INVERTEC ® V350-PRO OPERATOR’S MANUAL For use with machines Code 10873, 10874, 10876, 10934, 11445 11481, 11482, 11484 IM731-C October, 2007 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you act and be careful. WARNING WARNING AVISO DE PRECAUCION ATTENTION ! ! ! ! A AMPS A V VOLTS WELD TERMINALS SELECT OUTPUT HOT START ARC CONTROL -4 +4 +2 -2 0 -6 +6 -10 SOFT CRISP +10 -8 +8 5 4 3 2 1 0 6 10 9 8 7 SELECT CC-STICK 7018 CC-STICK 6010 TIG GTAW CV-WIRE CV-FLUX CORED • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • w NRTL/C Copyright © Lincoln Global Inc.

Transcript of Lincoln V350-PRO Manual - Beal College - Welding Test...

Page 1: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

INVERTEC®® V350-PRO

OPERATOR’S MANUAL

FFoorr uussee wwiitthh mmaacchhiinneess CCooddee 1100887733,, 1100887744,, 1100887766,, 1100993344,, 11114444551111448811,, 1111448822,, 1111448844

IM731-COctober, 2007

Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. However, youroverall safety can be increased byproper installation ... and thought-ful operation on your part. DONOT INSTALL, OPERATE ORREPAIR THIS EQUIPMENTWITHOUT READING THISMANUAL AND THE SAFETYPRECAUTIONS CONTAINEDTHROUGHOUT. And, mostimportantly, think before you actand be careful.

WARNINGWARNING

AVISO DEPRECAUCION

ATTENTION

!

!

!

!

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

WARNING

REMOTE

POWER

OFF

ON

A AMPS

A

V VOLTS

WELD TERMINALS

SELECT

OUTPUT

HOT START

ARC CONTROL-4

+4

+2

-2 0

-6

+6-10SOFTCRISP+10

-8

+8

543

2

1

0

6

109

8

7

SELECT

CC-STICK 7018CC-STICK 6010TIG GTAWCV-WIRECV-FLUX CORED

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

w

NRTL/C

Copyright © Lincoln Global Inc.

Page 2: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

FOR ENGINEpowered equipment.

1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

____________________________________________________1.b. Operate engines in open, well-ventilated

areas or vent the engine exhaust fumes outdoors.

____________________________________________________1.c. Do not add the fuel near an open flame

welding arc or when the engine is running.Stop the engine and allow it to cool beforerefueling to prevent spilled fuel from vaporiz-ing on contact with hot engine parts andigniting. Do not spill fuel when filling tank. Iffuel is spilled, wipe it up and do not startengine until fumes have been eliminated.

____________________________________________________1.d. Keep all equipment safety guards, covers and devices in

position and in good repair.Keep hands, hair, clothing andtools away from V-belts, gears, fans and all other movingparts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safetyguards to perform required maintenance. Removeguards only when necessary and replace them when themaintenance requiring their removal is complete.Always use the greatest care when working near movingparts.

___________________________________________________1.f. Do not put your hands near the engine fan.

Do not attempt to override the governor oridler by pushing on the throttle control rodswhile the engine is running.

___________________________________________________1.g. To prevent accidentally starting gasoline engines while

turning the engine or welding generator during maintenancework, disconnect the spark plug wires, distributor cap ormagneto wire as appropriate.

iSAFETYi

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that youpurchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is availablefrom the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES AREPERFORMED ONLY BY QUALIFIED INDIVIDUALS.

WARNING

Mar ʻ95

ELECTRIC AND MAGNETIC FIELDSmay be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, andwelders having a pacemaker should consult their physicianbefore welding.

2.c. Exposure to EMF fields in welding may have other healtheffects which are now not known.

2.d. All welders should use the following procedures in order tominimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Securethem with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode andwork cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close aspossible to the area being welded.

2.d.5. Do not work next to welding power source.

1.h. To avoid scalding, do not remove theradiator pressure cap when the engine ishot.

CALIFORNIA PROPOSITION 65 WARNINGSDiesel engine exhaust and some of its constituentsare known to the State of California to cause can-cer, birth defects, and other reproductive harm.

The engine exhaust from this product containschemicals known to the State of California to causecancer, birth defects, or other reproductive harm.

The Above For Diesel Engines The Above For Gasoline Engines

Page 3: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

iiSAFETYii

ARC RAYS can burn.4.a. Use a shield with the proper filter and cover

plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistantmaterial to protect your skin and that of your helpers fromthe arc rays.

4.c. Protect other nearby personnel with suitable, non-flammablescreening and/or warn them not to watch the arc nor exposethemselves to the arc rays or to hot spatter or metal.

ELECTRIC SHOCK cankill.3.a. The electrode and work (or ground) circuits

are electrically “hot” when the welder is on.Do not touch these “hot” parts with your bareskin or wet clothing. Wear dry, hole-free

gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation.Make certain the insulation is large enough to cover your fullarea of physical contact with work and ground.

In addition to the normal safety precautions, if weldingmust be performed under electrically hazardousconditions (in damp locations or while wearing wetclothing; on metal structures such as floors, gratings orscaffolds; when in cramped positions such as sitting,kneeling or lying, if there is a high risk of unavoidable oraccidental contact with the workpiece or ground) usethe following equipment:

• Semiautomatic DC Constant Voltage (Wire) Welder.• DC Manual (Stick) Welder.• AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode,electrode reel, welding head, nozzle or semiautomaticwelding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electricalconnection with the metal being welded. The connectionshould be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical(earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable andwelding machine in good, safe operating condition. Replacedamaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts ofelectrode holders connected to two welders because voltagebetween the two can be the total of the open circuit voltageof both welders.

3.i. When working above floor level, use a safety belt to protectyourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

FUMES AND GASEScan be dangerous.5.a. Welding may produce fumes and gases

hazardous to health. Avoid breathing thesefumes and gases. When welding, keepyour head out of the fume. Use enoughventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. Whenwelding with electrodes which require specialventilation such as stainless or hard facing (seeinstructions on container or MSDS) or on lead orcadmium plated steel and other metals or coatingswhich produce highly toxic fumes, keep exposure aslow as possible and below Threshold Limit Values (TLV)using local exhaust or mechanical ventilation. Inconfined spaces or in some circumstances, outdoors, arespirator may be required. Additional precautions arealso required when welding on galvanized steel.

5. b. The operation of welding fume control equipment is affectedby various factors including proper use and positioning ofthe equipment, maintenance of the equipment and the spe-cific welding procedure and application involved. Workerexposure level should be checked upon installation andperiodically thereafter to be certain it is within applicableOSHA PEL and ACGIH TLV limits.

5.c. Do not weld in locations near chlorinated hydrocarbon vaporscoming from degreasing, cleaning or spraying operations.The heat and rays of the arc can react with solvent vapors toform phosgene, a highly toxic gas, and other irritating prod-ucts.

5.d. Shielding gases used for arc welding can displace air andcause injury or death. Always use enough ventilation,especially in confined areas, to insure breathing air is safe.

5.e. Read and understand the manufacturerʼs instructions for thisequipment and the consumables to be used, including thematerial safety data sheet (MSDS) and follow youremployerʼs safety practices. MSDS forms are available fromyour welding distributor or from the manufacturer.

5.f. Also see item 1.b.

AUG 06

Page 4: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

iiiSAFETYiii

FOR ELECTRICALLYpowered equipment.

8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.

8.b. Install equipment in accordance with the U.S. NationalElectrical Code, all local codes and the manufacturerʼsrecommendations.

8.c. Ground the equipment in accordance with the U.S. NationalElectrical Code and the manufacturerʼs recommendations.

CYLINDER may explodeif damaged.7.a. Use only compressed gas cylinders

containing the correct shielding gas for theprocess used and properly operatingregulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable forthe application and maintained in good condition.

7.b. Always keep cylinders in an upright position securelychained to an undercarriage or fixed support.

7.c. Cylinders should be located:• Away from areas where they may be struck or subjected tophysical damage.

• A safe distance from arc welding or cutting operations andany other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any otherelectrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outletwhen opening the cylinder valve.

7.f. Valve protection caps should always be in place and handtight except when the cylinder is in use or connected foruse.

7.g. Read and follow the instructions on compressed gascylinders, associated equipment, and CGA publication P-l,“Precautions for Safe Handling of Compressed Gases inCylinders,” available from the Compressed Gas Association1235 Jefferson Davis Highway, Arlington, VA 22202.

Jan, 07

WELDING and CUTTINGSPARKS cancause fire or explosion.6.a. Remove fire hazards from the welding area.

If this is not possible, cover them to preventthe welding sparks from starting a fire.

Remember that welding sparks and hotmaterials from welding can easily go through small cracksand openings to adjacent areas. Avoid welding nearhydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site,special precautions should be used to prevent hazardoussituations. Refer to “Safety in Welding and Cutting” (ANSIStandard Z49.1) and the operating information for theequipment being used.

6.c. When not welding, make certain no part of the electrodecircuit is touching the work or ground. Accidental contactcan cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until theproper steps have been taken to insure that such procedureswill not cause flammable or toxic vapors from substancesinside. They can cause an explosion even though they havebeen “cleaned”. For information, purchase “RecommendedSafe Practices for the Preparation for Welding and Cutting ofContainers and Piping That Have Held HazardousSubstances”, AWS F4.1 from the American Welding Society(see address above).

6.e. Vent hollow castings or containers before heating, cutting orwelding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oilfree protective garments such as leather gloves, heavy shirt,cuffless trousers, high shoes and a cap over your hair. Wearear plugs when welding out of position or in confined places.Always wear safety glasses with side shields when in awelding area.

6.g. Connect the work cable to the work as close to the weldingarea as practical. Work cables connected to the buildingframework or other locations away from the welding areaincrease the possibility of the welding current passingthrough lifting chains, crane cables or other alternate cir-cuits. This can create fire hazards or overheat lifting chainsor cables until they fail.

6.h. Also see item 1.c.

6.I. Read and follow NFPA 51B “ Standard for Fire PreventionDuring Welding, Cutting and Other Hot Work”, availablefrom NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma022690-9101.

6.j. Do not use a welding power source for pipe thawing.

Page 5: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

ivSAFETYiv

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissent dans cemanuel aussi bien que les précautions de sûreté générales suiv-antes:

Sûreté Pour Soudage A LʼArc1. Protegez-vous contre la secousse électrique:

a. Les circuits à lʼélectrode et à la piéce sont sous tensionquand la machine à souder est en marche. Eviter toujourstout contact entre les parties sous tension et la peau nueou les vétements mouillés. Porter des gants secs et sanstrous pour isoler les mains.

b. Faire trés attention de bien sʼisoler de la masse quand onsoude dans des endroits humides, ou sur un planchermetallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grandepartie du corps peut être en contact avec la masse.

c. Maintenir le porte-électrode, la pince de masse, le câblede soudage et la machine à souder en bon et sûr étatdefonctionnement.

d.Ne jamais plonger le porte-électrode dans lʼeau pour lerefroidir.

e. Ne jamais toucher simultanément les parties sous tensiondes porte-électrodes connectés à deux machines à souderparce que la tension entre les deux pinces peut être letotal de la tension à vide des deux machines.

f. Si on utilise la machine à souder comme une source decourant pour soudage semi-automatique, ces precautionspour le porte-électrode sʼapplicuent aussi au pistolet desoudage.

2. Dans le cas de travail au dessus du niveau du sol, se protégercontre les chutes dans le cas ou on recoit un choc. Ne jamaisenrouler le câble-électrode autour de nʼimporte quelle partiedu corps.

3. Un coup dʼarc peut être plus sévère quʼun coup de soliel,donc:

a. Utiliser un bon masque avec un verre filtrant appropriéainsi quʼun verre blanc afin de se protéger les yeux du ray-onnement de lʼarc et des projections quand on soude ouquand on regarde lʼarc.

b. Porter des vêtements convenables afin de protéger lapeau de soudeur et des aides contre le rayonnement delʻarc.

c. Protéger lʼautre personnel travaillant à proximité ausoudage à lʼaide dʼécrans appropriés et non-inflammables.

4. Des gouttes de laitier en fusion sont émises de lʼarc desoudage. Se protéger avec des vêtements de protection libresde lʼhuile, tels que les gants en cuir, chemise épaisse, pan-talons sans revers, et chaussures montantes.

5. Toujours porter des lunettes de sécurité dans la zone desoudage. Utiliser des lunettes avec écrans lateraux dans leszones où lʼon pique le laitier.

6. Eloigner les matériaux inflammables ou les recouvrir afin deprévenir tout risque dʼincendie dû aux étincelles.

7. Quand on ne soude pas, poser la pince à une endroit isolé dela masse. Un court-circuit accidental peut provoquer unéchauffement et un risque dʼincendie.

8. Sʼassurer que la masse est connectée le plus prés possiblede la zone de travail quʼil est pratique de le faire. Si on placela masse sur la charpente de la construction ou dʼautresendroits éloignés de la zone de travail, on augmente le risquede voir passer le courant de soudage par les chaines de lev-age, câbles de grue, ou autres circuits. Cela peut provoquerdes risques dʼincendie ou dʼechauffement des chaines et descâbles jusquʼà ce quʼils se rompent.

9. Assurer une ventilation suffisante dans la zone de soudage.Ceci est particuliérement important pour le soudage de tôlesgalvanisées plombées, ou cadmiées ou tout autre métal quiproduit des fumeés toxiques.

10. Ne pas souder en présence de vapeurs de chlore provenantdʼopérations de dégraissage, nettoyage ou pistolage. Lachaleur ou les rayons de lʼarc peuvent réagir avec les vapeursdu solvant pour produire du phosgéne (gas fortement toxique)ou autres produits irritants.

11. Pour obtenir de plus amples renseignements sur la sûreté,voir le code “Code for safety in welding and cutting” CSAStandard W 117.2-1974.

PRÉCAUTIONS DE SÛRETÉ POURLES MACHINES À SOUDER ÀTRANSFORMATEUR ET ÀREDRESSEUR

1. Relier à la terre le chassis du poste conformement au code delʼélectricité et aux recommendations du fabricant. Le dispositifde montage ou la piece à souder doit être branché à unebonne mise à la terre.

2. Autant que possible, Iʼinstallation et lʼentretien du poste seronteffectués par un électricien qualifié.

3. Avant de faires des travaux à lʼinterieur de poste, la debranch-er à lʼinterrupteur à la boite de fusibles.

4. Garder tous les couvercles et dispositifs de sûreté à leurplace.

Mar. ʻ93

Page 6: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

vv

TThhaannkk YYoouu for selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much pride as we have in bringing this product to you!

Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep ithandy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.The level of seriousness to be applied to each is explained below:

WARNINGThis statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.

This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.CAUTION

Please Examine Carton and Equipment For Damage ImmediatelyWhen this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claimsfor material damaged in shipment must be made by the purchaser against the transportation company at thetime the shipment is received.

Please record your equipment identification information below for future reference. This information can befound on your machine nameplate.

Product _________________________________________________________________________________Model Number ___________________________________________________________________________Code Number or Date Code_________________________________________________________________Serial Number____________________________________________________________________________Date Purchased___________________________________________________________________________Where Purchased_________________________________________________________________________Whenever you request replacement parts or information on this equipment, always supply the information youhave recorded above. The code number is especially important when identifying the correct replacement parts.

On-Line Product Registration- Register your machine with Lincoln Electric either via fax or over the Internet.

• For faxing: Complete the form on the back of the warranty statement included in the literature packetaccompanying this machine and fax the form per the instructions printed on it.

• For On-Line Registration: Go to our WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then“Product Registration”. Please complete the form and submit your registration.

CUSTOMER ASSISTANCE POLICYThe business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask LincolnElectric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose,with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating orcorrecting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter anywarranty with respect to the sale of our products.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the controlof, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained inapplying these types of fabrication methods and service requirements.

Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.comfor any updated information.

Page 7: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

vi vi TABLE OF CONTENTSPage

Installation .......................................................................................................Section ATechnical Specifications ........................................................................................A-1

Physical Dimensions .......................................................................................A-2Safety Precautions ..........................................................................................A-3Select Suitable Location..................................................................................A-3Stacking ..........................................................................................................A-3Tilting...............................................................................................................A-3 Input and Grounding Connections ..................................................................A-3Power Cord Connection ..................................................................................A-3Connection of Wire Feeders to V350-PRO .............................................A-3,A-4Remote Control of Invertec .............................................................................A-5Undercarriage Mountings................................................................................A-5Parallel Operations..........................................................................................A-5

________________________________________________________________________

Operation .........................................................................................................Section BSafety Precautions ................................................................................................B-1General Description ..............................................................................................B-1Duty Cycle .............................................................................................................B-1Operational Features and Controls........................................................................B-1 Upper Control Panel.......................................................................................B-1, B-2Hidden Middle Control Panel and Advance Process Panel .....................B-2 thru B-5Weld Mode Details and Pulse Programs ........................................................B-6,B-7Lower Case Panel .................................................................................................B-8Remote Control of the Output Control and Weld Terminals ..................................B-8Auxiliary Power ......................................................................................................B-9Limitations..............................................................................................................B-9Recommended Processes ....................................................................................B-9

_______________________________________________________________________

Accessories .....................................................................................................Section COptions / Accessories............................................................................................C-1Construction Version .............................................................................................C-1Factory and Advance Process Version ..............................................................................C-1Field Installed Options...........................................................................................C-1Quick Disconnect Plugs.........................................................................................C-1

________________________________________________________________________

Maintenance ....................................................................................................Section DSafety Precautions ................................................................................................D-1CAPACITOR DISCHARGE PROCEDURE..........................................................................D-1VISUAL INSPECTION...................................................................................................D-1ROUTINE MAINTENANCE ............................................................................................D-1PERIODIC MAINTENANCE ...........................................................................................D-1

________________________________________________________________________

Section E ..............................................................................................TroubleshootingSafety Precautions.................................................................................................E-1How to Use Troubleshooting Guide.......................................................................E-1Troubleshooting Guide ...........................................................................E-2 Thru E-3Fault Codes ...........................................................................................................E-4Displays .................................................................................................................E-5

________________________________________________________________________

Connection , Wiring Diagrams and Dimension Prints .................................Section F________________________________________________________________________

Parts List .....................................................................................................P-401 Series________________________________________________________________________

Page 8: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

INVERTEC® V350-PRO

A-1INSTALLATION A-1

TECHNICAL SPECIFICATIONS - INVERTEC V350-PROINPUT AT RATED OUTPUT

Input AC Rated DC Output Output Open Voltage Amps/Volt Range Circuit

/Duty Cycle (continuous) Voltage

220000220088--223300// 335500AA // 3344VV // 6600%% AAMMPPSS 8800 VVDDCC338800--440000// 330000AA // 3322VV //110000%% 55--442255441155--446600//557755

Voltage

200

208230380

400

415460575

200208230380400415460575

Phases

1

111

1

111

33333333

Input Amps300Amps @

32Volts(100%)Not

Recommended7669Not

RecommendedNot

Recommended413631

4139362322221916

Input Amps350Amps @34Volts(60%)

NotRecommended

9485Not

RecommendedNot

Recommended544237

5050422827262318

Line CordAWG

---

24---

---

688

66888888

MaximumFuse size

---

125A125A

---

---

80A70A50A

80A80A70A50A50A50A50A35A

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine OutputsInput 50/60 Hz Recommended

Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate.Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

Select The output cable size based upon the following chart.Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE100%60%

CURRENT300350

LENGTH UP TO 200FT.(61m)1/01/0

200-250 FT. (61-76m)1/02/0

Notes

Note 1

Note 2Note 2Note 1

Note 1

Note 2

Note 2Note 2

ProductName

IInnvveerrtteeccVV335500--PPRROO6600//5500 HHzz

11 && 33PPhhaassee

Page 9: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

A-2INSTALLATION

INVERTEC® V350-PRO

A-2

* Overall Length Including Handle, 27.8” (706mm)

Height Width Depth Weight with Cord Constructionand Factory 14.8”(373mm) 13.3”(338mm) 27.8” *(706mm*) 81.0 Lbs.(36.7 Kg)

AdvancedProcess 14.8”(373mm) 13.3”(338mm) 27.8” *(706mm*) 81.5 Lbs.(37.0 Kg)and Rack

PHYSICAL DIMENSIONS

TEMPERATURE RANGESSTORAGE TEMPERATURE RANGE

-40°C to +40°COPERATING TEMPERATURE RANGE

-20°C to +40°C

Page 10: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

A-3INSTALLATION A-3

SELECT SUITABLE LOCATIONThe Invertec V350-PRO will operate in harsh environments.Even so, it is important that simple preventative measuresare followed in order to assure long life and reliable opera-tion.• The machine must be located where there is free circula-

tion of clean air such that air movement in the back, outthe sides and bottom will not be restricted.

• Dirt and dust that can be drawn into the machine should bekept to a minimum. Failure to observe these precautionscan result in excessive operating temperatures and nui-sance shutdown.

• Keep machine dry. Shelter from rain and snow. Do notplace on wet ground or in puddles.

• DO NOT MOUNT OVER COMBUSTIBLE SURFACES.Where there is a combustible surface directly understationary or fixed electrical equipment, that surfaceshall be covered with a steel plate at least .06”(1.6mm)thick, which shall extend not less than 5.90”(150mm)beyond the equipment on all sides.-------------------------------------------------------------------------------STACKINGV350-PRO cannot be stacked.

TILTINGPlace the machine directly on a secure, level surface or on arecommended undercarriage. The machine may topple overif this procedure is not followed.INPUT AND GROUNDING CONNECTIONS• Only a qualified electrician should connect the Invertec

V350-PRO. Installation should be made in accordancewith the appropriate National Electrical Code, all localcodes and the information detailed below.

• When received directly from the factory, multiple voltagemachines are internally connected for 460VAC. If 460VACis the desired input, then the machine may be connectedto the power system without any setup required inside themachine.

• Initial 200VAC - 415VAC and 575VAC operation willrequire an Input voltage panel setup.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• TURN THE INPUT POWER OFF AT THE DISCONNECT SWITCH BEFOREATTEMPTING TO CONNECT OR DIS-

CONNECT INPUT POWER LINES, OUTPUTCABLES, OR CONTROL CABLES.

• Only qualified personnel should perform thisinstallation.

• Connect the green/yellow lead of the powercord to ground per U.S.National ElectricalCode.

----------------------------------------------------------------------

WARNING• Open the access panel on the rear of the machine.• For 200 or 230: Position the large switch to 200-

230.For higher voltages: Position the large switch to380-575.

• Move the "A" lead to the appropriate terminal.

POWER CORD CONNECTIONA 10 ft. power cord is provided and wired into themachine. Follow the power cord connection instruc-tions.

• Incorrect connection may result in equipmentdamage.

-----------------------------------------------------------------------

Single Phase InputConnect green lead to ground per National ElectricalCode.Connect black and white or brown leads to power.Wrap red lead with tape to provide 600V insulation.Three Phase InputConnect green lead to ground per National ElectricCode.Connect black, red and white or brown leads topower.

CONNECTIONS OF WIRE FEEDERS TO V350-PRO LN-7 Connection InstructionsAn LN-7 can only be used with the “Factory” &“Advanced Process”” versions of the 350-Pro. • Turn the Invertec power switch "off".• Connect the K480 control cable from the LN-7 to the

14-pin MS-style connector.• Connect the electrode cable to the output terminal of

the polarity required by electrode. Connect the worklead to the other terminal.

• Set the meter polarity switch on the front of the Invertecto coincide with wire feeder polarity used. The wirefeeder will now display the welding voltage.

• If K480 is not available, see connection diagramS19404 for modification of K291 or K404 LN-7 inputcable with K867 Universal Adapter Plug.

• If a remote control such as K857 is to be used with theLN-7, the remote can be connected directly to the 6-pinMS-style connector on the front of the Invertec or use aK864 adapter to connect the LN-7 and the remote tothe 14-pin MS-style connector. (See connection dia-gram S19901)

WARNING

REMOTE

POWER

OFF

ON

A AMPS

A

V VOLTS

WELD TERMINALS

SELECT

OUTPUTLINCOLNELECTRIC

INVERTEC V350-PRO

WARNINGWARNING

AVISO DEPRECAUCION

ATTENTION

!

!

!

!

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

Lorem ipsum dolor sit amet consectetuer adipiscing

Lorem ipsum dolor sit amet consectetuer adipiscing

elit, ed diam nonummy nibh euismod tincidunt ut

elit, ed diam nonummy nibh euismod tincidunt ut

laoreet dolore magna aliquam erat

laoreet dolore magna aliquam erat

GREENRED

BLACK

WHITE or BROWN

INVERTEC® V350-PRO

CAUTION

CAUTION

Page 11: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

A-4INSTALLATION A-4LN-10 Connection InstructionsAn LN-10 can only be used with the “Factory” &“Advanced Process”” versions of the 350-Pro.• Turn the Invertec power switch "off"• Connect the K1505 control cable from the LN-10 to the

14-pin MS-style connector.• Connect the electrode cable to the output terminal of

polarity required by the electrode. Connect the worklead to the other terminal.

• Set the meter polarity switch on the front of the Invertecto coincide with wire feeder polarity used.

• See the LN-10 manual for details on accessing ControlDIP Switch

LN-15 Connection Instructions (Factory, Construction & Advanced Process versionscan be connected.• Turn the Invertec power switch "off".• Connect the electrode cable to the output terminal of

polarity required by electrode. (See Figures below)

• Set the meter polarity switch on the front of the Invertecto coincide with wire feeder polarity used.

LN-25 Connection Instructions (Factory, Construction & Advanced Process versionscan be connected.• Turn the Invertec power switch "off".• Connect the electrode cable to the output terminal of

polarity required by electrode. Connect the work lead tothe other terminal.

• LN-25 with Remote Control options can be used with theFactory and Advanced Process version of the V350. The6-Pin (K444-1) and 14-pin (K444-2) remotes can be con-nected directly to the 6-pin & 14-pin MS-style connectors.The 42 Volt Remote Voltage and Output Control (K624-1)Kit can be connected to the V350ʼs 14-pin MS-style con-nector using Remote Control Cable assembly K627- [ ].LN-25s with a K431-1 remote kit can be connected to theV350ʼs 14-pin MS-style connector using a K432 cable andK876 adapter. (See connection diagram S19899). Or theK432 cable could be modified with a K867 UniversalAdapter Plug (See connection diagram S19405) to con-nect it to the V350ʼs 14-pin MS-style connector.

LN-742 Connection InstructionsAn LN-742 can only be used with the “Factory” &“Advanced Process”” versions of the 350-Pro.• Turn the Invertec power switch "off"• Either a K591 or a K593 Input cable assembly is

required to connect the LN-742 to the Invertec. • Connect the control cable from the LN-742 to the

14-pin MS-style connector.• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect thework lead to the other terminal.

• Set the meter polarity switch on the front of theInvertec to coincide with wire feeder polarity used.The wire feeder will now display the welding volt-age.

• If a remote control such as K857 is to be used with theLN-742, the remote can be connected directly to the 6-pin MS-style connector on the front of the Invertec or usea K864 adapter to connect the LN-742 and the remote tothe 14-pin MS-style connector.

Cobramatic Connection InstructionsA Cobramatic can only be used with the “Factory” &“Advanced Process”” versions of the 350-Pro.• Turn the Invertec power switch "off"• Connect the control cable from the Cobramatic to

the 14-pin MS-style connector.• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect thework lead to the other terminal.

• Set the meter polarity switch on the front of theInvertec to coincide with wire feeder polarity used.

• If a remote control such as K857 is to be used withthe Cobramatic, the remote can be connecteddirectly to the 6-pin MS-style connector on the frontof the Invertec or use a K864 adapter to connectthe cobramatic and the remote to the 14-pin MS-style connector.

TIG Module K930-2The TIG Module connects to the Factory and AdvancedProcess V350-Pro versions with a K936-1 (9-14 pin)control cable. Connect the K936-1 to the MS-styleconnector.

The TIG Module can also be used with the V350-ProConstruction version. A K936-4 control cable isrequired to supply 115VAC to the TIG Module froman external 115VAC supply.

INVERTEC® V350-PRO

WorkClamp

Electrode Cable

Electrode Cable

Electrode Cable

WorkClamp

WorkClamp

wire feederK1870-1wire feederK1870-1

RANGER 8SAE 400 WITH CV ADAPTER

ENGINE DRIVEN WELDERSWITH WIRE FEED MODULE(LOCAL MODE AND CV ADAPTER)

CV250CV300CV400

CC POWER SOURCE

Output TerminalsAlways Hot.

Output TerminalsAlways Hot.

Output TerminalsAlways Hot.

Order K484 JumperPlug Kit.

Electrode CableWorkClamp

semiautomatic

semiautomatic

semiautomatic

semiautomaticwire feederK1870-1

wire feederK1870-1

wire feederK1870-1

CV655, DC400, DC600,DC655, V350-PRO,

RANGER 9, RANGER 300 DLXCOMMANDER 300COMMANDER 500RANGER 2V35050RANGER 305G

Output TerminalsOutput TerminalsAlways Hot.Always Hot.

Power source contactorPower source contactorswitch must be in theswitch must be in the "ON" position or use a "ON" position or use aK848 Junper Plug Kit.K848 Junper Plug Kit.

ACROSS THE ARC MODEL

V350-PRO

TWIST-MATE

CONTROL CABLE MODEL

Electrode Cable

Page 12: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

A-5INSTALLATION A-5

INVERTEC® V350-PRO

General Instructions for Connection of WireFeeders to V350-ProWire feeders other than those listed above may beused provided that the auxiliary power supply rating ofthe V350-Pro is not exceeded. K867 universal adapterplug is required. See connection diagram S24985 onpage F-4.

REMOTE CONTROL OF INVERTECRemote Control K857, Hand Amptrol K963 and FootAmptrol K870.

UNDERCARRIAGE MOUNTINGS

PARALLEL OPERATIONThe V350-Pro are operable in parallel in CC mode.For best results, the currents of each machine shouldbe reasonably equally balanced. As an example, withtwo machines set up in parallel for a 400 amp proce-dure, each machine should be set to deliver approxi-mately 200 amps, not 300 amps from one and 100amps from the other. This will minimize nuisanceshutdown conditions. In general, more than twomachines in parallel will not be effective due to thevoltage requirements of procedures in that powerrange.

To set machine outputs, start with output control potsand arc control pots in identical positions. Use theoutput control pots to balance the currents and main-tain the desired current. The arc control pots shouldbe kept identical on the two machines.

M195276-01

14.79

12.44

3.44 21.06

27.82

5.50

10.00

MOUNTING HOLE LOCATIONS

13.10

1/4-20 NUT (4 PLACES)

NOTE: MOUNTING SCREWS CANNOT PROTRUDE MORE THAN 0.5 INCHES INSIDE THE MACHINE.

3.50

11.84

Page 13: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-1OPERATION

INVERTEC® V350-PRO

B-1SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.• Do not touch electrically live parts orelectrode with skin or wet clothing.• Insulate yourself from work andground.• Always wear dry insulating gloves.

------------------------------------------------------------------------FUMES AND GASES can be danger-ous.• Keep your head out of fumes.• Use ventilation or exhaust to removefumes from breathing zone.

------------------------------------------------------------------------WELDING SPARKS can cause fire orexplosion.• Keep flammable material away.• Do not weld on closed containers.

------------------------------------------------------------------------ARC RAYS can burn eyes and skin.• Wear eye, ear and body protection.

------------------------------------------------------------See additional warning information atfront of this operatorʼs manual.

-----------------------------------------------------------

WARNING

GENERAL DESCRIPTIONThe Invertec V350-Pro offers multi-process CV, CC,and DC welding and is rated 350 amps, 34 volts at a60% duty cycle. The V350-Pro is available in either aConstruction version (no wire feeder connection andauxiliary power) and a Factory & Advance Processversions (includes wire feeder connection and relatedpower)• The factory model is the construction model with the

addition of the Wire Feeder/Remote Adapter.

• In this form, the V350-Pro provides the hardware topower and connect to 24, 42 or 115 VAC wire feeders.

• The advanced process model is the factory modelwith an advanced process panel installed in place ofthe standard mode panel. In this form, the V350-Proprovides access to the 5 standard weld modes (StickSoft, Stick Crisp, TIG, CV-Wire, CV-Innershield),gouge, constant power and pulse MIG weld modes.

• The Factory Rack model is the Factory model addedwith environmental protection and input power fea-tures compatible with inverter racks sold by LincolnElectric Company.

DUTY CYCLE

The V350-Pro is rated at 350 amps, 60% duty cycle(based on a 10 minute cycle). It is also rated at 300amps, 100% duty cycle.

OPERATIONAL FEATURES and CONTROLS:UPPER CONTROL PANEL1. AMPS Meter• Prior to STICK or TIG operation (current flow), the

meter displays preset current value (either 2 ampsor +/- 3% (e.g. 3 amps on 100), whichever isgreater).

• Prior to CV operation, the meter displays four dash-es indicating non-presettable AMPS.

• During welding, this meter displays actual averageamps.

• After welding, the meter holds the actual currentvalue for 5 seconds. Output adjustment while in the"hold" period results in the "prior to operation" char-acteristics stated above. The displays blink indicat-ing that the machine is in the "Hold" period.

2. VOLT METER• Prior to CV operation (current flow), the meter dis-

plays desired preset voltage value (+/- .5V).• Prior to STICK or TIG operation, the meter displays

the Open Circuit Voltage of the Power Source orfour dashes if the output has not been turned on.

• During welding, this meter displays actual averagevolts.

• After welding, the meter holds the actual voltagevalue for 5 seconds. The displays blink indicatingthat the machine is in the "Hold" period.

• Output adjustment while in the "hold" period resultsin the "prior to operation" characteristics statedabove.

3. OUTPUT CONTROL• Output control is conducted via a single turn poten-

tiometer. • Adjustment is indicated by the meters as stated

above. • When in TIG modes, this control sets the maximum

welding current. Full depression of a foot or handAmptrol results in the preset level of current.

4. WELD TERMINALS-REMOTE / ON• Two status lights indicate the location of trigger con-

trol as determined by the "WELD TERMINALS"push button.

• If trigger control is local "weld terminals on", the ONdisplay will be lit.

• If trigger control is remote "weld terminals remotelycontrolled", the REMOTE display will be lit.

• The unit will power up in "pre-determined preferred"trigger modes.

Page 14: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-2OPERATIONB-2STICK = ON CV = REMOTETIG = REMOTE if remote output controls areattached to the machine.TIG = 0N if remote output controls are not attached tothe machine.For all versions, these trigger modes can be over-ridden(switched) with the WELD TERMINALS push button. Whenchanged, the unit will power up in the configuration it was inwhen it was last powered down.

5. THERMAL• This status light indicates when the power source has

been driven into thermal overload. If the output terminalswere "ON", the "ON" light will blink indicating that the out-put will be turned back on once the unit cools down to anacceptable temperature level. If the unit was operating inthe "REMOTE" mode, the trigger will need to be openedbefore or after the thermal has cleared and closed afterthe machine has cooled down to an acceptable tempera-ture to establish output.

6. CONTROL-REMOTE / LOCAL• Two status lights indicate the location of output control as

pre-determined by the power sources auto-configure sys-tem.

• The LOCAL display will be lit when control is at the powersource.

• The REMOTE display will be lit when a remote pot/controlis detected.

These Output Control configurations can be overridden(switched) with the CONTROL push button. Whenchanged, the unit will power up in the configuration it was inwhen it was last powered down.

Hidden Middle Control Panel – Process Set UpPanel

The middle control panel is removable to allow forupgrades (see Field Installed Options/Accessories).Additionally, this panel is hidden by an access door toreduce appeared complexity and provide protection tothe controls.

7. WELD MODE SELECT - FACTORY AND CONSTRUCTION (See Figure 1)

The Mode Control button selects from the followingwelding modes.

CC-STICK SOFT: The Stick Soft process featurescontinuous control ranging from 5 to 425 amps. Thismode was intended for most SMAW applications, andArc Gouging.

• Arc Gouging: Setting the output of the Stick Softmode to 425 amps and/or setting the arc control to9.5 or above will enable the arc-gouging mode. Theactual output current will depend on the size of car-bon used. The recommended maximum size carbonis 5/16"(7.9mm).

• The Hot Start control regulates the starting currentat arc initiation. Hot Start can be adjusted from min-imum (0), with no additional current added at arcstart, to maximum (10), with double the preset cur-rent or 425 amps (max of machine) added for thefirst second after arc initiation.

• The Arc Control regulates the Arc Force to adjustthe short circuit current. The minimum setting (-10)will produce a "soft" arc and will produce minimalspatter. The maximum setting (+10) will produce a"crisp" arc and will minimize electrode sticking.

CC-STICK CRISP:The Stick Crisp mode featurescontinuous control from 5 to 425 amps. This modewas intended primarily for pipe welding applications.

• The Hot Start control regulates the starting currentat arc initiation. Hot Start can adjust starting currentup or down by 25% of the preset value. The recom-mended setting for Hot Start is 5 where the initialcurrent is equal to the preset current.

• Arc Gouging: Setting the output of the stick crispmode to 425 amps and/or setting the arc control to9.5 or above will enable the arc-gouging mode. Theactual output current will depend on the size of car-bon used. The recommended maximum size car-bon is 5/16”(7.9mm)

INVERTEC® V350-PRO

REMOTEREMOTEONON

REMOTEREMOTELOCALLOCAL

WELD TERMINALSWELD TERMINALS

OUTPUTOUTPUT

CONTROLCONTROL

SELECTSELECT SELECTSELECT

MPSMPSAA OLTSOLTSVV

SELECTSELECT

CC-STICK SOFT 7018CC-STICK SOFT 7018

CC-STICK CRISP 6010CC-STICK CRISP 6010

TIG GTAWTIG GTAW

CV-WIRECV-WIRE

CV-FLUX COREDCV-FLUX CORED

HOT STARTHOT START ARC CONTROLARC CONTROL

-4-4 +4+4+2+2-2-2 00

-6-6 +6+6

-10-10SOFTSOFT CRISPCRISP

+10+10

-8-8 +8+8

5544

33

22

1100

66

1010

99

88

77

1

65

2

3

4

8

7

11

1012 9

FIGURE 1

Page 15: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-3OPERATIONB-3• The Arc Control regulates the Arc Force to adjust

the short circuit current. The minimum setting (-10)will produce a "soft" arc and will produce minimalspatter. The maximum setting (+10) will produce a"crisp" arc and will minimize electrode sticking.

TIG GTAW: The TIG mode features continuous con-trol from 5 to 425 amps. The TIG mode can be run ineither the TIG touch start or high frequency (optionalequipment required) assisted start mode.• The Hot Start control selects the starting mode

desired. A setting of less than 5, the TIG lift startmode is selected. The OCV is controlled below 10vand the short circuit "TIG touch" current is main-tained at 25 amps independent of the preset cur-rent.When the tungsten is lifted, an arc is initiated andthe output is regulated at the preset value. Hot startsettings between 0 and 5 regulate the arc initiationcurrent. A setting of 5 results in the most positivearc initiation. A setting of 0 reduces hot start.

• Hot Start settings between 5 and 10, select highfrequency assisted starting TIG mode. In thisrange, the OCV of the machine is controlledbetween 50 and 70 volts. If using the Lincoln K930-1 TIG Module, set the Hot start to 10 for maximumOCV.

• The Arc Control is not used in the TIG mode.

TIG SOLENOID OPTION

The Solenoid only operates when th V350 is in theTIG mode. If the Weld Terminals are in “Remote” thenthe solenoid will open when the arc start switch isclosed. The solenoid will close after the arc switch hasbeen opened and the post flow time expired.

If the Weld Terminals are turned “ON”, then the sole-noid will open when the electrode is touch to the work.The electrode needs to remain in contact with thework to allow for gas coverage before attempting tostart the arc. The solenoid will close after the arc hasbeen broken and the post flow time expired.

CV-WIRE: The CV-WIRE mode features continuouscontrol from 10 to 40 volts. The mode was intendedfor most GMAW, FCAW, and MCAW applications.

• The Hot Start control is not used in the CV-WIREmode.

• The Arc Control regulates pinch effect. At the mini-mum setting (-10), minimizes pinch and results in asoft arc. Low pinch settings are preferable for weld-ing with gas mixes containing mostly inert gases. Atthe maximum setting (+10), maximizes pinch effectand results in a crisp arc. High pinch settings arepreferable for welding FCAW and GMAW with CO2.

INVERTEC® V350-PRO

CV-INNERSHIELD: The CV-INNERSHIELD modefeatures continuous control from 10 to 45 volts. Thismode was designed for self-shielded flux cored wiresthat require tight voltage control.

• The Hot Start control is not used in the CV-INNER-SHIELD mode.

• The Arc Control regulates pinch effect. At the mini-mum setting (-10), minimizes pinch and results in asoft arc. At the maximum setting (+10), maximizespinch effect and results in a crisp arc. Most self-shielded wires work well at an Arc Control setting of 5.

Page 16: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-4OPERATIONB-47A. ADVANCED PROCESS PANEL

(See Figure 2)

To program Welding modes. Select knob is used toScroll through all Welding modes. The Memory buttonis used to store and access Welding modes into loca-tions M1 thru M8.

Modes:In addition to the 5 welding modes described in SEC-TION 7, the Advance Process Panel allows you toselect the Following additional modes.

• Constant Power modeIn the Power Mode;The work point will be in the Volts window. TheAmp window will have CP displayed indicatingConstant Power. Once current starts flowing andduring the 5 second “Hold” feature the displays willshow Volts and Amps respectively.

• GougeAir Carbon Arc Cutting (CAC-A) is a physical meansof removing base metal or weld metal by using acarbon electrode, an electric arc and compressedair.

INVERTEC® V350-PRO

• Pulsed ModesIn Pulse Modes;The work point will be in the Amps window andshould be set close to the wire feed speed of thewire feeder in inches per minute. The Volts windowwill have SPd displayed indicating Wire FeedSpeed. Once current starts flowing and during the 5second “Hold” feature the displays will show ampsand volts.

Pulse Mode features that are displayed whileselecting a Welding pulse mode are listed below;Steel - .030, .035, .045, .052 – Argon Blends Stainless Steel - .030, .035, .045 – Argon Blends &Helium/Argon Blends Aluminum - .035, 3/64, 1/16 – 4043 & 5356 Metal Core - .045, .052 – Argon Blends Nickel - .035, .045 – Argon/Helium blends

MEMORYMEMORY

MEMORY BUTTON MEMORY BUTTON (M1 THRU M8)(M1 THRU M8)

OUTPUT KNOBOUTPUT KNOB

SELECT BUTTONSELECT BUTTON(HOT START OR ARC CONTROL)(HOT START OR ARC CONTROL)

ADJUST KNOBADJUST KNOB(0 THRU 10-HOT START)(0 THRU 10-HOT START)(-10 THRU 0 AND(-10 THRU 0 AND 0 THRU +10-ARC CONTROL) 0 THRU +10-ARC CONTROL) SELECT KNOB SELECT KNOB

(SCOLLS WELDING PROCESSES)(SCOLLS WELDING PROCESSES)

SELECTSELECT ADJUST ADJUST SELECTSELECT

7A

ADVANCE PROCESS PANEL VERSION

REMOTEREMOTEONON

REMOTEREMOTELOCALLOCAL

WELD TERMINALSWELD TERMINALS

OUTPUTOUTPUT

CONTROLCONTROL

SELECTSELECT SELECTSELECT

MPSMPSAA OLTSOLTSVV

FIGURE 2

Page 17: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-5OPERATIONB-5

INVERTEC® V350-PRO

CONTROLS: (See Figure 2)

The MEMORY button and SELECT knob are usedtogether to select a welding process and store it inmemory (M1 thru M8). The SELECT knob scrollsthrough the, welding process modes and memory M1thru M8. The MEMORY button stores the weldingprocess in memory.• SELECT button" (The right button) selects between

the "Hot Start" or "Arc Control". The < will indicatethe active feature shown below.

Right Digital Window"Hot Start" (-10 to 0 +10)"Arc Control" (0 to 10) <

• The ADJUST knob adjusts the desired settings forthe Hot Start or Arc Control feature that is active.

WELDING PROCESS MODES AVAILABLE

Stick SMAW, TIG GTAWGouge CAG, CV MIG GMAWCV Flux Core, Pulse MIG

ELECTRODE MATERIAL

Steel, Metal Core, Stainless, Aluminum, Nickel

EXAMPLE OF SAVING WELDING MODES TOMEMORY

The following example is how to select Pulse MIGusing .035 steel and store it into memory.

1. Turn the Select knob until welding process is dis-played.

RIGHT WINDOW LEFT WINDOWPulse MIG Argon BlendsSteel .035

2. Wait two seconds and the right window will displayArc Control on the second line on the right side.

Pulse MIG Argon BlendsSteel .035 Arc Cntrl ### <

3. SPd is displayed in the upper right Volts window.The left Amps window matches the desired wirefeed speed that is set on the wire feeder. Adjust theOutput knob until desired number is displayed.

4. Start welding. If the arc length is too short turn theOutput knob up. If the arc length is too long turnthe Output knob down.

The Arc Control which is displayed in the right digitalwindow can be used to fine-tune the arc length andcharacteristics.

5. After all adjustments have been made press andhold the Memory button until the display changes.The right and the left window will display a memoryposition, lets say M1(or turn knob to select memoryof your choice. To store in M1 push the Memorybutton again to save the Pulse Mig mode to memo-ry M1.

6. The display in the digital windows read as follows:M1 Pulse MIG Argon Blends

Steel .035 Arc Cntrl 1.2

7. To save a second welding mode to a memory posi-tion of your choice, turn the Select knob until thedesired welding process mode is displayed in rightdigital window. Then follow steps 1 thru 6.

8. Adjust the output control to the correct wire feedsetting and the V350-PRO is ready to weld again.(Note: The wire feed speed setting is not stored inmemory and will need to be reset.)

9. Adjust the Arc Control and note that the M1 goesaway indicating that the V350-PRO settings nolonger match what is stored in memory. Going backto the original settings will not bring the M1 back.You will need to push the Memory button to recallthe original settings in M1.

Note: After all memoryʼs M1 thru M8 are used and thewelder needs to store another welding process, a newwelding process will overwrite what was originally inthe memory and will read,

Save to MEMM1 Overwrite

M1 which stored Pulse Mig is Overwritten with thenew welding process.

Page 18: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-6OPERATIONB-6WELD MODE DETAILS:

INVERTEC® V350-PRO

Mode Range Comments

Stick Soft 5 - 425 amps The stick soft mode is the best selection for general stick applications.Arc Control = Arc ForceHot Start = Initial hot start current (min = start a match set amps, Max. =

greatest hot start current) During hot start, arc force is set athigh and is fast response.

For gouging applications: Turn current up to 425 amps.

Stick Crisp 5 - 425 amps The stick crisp mode features an aggressive arc force routine well suit-ed for Exx10, Exx11 series electrodes.Arc Control = Arc ForceHot Start = Initial hot start current (Mid range = welding current and will

vary up and down with knob control.) During hot start, arcforce is set at high and is fast response.

For gouging applications: Turn current up to 425 amps.

GTAW (Tig mode) 5 - 425 amps The tig mode produces a soft, steady constant current waveform foreither touch start or high frequency assisted start DC GTAW applica-tions.Hot Start = Min to Mid range = Touch start with low OCVMid to Max range = High frequency assisted starting with adjustableOCV up to 70 volts.

GMAW - CV 10 - 45 volts The GMAW - CV mode is the best selection for general MIG welding, Metal core, and gas shielded applications.Arc Control = Pinch (Min = min pinch, softest arc),

(Max = max pinch, crispest arc)

FCAW-SS 10 - 45 volts The FCAW-SS mode is designed for Self Shielded Innershield productsthat require tight voltage control. For example; the NR 203 series or NR207)Arc Control = Pinch (Min = min pinch, softest arc),

(Max = max pinch, crispest arc, )

ADVANCED PULSE PANEL WELDING PROGRAMS

Gouging 60 - 425 amps The gouging mode is a low power version of other Lincoln welding equipment gouging programs, for example a Power Wave 455.

GMAW - Power 1 - 18 (No Units) The GMAW - Power mode features good stable short arc performancewhen welding small diameter (.025 and .030 steel & stainless) wires atlow procedures. This mode also performs well welding aluminum in thespray mode.

This mode does not allow preset voltage. In the short arc GMAW mode,the set KW will not equal the actual Volts * Amps. The set power is reg-ulated only when an arc is present. During shorting, the output isallowed to increase to clear the short.

Page 19: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-7OPERATIONB-7PULSE PROGRAMS:

INVERTEC® V350-PRO

MODE IPM*.030 Steel 65 - 1200.035 Steel 55 - 800.045 Steel 50 - 700.052 Steel 75 - 550.045 Metal Core 50 - 650.052 Metal Core 50 - 500.030 Stainless Ar Blends 85 - 770.030 Stainless He Ar CO2 110 - 770.035 Stainless Ar Blends 65 - 770.035 Stainless He Ar CO2 75 - 770.045 Stainless Ar Blends 50 - 600.045 Stainless He Ar CO2 50 - 600.035 Aluminum 4043 100 - 700.035 Aluminum 5356 115 - 7403/64 Aluminum 4043 80 - 5503/64 Aluminum 5356 85 - 7001/16 Aluminum 4043 75 - 3251/16 Aluminum 5356 75 - 450

.035 Nickel Alloys (Non Adaptive) 80 - 700

.045 Nickel Alloys (Non Adaptive) 75 - 550

COMMENTSThe V350 pulse programs are non-synergic and allow independentcontrol of the wire feed speed and the arc length. The OutputControl Knob on the V350, adjusts an "SPD" value. Similar to trim,the "SPD" value indicates the relative arc length setting. The valueof "SPD" is meant to be a starting point at which to set the arclength relative to the wire feed speed. Depending on the applica-tion, the "SPD" value can be adjusted to obtain the desired arclength.

The "SPD" value displayed on the V350 may not match theactual wire feed speed!

The operation of the Arc Control knob on the V350 is similar to thePower Wave series. As Arc Control is increased, the frequency isincreased and the background reduced. Decreasing Arc Controlwill reduce frequency and increase background current. ArcControl acts to fine tune the arc plasma to the specific application. Preferred gas selections:

Steel Argon Blends = Argon with CO2 additions from 2 to 20% or Oxygen additions from 2 to 5%.

Stainless Argon Blends = Argon with Oxygen additions up to 2%Stainless Argon Blends = Argon with Oxygen additions up to 2%.

Stainless He Ar CO2 = ~ 90% Helium, 7 1/2 % Argon 2 1/2CO2Aluminum 100% Argon The Nickel Alloy pulse programs are non adaptive. The operatorsets the output control knob to deliver the correct arc length atdesired wire feed speed and stick out. While welding, the operatormanipulates the stick out to maintain the correct arc length. Thismethod of operation produces very stable arc performance consid-ering the nature of nickel alloys. Preferred gas: Argon/Helium Blends = for the best results addhelium to the argon base from 0-25%.

.035 4043 (4x Pulse on Pulse) 120 - 600 3/64 4043 (4x Pulse on Pulse) 85 - 400.035 5356 (5x Pulse on Pulse) 130 - 7003/64 5356 (5x Pulse on Pulse) 100 - 550

Arc Control = Pulse on Pulse frequency. For faster travel speed welds, the arc control should be increased. For larger puddle, slower travel speeds, the arc control should be decreased.

PULSE ON PULSE

*IPM (INCHES PER MINUTE)

Page 20: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-8OPERATIONB-8

INVERTEC® V350-PRO

LN-10/DH-10 Wire Feeder Compatibility Note:The LN-10 and DH-10 feeders can be used to pulse weldand in the power mode with the panel. The displays on theLN-10 & DH-10 do not show the wire feed speed or power.8. HOT START and ARC CONTROL features have different

functions depending on the welding Mode that is active.Each feature is described under the welding mode head-ing. (See Item 7 or 7.A for specified Mode Operations)(See Figure 1 or 2)LOWER CASE PANEL (See Figure 1)The output studs, line switch and remote connector arelocated on the lower case front.

9. Both terminals are "Twist-Mate" connectors. The Negative terminal is configured to accept the passthrough gas system except Code 11445, which has nogas pass-through and is equipped with “Tweco” connec-tors).

10. The METER POLARITY switch is located above the out-put connectors. The switch provides a work connectionfor wire feeder voltmeters. Place the switch in the posi-tion of the electrode polarity indicated by the decal. Theswitch does not change the welding polarity.

11. 6-pin MS-style connector for remote control.12. 14-pin MS-style connector for wire feeder connection

and remote control.

REMOTE CONTROL of the OUTPUT CONTROL andWELD TERMINALSThe Invertec V350-Pro has auto sensing of remote outputcontrols. If after connecting or removing a remote, theInvertec V350-Pro did not configure the way you would likethe local or remote control settings can be changed bypushing the OUTPUT CONTROL or WELD TERMINAL but-ton. (A user cannot select between the 6 and 14 pin MS-style connectors.)

CV modes• The remote will default to the 14-pin MS-style connector if

a remote is connected. If no remote is connected to the14-pin MS-style connector then the remote will default tothe 6-pin MS-style connector if a remote is connected to it.

• In all of the CV modes, the WELD TERMINAL control willdefault to REMOTE.

TIG mode• The remote will default to the 6-pin MS-style if a remote

control is connected to the 6-pin MS-style and to the 14-pin MS-style connector. If a remote is not connected to the6-pin MS-style connector then the remote will default tothe 14-pin MS-style connector if a remote is connected.

• If a remote control is connected to any of the MS-styleconnectors the WELD TERMINAL control will default toREMOTE. If there are not any remote control devicesattached the WELD TERMINAL control will default to ON.

CC-Stick modes • The remote will default to only the 6-pin MS-style connec-

tor if a remote is connected to it.• The WELD TERMINAL control will default to ON with or

without a remote connected.

Types of Remote OUTPUT CONTROL• The Invertec V350-Proʼs Output Control can be controlled

by either a potentiometer connected between 77 & 75 withthe wiper connected to 76 or a 0V to 10V DC supply con-nected between 76 & 75. (76 needs to be positive)

• 14-Pin Ms-style connector lead 75 is pin G, lead 76 is pinF and lead 77 is pin E.

• 6-Pin Ms-style connector lead 75 is pin C, lead 76 is pin Band lead 77 is pin A.

Potentiometer Control• The total resistance should be between 2000 ohms (2K)

and 10,000 ohms (10K)• The machine output will be at minimum when lead 76

(wiper) is at the end of the potentiometer that is connectedto 75. The machineʼs output will increase as the wiper ofthe potentiometer is moved to the end that is connected to77. (Note: In TIG mode, moving the lead 76 (wiper) to lead77 would produce the current that has been set by theInvertec V350-Proʼs front panel Output Control.)

• Remotes of this type offered by Lincoln Electric are theK857, K812 and K870.

Voltage Control• The supply should be an isolated supply. (Not referenced

to earth ground, any auxiliary power from the InvertecV350-Pro or the welding output) The supply should becapable of supplying at least 20mA.

• 0 volts supplied to 76 will set the Invertec V350-Pro tominimum output for the mode that has been selectedwhile 10 volts supplied to 76 will set the Invertec V350-Proto the maximum output for the mode. (Note: In TIG mode,10 volts supplied to lead 76 would produce the currentthat has been set by the Invertec V350-Proʼs front panelOutput Control.)

Types of Remote WELD TERMINAL Control• The Invertec V350-Proʼs Weld Terminals can be con-

trolled from each of the MS-style connectors. The circuithas a nominal OCV of 15VDC and requires a dry contactclosure (less than 100 ohms) to activate the output of theInvertec V350-Pro.

• 14-Pin MS-style connector, the Weld Terminals are con-trolled from pin C (lead 2) and pin D (lead 4). Pin C is posi-tive.

• 6-Pin MS-style connector, the Weld Terminals are con-trolled from pin D (lead 2) and pin E (lead 4). In the 6-pinMS-style connector pin D is positive.

Page 21: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

B-9OPERATIONB-9

INVERTEC® V350-PRO

AUXILIARY POWER• 115VAC, 42VAC and 24VAC power is available

from the 14-pin MS-style connector. TheConstruction model of the Invertec V350-Pro doesnot have the 14-pin MS-style connector) These sup-plies are intended to supply power for auxiliaryequipment like wire feeders and the TIG Module.

• 115VAC supply is rated at 2 amps and is protected by a3.5 amp breaker.

• 42 VAC supply is rated at 5.5 amps and is protectedby a 10 amp breaker.

• 24 VAC supply is rated at 5.5 amps and is protectedby a 10 amp breaker.

LIMITATIONS• The V350-Pro is not recommended for processes

other than those listed.• The V350-Pro can only be used with the recom-

mended equipment and options.

RECOMMENDED PROCESSESProperly equipped, the Invertec V350-Pro supportsGMAW-P, FCAW, SMAW, GTAW and CAC-Aprocesses for a variety of materials, including mildsteel, stainless steel, cored wires, and aluminum.

Page 22: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

C-1ACCESSORIESC-1OPTIONS / ACCESSORIES

• K2176-1 Twist-Mate to Lug Adapter• K1764-1 Inverter and Feeder Cart• K1557 Swivel Kit• K1702-1 Dual Cylinder Kit (For K1764-1)• K1838-1 Valet Style Undercarriage

Welding Cable Connectors:• K852-70 1/0-2/0 cable• K852-95 2/0-3/0 cable

Twist-Mate Plugs and Receptacles are not usedwith Code 11445.

CONSTRUCTION VERSIONK930-1 TIG Module (Requires external 115VAC supply)K428,K446, K449 LN-25(Off the Arc)

FACTORY VERSION andADVANCED PROCESS VERSION

K857 Remote Output ControlK814 Arc Start SwitchK812 Hand Operated AmptrolK870 Foot Operated Amptrol

Note: All of the above remote controls connect directlyto the 6-pin MS-style connector, with either a K864 orK876 adapter and connect it to the 14 pin wire feederMS-style connector. (See Diagram in Section F-1)

K930-[ ] TIG ModuleK428, K446, K449 LN-25 *K617 (-1 or -2) K618 (-1 or -2) LN-742K440 (-1), K567-1 LN-7 GMAK1559-1, K1564-1 LN-10K1499-1, K1521-1 DH-10K1587-1 Cobramatic

*Not recommended for pulse welding

FIELD INSTALLED OPTION (ALL VERSIONS)• K1762-2 TIG Gas Control Kit • K1763-1 Advanced Process Panel

INVERTEC® V350-PRO

QUICK DISCONNECT PLUGSA quick disconnect system is used for the weldingcable connections. The K852-70 is designed toaccept a welding cable size of 1/0 to 2/0.

1. Remove 25mm (1 in.) of welding cable insulation.

2. Slide rubber boot onto cable end. The boot endmay be trimmed to match the cable diameter.Soap or other lubricant will help to slide the bootover the cable.

3. Slide the copper tube into the brass plug.

4. Insert cable into copper tube.

5. Tighten set screw to collapse copper tube. Screwmust apply pressure against welding cable. Thetop of the set screw will be well below the surfaceof the brass plug after tightening.

6. Slide rubber boot over brass plug. The rubberboot must be positioned to completely cover allelectrical surfaces after the plug is locked into thereceptacle.

25 mm1 in.

WELDING CABLEBOOT

TRIM

SET SCREW

BRASS PLUGCOPPER TUBE

Page 23: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

D-1MAINTENANCED-1

VISUAL INSPECTIONClean interior of machine with a low pressure airstream. Make a thorough inspection of all compo-nents. Look for signs of overheating, broken leads orother obvious problems. Many problems can beuncovered with a good visual inspection.

ROUTINE MAINTENANCE1. Every 6 months or so the machine should be

cleaned with a low pressure airstream. Keepingthe machine clean will result in cooler operationand higher reliability. Be sure to clean these areas:

• All printed circuit boards• Power switch• Main transformer• Input rectifier • Auxiliary Transformer• Reconnect Switch Area• Fan (Blow air through the rear louvers)

2. Examine the sheet metal case for dents or breakage.Repair the case as required. Keep the case in good con-dition to insure that high voltage parts are protected andcorrect spacings are maintained. All external sheetmetal screws must be in place to insure case strengthand electrical ground continuity.

PERIODIC MAINTENANCEOverload ProtectionThe machine is electrically protected from producinghigh output currents. Should the output currentexceed 430A, an electronic protection circuit willreduce the current to approximately 100A. Themachine will continue to produce this low current untilthe protection circuit is reset. Reset occurs when theoutput load is removed.

Thermal ProtectionThermostats protect the machine from excessiveoperating temperatures. Excessive temperatures maybe caused by a lack of cooling air or operating themachine beyond the duty cycle and output rating. Ifexcessive operating temperature should occur, thethermostat will prevent output voltage or current. Themeter will remain energized during this time.

Thermostats are self-resetting once the machine coolssufficiently. If the thermostat shutdown was caused byexcessive output or duty cycle and the fan is operatingnormally, the Power Switch may be left on and thereset should occur within a 15 minute period.

INVERTEC® V350-PRO

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.• Do not touch electrically live parts or

electrode with skin or wet clothing.• Insulate yourself from work and

ground• Always wear dry insulating gloves.

------------------------------------------------------------------------EXPLODING PARTS can causeinjury.• Failed parts can explode or cause other

parts to explode when power is applied.• Always wear a face shield and long

sleeves when servicing.------------------------------------------------------------------------See additional warning informationthroughout this Operatorʼs Manual -----------------------------------------------------------

WARNING

CAPACITOR DISCHARGE PROCEDURE1. Obtain a power resistor (25 ohms, 25 watts).

2. Hold resistor body with electrically insulated glove.DO NOT TOUCH TERMINALS. Connect the resis-tor terminals across the two studs in the positionshown. Hold in each position for 1 second. Repeatfor all four capacitors.

3. Use a DC voltmeter to check that voltage is notpresent across the terminals on all four capacitors.

CAPACITORTERMINALS

RESISTOR

Page 24: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

E-1TROUBLESHOOTINGE-1

INVERTEC® V350-PRO

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

This Troubleshooting Guide is provided to help youlocate and repair possible machine malfunctions.Simply follow the three-step procedure listed below.

Step 1. LOCATE PROBLEM (SYMPTOM).Look under the column labeled “PROBLEM (SYMP-TOMS)”. This column describes possible symptomsthat the machine may exhibit. Find the listing thatbest describes the symptom that the machine isexhibiting.

Step 2. POSSIBLE CAUSE.The second column labeled “POSSIBLE CAUSE” liststhe obvious external possibilities that may contributeto the machine symptom.

Step 3. RECOMMENDED COURSE OF ACTIONThis column provides a course of action for thePossible Cause, generally it states to contact yourlocal Lincoln Authorized Field Service Facility.

If you do not understand or are unable to perform theRecommended Course of Action safely, contact yourlocal Lincoln Authorized Field Service Facility.

HOW TO USE TROUBLESHOOTING GUIDE

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.Unauthorized repairs performed on this equipment may result in danger to the technician andmachine operator and will invalidate your factory warranty. For your safety and to avoid ElectricalShock, please observe all safety notes and precautions detailed throughout this manual.

__________________________________________________________________________

WARNING

Page 25: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

E-2TROUBLESHOOTINGE-2

INVERTEC® V350-PRO

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manualPROBLEMS

(SYMPTOMS)POSSIBLE

CAUSERECOMMENDED

COURSE OF ACTIONMajor physical or electrical damageis evident when the sheet metalcovers are removed.

Input fuses keep blowing, or inputbreaker keeps tripping

Machine wil l not power up (Nolights)

Machine wonʼt weld, canʼt get anyoutput.

1. Contact your local authorizedLincoln Electric Field Service facil-ity for technical assistance.

1. Make certain that the fuses orbreakers are properly sized. Seeinstallation section of the manualfor recommended fuse and break-er sizes.

2. Welding procedure is drawing toomuch output current, or duty cycleis too high. Reduce output current,duty cycle or both.

3. There is internal damage to thepower source. Contact an autho-rized Lincoln Electric Service facil-ity.

1. Make certain that the powerswitch is in the "ON" position.

2. The circuit breaker in the recon-nect area may have opened.Reset. Check input voltage sec-tion below.

3. Input voltage selection madeimproperly. Power down, checkinput voltage reconnect accordingto diagram on reconnect cover.

4. The 6 amp breaker may haveopened. Check for overload on42VAC or 24VAC supply from the14 pin MS-style connector.

1. If the displays show an Err ###see the fault section for correctiveaction.

2. If the displays are not lit refer tomachine will not power up section.

3. If the thermal symbol is lit refer tothe thermal section.

4. If the output terminals are inremote control switch to "ON" andcheck for output voltage. If outputvoltage is now present check forcorrect remote control connectionand operation.

1.If all recommended possible areasof misadjustment have beenchecked and the problem persists,Contact your local LincolnAuthorized Field ServiceFacility.

Page 26: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

E-3TROUBLESHOOTINGE-3

INVERTEC® V350-PRO

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDEDCOURSE OF ACTION

Thermal symbol is lit

Wire feeder wonʼt work. Apparentlyno power to wire feeder

1. Check for proper fan operation. Iffan is not operating correctly theCB 2 amp breaker may haveopened. Check for an overload onthe 115VAC. Blow air in rear lou-vers to remove dirt from aroundfan.

2. Check for material blocking intakeor exhaust louvers.

3. Blow air in the rear louvers toclear dirt from the fan.

1. Check circuit breakers by the wirefeeder receptacles on the rear ofthe machine. Reset

2. Check the control cable betweenthe power source and the wirefeeder for continuity. 1.If all recommended possible areas

of misadjustment have beenchecked and the problem persists,Contact your local LincolnAuthorized Field ServiceFacility.

Page 27: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

E-4TROUBLESHOOTINGE-4

INVERTEC® V350-PRO

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Fault Codes

Code Description Corrective Action31 Primary over current. If condition persists The machine needs to

contact an authorized be turned off and backLincoln Field Service on to reset the machine.Shop

32 CAP bank A under voltage. Check input power Self-clearing as33 CAP bank B under voltage. reconnect to make sure condition ceases.34 CAP bank A over voltage. the machine 35 CAP bank B over voltage. is connected for the input 37 Soft start Failed. power being supplied. Cycle power.39 Glitch on the primary over Check the machine Self-clearing as

current fault interrupt; possibly ground. condition ceases.caused by noise or a signal level If problem persists(misc. hardware fault #1) contact an authorized

Lincoln Field Service Shop

43 CAP delta; CAP A and B are out Check input powerof balance. reconnect to make sure

the machine isconnected for the inputpower being supplied.

44 Main CPU problem. The DSP Check the machinehas detected a problem with the ground.CPU.

47 Possible erroneous electrical If problem persistsnoise on Voltage/Frequence contact an authorizedcapacitor feed back circuit. Lincoln Field Service

Shop(misc. hardware fault #2)

48 The main contactor opened If condition persist Self-clearingunexpectedly. (misc. hardware contact an authorizedfault #3) Lincoln Field Service

Shop"bad The selected weld mode does If condition persists Press the Modenodeʼ not exist in the weld table that is contact an authorized Select button to “####” presently loaded in the machine. Lincoln Field Service select a different

Shop mode

Page 28: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

E-5TROUBLESHOOTINGE-5

INVERTEC® V350-PRO

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact yourLocal Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Displays Description

Scrolling dash Appears at power up while the machine is going through its self configu-ration

"Err" "####" Fault code display. The first fault to occur will be displayed for threeseconds. The display will cycle through fault codes for all faults thatpersist after the initial three-second period are displayed for 1 sec-ond each.

"----" "----" Weld mode is changing

"----" "####" A constant voltage weld mode is selected, machine output is off.The numeric value in the right display is the work point.

"####" "----" A constant current weld mode is selected, machine output is off.The numeric value in the left display is either the work point or awork point limit, depending on the weld mode and remote configura-tion.

"####" "####"(on steady) machine output is on. Left display is current, right display is voltage.If actively welding, the displays are arc current and arc voltage. Ifnot actively welding, the display will show work point.

"####" "####" (blinking) weld just finished – the average arc voltage and current will beblinked for 5 seconds following a weld. If the work point changesduring this 5 second period, the display will revert to the abovemode.

Page 29: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-1DIAGRAMSF-1

INVERTEC® V350-PRO

TUR

N T

HE

POW

ER S

WIT

CH

OF

THE

WEL

DIN

G P

OW

ERSO

UR

CE

"OFF

" BE

FOR

E IN

STAL

LIN

G P

LUG

S O

N C

ABLE

SO

R W

HEN

CO

NN

ECTI

NG

OR

DIS

CO

NN

ECTI

NG

PLU

GS

TOW

ELD

ING

PO

WER

SO

UR

CE.

STR

AIG

HT

PLU

G (

14 P

IN)

TO P

OW

ER S

OU

RC

EC

ABLE

REC

EPTA

CLE

(6

SOC

KET)

CAB

LE R

ECEP

TAC

LE (

14 S

OC

KET)

TO:

1)

LN-7

WIR

E FE

EDER

S

TO:

1)

K857

REM

OTE

CO

NTR

OL

2

) K9

63 H

AND

AM

PTR

OL

3

) K8

70 F

OO

T AM

PTR

OL

K864

STR

AIG

HT

PLU

G (

14 P

IN)

TO P

OW

ER S

OU

RC

E

K876

CAB

LE R

ECEP

TAC

LE (

6 SO

CKE

T)TO

: 1

) LN

-25

WIR

E FE

EDER

S

S1

9309

4-1

9-96

D

RE

MOTE

CON

TROL

ADA

PTER

S

Page 30: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-2DIAGRAMSF-2

INVERTEC® V350-PRO

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.

N.B

. D

IAG

RAM

SH

OW

S EL

ECTR

OD

E PO

SITI

VE.

TO

CH

ANG

E PO

LAR

ITY,

TU

RN

PO

WER

"O

FF",

REV

ERSE

ELE

CTR

OD

E AN

D W

OR

K C

ABLE

AT

POW

ER S

OU

RC

E.

N.C

. I

NSU

LATE

EAC

H U

NU

SED

LEA

D I

ND

IVID

UAL

LY.

ELEC

TRO

DE

CAB

LETO

LN

-7

TO WO

RK

- +

14 P

INAM

PHEN

OL

SPAR

E82 81 42 41 31 32 2 4 21 GN

D

75 76 77

31 32 2 4 21 GN

D

N.C

.

K291

OR

K40

4IN

PUT

CAB

LE

K775

OPT

ION

ALR

EMO

TE C

ON

TRO

L

K867

UN

IVER

SAL

ADAP

TER

PLU

G

LN-7

CO

NTR

OL

BOX

75 76 77

GR

EEN

N.D

.

N.D

. S

PLIC

E LE

ADS

AND

IN

SULA

TE.

POW

ER S

OU

RC

E

AUXI

LIAR

Y PO

WER

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

INVE

RTE

C

WIT

H 1

15VA

C

S1

9404

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.

N.B

. D

IAG

RAM

SH

OW

S EL

ECTR

OD

E PO

SITI

VE.

TO

CH

ANG

E PO

LAR

ITY,

TU

RN

PO

WER

"O

FF",

REV

ERSE

ELE

CTR

OD

E AN

D W

OR

K C

ABLE

AT

POW

ER S

OU

RC

E.

N.C

. I

NSU

LATE

EAC

H U

NU

SED

LEA

D I

ND

IVID

UAL

LY.

ELEC

TRO

DE

CAB

LETO

LN

-7

TO WO

RK

- +

14 P

INAM

PHEN

OL

SPAR

E82 81 42 41 31 32 2 4 21 GN

D

75 76 77

31 32 2 4 21 GN

D

N.C

.

K291

OR

K40

4IN

PUT

CAB

LE

K775

OPT

ION

ALR

EMO

TE C

ON

TRO

L

K867

UN

IVER

SAL

ADAP

TER

PLU

G

LN-7

CO

NTR

OL

BOX

75 76 77

GR

EEN

N.D

.

N.D

. S

PLIC

E LE

ADS

AND

IN

SULA

TE.

POW

ER S

OU

RC

E

AUXI

LIAR

Y PO

WER

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

INVE

RTE

C

WIT

H 1

15VA

C

S1

9404

12-

10-9

3A

K867

PLU

G TO

LN-

7 - C

ONNE

CTIO

N DI

AGRA

M

Page 31: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-3DIAGRAMSF-3

INVERTEC® V350-PRO

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.

N.B

. D

IAG

RAM

SH

OW

S EL

ECTR

OD

E PO

SITI

VE.

TO

CH

ANG

E PO

LAR

ITY,

TU

RN

PO

WER

"O

FF",

REV

ERSE

ELE

CTR

OD

E AN

D W

OR

K C

ABLE

AT

POW

ER S

OU

RC

E.

N.C

. I

NSU

LATE

EAC

H U

NU

SED

LEA

D I

ND

IVID

UAL

LY.

TO WO

RK

- +

14 P

INAM

PHEN

OL

N.C

.EL

ECTR

OD

E C

ABLE

TO L

N-2

5

K867

AD

APTE

R

LN-2

5 W

ITH

K431

OPT

ION

K432

REM

OTE

CO

NTR

OL

CAB

LE

E F D A B C777675

SPAR

E4221 82 81 42 41 GN

D31 32

N.D

.

N.D

. R

EMO

VE 6

PIN

PLU

G F

RO

M

K432

CAB

LE I

N O

RD

ER T

O C

ON

NEC

T K8

67 P

LUG

.

LA

BEL

EAC

H L

EAD

(A

THR

U F

) AS

TH

EY A

RE

REM

OVE

D F

RO

M 6

PIN

PLU

G.

N.E

.

N.E

. S

PLIC

E LE

ADS

AND

IN

SULA

TE.

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

INVE

RTE

CPO

WER

SO

UR

CE

S1

9405

1-2

5-91

K867

PLU

G TO

LN-

25 -

CONN

ECTI

ON D

IAGR

AM

Page 32: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-4DIAGRAMSF-4

INVERTEC® V350-PRO

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.N

.B.

DIA

GR

AM S

HO

WS

ELEC

TRO

DE

POSI

TIVE

. T

O C

HAN

GE

POLA

RIT

Y, T

UR

N P

OW

ER "

OFF

",

R

EVER

SE E

LEC

TRO

DE

AND

WO

RK

CAB

LE A

T PO

WER

SO

UR

CE.

N.C

. I

NSU

LATE

EAC

H U

NU

SED

LEA

D I

ND

IVID

UAL

LY.

TO WO

RK

- +

14 P

INAM

PHEN

OL

N.C

.

7682

K867

UN

IVER

SAL

ADAP

TER

PLU

G

81

SPAR

E24 41 42 31 32 GN

D21 77 75

RE

MO

TE

OU

TP

UT

CO

NT

RO

L

NO

T U

SE

D O

N I

NV

ER

TE

C

CO

NN

EC

T T

OG

ET

HE

R F

OR

WE

LDIN

G O

UT

PU

T24

VA

C /

5.5

AM

P24

VA

C /

5.5

AM

P

42 V

AC

/ 5

.5 A

MP

115

VA

C /

2 A

MP

INV

ER

TE

C F

RA

ME

CO

NN

EC

TIO

N

N.D

.

N.D

. F

OR

WIR

E FE

EDER

S TH

AT R

ETU

RN

A S

IGN

AL F

OR

WEL

DIN

G O

UTP

UT,

USE

ISO

LATI

ON

REL

AY T

O C

LOSE

LEA

DS

2 &

4.2 4

TO K867

ELEC

TRO

DE

CAB

LE

WIR

E F

EE

DE

R V

OLT

ME

TE

R C

ON

NE

CT

ION

CO

NN

EC

TS

TO

(W

OR

K T

ER

MIN

AL)

OF

IN

VE

RT

EC

TO WIR

E FE

EDER

10K

MIN

.

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

INVE

RTE

C

POW

ER S

OU

RC

EW

ITH

115

VAC

AUXI

LIAR

Y PO

WER

S2

4985

3-

1-00

K867

UNI

VERS

AL A

DAPT

ER / I

NVER

TEC

- CON

NECT

ION

DIAG

RAM

Page 33: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-5DIAGRAMSF-5

INVERTEC® V350-PRO

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.

N.B

. D

IAG

RAM

SH

OW

S EL

ECTR

OD

E PO

SITI

VE.

TO

CH

ANG

E PO

LAR

ITY,

TU

RN

PO

WER

"O

FF",

REV

ERSE

ELE

CTR

OD

E AN

D W

OR

K C

ABLE

AT

POW

ER S

OU

RC

E.

TO WO

RK

- +

14 P

INAM

PHEN

OL

ELEC

TRO

DE

CAB

LETO

LN

-25

LN-2

5 W

ITH

K431

OPT

ION

K432

REM

OTE

CO

NTR

OL

CAB

LE

6 PI

NAM

PHEN

OL

N.C

. F

OR

IN

VER

TEC

S W

ITH

6 P

IN A

MPH

ENO

L, K

432

CAB

LE C

AN B

E C

ON

NEC

TED

DIR

ECTL

Y.

K876

AD

APTE

R

INVE

RTE

C

POW

ER S

OU

RC

E

S1

9899

1-2

5-91

K876

ADA

PTER

TO

LN-2

5 - C

ONNE

CTIO

N DI

AGRA

M

Page 34: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-6DIAGRAMSF-6

INVERTEC® V350-PRO

Only

qual

ified

per

sons

sho

uld

inst

all,

use

or

serv

ice th

is ma

chin

e.

usin

g th

e di

scon

nect

swi

tch

at th

e fu

se b

ox

WARN

INGTu

rn o

ff in

put p

ower

to th

e W

eldi

ng P

ower

Sou

rce

Befo

re c

onne

ctin

g th

e wi

re fe

eder

.

ELEC

TRIC

SHOC

KCA

N KILL

N.A

. W

ELD

ING

CAB

LE M

UST

BE

SIZE

D F

OR

CU

RR

ENT

AND

DU

TY C

YCLE

OF

APPL

ICAT

ION

.N

.B.

DIA

GR

AM S

HO

WS

ELEC

TRO

DE

POSI

TIVE

. T

O C

HAN

GE

POLA

RIT

Y, T

UR

N P

OW

ER "

OFF

",

R

EVER

SE E

LEC

TRO

DE

AND

WO

RK

CAB

LE A

T PO

WER

SO

UR

CE.

ELEC

TRO

DE

CAB

LETO

LN

-7

TO WO

RK

- +

14 P

INAM

PHEN

OL

LN-7

CO

NTR

OL

BOX

POW

ER S

OU

RC

EIN

VER

TEC

K864

K480

-7 I

NPU

T C

ABLE

14 P

INAM

PHEN

OL

K857

REM

OTE

CO

NTR

OL

K963

HAN

D A

MPT

RO

L

K870

FOO

T AM

PTR

OL

N.C

. K

480-

7 IN

PUT

CAB

LE C

AN B

E C

ON

NEC

TED

DIR

ECTL

Y IF

REM

OTE

CO

NTR

OL

IS N

OT

REQ

UIR

ED.

6 PI

NAM

PHEN

OL

ADAP

TER

OR

OR

N.D

. K

864

ADAP

TER

CAN

NO

T BE

USE

D W

ITH

AN

LN

-25.

WIT

H 1

15VA

CAU

XILI

ARY

POW

ER

S1

9901

4-1

9-96

D

K864

ADA

PTER

TO

LN-7

& R

EMOT

E CO

NTRO

L - C

ONNE

CTIO

N DI

AGRA

M

Page 35: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-7DIAGRAMSF-7

INVERTEC® V350-PRO

NOTE:

Thi

s dia

gra

m is

for re

fere

nce

onl

y.

It m

ay n

ot be

accu

rate

for al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m for a

par

ticul

ar c

ode

is p

aste

d in

side

the

mac

hine

on

one

of th

e en

closu

re p

anel

s. I

f th

e dia

gra

m is

ille

gib

le, w

rite

to the

Ser

vice

Dep

artm

ent fo

r a

repla

cem

ent. G

ive

the

equi

pm

ent co

de

num

ber

.

Page 36: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-8DIAGRAMSF-8

INVERTEC® V350-PRO

NOTE:

Thi

s dia

gra

m is

for re

fere

nce

onl

y.

It m

ay n

ot be

accu

rate

for al

l mac

hine

s co

vere

d b

y th

is m

anua

l. T

he s

pec

ific

dia

gra

m for a

par

ticul

ar c

ode

is p

aste

d in

side

the

mac

hine

on

one

of th

e en

closu

re p

anel

s. I

f th

e dia

gra

m is

ille

gib

le, w

rite

to the

Ser

vice

Dep

artm

ent fo

r a

repla

cem

ent. G

ive

the

equi

pm

ent co

de

num

ber

.

Page 37: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

F-9DIMENSION PRINTF-9

INVERTEC® V350-PRO

M19

527

6-01

14.7

9

12.4

4

3.44

21.0

6

27.8

2

5.50

10.0

0

MO

UN

TING

HO

LE L

OC

ATIO

NS

13.1

0

1/4-

20 N

UT (4

PLA

CES)

NO

TE:

MO

UN

TING

SC

REW

S C

ANN

OT

PRO

TRUD

E M

ORE

THA

N 0.

5 IN

CHES

INSI

DE T

HE M

ACHI

NE.

3.50

11.8

4

Page 38: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BEUSED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOSCONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS AETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

� Do not touch electrically live parts orelectrode with skin or wet clothing.

� Insulate yourself from work andground.

� No toque las partes o los electrodosbajo carga con la piel o ropa moja-da.

� Aislese del trabajo y de la tierra.

� Ne laissez ni la peau ni des vête-ments mouillés entrer en contactavec des pièces sous tension.

� Isolez-vous du travail et de la terre.

� Berühren Sie keine stromführendenTeile oder Elektroden mit IhremKörper oder feuchter Kleidung!

� Isolieren Sie sich von denElektroden und dem Erdboden!

� Não toque partes elétricas e elec-trodos com a pele ou roupa molha-da.

� Isole-se da peça e terra.

� Keep flammable materials away.

� Mantenga el material combustiblefuera del área de trabajo.

� Gardez à l’écart de tout matérielinflammable.

� Entfernen Sie brennbarres Material!

� Mantenha inflamáveis bem guarda-dos.

� Wear eye, ear and body protection.

� Protéjase los ojos, los oídos y elcuerpo.

� Protégez vos yeux, vos oreilles etvotre corps.

� Tragen Sie Augen-, Ohren- und Kör-perschutz!

� Use proteção para a vista, ouvido ecorpo.

Page 39: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

WARNING

AVISO DEPRECAUCION

ATTENTION

WARNUNG

ATENÇÃO

Spanish

French

German

Portuguese

Japanese

Chinese

Korean

Arabic

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA ASPRÁTICAS DE SEGURANÇA DO EMPREGADOR.

� Keep your head out of fumes.� Use ventilation or exhaust to

remove fumes from breathing zone.

� Los humos fuera de la zona de res-piración.

� Mantenga la cabeza fuera de loshumos. Utilice ventilación oaspiración para gases.

� Gardez la tête à l’écart des fumées.� Utilisez un ventilateur ou un aspira-

teur pour ôter les fumées des zonesde travail.

� Vermeiden Sie das Einatmen vonSchweibrauch!

� Sorgen Sie für gute Be- undEntlüftung des Arbeitsplatzes!

� Mantenha seu rosto da fumaça.� Use ventilação e exhaustão para

remover fumo da zona respiratória.

� Turn power off before servicing.

� Desconectar el cable de ali-mentación de poder de la máquinaantes de iniciar cualquier servicio.

� Débranchez le courant avantl’entretien.

� Strom vor Wartungsarbeitenabschalten! (Netzstrom völlig öff-nen; Maschine anhalten!)

� Não opere com as tampas removidas.� Desligue a corrente antes de fazer

serviço.� Não toque as partes elétricas nuas.

� Do not operate with panel open orguards off.

� No operar con panel abierto oguardas quitadas.

� N’opérez pas avec les panneauxouverts ou avec les dispositifs deprotection enlevés.

� Anlage nie ohne Schutzgehäuseoder Innenschutzverkleidung inBetrieb setzen!

� Mantenha-se afastado das partesmoventes.

� Não opere com os paineis abertosou guardas removidas.

Page 40: Lincoln V350-PRO Manual - Beal College - Welding Test …weldcenter.bealcollege.edu/data/V350.pdfLincoln arc welding and cutting equipment is designed and built with safety in mind.

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •