LIGHTING SYSTEMDALI QE GEN. MODEM BRIDGE PLC zona 1 .. N Building Management System TCP/IP GATEWAY...
Transcript of LIGHTING SYSTEMDALI QE GEN. MODEM BRIDGE PLC zona 1 .. N Building Management System TCP/IP GATEWAY...
TLedLIGHTING
SYSTEM
TLED LIGHTING SYSTEM
TLed is the innovative low-power LED lighting system developed by Fida for industrial and transportation applications.
TLed is the fruit of long research by our qualified team of engineers who have studiedand tested the most sophisticated LED diodes in order to guar-antee maximum performance with low power consumption, and innova-tive optics to reach maximum light output. In addition, they have designed dissipation systems to maintain thermal equilibrium and have conceived a tele-control system to monitor and control luminous bodies with maximum flexibility and safety.
The result is a concentration of technology.The outcome is the TLed.
11
2
Product Code TL70 TL150 TL250
Length - L (mm) 730 1445 2495
Width - W (mm) 63 63 63
Height - H (mm) 74 74 74
Protection Grade IP65 IP65 IP65
Operating Temperature -20°C / +50°C -20°C / +50°C -20°C / +50°C
Environmental Humidity 20% / 95% 20% / 95% 20% / 95%
Treatments / Standard Colors Natural Anodizing Natural Anodizing Natural Anodizing
Structure Material Aluminum Aluminum Aluminum
Glass Tempered Glass Tempered Glass Tempered Glass
Brightness Flow 2.400 Im* 3.600 Im* 8.000 Im*
Total Efficiency 120 Im/W 120 Im/W 120 Im/W
Color Temperature 4.000 K 4.000 K 4.000 K
Power Voltage 220 ÷ 240 Vac 220 ÷ 240 Vac 220 ÷ 240 Vac
Total Power Absorbed 20 W 30 W 65 W
Power Factor > 0.95 > 0.95 > 0.95
Ignition Time < 1 Sec < 1 Sec < 1 Sec
Dimmer DALI DALI DALI
Powerline CENELEC-B Powerline CENELEC-B
Powerline G3 Powerline G3
Nominal Life 50.000 hours 50.000 hours 50.000 hours
MTBF > 100.000 hours > 100.000 hours > 100.000 hours
MTTR 5 min 5 min 5 minMai
nte
nan
ceN
om
inal
Mec
han
ical
Par
amet
ers
TECHNICAL SPECIFICATIONS
Copyright © 2017 FIDA S.r.l.
Ele
ctri
cal
APPLIED DIRECTIVES
2014/35/EU – Low Voltage Directive2014/30/EU - Electromagnetic Compatibility Directive2011/65/CE – RoHS Directive (Restriction of Hazardous Substances Directive)
REFERENCE STANDARDS
CEI EN 60598 – Lighting Equipment CEI EN 62471 - Photobiological safety of lamps and lamp systemsCEI EN 62031 – LED Modules for general lighting- Safety SpecificationsUNI EN 13032 – Light and Illumination- Measurement and performance of photo-metric data of lamps and lighting fixturesCEI EN 60068-2 - Environmental Tests. Part 2: TestsCEI EN 60529 – Enclosure Protection Grade (IP65) CEI EN 62262 – Enclosure Protection Grade for electrical equipment against external mechanical impacts (IK08)
W
H
L
*with transparent glass without the use of opacifying films
3
STRUCTURE
THERMAL ALUMINUM DISSIPATOR
PREDISPOSITON FOR CEILING FIXTURE
LIGHT SOURCE WITH OPTICAL LENSES
OPTICAL PROTECTION
Structure realized in extruded aluminum, head-boarded in pressurized aluminum completed with silicon gaskets. The surface is finished in anodized silver finish.
Optical compartment closed on top by a 4mm thick tempered opal glass screen.
64
THERMAL ALUMINUM DISSIPATOR
5
OPTICS
LIGHT COLORING:
LIGHT FLOW:
4000° K
5.500 LM
150 LM/W
CRI 80 MIN.
LIGHT EFFICIENCY:
COLOR RENDERING INDEX:
These new devices can be equipped with particular lenses made in acrylic (PMMA) that determine and personalize the optical performance of the product. They canbe symmetrical or asymmetrical according to the illumination need.
ILLUMINOTECHNIC CHARACTERISTICS
400
600
800
1000
cd/klm 96%C0 - C180 C90 - C270
M � 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
200
400
600
800
1000
1200
cd/klm 96%C0 - C180 C90 - C270
90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0°
Light emission 1/CDL polar Light emission 1/CDL linear
6
SMART DRIVER
The TLed illumination system is controlled by a sophisticated diagnosticapparatus capable of sending information via internet through SMNP protocol to one or more remote locations. By using the function of certain commands, it is possible to control the ON and OFF function of each lamp and regulate the brightness either automatically through external light sensors, or through a programmed scheduling in relation to the days of the week or effective presence of travelers on the platform. The diagnostic system includes an operation software endowed with a very intuitive graphic dashboard that allows:
Switch the LED ON and OFF
Command the reduction of the luminous flux and then the power levels
Remote monitoring of temperature and real-time consumption
Monitor the efficiency of the lamp and power supply circuit
Diagnoses the end of the LED life cycle
Manage the protection of the LED in case of overheating
MONITORING AND TELECONTROL SYSTEMS
7
LESS CONSUMPTIONThe new illumination
technology LED guarantees over 50%
reduction in consumption costs.
LONGER LASTINGA LED lamp lasts 50.000
hours compared to that of a metallic iodide lamp that lasts
20.000 hours of compared to 15.000 hours of a Linear
Fluorescent Tube.
HIGHER BRIGHTNESSThe brightness of
an LED lamp is 22% superior than the Linear
Fluorescent Tube.
MODERN DESIGNPerfect harmony between functionality, technology,
design, and care for details that mirrors the Made in
Italy design.
EASY MAINTENANCELinear LED system is
makes access for maintenance easy and also for lamp
replacement.
PLANT INTEGRATIONPerfectly designed for the easy integration of extra components such as video-cameras, signs, sound diffusion systems
and Wi-Fi Hotspot.
MAX MODULARITYThe complete modularity
of the unit facilitates assemblage procedures avoiding wall and ceiling
perforations.
TELECONTROL A sophisticated diagnostic
system that can remote-ly monitor luminosity, optimizing costs and
maintenance.
REGULATING BRIGHTNESSIt is possible to prolong
the units life-cycle through light regulation, lowering
the LED temperature when functioning.
ADVANTAGES
108
9
The TLed system was created to be installed in various architectural contexts, adapting to any existent structure. The Tled modules are designed to be electrically connected in a chain through a passing electric connec-tion (max 20 modules per max 70 m).
TYPES OF INSTALLATION
A
SIMPLE TRADITIONAL T-LUX REVAMPING
MULTIPLE DUCTS COUNTERTOP BUILT-IN SYSTEM
10
CEILING CARTER FOR QUAY
CEILING SYSTEMS
ANGULAR CARTER
CORNER DUCT FOR UNDERPASSES
11
CONTINUOUS CENTRAL LINE
LONGITUDINAL ASSE - RAYTRACE
100% FLOW – False colors, illumination in [ lx ]
30% FLOW - False colors, illumination in [ lx ]
12
LONGITUDINAL ASSE - RAYTRACE
CONTINUOUS DOUBLE LINE
100% FLOW – False colors, illumination in [ lx ]
30% FLOW - False colors, illumination in [ lx ]
13
SYSTEM ARCHITECTURE
QDSG3
CENELEC-B
QDSG3 -DALI
QEGEN.
MODEM BRIDGE PLC
zona 1 .. N
BuildingManagementSystem
TCP/IP
GATEWAYG3 / DALI
max 64 lamps
220Vac
220Vac - Emergency
220V
ac
220V
ac -
Emer
genc
y / G
3-P
LC
LineDALI
TLed - DALI
TLed - G3 PLC
TLed - CENELEC-B PLC
220V
ac /
G3-
PLC
220Vac / CENELEC-B -PLC
EmergencyLamp
KNX LIGHT SENSOR
LIGHT SENSOR
LIGHT SENSOR
414
The management system is run on a desktop app for O.S. Windows 64bit using C# and .Net Framework 4.5.
The application uses a standard relational DB, Microsoft SQL server, to configure and run the lamps map and communication systems and collect diagnostic data of the lamps.
The system automatically does the following:
The system dedicated to the automatic and centralized management of the lighting system is composed of a Supervision Software installed on a Windows PC that communicates in specific cases with different devices of the illumination/signaling devices through BUS communication Powerline (PLC carried waves) using a AC220V power supply of the lamps.
Memorization of the system events log with the diagnostic operations detail, alarms, perturbations, commands, scheduling, etc.
Acquisition of diagnostic and operative parameters of the lamp
Alarm generation in case of technical fault of the lamps
Activation of application functions of Starting/turning off/programmed regula-tion for the lamps Zone
Thanks to the versatility of the application software, the system can be easily inte-grated in already existent automation systems.
In this case, the communication with external systems is realized through con-nections to standard-type ports such as Lan Ethernet (socket IP) and serial ports RS232/RS484. It is possible to implement standard communication protocols for special requests.
MANAGEMENT SYSTEM FOR POWERLINE ARCHITECTURE
History of starting and alarm events listed in Database
System of diagnostic supervision/sending alarms to external systems (optional)
Icon and Graphic interface with zone maps
Ability administrator system with password
Configuration Zone and bridge NC
Control panel of diagnostic “real time” state of the Lamps
Configuration Lamps/Box lights
Preparation of application procedures for lamps zone-time frames
Sending commands to Lamp (starting/turning off/dimming)
APPLICATION FUNCTIONS SYNTHESIS:
REV.0307/09/2017
Disclaimer and Copyright © 2017Fida Srl Corporate Identity Office Our company reserves the right to
make any modifications to it’s production without any notice. It isprohibited to reproduce any part of this catalogue without the written
consent of Fida Srl Some images in this catalogue refer to conceptideas or examples of possible applications.
Fida Srl recognizes to not have any property right oftrademarks or brand names of thirdparty property.
22
www.fida.it
Over
Fida srlT. + 39 039 878733 F. + 39 039 882003
Headquarter Via Volturno 135 - 20861
Brugherio (MB) - Italy
Milan
Branch OfficePiazza Flavio Biondo 7 - 00153
Roma (RM) - Italy
Rome