Linac Momentum Dump

35
Linac Momentum Dump Ti Window Results S.D. Reitzner 2/16/2011

description

Linac Momentum Dump. Ti Window Results S.D. Reitzner 2/16/2011. Linac Input Params. 400 MeV protons Vertex 350 cm upstream from wall Stainless steel pipe 6, 8” diameter Ti 6Al-4V window 10, 15 mils 5’, 4’, 2’, -10” from wall. Beam Window Side View. 5’ Sleeve. No Window. - PowerPoint PPT Presentation

Transcript of Linac Momentum Dump

Page 1: Linac Momentum Dump

Linac Momentum Dump

Ti Window ResultsS.D. Reitzner2/16/2011

Page 2: Linac Momentum Dump

Linac Input Params

• 400 MeV protons• Vertex – 350 cm upstream from wall

• Stainless steel pipe 6, 8” diameter• Ti 6Al-4V window 10, 15 mils– 5’, 4’, 2’, -10” from wall

Page 3: Linac Momentum Dump

Beam WindowSide View

5’ Sleeve

Page 4: Linac Momentum Dump

Total Flux (cm-2 s-1) No Window

Page 5: Linac Momentum Dump

FluenceR = 6”Z = 5’dZ = 10 mils

Page 6: Linac Momentum Dump

FluenceR = 8”Z = 5’dZ = 10 mils

Page 7: Linac Momentum Dump

FluenceR = 8”Z = 5’dZ = 15 mils

Page 8: Linac Momentum Dump

FluenceR = 6”Z = 4’dZ = 10 mils

Page 9: Linac Momentum Dump

FluenceR = 6”Z = 2’dZ = 10 mils

Page 10: Linac Momentum Dump

FluenceZ = -10”dZ = 10 mils

Page 11: Linac Momentum Dump

FluenceZ = -10”dZ = 15 mils

Page 12: Linac Momentum Dump

Dose Equivalent (mSv/hr) No Window

Page 13: Linac Momentum Dump

Dose Equivalent (mSv/h)R = 6”Z = 5’dZ = 10 mils

Page 14: Linac Momentum Dump

Dose Equivalent (mSv/h)R = 8”Z = 5’dZ = 10 mils

Page 15: Linac Momentum Dump

Dose Equivalent (mSv/h)R = 8”Z = 5’dZ = 15 mils

Page 16: Linac Momentum Dump

Dose Equivalent (mSv/h)R = 6”Z = 4’dZ = 10 mils

Page 17: Linac Momentum Dump

Dose Equivalent (mSv/h)R = 6”Z = 2’dZ = 10 mils

Page 18: Linac Momentum Dump

Dose Equivalent (mSv/h)Z = -10”dZ = 10 mils

Page 19: Linac Momentum Dump

Dose Equivalent (mSv/hr) Z = -10”dZ = 15 mils

Page 20: Linac Momentum Dump

Dose Residue (mSv/hr) No Window

Page 21: Linac Momentum Dump

Dose Residual (mSv/hr) R = 6”Z = 5’dZ = 10 mils

Page 22: Linac Momentum Dump

Dose Residual (mSv/hr) R = 8”Z = 5’dZ = 10 mils

Page 23: Linac Momentum Dump

Dose Residual (mSv/hr) R = 8”Z = 5’dZ = 15 mils

Page 24: Linac Momentum Dump

Dose ResidualR = 6”Z = 4’dZ = 10 mils

Page 25: Linac Momentum Dump

Dose ResidualR = 6”Z = 2’dZ = 10 mils

Page 26: Linac Momentum Dump

Dose Residual (mSv/hr) Z = -10”dZ = 10 mils

Page 27: Linac Momentum Dump

Dose Residual (mSv/hr) Z = -10”dZ = 15 mils

Page 28: Linac Momentum Dump

Star Density No Window

Page 29: Linac Momentum Dump

Star Density R = 6”Z = 5’dZ = 10 mils

Page 30: Linac Momentum Dump

Star DensityR = 8”Z = 5’dZ = 10 mils

Page 31: Linac Momentum Dump

Star DensityR = 8”Z = 5’dZ = 15 mils

Page 32: Linac Momentum Dump

R = 6”Z = 4’dZ = 10 mils

Star Density

Page 33: Linac Momentum Dump

Star DensityR = 6”Z = 2’dZ = 10 mils

Page 34: Linac Momentum Dump

Star DensityZ = -10”dZ = 10 mils

Page 35: Linac Momentum Dump