. This design

shields them from damage even if the liner is worked vigorously to reach setting depth. Protected slips arepreferred for drilldown or ream-down applications, where damage to the slips is more likely.

 A mechanical liner hanger is set by string manipulation. The simplest mechanical liner hanger setting feature is aJ mechanism. This design is easy to operate and reliably sets the hanger: It is picked up and rotated in the settingdirection (usually right); then weight is slacked down on the hanger to set it.

The main advantage of mechanical liner hangers over hydraulic models is the absence of a port in the body totransmit setting pressure.

The main disadvantage of mechanical liner hangers is that deploying them to bottom and in deviated and/orextremely deep wells can be difficult. With mechanical liner hangers, manipulating the liner with the drillpipethrough tight spots and setting it are difficult tasks. Rotation while running in hole can be problematic and can

damage the setting mechanism (drag spring). In addition, setting mechanical liner hangers is difficult—if notimpossible—should the liner become stuck.

Mechanical Liner Hangers

Page 11: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 11/24

Liner Hanger Selection 1st ed. May 2006

 Components of a Liner Hanger System

Weatherford Mechanical Liner Hangers

Weatherford’s four main mechanical liner hangers are the CSM, CTM,CRM, and PMR.

The C-series single-cone mechanical (CSM) liner hanger features asingle cone and a right-hand setting mechanism. It is easy to operateand has adequate hanging capacity for medium to long liners.

The C-series tandem-cone mechanical (CTM) liner hanger featurestandem cones and a right-hand setting mechanism. It functionsidentically to the CSM liner hanger but provides twice the hangingcapacity, which is ideal for all but the longest liners.

The C-series rotating mechanical (CRM) liner hanger features a singlecone, a right-hand setting mechanism, and a bearing. The bearingallows for rotation of the liner after the hanger is set. The CRMfunctions identically to the CSM and has the same hanging capacity,but it also allows rotation of the liner after the hanger is set.

The premium mechanical rotating (PMR) liner hanger features tandemcones, protected slips, and a heavy-duty bearing. It is Weatherford'stop-of-the-line mechanical liner hanger. The PMR functions identicallyto the other mechanical liner hangers but has greater hangingcapacity, a heavy-duty bearing, and protected slips.

CSM Liner Hanger 

CTM Liner Hanger 

CRM Liner Hanger 

PMR Liner Hanger 

9© 2006-2010 Weatherford. All rights reserved.

C-series rotating mechanical (CRM) linerhanger 

Page 12: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 12/24

10 © 2006-2010 Weatherford. All rights reserved.

Components of a Liner Hanger System

Hydraulic Liner Hangers

 A hydraulic liner hanger is set by differential pressureacross the hydraulic cylinder in the liner hanger. Toprevent the hanger from pre-setting during deployment,the hydraulic cylinder is shear-pinned in place. Usuallythe maximum circulating pressure before the hanger isset is 50 percent of this setting pressure. A typical settingprocedure for a hydraulic liner hanger requires droppinga ball, landing the ball on seat, pressuring up against itto activate the liner hanger, and then slacking downweight on the liner hanger.

The main advantage of hydraulic liner hangers overmechanical models is that they can be set in high-angleand/or extremely deep wells because drillstring or linermanipulation is not required to activate them. Unlikemechanical models, hydraulic liner hangers do notfeature drag springs; therefore, they can be rotated andreciprocated to bottom with the correct running tools.

Page 13: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 13/24

© 2006-2010 Weatherford. All rights reserved. 11Liner Hanger Selection 1st ed. May 2006

 Components of a Liner Hanger System

Weatherford Hydraulic Liner Hangers

Weatherford’s five main hydraulic liner hangers are the PHR, PHS,CSH, CTH, and CRH.

The premium hydraulic rotating (PHR) liner hanger is Weatherford'stop-of-the-range liner hanger. It features protected slips, a heavy-dutybearing, and tandem cones. It has the highest hanging capacity of allWeatherford liner hangers and can be deployed in even the most

challenging wells. The hanger can be rotated after the slips is set andis typically run in conjunction with a rotating running tool, which allowsvigorous rotation of the liner to bottom. The PHR liner hanger is idealfor drilldown and extended-reach liners.

The premium hydraulic static (PHS) liner hanger is almost identical tothe PHR; however, it does not feature a bearing and does not allowrotation of the liner after the hanger is set.

Weatherford's C-series single-cone hydraulic (CSH) liner hanger has asingle cone and is suitable for medium to long liners. It can be rotated

during deployment; but, with its unprotected slips, the CSH linerhanger is not ideal for drilldown or ream-down applications.

Weatherford's C-series tandem-cone hydraulic (CTH) liner hanger hastandem cones and is suitable for all but the longest liners. It can berotated during deployment; but, with its unprotected slips, the CTH linerhanger is not ideal for drilldown or ream-down applications.

Weatherford's C-series rotating-cone hydraulic (CRH) liner hanger hasa single cone and a bearing. It allows rotation of the liner after the

hanger has been set and is suitable for medium to long liners. TheCRH liner hanger can be rotated during deployment; but, with itsunprotected slips, the CRH liner hanger is not suitable for drilldown orream-down applications.

PHR Liner Hanger 

PHS Liner Hanger 

CSH Liner Hanger 

CTH Liner Hanger 

CRH Liner Hanger 

C-series single-cone hydraulic (CSH) linerhanger 

Page 14: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 14/24

12 © 2006-2010 Weatherford. All rights reserved.

Components of a Liner Hanger System

Cement Displacement Systems

 A liner cement displacement system consists of a cementing packoff, a liner wiper plug, a drillpipe dart, and alanding collar. Each component aids the cementing operation.

 A retrievable cementing packoff is used to provide a seal between the liner ID and the running string OD. The sealensures that cement passes through the liner shoe and also allows for use of pressure to set hydraulic hangers.The main advantage of a retrievable cementing packoff over a drillable one is time savings: No drill-out isnecessary. Weatherford's three retrievable cementing packoffs are the RSM, the RKC, and the PBR.

Cementing Packoffs

Page 15: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 15/24

Liner Hanger Selection 1st ed. May 2006 13© 2006 Weatherford. All rights reserved.

Remote-control top-drivecementing head (RC-TDH)

 Components of a Liner Hanger System

Weatherford Cementing Heads

Weatherford has three types of cementing heads that it uses to cementliners, including two top-drive cementing heads (the TDH and theRC-TDH) and one rotary rig-type cementing head (the LW).

The TDH is one of the premium cementing heads on the market. Itfeatures two dart valves (so that two darts can be launched), a ballreleaser, and a flag indicator sub. It also features a premium swivel so

that, as the head is being rotated by the top drive, the connectedcement line remains static. The TDH has been DNV certified, and thecertification process for current models is under way. The ball releaserand dart valves are all hand operated with wheels on the outside of thecementing head.

The RC-TDH is the market leader. It has all features of the TDH, butthe ball release, dart valves, and indicator sub are all actuated byremote control to significantly enhance safety. The RC-TDH also savestime because rotation can continue as balls and darts are released andthe indicator sub is re-set.

The LW cementing head is designed for use with rotary-based rigs;therefore it features a swivel assembly beneath all of its primarycomponents. The LW also features a single dart valve and ball releaserand can be fitted with a separate indicator sub. The ball releaser anddart valve are hand operated with wheels on the outside of thecementing head.

Top-Drive Cementing Head (TDH)

Remote-Control Top-Drive Cementing Head (RC-TDH)

Lightweight (LW) Cementing Head

Page 16: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 16/24

Liner Hanger Selection 1st ed. May 200614 © 2006-2010 Weatherford. All rights reserved.

Components of a Liner Hanger System

Liner Wiper Plugs, Drillpipe Darts andLanding Collars

 A liner wiper plug is used as a mechanical barrierbetween the cement and the displacement fluid. Itdisplaces the cement and also wipes the liner ID,removing any cement or debris that may be clingingto it.

 A drillpipe dart acts nearly identically to a wiper plugexcept that it displaces the cement in the drillpipeand wipes the drillpipe ID. The drillpipe dart lands in

the liner wiper plug and is used to launch it from thebottom of the running tools. The drillpipe dart featuresan anti-rotation ring, which locks it in position when itlatches into the wiper plug.

 A landing collar  is used to stop the wiper plugbefore it reaches the float equipment. All sizes andmodels of landing collars feature an anti-rotationmechanism; most sizes and models also feature alatch-down design that provides a positive seal inboth directions.

Page 17: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 17/24

15© 2006-2010 Weatherford. All rights reserved.Liner Hanger Selection 1st ed. May 2006

 Components of a Liner Hanger System

Single wiper plug (SWP)with ball seat

Liner wiper plug (LWP)

Weatherford Liner Wiper Plugs, Drillpipe Darts* andLanding Collars

SWP Single Wiper Plug with Ball Seat, Drillpipe Dart and LandingCollar Lite

DWP Dual Wiper Plug with Ball Seat, Drillpipe Dart and LandingCollar Lite

LWP Liner Wiper Plug, Drillpipe Dart and HLC Landing Collar 

FLWP Liner Wiper Plug and FLWP Landing Collar 

TMSub-Surface Release Wiper Plugs, Drillpipe Darts and507P Landing Collar

Weatherford's SWP with ball seat is the premium single liner wiperplug. The ball seat in the wiper plug helps land the ball on seat even inthe most deviated liner applications.

The DWP with ball seat is Weatherford's premium dual liner wiper plugsystem. It consists of a plug that is launched in front of the cement anda plug that is launched behind the cement. The ball seat in the plughelps land the ball on seat.

The LWP is a single liner wiper plug without ball seat. It is used inconjunction with an HLC landing collar, which typically has a ball seatthat is used to activate hydraulic liner hangers and running tools. TheLWP is applicable for wells without excessive deviation.

The FLWP wiper plug is a full-length wiper plug (or drillpipe dart) thatwipes the ID of the liner and the drillpipe. It typically is run as a dualplug system but can also be run as a single plug. The landing collarcomes complete with a catcher tube and ball seat.

Sub-Surface Release plugs are the best plugs for displacing cement inliners larger than 8-5/8 in. They come in various designs, and bothsingle and dual liner wiper plug models are available. These plugstypically are used with the 507P landing collar.

*Weatherford’s drillpipe darts should only be used in strings that meetthe following criteria: 1) any ID transition of 1 in. or more must be 30°or less; and 2) any ID transition of less than 1 in. must be 45° or less.

Page 18: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 18/24

Liner Hanger Selection 1st ed. May 200616 © 2006-2010 Weatherford. All rights reserved.

Liner Accessories

Liner Accessories

Weatherford produces numerous liner accessories, the most common beingholddown subs, float equipment, and centralizers; but multi-stage cementaccessories and ACP™ annulus casing packers are also frequently used.

 A holddown sub is used to prevent the liner from being unset and pushed upthe well by hydrostatic or frictional forces. It also can be used to giveadditional indication of release of the running tool. The main applications arelight liners and liners run in conjunction with an inner string.

 A centralizer is used to help centralize the string during cementing to ensuregood cementation and help prevent differential sticking. Weatherford

®manufactures several kinds of centralizers—from the SpiraGlider model tosolid-body and conventional bow-spring versions. Centralizer placement can

®be designed and optimized using Weatherford's proprietary CentraPro Plussoftware.

These accessories are used for unconventional cementation process andinclude hydraulically actuated stage collars and mechanically actuated port

collars. They are usually used to cement above an ACP  packer and preventthe cement from traveling below it.

 A hydraulic stage collar  decreases operating time but also requires drill-out(It is closed by a plug) and allows for only one stage collar to be used. Amechanical port collar  does not require drill-out but requires a morecomplex operation, which includes an inner string.

 An annulus casing packer can be used as a mid-string packer and is inflatedwith either mud or cement, depending on the application. In some formationshydrostatic pressure from the cement can fracture very long cemented liners;but the annulus casing packer provides a reliable seal to protect the liner. An

annulus casing packer can also be used for added isolation of problemformations or water-producing formations.

Holddown Subs

Centralizers

Multi-Stage Cementing Accessories

ACP™ Annulus Casing Packers

SHE holddown sub

Page 19: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 19/24

17© 2006-2010 Weatherford. All rights reserved.

 Liner Accessories

Float Equipment

Reamer Shoes

DrillShoe™ Tools

Weatherford produces numerous types of float equipment, including Model402 float collars and Model 323/329 float shoes, which are ideal for linerapplications. These float equipment items include the Sure-Seal 3™ valve,which meets API requirement RP10Fs for float equipment.

Weatherford also manufactures auto-fill, differential-fill, and surge-reducingfloat equipment. These types of equipment can be used to reduce runningtime, as liner and drillpipe joints do not have to be filled. These types ofequipment can also be used to protect the formation from damage inducedby surge forces.

Weatherford produces the Diamondback™ reamer shoe, which can beused to ream the liner through difficult sections, such as swelling shaleformations. The reamer shoe can feature up to two Sure-Seal 3 valves andcomes complete with carbide cutting structures to help open tight spots inthe well. If getting the liner to bottom is a concern, Weatherford highlyrecommends that a Diamondback  reamer shoe be run in conjunction witheither a Weatherford PHR or PHS liner hanger.

 A Weatherford DrillShoe assembly can be used in conjunction with a linerto drill additional hole, the length of which depends on the DrillShoe modeland the type of formation.

Model 402 float collar withSure-Seal 3 valve

 Weatherford’s DrillShoe IIdrilling assembly

Page 20: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 20/24

Liner Hanger Selection 1st ed. May 200618 © 2006-2010 Weatherford. All rights reserved.

Liner Accessories

Liner Tie-Backs

Sometimes it is necessary to tie a liner back into an existing liner.Weatherford offers several liner tie-back products.

 A tie-back seal stem is fitted with molyglass seals and creates an effectiveseal with the liner-top PBR. Applications for tie-back seal stems includetemporary tie-back liners (drilling tie-backs), scab liners, cemented tie-backliners, and tie-back packers that use top-set liner-top packers. Some sealstems feature cementing ports between two of the seal stacks so that the tie-back string can be cemented in place.

 A tie-back packer features a seal stem, a packing element, holddown slips,and a liner-top PBR. It is run as a second-trip packer when a liner that wasrun with a setting sleeve requires liner-top isolation. It is also run as a backupin case the original liner-top packer leaks. In most cases a tie-back packer isa reliable and cost-effective alternative to an expensive liner-top squeeze.

Tie-Back Seal Stems

Tie-Back Packers

Weatherford Tie-Back Packers

Weatherford runs two types of tie-back packers: those consisting of a

seal stem with a standard liner-top packer and those consisting of abottom-set tie-back packer run in conjunction with a setting sleeve andliner-top PBR.

Weatherford's BSP is a premium tie-back packer that is set by slackingdown weight on the running tool and through the setting sleeve. Theweight pushes the external components of the BSP against the liner-topPBR, setting the packing element and holddown slips.

BSP tie-back packer 

Page 21: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 21/24

19© 2006-2010 Weatherford. All rights reserved.

Liner Hanger Selection Process

Liner Hanger Selection 1st ed. May 2006

Liner Hanger Selection ProcessWhile liner hanger system design is complex, with numerous variables, the following guidelines should help youunderstand the issues to consider for your liner applications. The guidelines are based on assumptions thatinclude host casing size and weight, liner size and weight, and buoyancy factors; but many pressure andtemperature factors have not been taken into consideration. An authorized Weatherford liner hangerrepresentative will help finalize the design that is right for your well.

Hydraulic or mechanical liner hanger. Ease of setting and lowest risk are the determining factors in theselection of a hydraulic or mechanical liner hanger. If the hanger is to be set extremely deep (more than 10,000 ft,or 3,048 m), or if the hanger is to be set in or below a moderately deviated section (more than 30°), a hydraulicliner hanger is recommended. Setting a mechanical liner hanger under these conditions would be difficult. Inaddition, if a liner must be worked down to depth, a conventional mechanical hanger should be ruled out.

For all other applications, either a hydraulic or a mechanical liner hanger can be used.Single- or tandem-cone liner hanger. If the liner weight plus additional loads that may be applied to the hangerexceeds the hanging capacity of a single-cone hanger, a tandem-cone model may be required. If the total loadapplied exceeds the capacity of a tandem-cone hanger, a premium hanger (such as the PHR, PHS, or PMRhanger) is needed.

Working down the liner. If the liner must be reamed, drilled down, or worked through difficult formations, a PHRor a PHS hanger is the best choice.

Ball seat location. If any part of the liner is in a highly deviated section (more than 60°), Weatherfordrecommends locating the ball seat in the wiper plug or in the running tools (achievable with the MX mechanicallyexpanded ball seat). SWP or DWP wiper plugs are recommended for this type of application.

For most other applications a ball seat in the landing collar will suffice; however, for larger liners, where the linerID is greater than three times the ball OD, a ball seat in the landing collar may be difficult.

Other factors. Most other factors for selecting a liner hanger and related components are driven more by theclient than by any property of the liner. These factors are beyond the scope of this document.

The flow charts that follow capture the process of liner hanger selection.

Page 22: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 22/24

20 © 2006-2010 Weatherford. All rights reserved.

Liner Hanger Selection Process

Liner Hanger Selection 1st ed. May 2006

Is the liner longer thanthe

?single-cone

critical length

 YesTandem cone

NoSingle cone

Would rotation of the LHimprove the cement bond?

Would rotation of the LHimprove the cement bond?

NoTandem-conenon-rotating

LH

NoCasing-bodied

single-conehydraulic (CSH)

LH

Does the liner have to be worked or reamed downvigorously, or is the liner 

longer than the?tandem-cone critical length

Does the liner have to be worked or reamed down

vigorously?

NoCasing-bodied,

tandem-cone hydraulic(CTH) LH

NoCasing-bodied,

rotating hydraulic(CRH) LH

 YesPremium hydraulic static

(PHS) LH

 YesPremium hydraulic

rotating(PHR) LH

 YesPremium hydraulic

rotating(PHR) LH

 YesRotating LH

Size (in.) 4-1/2 x 7 5 x 7 5-1/2 x 7-5/8 7 x 9-5/8 7-5/8 x 9-5/8

Single-Cone (ft/m )3,609

1,100 

3,117

950 

3,281

1,000 

Tandem-Cone (ft/m )7,218

2,200 

6,234

1,900 

6,562

2,000 

11,811

3,600

5,905

1,800 

4 1/2- x 7-in., 5 1/2- x 7 5/8-in., 7- x 9 5/8-in., and 7 5/8- x 9 5/8-in.Hydraulic-Set Liner Hangers

Liner Hanger Critical Lengths

Note: Weatherford liner hangers can, in some cases, support significantly longer strings of casing than indicated. Thevalues shown were calculated based on extremely challenging parameters.

Page 23: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 23/24

21© 2006-2010 Weatherford. All rights reserved.

Liner Hanger Selection Process

Liner Hanger Selection 1st ed. May 2006

9 5/8- x 13 3/8-in. and 13 3/8- x 16-in.Large-Bore Hydraulic-Set Liner Hangers

9 5/8- x 11 3/4-in., 11 3/4- x 13 3/8-in., and 16- x 20-in.Large-Bore Hydraulic-Set Liner Hangers

Would rotation of the LHimprove the cement bond?

 YesPremium hydraulic

rotating(PHR) LH

NoPremium hydraulic

static (PHS)LH

Premium hydraulicstatic (PHS)

LH

Premium hydraulic static(PHS) liner hanger 

Page 24: Liner Hanger Selection

8/10/2019 Liner Hanger Selection

http://slidepdf.com/reader/full/liner-hanger-selection 24/24

515 Post Oak Blvd., Suite 600Houston, Texas 77027 USATel: 713-693-4000

Weatherford products and services are subject to the Company’s standard termsand conditions, available on request or at www.weatherford.com. For moreinformation contact an authorized Weatherford representative. Unless notedotherwise, trademarks and service marks herein are the property of Weatherford.Specifications are subject to change without notice

Liner Hanger Selection