Lighting Electronics | 2007/08

104
Visit: www.hueco.com From Kuala Lumpur to Beijing the Lighting industry, planners, architects, wholesalers and builders appre- ciate our components and benefits. We strive to exceed our customers expectations through: Out- standing performance, improved safety and greater life time. We are original equipment manufacturers (OEM) for the lighting industry for public buildings, ship outfit- ters and for emergency lighting. HÜCO, a worlwide partner for the lighting industry. All this has a simple reason. We know what our customers want; because we ask them. We produce Components, which are installed with the luminaires and left for many years - Fit and Forget. HÜCO is remembered for light. Lighting Electronics | 2007/08 Electronic Ballasts Electronic Transformers Trailing Edge Phase-Cut Dimmer

Transcript of Lighting Electronics | 2007/08

Page 1: Lighting Electronics | 2007/08

Visit: www.hueco.com

From Kuala Lumpur to Beijing the Lighting industry,

planners, architects, wholesalers and builders appre-

ciate our components and benefits. We strive to

exceed our customers expectations through: Out-

standing performance, improved safety and greater

life time.

We are original equipment manufacturers (OEM) for

the lighting industry for public buildings, ship outfit-

ters and for emergency lighting. HÜCO, a worlwide

partner for the lighting industry. All this has a simple

reason. We know what our customers want; because

we ask them.

We produce Components,

which are installed with the

luminaires and left for many

years - Fit and Forget.

HÜCO is remembered for light.

Lighting Electronics | 2007/08

Electronic Ballasts

Electronic Transformers

Trailing Edge Phase-Cut Dimmer

Page 2: Lighting Electronics | 2007/08

Outstanding product features developed for you

Many unique HÜCO-solutions are developed and evolve in close partnership with our customers, for example the HÜCO Lamp Con-trol Technology (HLC) or the markets smallest dimmable ballast. Our global sales logistics and the excellent customer service are the results of our ongoing partnerships with the key organisations in the lamp and luminaire marketplace.

Quality starts at product developmentThe people working for HÜCO in Germany and abroad are highly-qualified experts with years of experience. They are committed to the principle of HÜCO, the best solutions are the simple solutions: Development and production of highly reliable products by excluding all the features that are not needed in every-day life.

We understand a lot depends on our components - for example the light in skyscrapers, exterior lighting or factory lighting, where our components are integrated into the fittings and in use every day.

About us

25 years experienceFor more than 20 years our customers have continued success with their own end customers. Because we know what they need: Com-ponents, which are installed with the luminaires and left for many years - Fit and Forget. HÜCO is remembered for light.

HÜCO-Quality as standardThe quality management system in the HÜCO group is accredited to the DIN EN ISO 9001:2000 standard - from the development through to the purchase of raw materials and from the production to our sales logistics and service.

We looking forward to welcoming you.

Products

In this catalogue you find:• Multipower technology based ballasts

• Electronic ballasts with DALI technology

• Dimmable electronic ballasts

• Electronic transformers

• Trailing-edge dimmers

• Complimentary lighting components.

You can find our entire product range and the easy search

facility at our website www.hueco.com

For 25 years our quality and

innovations are the basis for

continous growth and

worldwide acceptance.

Page 3: Lighting Electronics | 2007/08

www.hueco.com 3

Longterm product reliabilityand trust into innovative technologyHüco can look back on over 20 years experience in lighting electro-nics and the reliability of our products reflects our acquired know-how and our Quality philosophy. In order to maintain this quality level we have developed a comprehensive Quality Management system. The international standard EN ISO 9001:2000 is integrated and operating throughout the organisation.The million fold use of Hüco ballasts by notable lighting manufacturers confirms that our product philosophy is in keeping with the require-ments of the international market.

3 STAR Comfort Warranty for all products3 STAR Comfort Warranty for all products is the new name for the exis-ting 3 year guarantee. It consists of 2 obligatory years and a ‘special’ extra year’s warranty.

Guarantee

5 STAR Premium Guarantee

The guarantee is extended to 5 years in total by registration of an installation and the use of lamps conforming to IEC Standard. Please complete the registration document a forward within 30 days of commissioning the installation to Hüco.

The registration form is available for download at www.hueco.com

GuaranteeThe guarantee covers all High Performance ballasts in HC or HS hou-sings, and Hüco transformers. The equipment must be installed and operated in accordance with the manufacturers recommendations. In the event of a complaint Hüco electronic GmbH will provide a free repair or replacement or a credit for those products which can be demonstrably shown to have failed within the relevant time period due to a component or manufacturing. Legal rights are not affected and are independent of the warranty. Hüco electronic GmbH reser-ves the right to decide on the authorisation of a claim. So it is then necessary to send the failed equipment (for defect analysis) and a copy of the registration form in each case.

5 STAR Premium Guarantee for registered lighting systems The 5 STAR Premium Guarantee extends the guarantee for the functio-nality of all High Performance ballasts in HC or HS housings, and Hüco transformers in a registered lighting installation for a further 2 years to a total of 5 years. This is done by a simple registration process. No specific lamp brands are stipulated, other than the obligation to use lamps which conform to IEC-Standard. Accordingly your choice of replacement lamps is not restricted. The 5 year Premium Guarantee begins with the commissioning and registration of the installation.

Page 4: Lighting Electronics | 2007/08

4 Subject to technical modifications

With regard to the increasing energy costs in the future, the system“Electronic Ballast (Ballast) and Fluorescent Lamp” is the best illumi-nation solution when considering the economic, conveniece and environmental aspects.

HÜCO offers a wide range of electronic ballasts in various versionsfor the different kinds of fluorescent lamps. The development ofcustomer specific solutions for their particular problems is as impor-tant to us as the continious development of these ballasts in line with changing market needs.

The high economy when operating full-electronic HÜCO ballasts compared to the conventional operation is mainly achieved by a power consumption of less than 25% at the same efficiency of lumi-noussource and a lamp life-span of more than 50% by high-fre-quency operation. Consequently, the maintenance costs are not ashigh due to longer exchange intervals of the lamps.

Apart from the economy the use of full-electronic bal-lasts has some other important advantages:• Ballasts with active PFC provide a constant luminous flux for a wide

input voltage range and therefore guarantee a constant lighting level which does not depend on fluctuations in the mains voltage. Fur-thermore, the lamp is constantly supplied and thus contributes to a longer life-span of the lamp.

• When using the “Multipower-Ballast” it is no longer necessary to have different electronic ballasts for different lamp types on stock, because this Ballast can operate alternatively different lamps. Con-sequently, it is easier to handle the logistics and there is less capital tied-up in stock

• There is an increasing demand of convenient solutions in the range of illumination, in particular with regard to the dimming. If the custo-mer asks also for high economy, the dimmable HÜCO ballasts for energy saving fluorescent lamps are the best solution.

• The compact shape makes it possible to use the Ballast for various applications. In addition, HÜCO Ballasts have the advantage to effect an independent illumination planning regarding the que-stion of dimming. This is because nearly the complete range of DIM-Ballasts has the same dimensions as the non-dimmable Bal-lasts. Due to the these advantages the HÜCO ballasts are suitable for different applications such as outside illumination, offices, pro-duction areas with long switch-on time, rooms fitted with screens, tunnels, underground car parks, safety and emergency lighting, hospitals and medical rooms.

HÜCO Electronic Ballasts

Important differences between magnetic ballast and electronic ballast

Magnetic ballast + Starter

Electronic ballast

Flicker-free light/high light comfort no yes

Flicker-free start no yes

Stroboscope effect yes no

Energy saving to KVG ca. 25%

Self-heating large small

Dependence on mains fluc-tuations strong small

Lamp switching constancy small high

DC operation (emergency power) not possible possible

Disconnection in the event of an error no (only DEOS) yes

Magnetic breakdown induction large small

Weight 0,8 - 15kg < 450g

Wiring cost large small

needs compensation yes no

Page 5: Lighting Electronics | 2007/08

www.hueco.com 5

LifetimeThe life time is 30.000 hours with a maximum ambient temperature of 50/55°C and failure rate 10 %. Due to the low power loss of the ballasts, typically 1,5W,there will be a lower temperature inside many luminaries, resulting in a lifetime of 60.000 hours with ambient tem-perature of ta maximum -10°C.

Constant Power Output and emergency operationWhen operating in AC, the lamp power will be maintained at +/- 5 % constant; so the voltage variations in the range of 207 – 253V do not impact directly on light output. In emergency operation the lamp power reduces in proportion to the input voltage. In case of a voltage of 176V AC the ballast reduces the lamp power by approx. 50 % and so central battery systems can be installed with considerably smaller battery capacities.

Lifetime of lampsAll ballasts are warm start ballasts. The lamps are pre-heated and operated according to EN 60929. Thus a long lamplife is assured; additionally the ballasts exhibit a particularly quick start.

Fittings with class IIThe ballasts do not require an earth connection and so are suitable for the incorporation in fittings with class II.

Housings and fixingThe housings are manufactured from robust PC/ABS and have a additional side-mount option which gives more scope for the fitting designer.

SafetyAll Mini Powers are tested by VDE for fulfilment of the safety standards and are accordingly VDE marked. Furthermore, the ballasts have a safety shutdown on detection of EOL ( end of life) of the lamp.

For some time now HÜCO has monitored the development of the existing miniature or low-cost electronic ballasts on the market. This market research which was carried out in advance of the development of the Huco Mini Power series showed a high proportion of light-ing manufacturers do not see their needs fulfilled by the “low-cost” ballasts currently available on the market. In many cases “low-cost” means just “low-value” in the components and the circuit design.

The information indicated in the data sheets of the manufacturer regarding life time and reliability is often nowhere near those achieved in practise. In some cases the “low-cost” ballast will quickly become ”high-cost” due to maintenance and replacement costs. Typically such ballasts often have an unsuitable ambient temperature of 40 or 45°C, no constant power over the permitted mains voltage range , insuffi-cient pre-heating of the cathodes, etc. For the solution to these prob-lems we have developed the HÜCO Mini Power series.

The solution. Mini Power Series or Mini Power “i”

(integrated socket)

All ballasts are based on our Multipower Technology of which we have over 1 million already in use and is especially suited to the smaller configuration of Mini Power ballasts which are also controlled by dig-ital ASIC.( Application Specific Integrated Circuit) technology.

TemperatureThe maximum ambient temperature is 50/55°C, so the ballasts can be installed in small fittings which are inclined to generate more heat.

Minipower Ballasts

Application Sample:Ballast only without

lamp available

Page 6: Lighting Electronics | 2007/08

6

7

8

9

10

11

12

13

83

14

16 - 3882

39 - 49

49 - 55

56 - 63

64 - 71

72 - 75

76 - 81

83 - 85

86 - 89

90

91 - 92

93

94 - 95

96

97

98

99

100

101

102

103

Subject to technical modifications

Table of contents

Electronic Ballasts for TC-SEL

Electronic Ballasts for TC-DEL/TEL

Electronic Ballasts for TC-L/F

Electronic Ballasts for TC-DD

Electronic Ballasts for T5c

Electronic Ballasts for T5

Electronic Ballasts for T8

Electronic Ballasts for HID

List of article numbers

Product by type

Compact Electronic Ballasts,not dimmable

Compact Electronic Ballasts,1...10V dimmable

Compact Electronic Ballasts,DALI dimmable

T5 Electronic Ballasts,not dimmable

T5 Electronic Ballasts,1...10V dimmable

T8 Electronic Ballasts,not dimmable

T8 Electronic Ballasts,1...10V dimmable

HID Electronic Ballasts

Electronic Transformers

Trailing Edge Phase-Cut Dimmer

Accessories

Various markings of electronic control gear

Savings by use of electronic Ballasts

HLC Technology (HÜCO Lamp Control)

Max. number of ballasts at miniature circuit breaker

Dimmable electronic ballasts

DALI dimmable electronic ballastsExamples of circuits fordimmable ballasts

Reference list control equipment 1-10 V controls

Lifetime of HÜCO ballasts

Electronic Transformers

General sales conditions

Selection by lamp Technical appendix

Page 7: Lighting Electronics | 2007/08

TC-SELTC-SEL 2G7 Biax™ S/E Dulux® S/E PL-SxxW/4P Ralux/E CF-SE

7 W 1 095233 80 40 22 + 177 W 1 096217 82 40 29 + 829 W 1 095233 80 40 22 + 179 W 1 096217 82 40 29 + 829 W 1 097543 103 67 30 + 329 W 1 095043 150 42 30 + 339 W 2 097543 103 67 30 + 329 W 2 095043 150 42 30 + 33

11 W 1 095233 80 40 22 + 1711 W 1 097543 103 67 30 + 3211 W 1 095043 150 42 30 + 3311 W 2 097543 103 67 30 + 3211 W 2 095043 150 42 30 + 33

7

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Page 8: Lighting Electronics | 2007/08

TC-DEL TC-TEL TC-DEL

TC-TEL

G24q

GX24q

Biax™ D/E

Biax™ T/E

Dulux® D/E

Dulux® T/E

PL-CxxW/4P

PL-TxxW/4P

Ralux duo/E

Ralux trio/E

CF-DE

CF-TE

10 W 1 095243 62 62 56 + 2010 W 1 095233 80 40 22 + 1710 W 1 096217 82 40 29 + 8210 W 1 097543 103 67 30 + 3210 W 1 095043 150 42 30 + 3310 W 2 097543 103 67 30 + 3210 W 2 095043 150 42 30 + 3313 W 1 095243 62 62 56 + 2013 W 1 095233 80 40 22 + 1713 W 1 097543 103 67 30 + 3213 W 1 097574 103 67 30 1...10V 3913 W 1 095043 150 42 30 + 3313 W 2 097543 103 67 30 + 3213 W 2 097584 123 79 33 1...10V 4513 W 2 095043 150 42 30 + 3318 W 1 095244 62 62 56 2118 W 1 095234 80 40 22 1818 W 1 097534 103 67 30 2218 W 1 097544 103 67 30 + 3418 W 1 097575 103 67 30 1...10V 3918 W 1 097875 123 79 33 DALI 4918 W 1 095044 150 42 30 + 3418 W 2 097544 103 67 30 + 3418 W 2 097585 123 79 33 1...10V 4618 W 2 097885 123 102 33 DALI 5318 W 2 095044 150 42 30 + 3426 W 1 095235 80 40 22 + 1926 W 1 097535 103 67 30 + 2326 W 1 097545 103 67 30 + 3526 W 1 097570 103 67 30 1...10V + 4026 W 1 497535 103 67 30 + 2326 W 1 097548 123 79 33 + 3726 W 1 097870 123 79 33 DALI + 5026 W 1 095045 150 42 30 + 3626 W 2 097545 103 67 30 + 3526 W 2 097548 123 79 33 + 3726 W 2 097555 123 79 33 + 3826 W 2 097580 123 102 33 1...10V + 4726 W 2 097586 123 79 33 1...10V 4626 W 2 097880 123 102 33 DALI + 5426 W 2 095045 150 42 30 + 3632 W 1 097570 103 67 30 1...10V + 4032 W 1 097535 103 67 30 + 2332 W 1 097545 103 67 30 + 3532 W 1 497535 103 67 30 + 2332 W 1 097870 123 79 33 DALI + 5032 W 1 097548 123 79 33 + 3732 W 1 095045 150 42 30 + 3632 W 2 097580 123 102 33 1...10V + 4732 W 2 097880 123 102 33 DALI + 5432 W 2 097548 123 79 33 + 3732 W 2 097555 123 79 33 + 3842 W 1 097570 103 67 30 1...10V + 4042 W 1 097535 103 67 30 + 2342 W 1 097545 103 67 30 + 3542 W 1 497535 103 67 30 + 2342 W 1 097870 123 79 33 DALI + 5042 W 1 097548 123 79 33 + 3742 W 1 095045 150 42 30 + 3642 W 2 097580 123 102 33 1...10V + 4742 W 2 097880 123 102 33 DALI + 5442 W 2 097548 123 79 33 + 3757 W 1 097539 103 67 30 2457 W 1 097571 123 79 33 1...10V + 4170 W 1 097571 123 79 33 1...10V + 4170 W 1 097540 123 79 33 24

8

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Page 9: Lighting Electronics | 2007/08

TC-DEL TC-TEL

TC-L TC-F

TC-L

TC-F

2G11

2G10

Biax™ L Dulux® L

Dulux® F

PL-L

PL-TxxW/4P

Ralux long

Ralux twin

CF-L/LE

CF-F

18 W 1 097516 103 67 30 1...10V + 4218 W 1 097535 103 67 30 + 2318 W 1 097545 103 67 30 + 3518 W 1 497535 103 67 30 + 2318 W 1 097816 123 79 33 DALI + 5118 W 1 095045 150 42 30 + 3618 W 2 097545 103 67 30 + 3518 W 2 097526 123 79 33 1...10V + 4818 W 2 097826 123 102 33 DALI + 5518 W 2 097555 123 79 33 + 3818 W 2 095045 150 42 30 + 3618 W 3 097161 280 39 21 + 7518 W 4 097161 280 39 21 + 7524 W 1 095235 80 40 22 + 1924 W 1 097516 103 67 30 1...10V + 4224 W 1 097535 103 67 30 + 2324 W 1 097545 103 67 30 + 3524 W 1 497535 103 67 30 + 2324 W 1 097816 123 79 33 DALI + 5124 W 1 095045 150 42 30 + 3624 W 1 097367 360 30 21 Switch Control + 7124 W 2 097545 103 67 30 + 3524 W 2 097526 123 79 33 1...10V + 4824 W 2 097826 123 102 33 DALI + 5524 W 2 097555 123 79 33 + 3824 W 2 095045 150 42 30 + 3624 W 2 097377 430 30 21 Switch Control + 7124 W 3 097161 280 39 21 + 7536 W 1 097437 103 67 30 + 2836 W 1 097535 103 67 30 + 2336 W 1 497535 103 67 30 + 2336 W 1 097427 150 42 30 + 2936 W 1 097206 280 30 21 + 5736 W 1 097177 360 30 21 Switch Control + 8136 W 2 097216 360 30 21 + 6136 W 2 097187 430 30 21 Switch Control + 8140 W 1 097535 103 67 30 + 2340 W 1 097545 103 67 30 + 3540 W 1 497535 103 67 30 + 2340 W 1 095045 150 42 30 + 3640 W 1 097206 280 30 21 + 5740 W 1 097368 360 30 21 Switch Control + 7140 W 2 097555 123 79 33 + 3840 W 2 097216 360 30 21 + 6140 W 2 097378 430 30 21 Switch Control + 7155 W 1 097634 103 67 30 + 2555 W 1 097864 123 79 33 DALI + 5255 W 1 097079 280 30 21 1...10V 4555 W 1 097039 280 30 21 3155 W 1 097209 280 30 21 + 5955 W 1 097078 360 30 21 Switch Control 7155 W 2 097089 360 30 21 1...10V 4955 W 2 097058 360 30 21 3155 W 2 097088 430 30 21 Switch Control 7180 W 1 097209 280 30 21 + 5980 W 1 097371 360 30 21 Switch Control + 71

9

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Page 10: Lighting Electronics | 2007/08

TC-DDTC-DD GR10q Biax™ 2D

10 W 1 097543 103 67 30 + 3210 W 1 095043 150 42 30 + 3310 W 2 097543 103 67 30 + 3210 W 2 095043 150 42 30 + 3316 W 1 097543 103 67 30 + 3216 W 1 095043 150 42 30 + 3316 W 2 097543 103 67 30 + 3216 W 2 095043 150 42 30 + 3328 W 1 095238 80 40 22 2628 W 1 097475 103 67 30 1...10V 4428 W 1 097436 103 67 30 2728 W 1 097426 150 42 30 + 2738 W 1 097477 103 67 30 1...10V 4438 W 1 097437 103 67 30 + 2838 W 1 097427 150 42 30 + 2955 W 1 097438 123 79 33 30

10

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Page 11: Lighting Electronics | 2007/08

TC-DD

T5c (T16-R)

T5c 2GX13 Circline™ Lumilux® FC T5c

22 W 1 095235 80 40 22 + 1922 W 1 097516 103 67 30 1...10V + 4222 W 1 097535 103 67 30 + 2322 W 1 097545 103 67 30 + 3522 W 1 497535 103 67 30 + 2322 W 1 097816 123 79 33 DALI + 5122 W 1 095045 150 42 30 + 3622 W 2 097545 103 67 30 + 3522 W 2 097555 123 79 33 + 3822 W 2 095045 150 42 30 + 3640 W 1 097516 103 67 30 1...10V + 4240 W 1 097535 103 67 30 + 2340 W 1 097545 103 67 30 + 3540 W 1 497535 103 67 30 + 2340 W 1 097816 123 79 33 DALI + 5140 W 1 095045 150 42 30 + 3640 W 1 097368 360 30 21 Switch Control + 7140 W 2 097555 123 79 33 + 3840 W 2 097378 430 30 21 Switch Control + 7155 W 1 097634 103 67 30 + 2555 W 1 097674 123 79 33 1...10V 4355 W 1 097864 123 79 33 DALI + 5260 W 1 097635 103 67 30 2660 W 1 097675 123 79 33 1...10V 4360 W 1 097865 123 79 33 DALI 52

11

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Page 12: Lighting Electronics | 2007/08

T5 (T16) T5 G5 Starcoat Lumilux® FH/FQ TL NL F

4 W 1 096217 82 40 29 + 826 W 1 095232 80 40 22 + 166 W 1 096217 82 40 29 + 828 W 1 095232 80 40 22 + 168 W 1 096217 82 40 29 + 82

13 W 1 095232 80 40 22 + 1614 W 1 095233 80 40 22 + 1714 W 1 097543 103 67 30 + 3214 W 1 095043 150 42 30 + 3314 W 1 097204 280 30 21 + 5614 W 1 097363 360 30 21 Switch Control 7114 W 1 097244 360 30 21 1...10V + 6414 W 2 097543 103 67 30 + 3214 W 2 095043 150 42 30 + 3314 W 2 097214 360 30 21 + 6014 W 2 097294 425 30 21 1...10V + 6814 W 2 097373 430 30 21 Switch Control 7114 W 3 097381 280 39 21 + 6314 W 4 097381 280 39 21 + 6314 W 4 097361 430 30 21 Switch Control 7121 W 1 097543 103 67 30 + 3221 W 1 095043 150 42 30 + 3321 W 1 097204 280 30 21 + 5621 W 1 097364 360 30 21 Switch Control 7121 W 1 097244 360 30 21 1...10V + 6421 W 2 097214 360 30 21 + 6021 W 2 097294 425 30 21 1...10V + 6821 W 2 097374 430 30 21 Switch Control 7124 W 1 097535 103 67 30 + 2324 W 1 097545 103 67 30 + 3524 W 1 497535 103 67 30 + 2324 W 1 095045 150 42 30 + 3624 W 1 097206 280 30 21 + 5724 W 1 097367 360 30 21 Switch Control + 7124 W 1 097246 360 30 21 1...10V + 6524 W 2 097545 103 67 30 + 3524 W 2 095045 150 42 30 + 3624 W 2 097216 360 30 21 + 6124 W 2 097296 425 30 21 1...10V + 6924 W 2 097377 430 30 21 Switch Control + 7124 W 3 097161 280 39 21 + 7528 W 1 097204 280 30 21 + 5628 W 1 097365 360 30 21 Switch Control 7128 W 1 097244 360 30 21 1...10V + 6428 W 2 097214 360 30 21 + 6028 W 2 097294 425 30 21 1...10V + 6828 W 2 097375 430 30 21 Switch Control 7135 W 1 097204 280 30 21 + 5635 W 1 097366 360 30 21 Switch Control 7135 W 1 097244 360 30 21 1...10V + 6435 W 2 097214 360 30 21 + 6035 W 2 097294 425 30 21 1...10V + 6835 W 2 097376 430 30 21 Switch Control 7139 W 1 097535 103 67 30 + 2339 W 1 097545 103 67 30 + 3539 W 1 497535 103 67 30 + 2339 W 1 095045 150 42 30 + 3639 W 1 097206 280 30 21 + 5739 W 1 097368 360 30 21 Switch Control + 7139 W 1 097246 360 30 21 1...10V + 6539 W 2 097216 360 30 21 + 6139 W 2 097296 425 30 21 1...10V + 6939 W 2 097378 430 30 21 Switch Control + 7149 W 1 097207 280 30 21 5849 W 1 097369 360 30 21 Switch Control 7149 W 1 097247 360 30 21 1...10V 6649 W 2 097217 360 30 21 6249 W 2 097297 425 30 21 1...10V 7049 W 2 097379 430 30 21 Switch Control 7154 W 1 097208 280 30 21 5854 W 1 097370 360 30 21 Switch Control 7154 W 1 097248 360 30 21 1...10V 6654 W 2 097218 360 30 21 6254 W 2 097298 425 30 21 1...10V 7054 W 2 097380 430 30 21 Switch Control 7180 W 1 097209 280 30 21 + 5980 W 1 097371 360 30 21 Switch Control + 7180 W 1 097249 360 30 21 1...10V 67

12

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Page 13: Lighting Electronics | 2007/08

T5

T8 T12 (T38)

T8 G13 Polylux™ Lumilux® TL NL F

T12

(T38)G13

Standard Halosphate

L

40 W 1 097535 103 67 30 + 2340 W 1 097545 103 67 30 + 3540 W 1 497535 103 67 30 + 2340 W 1 095045 150 42 30 + 36

15 W 1 097535 103 67 30 + 2315 W 1 097545 103 67 30 + 3515 W 1 497535 103 67 30 + 2315 W 1 095045 150 42 30 + 3615 W 2 097545 103 67 30 + 3515 W 2 095045 150 42 30 + 3615 W 3 097161 280 39 21 + 7515 W 4 097161 280 39 21 + 7518 W 1 097535 103 67 30 + 2318 W 1 097545 103 67 30 + 3518 W 1 497535 103 67 30 + 2318 W 1 095045 150 42 30 + 3618 W 1 097113 280 30 21 7218 W 1 097176 360 30 21 Switch Control 8118 W 1 097143 360 30 21 1...10V 7618 W 2 097545 103 67 30 + 3518 W 2 095045 150 42 30 + 3618 W 2 097123 280 30 21 7318 W 2 097193 425 30 21 1...10V 7818 W 2 097186 430 30 21 Switch Control 8118 W 3 097161 280 39 21 + 7518 W 4 097161 280 39 21 + 7518 W 4 097172 430 30 21 Switch Control 8130 W 1 097426 150 42 30 + 2736 W 1 097535 103 67 30 + 2336 W 1 097545 103 67 30 + 3536 W 1 497535 103 67 30 + 2336 W 1 095045 150 42 30 + 3636 W 1 097427 150 42 30 + 2936 W 1 097114 280 30 21 7236 W 1 097177 360 30 21 Switch Control + 8136 W 1 097144 360 30 21 1...10V 7736 W 2 097124 280 30 21 7436 W 2 097194 425 30 21 1...10V 7936 W 2 097187 430 30 21 Switch Control + 8138 W 1 097535 103 67 30 + 2338 W 1 097545 103 67 30 + 3538 W 1 497535 103 67 30 + 2338 W 1 095045 150 42 30 + 3658 W 1 097115 280 30 21 7358 W 1 097178 360 30 21 Switch Control 8158 W 1 097145 360 30 21 1...10V 7858 W 2 097125 280 30 21 7458 W 2 097195 425 30 21 1...10V 8058 W 2 097188 430 30 21 Switch Control 81

13

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Standard Lamp Holder GE Lighting Osram Philips Radium Sylvania

Power (W)

Number HÜCO No. Length(mm)

Width(mm)

Height(mm)

Interface Multipower-Technology

Page

Page 14: Lighting Electronics | 2007/08

14 Subject to technical modifications

List of numbers

HÜCO No. Description Page HÜCO Nr. Description Page095043 BL-HP 1/2 x 9-21W HS Twingle 33095044 BL-HP 1/2 x 18W TC-DEL/TEL HS Twingle 34095045 BL-HP 1/2 x 15-42W HS Twingle 36095232 BL 1x6-13W HMC Minipower 16095233 BL 1x7-13W HMC Minipower 17095234 BL 1x18W TC-DEL/TEL HMC Minipower 18095235 BL 1x22-26W TC-DEL/TEL HMC Minipower 19095238 BL 1x28W TC-DD HMC Minipower 26095243 BL 1x10-13W HMC Minipower i 20095244 BL 1x18W TC-DEL/TEL HMC Minipower i 21095613 BL-HP 1x35W HID HC3 83095617 BL-HP 1x70W HID HC3 83095623 BL-HP 1x35W HID HC3 2C 84095624 BL-HP 1x35W HID HC3 1C 84095627 BL-HP 1x70W HID HC3 2C 85095628 BL-HP 1x70W HID HC3 1C 85096001 DIMMER 60-750W A-DIM 90096217 BL 4-10W 12V 82096507 Multibox HMB 260 VPE 50 pcs 91096719 ET 6-WAY CONNECTOR 89096761 ET 20-70VA LE 86096816 ET 20-105VA LE/TE 86096835 ET 20-105VA LE „HANDY“ 87096851 ET 100-210VA LE 89096860 ET 50-150VA Le 88097039 BL-HP 1x55W TC-L MS2 31097058 BL-HP 2x55W TC-L MS2 31097078 BL-HP 1x55W TC-L MS A-DIM 71097079 BL-HP 1x55W TC-L MS3 A-DIM 45097088 BL-HP 2x55W TC-L MS A-DIM 71097089 BL-HP 2x55W TC-L MS3 A-DIM 49097113 BL-HP 1x18W T8 MS3 72097114 BL-HP 1x36W T8 MS3 72097115 BL-HP 1x58W T8 MS3 73097123 BL-HP 2x18W T8 MS3 73097124 BL-HP 2x36W T8 MS3 74097125 BL-HP 2x58W T8 MS3 74097143 BL-HP 1x18W T8 MS3 A-DIM 76097144 BL-HP 1x36W T8 MS3 A-DIM 77097145 BL-HP 1x58W T8 MS3 A-DIM 78097161 BL-HP 3/4x15-24W MS3 75097172 BL-HP 4x18W T26 MS A-DIM 81097176 BL-HP 1x18W T26 MS A-DIM 81097177 BL-HP 1x36W T26/TC-L MS A-DIM 81097178 BL-HP 1x58W T26 MS A-DIM 81097186 BL-HP 2x18W T26 MS A-DIM 81097187 BL-HP 2x36W T26/TC-L MS A-DIM 81097188 BL-HP 2x58W T26 MS A-DIM 81097193 BL-HP 2x18W T8 MS3 A-DIM 78097194 BL-HP 2x36W T8 MS3 A-DIM 79097195 BL-HP 2x58W T8 MS3 A-DIM 80097204 BL-HP 1x14-35W T5 MS2 56097206 BL-HP 1x24-40W T5 / TC-F/L MS2 57097207 BL-HP 1x49W T5 MS2 58097208 BL-HP 1x54W T5 MS2 58097209 BL-HP 1x55/80W T5 / TC-L MS2 59097214 BL-HP 2x14-35W T5 MS2 60097216 BL-HP 2x24-40W T5 / TC-F/L 61097217 BL-HP 2x49W T5 MS2 62097218 BL-HP 2x54W T5 MS2 62097244 BL-HP 1x14-35W T5 MS3 A-DIM 64097246 BL-HP 1x24/39W T5 MS3 A-DIM 65097247 BL-HP 1x49W T5 MS3 A-DIM 66097248 BL-HP 1x54W T5 MS3 A-DIM 66097249 BL-HP 1x80W T5/TC-L MS3 A-DIM 67097294 BL-HP 2x14-35W T5 MS3 A-DIM 68097296 BL-HP 2x24/39W T5 MS3 A-DIM 69

097297 BL-HP 2x49W T5 MS3 A-DIM 70097298 BL-HP 2x54W T5 MS3 A-DIM 70097361 BL-HP 4x14W T5 MS A-DIM 71097363 BL-HP 1x14W T16 MS A-DIM 71097364 BL-HP 1x21W T16 MS A-DIM 71097365 BL-HP 1x28W T16 MS A-DIM 71097366 BL-HP 1x35W T16 MS A-DIM 71097367 BL-HP 1x24W T16 MS A-DIM 71097368 BL-HP 1x39W T16 MS A-DIM 71097369 BL-HP 1x49W T16 MS A-DIM 71097370 BL-HP 1x54W T16 MS A-DIM 71097371 BL-HP 1x80W T16 MS A-DIM 71097373 BL-HP 2x14W T16 MS A-DIM 71097374 BL-HP 2x21W T16 MS A-DIM 71097375 BL-HP 2x28W T16 MS A-DIM 71097376 BL-HP 2x35W T16 MS A-DIM 71097377 BL-HP 2x24W T16 MS A-DIM 71097378 BL-HP 2x39W T16 MS A-DIM 71097379 BL-HP 2x49W T16 MS A-DIM 71097380 BL-HP 2x54W T16 MS A-DIM 71097381 BL-HP 3/4x14W T5 MS3 63097426 BL-HP 1x28W TC-DD HS 27097427 BL-HP 1x36-38W TC-DD HS 29097436 BL-HP 1x28W TC-DD HC 27097437 BL-HP 1x38W TC-DD HC 28097438 BL-HP 1x55W TC-DD HC 30097475 BL-HP 1x28W TC-DD HC A-DIM 44097477 BL-HP 1x38W TC-DD HC A-DIM 44097516 BL-HP 1x18-40W HC A-DIM 42097526 BL-HP 2x18/42W TC-L/F HC A-DIM 48097534 BL 1x18W TC-DEL/TEL HC 22097535 BL 1x15-42W HC 23097539 BL-HP 1x57W TC-TEL HC 24097540 BL-HP 1x70W TC-TEL HC 24097543 BL-HP 1/2 x 9-21W HC Twingle 32097544 BL-HP 1/2 x 18W TC-DEL/TEL HC Twingle 34097545 BL-HP 1x15-42W/2x15-26W HC Twingle 35097548 BL-HP 1/2 x 26-42W HC Twingle 37097555 BL-HP 2x18-40W HC 38097570 BL-HP 1x26-42W TC-DEL/TEL HC A-DIM 40097571 BL-HP 1x57/70W TC-TEL HC A-DIM 41097574 BL-HP 1x13W TC-DEL/TEL HC A-DIM 39097575 BL-HP 1x18W TC-DEL/TEL HC A-DIM 39097580 BL-HP 2x26-42W TC-DEL/TEL HC A-DIM 47097584 BL-HP 2x13W TC-DEL/TEL HC A-DIM 45097585 BL-HP 2x18W TC-DEL/TEL HC A-DIM 46097586 BL-HP 2x26W TC-DEL/TEL HC A-DIM 46097634 BL-HP 1x55W T5c HC 25097635 BL-HP 1x60W T5c HC 26097674 BL-HP 1x55W T5c TC A-DIM 43097675 BL-HP 1x60W T5c HC A-DIM 43097816 BL-HP 1x18-40W HC D-DIM 51097826 BL-HP 2x18/24W TC-L/F HC D-DIM 55097864 BL-HP 1x55W T5c/TC-L HC D-DIM 52097865 BL-HP 1x60W T5c HC D-DIM 52097870 BL-HP 1x26-42W TC-DEL/TEL HC D-DIM 50097875 BL-HP 1x18W TC-DEL/TEL HC D-DIM 49097880 BL-HP 2x26-42W TC-DEL/TEL HC D-DIM 54097885 BL-HP 2x18W TC-DEL/TEL HC D-DIM 53

Page 15: Lighting Electronics | 2007/08

www.hueco.com 15

3

5

Manual HÜCO Online-Catalogue

1At: www.products.hueco.bizyou enter our online catalogueLighting Electronics

2On this page you can search for the characteristics of the ballasts. Our example: Number of lamps: 1 Type of lamp: T5 Power: 21W

3In this page you can see all ballasts according to your selection. Select your preferred ballast

4You have reached the right ballast

Example: I search for an electronic Ballast: 1x21W T5

Page 16: Lighting Electronics | 2007/08

16

T5 6 W 0,06 A

T5 8 W 0,08 A

T5 13 W 0,11 A

EN 60929 EN 61000-3-2

W6 W 8 W 13 W

T5

4,270

224,240

60,47080

230 - 240 V~ 0/50...60 Hz 176 - 276 V -15°C...+55 °C 1A2 > 0,55c 80 x 40 x 22 mm ca. 38 g VDE, ENEC

T5

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp T5Power see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Alternative design to magenetic ballast• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Safe operation under emergency conditions 176-276V DC • Power reduction under DC conditions • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max. /ta max.• Lifetime 60.000h at ta = 45°C

Rated input current (230V)

Approved lamp combinations

Combination ENEC certified

Article Number: 09 5232

BL 1x6-13W HMC Minipower

Page 17: Lighting Electronics | 2007/08

www.hueco.com 17

TC-DEL 10 W 0,08 ATC-DEL 13 W 0,11 ATC-TEL 13 W 0,11 A

TC-SEL 7 W 0,06 ATC-SEL 9 W 0,08 ATC-SEL 11 W 0,11 A

W7 W 9 W 10 W 11 W 13 W 14W

TC-DEL TC-TEL TC-SELT5

EN 60929 EN 61000-3-2

4,270

224,240

60,47080

230 - 240 V~ 0/50...60 Hz 176 - 276 V -15°C...+55 °C 1A2/A3 > 0,55c 80 x 40 x 22 mm ca. 38 gVDE, ENEC

TC-SEL

TC-DELTC-TEL

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

• Alternative design to magenetic ballast• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Safe operation under emergency conditions 176-276V DC • Power reduction under DC conditions • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max. /ta max.• Lifetime 60.000h at ta = 45°C

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

Rated input current (230V)

Approved lamp combinations

Article Number: 09 5233

Combination ENEC certified

BL 1x7-13W HMC Minipower

Page 18: Lighting Electronics | 2007/08

18

4,270

224,240

60,47080

EN 60929 EN 61000-3-2

TC-DEL/TEL18W230 - 240 V~ 0/50...60 Hz 0,14 A176 - 276 V -15°C...+50 °C 1A2> 0,57c 80 x 40 x 22 mm ca. 40 g VDE, ENEC

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

• Alternative design to magenetic ballast• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Safe operation under emergency conditions 176-276V DC • Ignition time approx. 1,0 Sek.• Power reduction under DC conditions • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max. /ta max.• Lifetime 60.000h at ta = 40°C

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

Article Number: 09 5234

BL 1x18W TC-DEL/TEL HMC Minipower

Page 19: Lighting Electronics | 2007/08

www.hueco.com 19

4,270

224,240

60,47080

EN 60929 EN 61000-3-2

W22 W 24 W 26W

T5cTC-LTC-FTC-TELTC-DEL

TC-DEL/TEL 26 W 0,22 ATC-L/F 24 W 0,20 AT5c 22 W 0,20 A

230 - 240 V~ 0/50...60 Hz 0,14 A176 - 276 V -15°C...+50 °C 1A2> 0,55c 80 x 40 x 22 mm ca. 50 g VDE, ENEC, EMV

TC-DELTC-TEL

TC-LTC-F

T5c

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Alternative design to magenetic ballast• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Safe operation under emergency conditions 176-276V DC • Ignition time approx. 1,0 Sek.• Power reduction under DC conditions • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max. /ta max.• Lifetime 60.000h at ta = 40°C

Article Number: 09 5235

Rated input current (230V)

Approved lamp combinations

Combination ENEC certified

BL 1x22-26W TC-DEL/TEL HMC Minipower

Page 20: Lighting Electronics | 2007/08

20

W10 W 13 W

TC-DEL TC-TEL

TC-DEL 10 W 0,08 ATC-DEL 13 W 0,11 ATC-TEL 13 W 0,11 A

EN 60929 EN 61000-3-2

62

5,25

56

13,8

62

230 - 240 V~ 0/50...60 Hz 176 - 276 V -15°C...+50 °C 1A30,56c 62 mm56 mm ca. 70 gVDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorDiameterHeightWeightTest mark

• Minipower i, Ballast with (i)ntegrated lamp-holder• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Ignition time approx. 1,1 Sek. • Safe operation under emergency conditions 176-276V DC • Power reduction under DC conditions • Very good Energy classification (EEI) • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max./ ta max.• Lifetime 60.000h at ta = 40°C

Rated input current (230V)

Approved lamp combinations

Article Number: 09 5243

Combination approved

BL 1x10-13W HMC Minipower i

Page 21: Lighting Electronics | 2007/08

www.hueco.com 21

EN 60929 EN 61000-3-2

62

5,25

56

13,8

62

TC-DEL/TEL18W230 - 240 V~ 0/50...60 Hz 0,14 A176 - 276 V -15°C...+50 °C 1A2 0,57c 62 mm56 mm ca. 70 gVDE

TC-DELTC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

• Minipower i, Ballast with (i)ntegrated lamp-holder• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Ignition time approx. 0,9 Sek. • Safe operation under emergency conditions 176-276V DC • Power reduction under DC conditions • Very good Energy classification (EEI) • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max./ ta max.• Lifetime 60.000h at ta = 40°C

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorDiameterHeightWeightTest mark

Article Number: 09 5244

BL 1x18W TC-DEL/TEL HMC Minipower i

Page 22: Lighting Electronics | 2007/08

22

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,08 A176 - 276 V -20°C...+60 °C 1A20,96103 x 67 x 30 mmca. 115 g ENEC, VDE, EMV

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• HÜCO compact housing• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7534

BL-HP 1x18W TC-DEL/TEL HC

Page 23: Lighting Electronics | 2007/08

www.hueco.com 23

TC-DEL/TEL 26 W 0,12 A

TC-TEL 32 W 0,16 A

TC-TEL 42 W 0,21 A

TC-L/F 18 W 0,08 A

TC-L/F 24 W 0,11 A

TC-L/F 36 W 0,16 A

TC-L 40 W 0,19 A

T5c 22 W 0,11 A

T5c 40 W 0,19 A

T8 15 W 0,08 A

T8 18 W 0,09 A

T8 36 W 0,16 A

T8 38 W 0,17 A

T5 24 W 0,12 A

T5 39 W 0,17 A

T12 40 W 0,17 A

EN 60929 EN 61000-3-2

W15W 18W 22W 24W 26W 32W 36W 38W 39W 40W 42W

TC-DELTC-TELTC-FTC-LT5cT8T5T 12

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1 A2 0,96 103 x 67 x 30 mm ca. 120 g ENEC, VDE, EMV

TC-DELTC-TEL

TC-LTC-F

T5c

T5

T8T12

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• HÜCO compact housing• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Different connection possibilities for various lamps • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Corrosion ressistant version with lacquered circuit board Order number: 49 7535

Article Number: 09 7535

Approved lamp combinations

Combination approved Combination ENEC certified

Rated input current (230V)

BL-HP 1x15-42W HC

Page 24: Lighting Electronics | 2007/08

24

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

TC-TEL57W220 - 240 V~ 0/50...60 Hz 0,27 A176 - 276 V -20°C...+50 °C 1 A2 0,98 103 x 67 x 30 mm ca. 155 g ENEC, VDE, EMV

TC-TEL70W220 - 240 V~ 0/50...60 Hz 0,32 A176 - 276 V -20°C...+50 °C 1 A20,98 123 x 79 x 33 mm ca. 195 g ENEC, VDE

TC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification24

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG no dim

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7539

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

Article Number: 09 7540

BL-HP 1x57W TC-TEL HC BL-HP 1x70W TC-TEL HC

Page 25: Lighting Electronics | 2007/08

www.hueco.com 25

EN 60929 EN 61000-3-2

W55W

T5cTC-L

TC-L 55 W 0,26 AT5c 55 W 0,26 A

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+50 °C 1A2 0,98 103 x 67 x 30 mm ca. 150 g ENEC, VDE, EMV

TC-L

T5c

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Different connection possibilities for various lamps • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7634

Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

BL-HP 1x55W T5c/TC-L HC

Page 26: Lighting Electronics | 2007/08

26

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

EN 60929 EN 61000-3-2

4,270

224,240

60,47080

T5c60W220 - 240 V~ 0/50...60 Hz 0,28 A176 - 276 V -20°C...+50 °C 1A2 0,98 103 x 67 x 30 mm ca. 155 g ENEC, VDE, EMV

TC-DD28W230 - 240 V~ 0/50...60 Hz 0,24 A176 - 276 V -15°C...+50 °C 1A2> 0,55c 80 x 40 x 22 mm ca. 50 g VDE, ENEC, EMV

TC-DD

T5c

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification26

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG no dim

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7635

• Alternative design to magenetic ballast• Digital ASIC technology • Output stabilization at 207-254V AC • Lamp warm start and operation acc. to EN 60929 • Safe operation under emergency conditions 176-276V DC • Power reduction under DC conditions • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Harmonic wave limit acc. to EN 61000-3-2 • High spec components for a lifetime of 30.000h at tc max. /ta

max. • Lifetime 60.000h at ta = 40°C

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

Article Number: 09 5238

BL-HP 1x60W T5c HC BL 1x28W TC-DD HMC Minipower

Page 27: Lighting Electronics | 2007/08

www.hueco.com 27

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

30

4,342

140150

TC-DD28W220 - 240 V~ 0/50...60 Hz 0,12 A176 - 276 V -20°C...+60 °C 1 A2 0,97 103 x 67 x 30ca. 120 g ENEC, VDE

TC-DD T8*26W 30W220 - 240 V~ 0/50...60 Hz 0,12 A 0,13 A176 - 276 V -20°C...+60 °C 1 A2 0,97 150 x 42 x 30 mmca. 125 g ENEC, VDE

TC-DD

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

27

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Alternative design to magnetic ballast• Digital ASIC technology• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7426Article Number: 09 7436

BL-HP 1x28W TC-DD HC BL-HP 1x28W TC-DD HS

Page 28: Lighting Electronics | 2007/08

28

EN 60929 EN 61000-3-2

W36W 38 W

TC-DDTC-L TC-F

TC-DD 38 W 0,17 ATC-L 36 W 0,16 ATC-F 36 W 0,16 A

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1 A2 0,98 103 x 67 x 30 mm ca. 120 g ENEC, VDE

TC-LTC-F

TC-DD

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperatureNumber of lamps Energy classificationPower factor Length x Width x HeightWeight Test mark

• HÜCO compact housing• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7437

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

BL-HP 1x38W TC-DD HC

Page 29: Lighting Electronics | 2007/08

www.hueco.com 29

EN 60929 EN 61000-3-2

W36W 38 W

TC-DDTC-L TC-FT8

TC-DD 38 W 0,17 ATC-L 36 W 0,16 ATC-F 36 W 0,16 AT8 36W 0,15 A

30

4,342

140150

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1 A2 0,98 150 x 42 x 30 mm ca. 125 g ENEC, VDE

TC-LTC-F

TC-DD

T8

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Alternative design to magnetic ballast• Digital ASIC technology• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7427

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

BL-HP 1x36-38W HS

Page 30: Lighting Electronics | 2007/08

30

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

TC-DD55W220 - 240 V~ 0/50...60 Hz 0,25 A176 - 276 V -15°C...+50 °C 1 A20,95 123 x 79 x 33 mm ca. 190 g ENEC, VDE

TC-DD

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

LampPowerRated voltage Mains frequencyRated input currentD.C. voltage range Ambient temperature Number of lamps Energy classificationPower factor Length x Width x Height Weight Test mark

• HÜCO compact housing • Digital ASIC technology• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7438

BL-HP 1x55W TC-DD HC

Page 31: Lighting Electronics | 2007/08

www.hueco.com 31

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

TC-L55W220 - 240 V~ 0/50...60 Hz 0,27 A176 - 276 V -20°C...+55 °C 1A2 0,98 280 x 30 x 21 mm ca. 215 g ENEC, VDE

TC-L55W220-240 V~ 0/50...60 Hz 0,51 A0 - 0 V -20 - +50 C° 2 A2 0.98 360 x 30 x 21 mm 285 g ENEC, VDE

TC-L

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

31

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Article Number: 09 7039

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Fast and smooth lamp warm start within 1 second • HLC II circuit (HÜCO Lamp Control): Preheat of the cathodes and

the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss

• Reduced power losses, decrease self-heating of the ballast • Lifetime > 50.000 h at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the

ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring• EOL (end of life) Shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

Article Number: 09 7058

• Construction height just 21 mm • Fast and smooth lamp warm start within 1 second • HLC II circuit (HÜCO Lamp Control): Preheat of the cathodes and

the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss

• Reduced power losses, decrease self-heating of the ballast • Lifetime > 50.000 h at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect • Automatic restart once the lamp has been changed

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage rangeAmbient temperature Number of lamps Energieklasse Power factor Length x Width x HeightWeight Test mark

BL-HP 1x55W TC-L MS2 BL-HP 2x55W TC-L MS2

Page 32: Lighting Electronics | 2007/08

32

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

TC-SEL 1x9 W 0,05 ATC-SEL 1x11 W 0,06 ATC-DD 1x10 W 0,06 ATC-DD 1x16 W 0,07 A

TC-DEL 1x10 W 0,05 ATC-DEL/TEL 1x13 W 0,06 AT5 1x14 W 0,07 AT5 1x21 W 0,10 A

21

TC-SEL9W

T514 W

TC-TEL13W

TC-SEL11W

TC-DD16W

TC-DEL10W

TC-DD10W

TC-SEL 9WT5 14WTC-TEL 13WTC-SEL 11WTC-DD 16WTC-DEL 10WTC-DD 10W

W9W 10 W 11W 13W 14W 16W 21W

TC-SELTC-DEL TC-TELTC-DDT5

TC-SEL 2x9 W 0,09 ATC-SEL 2x11 W 0,12 ATC-DD 2x10 W 0,10 ATC-DD 2x16 W 0,14 A

TC-DEL 2x10 W 0,10 ATC-DEL/TEL 2x13 W 0,13 AT5 2x14 W 0,13 AT5 2x21 W 0,10 A

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1/2A2/A3 ca. 0,9103 x 67 x 30 mm ca. 135 g ENEC, VDE, EMV

TC-SEL

TC-DELTC-TEL

TC-DD

T5

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Replaces 097533/53

Article Number: 09 7543

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

Rated input current for double (230V)

BL-HP 1/2 x 9-21W HC Twingle

Page 33: Lighting Electronics | 2007/08

www.hueco.com 33

EN 60929 EN 61000-3-2

TC-SEL 1x9 W 0,05 ATC-SEL 1x11 W 0,06 ATC-DD 1x10 W 0,06 ATC-DD 1x16 W 0,07 A

TC-DEL 1x10 W 0,05 ATC-DEL/TEL 1x13 W 0,06 AT5 1x14 W 0,07 AT5 1x21 W 0,10 A

21

TC-SEL9W

T514 W

TC-TEL13W

TC-SEL11W

TC-DD16W

TC-DEL10W

TC-DD10W

TC-SEL 9WT5 14WTC-TEL 13WTC-SEL 11WTC-DD 16WTC-DEL 10WTC-DD 10W

W9W 10 W 11W 13W 14W 16W 21W

TC-SELTC-DEL TC-TELTC-DDT5

TC-SEL 2x9 W 0,09 ATC-SEL 2x11 W 0,12 ATC-DD 2x10 W 0,10 ATC-DD 2x16 W 0,14 A

TC-DEL 2x10 W 0,10 ATC-DEL/TEL 2x13 W 0,13 AT5 2x14 W 0,13 A

30

4,342

140150

Neu

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1/2A2/A3 ca. 0,9150 x 42 x 30 mm ca. 120 g ENEC, VDE

TC-SEL

TC-DELTC-TEL

TC-DD

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Article Number: 09 5043

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

Rated input current for double (230V)

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Different lamps can be operated at the same time• Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

New

Replaces 095033/53

BL-HP 1/2 x 9-21W HS Twingle

Page 34: Lighting Electronics | 2007/08

34

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

30

4,342

140150

Neu

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,08 A / 0,17 A176 - 276 V -20°C...+60 °C 1/2A2ca. 0,95103 x 67 x 30 mm ca. 135 gENEC, VDE, EMV

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,08 A / 0,17 A176 - 276 V -20°C...+60 °C 1/2A2ca. 0,95150 x 42 x 30 mm ca. 120 gENEC, VDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification34

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG no dim

LampPowerRated voltageMains frequencyRated input current Single / DoubleD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7544

Replaces 097554

LampPowerRated voltageMains frequencyRated input current Single / DoubleD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Different lamps can be operated at the same time• Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 5044

New

Replaces 095034/44

BL-HP 1/2x18W TC-DEL/TEL HC Twingle BL-HP 1/2x18W TC-DEL/TEL HS Twingle

Page 35: Lighting Electronics | 2007/08

www.hueco.com 35

1xTC-DEL/TEL 26 W 0,12 A1xTC-TEL 32 W 0,16 A1xTC-TEL 42 W 0,21 A1xTC-L 40 W 0,19 A1xT8 15 W 0,08 A1xT8 18 W 0,09 A1xT8 36 W 0,16 A1xT8 38 W 0,17 A

1xTC-L/F 18 W 0,08 A1xTC-L/F 24 W 0,11 A1xT5c 22 W 0,11 A1xT5c 40 W 0,19 A1xT5 24 W 0,12 A1xT5 39 W 0,17 A1xT12 40 W 0,17 A

21

T8 15W

T8 18W

T5 14W

T5c22W

TC-F24W

TC-L 24W

TC-TEL26W

TC-L18W

TC-F18W

TC-DEL26W

T8 15WT8 18WT5 14WT5c 22WTC-F 24WTC-L 24WTC-TEL 26WTC-L 18WTC-F 18WTC-DEL 26W

W15W 18W 22W 24W 26W 32W 36W 38W 39W 40W 42W

TC-DELTC-TELTC-FTC-LT5c T5 T8 T12

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

2xTC-DEL/TEL 26 W 0,24 A2xT8 15 W 0,15 A2xT8 18 W 0,16 A

2xTC-L/F 18 W 0,16 A2xTC-L/F 24 W 0,22 A2xT5c 22 W 0,22 A2xT5 24 W 0,24 A

EN 60929 EN 61000-3-2

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1/2A2 ca. 0,95 103 x 67 x 30 mm ca. 135 g ENEC, VDE, EMV

TC-DELTC-TEL

TC-LTC-F

T5c

T5

T8T12

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7545

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

Rated input current for double (230V)

BL-HP 1x15-42W/2x15-26W HC Twingle

Page 36: Lighting Electronics | 2007/08

36

1xTC-DEL/TEL 26 W 0,12 A1xTC-TEL 32 W 0,16 A1xTC-TEL 42 W 0,21 A1xTC-L 40 W 0,19 A1xT8 15 W 0,08 A1xT8 18 W 0,09 A1xT8 36 W 0,16 A1xT8 38 W 0,17 A

1xTC-L/F 18 W 0,08 A1xTC-L/F 24 W 0,11 A1xT5c 22 W 0,11 A1xT5c 40 W 0,19 A1xT5 24 W 0,12 A1xT5 39 W 0,17 A1xT12 40 W 0,17 A

21

T8 15W

T8 18W

T5 14W

T5c22W

TC-F24W

TC-L 24W

TC-TEL26W

TC-L18W

TC-F18W

TC-DEL26W

T8 15WT8 18WT5 14WT5c 22WTC-F 24WTC-L 24WTC-TEL 26WTC-L 18WTC-F 18WTC-DEL 26W

W15W 18W 22W 24W 26W 32W 36W 38W 39W 40W 42W

TC-DELTC-TELTC-FTC-LT5c T5 T8T12

2xTC-DEL/TEL 26 W 0,24 A2xT8 15 W 0,15 A2xT8 18 W 0,16 A

2xTC-L/F 18 W 0,16 A2xTC-L/F 24 W 0,22 A2xT5c 22 W 0,22 A2xT5 24 W 0,24 A

EN 60929 EN 61000-3-2

30

4,342

140150

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+60 °C 1/2A2 ca. 0,95 150 x 42 x 30 mm ca. 120 g ENEC, VDE

TC-DELTC-TEL

TC-LTC-F

T5c

T5

T8T12

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• „Twingle“ Usable with 1 or 2 lamps • Different lamps can be operated at the same time• Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

Rated input current for double (230V)

Article Number: 09 5045

New

Replaces 095035/55

BL-HP 1x15-42W/2x15-26W HS Twingle

Page 37: Lighting Electronics | 2007/08

www.hueco.com 37

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

W26 W 32 W 42W

TC-DEL TC-TEL

TC-DEL 26 W 0,14 ATC-TEL 26 W 0,14 A

21

TC-DEL26W

TC-TEL26W

TC-TEL32W

TC-TEL42 W

TC-DEL 26WTC-TEL 26WTC-TEL 32WTC-TEL 42W

TC-TEL 32 W 0,16 ATC-TEL 42 W 0,20 A

TC-DEL 26 W 0,24 ATC-TEL 26 W 0,24 A

TC-TEL 32 W 0,30 ATC-TEL 42 W 0,39 A

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20 °C...+50 °C 1/2A2 > 0,95c 123 x 79 x 33 mm ca. 180 g VDE, ENEC

TC-DELTC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

Article Number: 09 7548

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

Combination approved Combination ENEC certified

Rated input current (230V)

Approved lamp combinations

Rated input current for double (230V)

• „Twingle“ Usable with 1 or 2 lamps • Different lamps can be operated at the same time• Compact housing • Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

New

Replaces 097558

BL-HP 1/2x26-42 W HC

Page 38: Lighting Electronics | 2007/08

38

EN 60929 EN 61000-3-2

2xTC-DEL/TEL 26 W 0,24 A

2xTC-DEL/TEL 32 W 0,32 A

2xTC-L/F 18 W 0,16 A

2xTC-L/F 24 W 0,22 A

2xT5c 22 W 0,22 A

2xT5c 22/40 W 0,31 A

21

TC-DEL26W

TC-TEL26W

TC-TEL32W

T5c 22W

T5c40W

TC-L18W

TC-L24W

TC-L40W

TC-F18W

TC-F24W

TC-DEL 26W

TC-TEL 26W

TC-TEL 32W

T5c 22W

T5c 40W

TC-L 18W

TC-L 24W

TC-L 40W

TC-F 18W

TC-F 24W

27,533

994,5

111123

4,5

(129,5)

6779

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+50 °C 2 A2 0,95 123 x 79 x 33 mm ca. 180 g ENEC, VDE, EMV

TC-DELTC-TEL

TC-LTC-F

T5c

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Different lamps can be operated at the same time• HÜCO compact housing• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7555

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current for double (230V)

BL-HP 2x18-40W HC

Page 39: Lighting Electronics | 2007/08

www.hueco.com 39

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

TC-DEL/TEL13W220 - 240 V~ 0/50...60 Hz 0,07 A176 - 276 V +5°C...+60 °C 1 A1 0,97 1...10 V 0,15 mA 103 x 67 x 30 mm ca. 145 g ENEC, VDE

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,09 A176 - 276 V +5°C...+50 °C 1 A1 0,97 1...10 V 0,15 mA 103 x 67 x 30 mm ca. 140 g ENEC, VDE

TC-DELTC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

39

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Same housing as non-dimmable electronic ballast (103x67x30mm)• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7574

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Same housing as non-dimmable electronic ballast (103x67x30mm)• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7575

BL-HP 1x13W TC-DEL/TEL HC A-DIM BL-HP 1x18W TC-DEL/TEL HC A-DIM

Page 40: Lighting Electronics | 2007/08

40

EN 60929 EN 61000-3-2

TC-DEL 26 W 0,13 A

TC-TEL 26 W 0,13 A

TC-TEL 32 W 0,16 A

TC-TEL 42 W 0,21 A

W26W 32W 42W

TC-DEL

TC-TEL

TC-TEL

TC-TEL

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 1 A1 0,971...10 V 0,15 mA 103 x 67 x 30 mm ca. 145 g ENEC, VDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG,1...10V

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Same housing as non-dimmable electronic ballast (103x67x30mm)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed • Different connection possibilities for various lamps• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7570

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x26-42W TC-DEL/TEL HC A-DIM

Page 41: Lighting Electronics | 2007/08

www.hueco.com 41

EN 60929 EN 61000-3-2

TC-TEL 57 W 0,27 A

TC-TEL 70 W 0,32 A

W57W 70W

TC-TEL

27,533

994,5

111123

4,5

(129,5)

6779

TC-TEL57/70W220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 1 A1 0,981...10 V 0,15 mA 123 x 79 x 33 mm ca. 235 g ENEC, VDE

TC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Digital ASIC technology • Different connection possibilities for various lamps • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed • Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7571

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x57/70W TC-TEL HC A-DIM

Page 42: Lighting Electronics | 2007/08

42

EN 60929 EN 61000-3-2

T5c 22 W 0,11 A

T5c 40 W 0,19 A

TC-L/F 18 W 0,09 A

TC-L/F 24 W 0,12 A

W18W 22W 24W 40W

T5c

TC-F

TC-L

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 1 A1 0,981...10 V 0,15 mA 103 x 67 x 30 mm ca. 145 gENEC, VDE

TC-LTC-F

T5c

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG,1...10V

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Digital ASIC technology • Different connection possibilities for various lamps • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7516

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x18-40W HC A-DIM

Page 43: Lighting Electronics | 2007/08

www.hueco.com 43

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

T5c55W220 - 240 V~ 0/50...60 Hz 0,26 A176 - 276 V +5°C...+50 °C 1 A1 0,98 1...10 V 0,15 mA 123 x 79 x 33 mm ca. 200 g ENEC, VDE

T5c60W220 - 240 V~ 0/50...60 Hz 0,28 A176 - 276 V +5°C...+50 °C 1 A1 0,98 1...10 V 0,15 mA 123 x 79 x 33 mm ca. 200 g ENEC, VDE

T5c

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

43

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed • Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7674

• Digital ASIC technology • Different connection possibilities for various lamps • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed • Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7675

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

BL-HP 1x55W T5c HC A-DIM BL-HP 1x60W T5c HC A-DIM

Page 44: Lighting Electronics | 2007/08

44

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

EN 60929 EN 61000-3-2

4,293,5103

57,567

( )110

4,2

27,5 30

4,283.5

TC-DD28W220 - 240 V~ 0/50...60 Hz 0,13 A176 - 276 V +5°C...+50 °C 1 A1 0,98 1...10 V 0,15 mA 103 x 67 x 30 mm ca. 145 g ENEC, VDE

TC-DD38W220 - 240 V~ 0/50...60 Hz 0,17 A176 - 276 V +5°C...+50 °C 1 A1 0,98 1...10 V 0,15 mA 103 x 67 x 30 mm ca. 145 g ENEC, VDE

TC-DD

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification44

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed • Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7475

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Digital ASIC technology • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed • Flicker-free dimming from 100% to 3% • Controlled via 1-10V signal • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7477

BL-HP 1x28W TC-DD HC A-DIM BL-HP 1x38W TC-DD HC A-DIM

Page 45: Lighting Electronics | 2007/08

www.hueco.com 45

EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

EN 60929 EN 61000-3-2

TC-L55W220-240 V~ 0/50...60 Hz 0,27 A200 - 300 V +5°C...+50°C 1 A1 0.98 1...10V > 0.2 mA 360 x 30 x 21 mm 265 g ENEC, VDE

TC-DELTC-TEL

TC-L

TC-DEL/TEL13W220 - 240 V~ 0/50...60 Hz 0,13 A176 - 276 V +5°C...+50 °C 2 A1 0,98 1...10 V 0,15 mA 123 x 79 x 33 mm ca. 200 g ENEC, VDE

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

45

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7584Article Number: 09 7079

LampPowerRated voltage Mains frequencyRated input currentD.C. voltage range Ambient temperature Number of lamps Energieklasse Power factor Interface Interface current Length x Width x HeightWeight Test mark

New

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

BL-HP 2x13W TC-DEL/TEL HC A-DIMBL-HP 1x55W TC-L MS3 A-DIM

Page 46: Lighting Electronics | 2007/08

46

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779 27,533

994,5

111123

4,5

(129,5)

6779

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,17 A176 - 276 V +5°C...+50 °C 2 A1 0,97 1...10 V 0,15 mA 123 x 79 x 33 mm ca. 220 g ENEC, VDE

TC-DEL/TEL26W220 - 240 V~ 0/50...60 Hz 0,24 A176 - 276 V +5°C...+50 °C 2 A1 0,97 1...10 V 0,15 mA 123 x 79 x 33 mm ca. 225 g ENEC, VDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification46

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7585

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lampsEnergy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7586

BL-HP 2x18W TC-DEL/TEL HC A-DIM BL-HP 2x26W TC-TEL/DEL HC A-DIM

Page 47: Lighting Electronics | 2007/08

www.hueco.com 47

EN 60929 EN 61000-3-2

2xTC-DEL 26 W 0,24 A

2xTC-TEL 26 W 0,24 A

2xTC-TEL 36 W 0,31 A

2xTC-TEL 42 W 0,40 A

21

TC-DEL26W

TC-TEL26W

TC-TEL32W

TC-TEL42W

TC-DEL 26W

TC-TEL 26W

TC-TEL 32W

TC-TEL 42W

90

110,5122,6

4,5101

,6 (142.5)

4,5

27,332,

8

4,599

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 2 A1 0,981...10 V 0,15 mA 123 x 102 x 33 mm ca. 260 g ENEC, VDE

TC-DELTC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

Lamp TC-DEL/TELPower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lampsEnergy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Different connection possibilities for various lamps• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7580

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 2x26-42W TC-TEL/DEL HC A-DIM

Page 48: Lighting Electronics | 2007/08

48

EN 60929 EN 61000-3-2

2xTC-L 18 W 0,17 A

2xTC-L 24 W 0,23 A

2xTC-F 18 W 0,17 A

2xTC-F 24 W 0,23 A

21

TC-L18W

TC-L24W

TC-F18W

TC-F24W

TC-L 18W

TC-L 24W

TC-F 18W

TC-F 24W

27,533

994,5

111123

4,5

(129,5)

6779

TC-L/F18/24W220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 2 A1 0,981...10 V 0,15 mA 123 x 79 x 33 mm ca. 225 g ENEC, VDE

TC-LTC-F

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG,1...10V

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Active harmonic wave filter enables constant power output across a wide input range• Digital ASIC technology • Different connection possibilities for various lamps • Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Different connection possibilities for various lamps• Flicker-free dimming from 100% to 3%• Controlled via 1-10V signal• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7526

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 2x18/24W TC-L/F HC A-DIM

Page 49: Lighting Electronics | 2007/08

www.hueco.com 49

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779

TC-L55W220 - 240 V~ 0/50...60 Hz 0,54 A176 - 276 V +5°C...+50 °C 2 A1 0,97 1...10 V > 0,2 mA 425 x 30 x 21 mm ca. 350 g ENEC, VDE

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,09 A176 - 276 V +5°C...+50 °C 1A10,97 DALI123 x 79 x 33 mm ca. 175 gENEC, VDE

TC-DELTC-TEL

TC-L

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

49

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG,1...10V

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Interface current Length x Width x HeightWeight Test mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7089

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorInterface Length x Width x HeightWeightTest mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7875

NewBL-HP 2x55W TC-L MS3 A-DIM BL-HP 1x18W TC-DEL/TEL HC D-DIM

Page 50: Lighting Electronics | 2007/08

50

EN 60929 EN 61000-3-2

TC-DEL 26 W 0,13 A

TC-TEL 26 W 0,13 A

TC-TEL 32 W 0,16 A

TC-TEL 42 W 0,21 A

W26W 32W 42W

TC-DEL

TC-TEL

27,533

994,5

111123

4,5

(129,5)

6779

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 1A10,97DALI123 x 79 x 33 mm ca. 175 g ENEC, VDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECGDALI

Lamp TC-DEL/TELPower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Length x Width x HeightWeight Test mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Different connection possibilities for various lamps• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7870

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x26-42W TC-DEL/TEL HC D-DIM

Page 51: Lighting Electronics | 2007/08

www.hueco.com 51

EN 60929 EN 61000-3-2

T5c 22 W 0,11 A

T5c 40 W 0,19 A

TC-L/F 18 W 0,09 A

TC-L/F 24 W 0,12 A

W18W 22W 24W 40W

T5c

TC-F

TC-L

27,533

994,5

111123

4,5

(129,5)

6779

220 - 240 V~ 0/50...60 Hz 0,09 A176 - 276 V +5°C...+50 °C 1A10,98DALI123 x 79 x 33 mm ca. 175 g

TC-LTC-F

T5c

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECGDALI

Lamp see tablePower see tableRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorInterface Length x Width x HeightWeight

• DALI Interface with extended over voltage protection • Microprocessor controlled • Different connection possibilities for various lamps • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3% • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7816

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x18-40W HC D-DIM

Page 52: Lighting Electronics | 2007/08

52

EN 60929 EN 61000-3-2 EN 60929 EN 61000-3-2

27,533

994,5

111123

4,5

(129,5)

6779 27,533

994,5

111123

4,5

(129,5)

6779

T5c, TC-L55W220 - 240 V~ 0/50...60 Hz 0,26 A176 - 276 V +5°C...+50 °C 10,98A1DALI123 x 79 x 33 mm ca. 200 g ENEC, VDE

T5c60W220 - 240 V~ 0/50...60 Hz 0,28 A176 - 276 V +5°C...+50 °C 10,98A1DALI123 x 79 x 33 mm ca. 200 g ENEC, VDE

TC-L

T5c

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification52

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECGDALI

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsPower factorEnergy classificationInterfaceLength x Width x HeightWeightTest mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Different connection possibilities for various lamps• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7864

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsPower factorEnergy classificationInterfaceLength x Width x HeightWeightTest mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Different connection possibilities for various lamps• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition,• No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7865

BL-HP 1x55W T5c/TC-L HC D-DIM BL-HP 1x60W T5c HC D-DIM

Page 53: Lighting Electronics | 2007/08

www.hueco.com 53

EN 60929 EN 61000-3-2

90

110,5122,6

4,5101

,6 (142.5)

4,5

27,332,

8

4,599

TC-DEL/TEL18W220 - 240 V~ 0/50...60 Hz 0,17 A176 - 276 V +5°C...+50 °C 2 A1 0,98DALI123 x 102 x 33 mm ca. 245 g ENEC, VDE

TC-DELTC-TEL

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECGDALI

LampPowerRated voltageMains frequencyRated input currentD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorInterface Length x Width x HeightWeightTest mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition• No stroboscopic effects and flicker-free during operation• No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7885

BL-HP 2x18W TC-DEL/TEL HC D-DIM

Page 54: Lighting Electronics | 2007/08

54

EN 60929 EN 61000-3-2

2xTC-DEL 26 W 0,24 A

2xTC-TEL 26 W 0,24 A

2xTC-TEL 32 W 0,32 A

2xTC-TEL 42 W 0,40 A

21

TC-DEL26W

TC-TEL26W

TC-TEL32W

TC-TEL42W

TC-DEL 26W

TC-TEL 26W

TC-TEL 32W

TC-TEL 42W

90

110,5122,6

4,5101

,6 (142.5)

4,5

27,332,

8

4,599

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 2 A1 0,98DALI123 x 102 x 33 mm ca. 255 g ENEC, VDE

TC-DELTC-TEL

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECGDALI

Lamp TC-DEL/TELPower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Interface Length x Width x HeightWeight Test mark

• DALI Interface with extended over voltage protection• Microprocessor controlled• Different connection possibilities for various lamps• Optimal lamp operating by HLC technology (HÜCO Lamp Control)• Active harmonic wave filter enables constant power output across a wide input range• Reduced power losses, decrease self-heating of the ballast• Flicker-free ignition, no irritating noise• No stroboscopic effects and flicker-free during operation• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3%• Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7880

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 2x26-42W TC-DEL/TEL HC D-DIM

Page 55: Lighting Electronics | 2007/08

www.hueco.com 55

EN 60929 EN 61000-3-2

2xTC-L 18 W 0,17 A

2xTC-L 24 W 0,23 A

2xTC-F 18 W 0,17 A

2xTC-F 24 W 0,23 A

21

TC-L18W

TC-L24W

TC-F18W

TC-F24W

TC-L 18W

TC-L 24W

TC-F 18W

TC-F 24W

90

110,5122,6

4,5101

,6 (142.5)

4,5

27,332,

8

4,599

220 - 240 V~ 0/50...60 Hz 176 - 276 V +5°C...+50 °C 2 A1 0,98DALI123 x 102 x 33 mm ca. 245 g ENEC, VDE

TC-LTC-F

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECGDALI

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorInterface Length x Width x HeightWeightTest mark

• DALI Interface with extended over voltage protection • Microprocessor controlled • Different connection possibilities for various lamps • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Automatic restart once the lamp has been changed• Flicker-free dimming from 100% to 3% • Common dimming of electronic ballasts possible in spite of being splitted into different circuits • Lamp warm start and operation acc. to EN 60929 • Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7826

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 2x18/24W TC-L/F HC D-DIM

Page 56: Lighting Electronics | 2007/08

56

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

T5 14 W 0,08 A

T5 21 W 0,10 A

T5 28 W 0,14 A

T5 35 W 0,17 A

W14W 21W 28W 35W

T5

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

220 - 240 V~ 0/50...60 Hz 176-276 V -20°C...+55 °C 1 A2 0,95c280 x 30 x 21 mm ca. 200 g ENEC, VDE

TC-L

T5

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T5 ECGno dim

Lamp T5Power see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Multi power function for T5 and TC-L lamps• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect. • Automatic restart once the lamp has been changed

Article Number: 09 7204

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x14-35W T5 MS2

Page 57: Lighting Electronics | 2007/08

www.hueco.com 57

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

T5 24 W 0,17 A

T5 39 W 0,19 A

TC-L/F 36 W 0,15 A

TC-L/F 40 W 0,19 A

W24W 36W 39W 40W

T5

TC-L

TC-F

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

220 - 240 V~ 0/50...60 Hz 176-276 V -20°C...+55 °C 1A2 0,98c280 x 30 x 21 mm ca. 200 g ENEC, VDE

TC-L

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECGno dim

Lamp T5Power see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Multi power function for T5 and TC-L lamps• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect. • Automatic restart once the lamp has been changed

Article Number: 09 7206

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x24-40W T5/TC-F/L MS2

Page 58: Lighting Electronics | 2007/08

58

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

T5 49W220 - 240 V~ 0/50...60 Hz 0,24 A176 - 276 V -20°C...+55 °C 1 A20,98c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T554W220 - 240 V~ 0/50...60 Hz 0,26 A176 - 276 V -20°C...+55 °C 1A2 0,98c 280 x 30 x 21 mm ca. 215 g ENEC, VDE

TC-L

T5

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification58

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T5 ECGno dim

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLänge x Breite x HeightWeight Test mark

Article Number: 09 7207

• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect. • Automatic restart once the lamp has been changed

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect• Automatic restart once the lamp has been changed

Article Number: 09 7208

BL-HP 1x49W T5 MS2 BL-HP 1x54W T5 MS2

Page 59: Lighting Electronics | 2007/08

www.hueco.com 59

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

T5 80 W 0,38 A

TC-L/F 55 W 0,27 A

TC-L/F 80 W 0,38 A

W80W 55W

T5

TC-L

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+55 °C1 A20,98c280 x 30 x 21 mm ca. 215 g ENEC, VDE

TC-L

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECGno dim

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Multi power function for T5 and TC-L lamps• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic

Lamp wiring• EOL ( end of life ) Shut down of ballast at lamp end of

Life or defect. • Automatic restart once the lamp has been changed

Article Number: 09 7209

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 1x55/80W T5/TC-L MS2

Page 60: Lighting Electronics | 2007/08

60

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

2xT5 14 W 0,15 A

2xT5 21 W 0,21 A

2xT5 28 W 0,28 A

2xT5 35 W 0,34 A

21

T5 14W

T5 21W

T5 28W

T535W

T5 14W

T5 21W

T5 28W

T5 35W

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+55 °C 2A2 0,95c 360 x 30 x 21 mm ca. 270 g ENEC, VDE

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T5 ECGno dim

Lamp T5Power see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

• 100% Light independent from mains voltage fluctuations• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect• Automatic restart once the lamp has been changed

Article Number: 09 7214

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP 2x14-35W T5 MS2

Page 61: Lighting Electronics | 2007/08

www.hueco.com 61

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

2xT5 24 W 0,23 A

2xT5 39 W 0,34 A

2xTC-L/F 36 W 0,30 A

2xTC-L/F 40 W 0,38 A

21

T524W

T5 39W

TC-L36W

TC-L40W

TC-F36W

TC-F40W

T5 24WT5 39WTC-L 36WTC-L 40WTC-F 36WTC-F 40W

220 - 240 V~ 0/50...60 Hz 176 - 276 V -20°C...+55 °C2A20,98c360 x 30 x 21 mm ca. 270 g ENEC, VDE

TC-LTC-F

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECGno dim

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Multi power function for T5 and TC-L lamps• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic

Lamp wiring• EOL ( end of life ) Shut down of ballast at lamp end of

Life or defect. • Automatic restart once the lamp has been changed

Article Number: 09 7216

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL-HP EVG-HP 2x24-40W T5/TC-F/L MS2

Page 62: Lighting Electronics | 2007/08

62

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

T549W220 - 240 V~ 0/50...60 Hz 0,47 A176 - 276 V -20°C...+55 °C2A2 0,98c 360 x 30 x 21 mm ca. 285 g ENEC, VDE

T554W220 - 240 V~ 0/50...60 Hz 0,50 A176 - 276 V -20°C...+50 °C2A20,98c360 x 30 x 21 mm ca. 285 g ENEC, VDE

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification62

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T5 ECGno dim

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classification Power factor Length x Width x HeightWeight Test mark

Article Number: 09 7217

• 100% Light independent from mains voltage fluctuations• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect• Automatic restart once the lamp has been changed

LampPowerRated voltage Mains frequency Rated input currentD.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• 100% Light independent from mains voltage fluctuations• Fast and smooth lamp warm start within 1 second • HLC II Schaltung (HÜCO lamp control), Preheat of the cathodes and the operation of the lamp circuit run independently from each other, thereby ensuring very little impact from lamp tolerances and a very low power loss• Reduced power losses, decreased self-heating of the ballast• Lifetime > 50.000 h at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection For the ballast • Suitable for emergency light fittings in accordance with VDE 0108• Universal terminal blocks for manual and automatic Lamp wiring• EOL (end of life) Shut down of ballast at lamp end of Life or defect• Automatic restart once the lamp has been changed

Article Number: 09 7218

BL-HP 2x49W T5 MS2 BL-HP 2x54W T5 MS2

Page 63: Lighting Electronics | 2007/08

www.hueco.com 63

HVP HLC IILAMP CONTROL EN 60929 EN 61000-3-2

0,3

0,3

4,2

4,239

270

5,4

4,2

9

270

280

4,2

2112,89

10

9

8

7

1

2

3

4

5

6

10

9

8

7

1

2

3

4

5

6

T514W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C3/4A20,96c280 x 39 x 21 mm ca. 240 g ENEC, VDE

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECGno dim

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Construction height just 21 mm • Alternative fixing via side-installation • Very flat connection clamps permit easy installation in flat lamps • Active harmonic wave filter enables constant power output across a

wide input range• Reduced power losses, decrease self-heating of the ballast • Flicker-free ignition • No stroboscopic effects and flicker-free during operation • No irritating noise• Lamp warm start and operation acc. to EN 60929 • Very good Energy classification (EEI) • Also usable for 3 lamps• Harmonic wave limit acc. to EN 61000-3-2

Article Number: 09 7381

New

Wiring scheme 3-lamps

Wiring scheme 4-lampsReplaces 097262

BL-HP 3/4x14W T5 MS3

Page 64: Lighting Electronics | 2007/08

64

HVP

EN 60929 EN 61000-3-2

1xT5 14 W 0,08 A

1xT5 21 W 0,12 A

1xT5 28 W 0,15 A

1xT5 35 W 0,19 A

W14W 21W 28W 35W

T5

T5

T5

T5

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,96 c360 x 30 x 21 mm ca. 255 g ENEC, VDE

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T5 ECG1...10V

New

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7244

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

BL-HP 1x14-35W T5 MS3 A-DIM

Page 65: Lighting Electronics | 2007/08

www.hueco.com 65

HVP

EN 60929 EN 61000-3-2

1xT5 24 W 0,12 A

1xT5 39 W 0,17 A

W24W 39W

T5

T5

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,98 c360 x 30 x 21 mm ca. 255 g ENEC, VDE

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

New

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7246

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

BL-HP 1x24/39W T5 MS3 A-DIM

Page 66: Lighting Electronics | 2007/08

66

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T549W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,96 c360 x 30 x 21 mm ca. 255 g ENEC, VDE

T554W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,95 c360 x 30 x 21 mm ca. 265 g ENEC, VDE

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification66

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

NewNew

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7247 Article Number: 09 7248

BL-HP 1x49W T5 MS3 A-DIM BL-HP 1x54W T5 MS3 A-DIM

Page 67: Lighting Electronics | 2007/08

www.hueco.com 67

HVP

EN 60929 EN 61000-3-2

1xT5 80 W 0,37 A

1xTC-L 80 W 0,37 A

W80W 80W

T5

TC-L

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,95 c360 x 30 x 21 mm ca. 300 g ENEC, VDE

TC-L

T5

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

New

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7249

BL-HP 1x80W T5/TC-L MS3 A-DIM

Page 68: Lighting Electronics | 2007/08

68

HVP

EN 60929 EN 61000-3-2

2xT5 14 W 0,15 A

2xT5 21 W 0,21 A

2xT5 28 W 0,28 A

2xT5 35 W 0,35 A

21

T514W

T521W

T528W

T535W

T5 14W

T5 21W

T5 28W

T5 35W

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 320 g ENEC, VDE

T5

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T5 ECG1...10V

New

Lamp see tablePower see tableRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7294

BL-HP 2x14-35W T5 MS3 A-DIM

Page 69: Lighting Electronics | 2007/08

www.hueco.com 69

HVP

EN 60929 EN 61000-3-2

2xT5 24 W 0,23 A

2xT5 39 W 0,34 A

21

24W 39W

T5

T5

T524W, 39W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 320 g ENEC, VDE

T5

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

New

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7296

BL-HP 2x24/39W T5 MS3 A-DIM

Page 70: Lighting Electronics | 2007/08

70

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T549W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 350 g ENEC, VDE

T554W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 350 g ENEC, VDE

T5

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification70

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

NewNew

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

LampPowerRated voltage Mains frequency D.C. voltage range Ambient temperature Number of lamps Energy classificationPower factorLength x Width x HeightWeight Test mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lamp warm start and operation acc. to EN 60929• Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7297 Article Number: 09 7298

BL-HP 2x49W T5 MS3 A-DIM BL-HP 2x54W T5 MS3 A-DIM

Page 71: Lighting Electronics | 2007/08

www.hueco.com 71

4,5 30

350360

4,521

30

420430

4,54,5

21

4,5 4,5

420

TC-L

T5

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T5 ECG1...10V

Pow

er [

W]

Art.

Nr.

Num

ber

of

lam

ps

Rate

d vo

ltage

[V~

]

Mai

ns

freq

uenc

y[H

z]

Rate

d cu

rren

t[A

]

D.C

. vol

tage

ra

nge

[V]

Ambi

ent

tem

-pe

ratu

re [

°C]

Ener

gy c

lass

ifi-

catio

n (E

EI)

Pow

er f

acto

r

Inte

rfac

e

Inte

rface

cur

rent

ty

p. [m

A]

Leng

th x

Wid

th

x H

eigh

t [m

m]

Wei

ght

[g]

14 09 7363 1 220...240 0/50...60 0,08 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28521 09 7364 1 220...240 0/50...60 0,11 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28524 09 7367 1 220...240 0/50...60 0,16 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28528 09 7365 1 220...240 0/50...60 0,16 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28535 09 7366 1 220...240 0/50...60 0,18 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28539 09 7368 1 220...240 0/50...60 0,19 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28549 09 7369 1 220...240 0/50...60 0,24 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28554 09 7370 1 220...240 0/50...60 0,27 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28580 09 7371 1 220...240 0/50...60 0,38 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 285

14 09 7373 2 220...240 0/50...60 0,14 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36521 09 7374 2 220...240 0/50...60 0,21 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36524 09 7377 2 220...240 0/50...60 0,22 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36528 09 7375 2 220...240 0/50...60 0,27 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36535 09 7376 2 220...240 0/50...60 0,34 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36539 09 7378 2 220...240 0/50...60 0,38 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36549 09 7379 2 220...240 0/50...60 0,48 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36554 09 7380 2 220...240 0/50...60 0,51 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 365

14 09 7361 4 220...240 0/50...60 0,29 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 365

Ballasts for TC-L

36 09 7177 1 220...240 0/50...60 0,16 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28540 09 7368 1 220...240 0/50...60 0,18 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28555 09 7078 1 220...240 0/50...60 0,28 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28536 09 7187 2 220...240 0/50...60 0,30 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36540 09 7378 2 220...240 0/50...60 0,26 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36555 09 7088 2 220...240 0/50...60 0,54 176...276 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 365

• Dimmable with push button (SWITCH CONTROL)• Flicker-free dimming from 100% to 1% • Construction height just 21 mm • Alternative fixing via side-installation • Very flat connection clamps permit easy installation in flat lamps • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • No stroboscopic effects and flicker-free during operation • No irritating noise• Common dimming of electronic ballasts possible in spite of being splitted into different circuits

Ballasts for T5 SWITCH CONTROL

Ballasts for TC-L SWITCH CONTROL

EN 60929 EN 61000-3-2

Technical drawing for 1x ballasts

Technical drawing for 2x/4x ballasts

Page 72: Lighting Electronics | 2007/08

72

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T818W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C1A2≥ 0,96 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T836W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C1A2≥ 0,98 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T8

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification72

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T8 ECGno dim

Article Number: 09 7113

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

Article Number: 09 7114

BL-HP 1x18 T8 MS3 BL-HP 1x36W T8 MS3

Page 73: Lighting Electronics | 2007/08

www.hueco.com 73

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T858W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C1A2≥ 0,98 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T818W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C2A2≥ 0,97 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T8

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

73

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T8 ECGno dim

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

Article Number: 09 7115 Article Number: 09 7123

BL-HP 1x58W T8 MS3 BL-HP 2x18W T8 MS3

Page 74: Lighting Electronics | 2007/08

74

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T836W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C2A2≥ 0,97 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T858W220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C2A2≥ 0,98 c280 x 30 x 21 mm ca. 200 g ENEC, VDE

T8

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

0,3

0,3

4,2

4,230

270

5,4

4,2

9

270

280

4,2

2112,89

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification74

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

T8 ECGno dim

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

• Very compact housing: height only 21 mm, length only 280 mm • Active harmonic wave filter enables constant power output across a

wide input range • Reduced power losses, decreased self-heating of the ballast • Flicker-free during operation • No irritating noise • Lamp warm start and operation acc. to EN 60929 • Fast and smooth lamp warm start within 1 second • Alternative fixing via side-installation. • 100 % light independent from mains voltage fluctuations • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed

Article Number: 09 7124 Article Number: 09 7125

BL-HP 2x36W T8 MS3 BL-HP 2x58W T8 MS3

Page 75: Lighting Electronics | 2007/08

www.hueco.com 75

3xT5 24 W 0,33 A

3xT8 15 W 0,21 A

3xT8 18 W 0,25 A

3xTC-L/F 18 W 0,23 A

3xTC-L/F 24 W 0,32 A

W15W 18W 24W

T5 3x

T8 3x

TC-L/F 3x

T8 4x

TC-L/F 4x

HVP

EN 60929 EN 61000-3-2

4xT8 15 W 0,28 A

4xT8 18 W 0,31 A

4xTC-L/F 18 W 0,29 A

220 - 240 V~ 0/50...60 Hz 176...276 V -20°C...+55 °C3/4A2≥ 0,95 c280 x 39 x 21 mm ca. 240 g ENEC, VDE

TC-LTC-F

T5

T8

0,3

0,3

4,2

4,239

270

5,4

4,2

9

270

280

4,2

2112,89

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

T8 ECGno dim

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Very compact housing: height only 21 mm, length only 280 mm • Lamp warm start and operation acc. to EN 60929 • Optimal lamp operating by HLC technology (HÜCO Lamp Control) • Reduced power losses, decreased self-heating of the ballast • Lifetime > 50,000 hours at tc max / ta max • HVP (HÜCO Voltage Protection) high overvoltage protection for the

ballast • Suitable for emergency light fittings in accordance with VDE 0108 • Universal terminal blocks for manual and automatic lamp wiring • EOL (end of life) shut down of ballast at lamp end of life or defect

Article Number: 09 7161

New

Approved lamp combinations

Rated input current (230V)

BL-HP 3/4x15-24W MS3

Page 76: Lighting Electronics | 2007/08

76

HVP

EN 60929 EN 61000-3-2

T818W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,96 c360 x 30 x 21 mm ca. 255 g ENEC, VDE

T8

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T8 ECG1...10V

New

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7143

BL-HP 1x18W T8 MS3 A-DIM

Page 77: Lighting Electronics | 2007/08

www.hueco.com 77

HVP

EN 60929 EN 61000-3-2

1xT8 36 W 0,16 A

1xTC-L/F 36 W 0,16 A

1xTC-L 40 W 0,21 A

W36W 36W 40W

T8

TC-L/F

TC-L

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,98 c360 x 30 x 21 mm ca. 255 g ENEC, VDE

TC-LTC-F

T8

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing T8 ECG1...10V

New

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

Article Number: 09 7144

BL-HP 1x36W T8 MS3 A-DIM

Page 78: Lighting Electronics | 2007/08

78

HVP

EN 60929 EN 61000-3-2

HVP

EN 60929 EN 61000-3-2

T858W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C1A1≥ 0,95 c360 x 30 x 21 mm ca. 265 g ENEC, VDE

T818W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 320 g ENEC, VDE

T8

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

350 ±0,3

360

350 ±0,3

Ø4,2

30

4,2

Ø4,2

21 12,8 9 9

4,2

5,4

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification78

Technical Data

Product Highlights

Additional Product Highlights

Technical DrawingT8 ECG1...10V

NewNew

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7145 Article Number: 09 7193

BL-HP 1x58W T8 MS3 A-DIM BL-HP 2x18W T8 MS3 A-DIM

Page 79: Lighting Electronics | 2007/08

www.hueco.com 79

HVP

EN 60929 EN 61000-3-2

2xT8 36 W 0,31 A

2xTC-L/F 36 W 0,31 A

2xTC-L 40 W 0,38 A

21

T836W

TC-L/F36W

TC-L40W

T8 36W

TC-L/F 36W

TC-L 40W

220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 320 g ENEC, VDE

TC-LTC-F

T8

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing T8 ECG1...10V

New

Lamp see tablePower see tableRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Multipower technology, one ballast for several lamps and/or per-formances

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7194

BL-HP 2x36W T8 MS3 A-DIM

Page 80: Lighting Electronics | 2007/08

80

HVP

EN 60929 EN 61000-3-2

T858W220 - 240 V~ 0/50...60 Hz 176...276 V +5°C...+50 °C2A1≥ 0,97 c425 x 30 x 21 mm ca. 325 g ENEC, VDE

T8

415 ±0,3

425

30

Ø4

,2

4,2

21 12,8 9

Ø4,2415 ±0,3

5,4

4,2

9

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

T8 ECG1...10V

New

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsEnergy classificationPower factorLength x Width x HeightWeightTest mark

• Flicker-free dimming from 100% to 1%• Controlled via 1-10V signal• Construction height just 21 mm • Digital ASIC Technology• Flicker-free during operation • Lifetime > 50,000 hours at tc max / ta max• HVP (HÜCO Voltage Protection) high overvoltage protection for the ballast• EOL (end of life) shut down of ballast at lamp end of life or defect • Automatic restart once the lamp has been changed• Universal terminal blocks for manual and automatic lamp wiring • Reduced power losses, decreased self-heating of the ballast

Article Number: 09 7195

BL-HP 2x58W T8 MS3 A-DIM

Page 81: Lighting Electronics | 2007/08

www.hueco.com 81

EN 60929 EN 61000-3-2

T8(T26)

4,5 30

350360

4,521

30

420430

4,54,5

21

4,5 4,5

420

TC-L

T8

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing T8 ECG1...10V

• Dimmable with push button (SWITCH CONTROL)• Flicker-free dimming from 100% to 1% • Construction height just 21 mm • Alternative fixing via side-installation • Very flat connection clamps permit easy installation in flat lamps • Active harmonic wave filter enables constant power output across a wide input range • Reduced power losses, decrease self-heating of the ballast • No stroboscopic effects and flicker-free during operation • No irritating noise• Common dimming of electronic ballasts possible in spite of being splitted into different circuits

Pow

er [

W]

Art.

Nr.

Num

ber

of

lam

ps

Rate

d vo

ltage

[V~

]

Mai

ns

freq

uenc

y[H

z]

D.C

. vol

tage

ra

nge

[V]

Ambi

ent

tem

-pe

ratu

re [

°C]

Ener

gy c

lass

ifi-

catio

n (E

EI)

Pow

er f

acto

r

Inte

rfac

e

Inte

rfac

e cu

rren

t ty

p. [

mA]

Leng

th x

Wid

th

x H

eigh

t[m

m]

Wei

ght

[g]

18 09 7176 1 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28536* 09 7177 1 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 28558 09 7178 1 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 360 x 30 x 21 ca. 285

18 09 7186 2 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36536** 09 7187 2 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 36558 09 7188 2 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 365

18 09 7172 4 220...240 0/50...60 200...300 +10...+50 A1 0,98 Switch Ctrl. 0,8 430 x 30 x 21 ca. 365

W36W

T8

TC-L/F

ENEC approved

*Approved lamp combinations

21

T836W

TC-L/F36W

T8 36W

TC-L/F 36W

ENEC approved

**Approved lamp combinations

Technical drawing for 1x ballasts

Technical drawing for 2x/4x ballasts

EVG for T8 SWITCH CONTROL

Page 82: Lighting Electronics | 2007/08

82

T5 4 W 0,44 A

T5 6 W 0,63 A

T5 8 W 0,78 A

W4W 6W 7W 8W 9W 10W

T5

TC-SEL

TC-DEL

TC-SEL 7 W 0,68 A

TC-SEL 9 W 0,82 A

TC-DEL 10 W 0,89 A

29

6.3x0.8 (2x)

82

4,5

DC10,5 - 14,5 V -10°C...+50 °C 1182 x 40 x 29 mm ca. 65 g

TC-SEL

TC-DEL

T5

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

ECG no dim

Lamp see tablePower see tableMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x HeightWeight

• For 12V applications (11.5 - 14.5V) • Compact housing• Geringes Weight• No stroboscopic effects and flicker-free during operation• No irritating noise• Different connection possibilities for various lamps• Lamp warm start

Article Number: 09 6217

Combination approved Combination ENEC certified

Approved lamp combinations

Rated input current (230V)

BL 4-10W 12V

Page 83: Lighting Electronics | 2007/08

www.hueco.com 83

HID35 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID70 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

83

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

Article Number: 09 5613

• ECG for high intensity discharge lamps (HID) • Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minutes

• ECG for high intensity discharge lamps (HID) • Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minute

Article Number: 09 5617

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

NewNew BL-HP 1x70W HID HC3BL-HP 1x35W HID HC3

Page 84: Lighting Electronics | 2007/08

84

HID35 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID35 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification84

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

ECG no dim

NewNew

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

• ECG for high intensity discharge lamps (HID) • Pre converted version with 1x cable and plug for lamp• Pre converted version with 1x cable and plug for mains• Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minutes

• ECG for high intensity discharge lamps (HID) • Pre converted version with 1x cable and plug for lamps• Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minute

Article Number: 09 5623 Article Number: 09 5624

BL-HP 1x35W HID HC3 C1BL-HP 1x35W HID HC3 C2

Page 85: Lighting Electronics | 2007/08

www.hueco.com 85

HID70 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID70 W220 - 240 V~ 50/60 Hz 176 - 276 V -20 °C...+60 °C 1> 0,97c 139,8 x 87,2 x 39 mm

HID

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

85

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

ECG no dim

NewNew

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

LampPowerRated voltageMains frequencyD.C. voltage rangeAmbient temperatureNumber of lampsPower factorLength x Width x Height

• ECG for high intensity discharge lamps (HID) • Pre converted version with 1x cable and plug for lamp• Pre converted version with 1x cable and plug for mains• Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minutes

• ECG for high intensity discharge lamps (HID) • Pre converted version with 1x cable and plug for lamp• Lifetime min. 50.000 houres at Tc max. • Lamp lifetime 10.000 houres • Steady lamp performances by mains fluctuations and lamp tole-

rances • Preservation of the colour lamp temperature • Short-circuit protection on the secondary side • Over-temperature protection • Independent housing with strain relief • The ECG is suitable for loop wiring • Also available as pre converted version (see 095623 and 095624) • Restart after cut-off time of 20 minute

Article Number: 09 5627 Article Number: 09 5628

BL-HP 1x70W HID HC3 C1BL-HP 1x70W HID HC3 C2

Page 86: Lighting Electronics | 2007/08

86

429

3,4

4,225 61 64

54627076 160

30

125

4,4

40

äquivalent

20-70W230 V~50...60 Hz 0,99C 20...70 VA11,4 V~ eff295 mAca. 3,5 kHz64 x 70 x 29 mmca. 3,2 W-20°C...+50°Cca. 85 g

20-105W230 -240 V~50...60 Hz0,99L, C20/50...105VA11,8 V ~ eff460 mA35 kHz160 x 40 x 30 mmca. 5 W-20°C...+50°Cca. 150 g

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification86

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Trans-former

PowerNetzspannungMains frequencyPower factorDimmer load indicationLoad rangeSecondary voltageRated currentOperating frequencyLength x Width x HeightPower lossesAmbient temperatureWeight

• Light weight • Short-circuit, overload and over-temperature protection • Open circuit protection• Reduced power losses, decrease self-heating of the ballast• Soft start maximises lamp life• Dimmable with trailing edge dimmer• Constant voltage for complete load range• Complies to all relevant standards• Dimmer compatibility load indication• Small compact housing, for build in into luminaires

Article Number: 09 6761

PowerNetzspannungMains frequencyPower factorDimmer load indicationLoad range Secondary voltageRated currentOperating frequencyLength x Width x HeightPower lossesAmbient temperatureWeight

• Suitable for leading and trailing edge dimmers Trailing edge dimmer: Load range 20...105W Leading edge dimmer: Load range 50...105W

• Loop in loop out primary connection • 3 lamp connection on secondary• Light weight • Short-circuit, overload and over-temperature protection • Open circuit protection • Reduced power losses, decrease self-heating of the ballast • Soft start maximises lamp life • Constant voltage for complete load range • Output voltage 11.8V at 240V input • Complies to all relevant standards • Dimmer compatibility load ind

Article Number: 09 6816

ET 20-70VA LE ET 20-105VA LE/TE

Page 87: Lighting Electronics | 2007/08

www.hueco.com 87

57 128

max. 2

8 49

23

í 3.5 76.6

äquivalent

20-105W230 - 240 V~50...60 Hz 0,99C 20...105 VA12 V ~ eff460 mAca. 46 kHz128 x 49 x 28 mmca. 6 W-20°C...+50°Cca. 115 g

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

Trans-former

PowerRated VoltageMains frequencyPower factorDimmer load indicationLoad rangeSecondary voltageRated currentOperating frequencyLength x Width x HeightPower lossesAmbient temperatureWeight

• Light weight • Short-circuit, overload and over-temperature protection • Open circuit protection • Reduced power losses, decrease self-heating of the ballast• Soft start maximises lamp life • Dimmable with trailing edge dimmer • For difficult installation conditions (fits through a ceiling opening of

58 mm with a - restricted height of 28 mm ) • Complies to all relevant standards • Dimmer compatibility load indication

Article Number: 09 6835

Fits through a ceiling opening of 58 mm with a restiricted height of 28 mm, max. thickness of ceiling 12 mm.

ET 20-105VA LE ‚HANDY‘

Page 88: Lighting Electronics | 2007/08

88

5

4.3 45

4.3 187

220

40

50-150W230 - 240 V~50...60 Hz0,99C50...150 VA12 V ~ eff650 mA42 kHz220 x 45 x 40 mmca. 7 W-20°C...+50°Cca. 245 g

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

Trans-former

PowerRated VoltageMains frequencyPower factorDimmer load indicationLoad rangeSecondary voltageRated currentOperating frequencyLength x Width x HeightPower lossesAmbient temperatureWeight

• Output voltage 12V ~ eff• Light weight • Open circuit protection • Reduced power losses, decrease self-heating of the ballast• Soft start maximises lamp life• Dimmable with trailing edge dimmer• Constant voltage for complete load range• Loop in loop out primary connection • 3 lamp connection on secondary • Complies to all relevant standards• Dimmer compatibility load indication

Article Number: 09 6860

ET 50-150VA LE

Page 89: Lighting Electronics | 2007/08

www.hueco.com 89

5

4.3 45

4.3 187

220

40 36

18.6

3.5

3.7 63.5 103

xx x x x x x x x x x x x x x

x x x x x x x x x x x x x

100-210W230 V~ 50...60 Hz0,99C100...210 VA11,3 V ~ eff930 mA33 kHz220 x 45 x 40 mmca. 9,4 W-20°C...+50°Cca. 295 g

max. 210W12 V~0-210 VA12 V -20°C...+50 °CJa Ja 63,5 x 36 x 19 mm ca. 9 g

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

89

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

Trans-former

• Light weight • Short-circuit, overload and over-temperature protection • Open circuit protection • Reduced power losses, decrease self-heating of the ballast • Soft start maximises lamp life • Dimmable with trailing edge dimmer • Constant voltage for complete load range • Loop in loop out primary connection • Complies to all relevant standards • Dimmer compatibility load indication

PowerRated VoltageMains frequencyPower factorDimmer load indicationLoad rangeSecondary voltageRated currentOperating frequencyLength x Width x HeightPower lossesAmbient temperatureWeight

Article Number: 09 6851

PowerRated voltageLoad rangeOutput voltageAmbient temperature Trailing edgeLeading edgeLength x Width x HeightWeight

• Light weight • Compact housing • 6 fully shrouded terminals for protection agianst accidental contact

(max. 2,5mm²)• max. 100W per connection (12V) or I=8.5A • max. 210W total load (12V) oder I=17.5A • Can also be used with conventional transformers, provided that they

are protected on sec. Side

Article Number: 09 6719

ET 6-WAY CONNECTORET 100-210VA LE

Page 90: Lighting Electronics | 2007/08

90

Dimmer 5

4.3 45

4.3 187

220

40

DIMMER 60-750W A-DIM

Dimmable Ballast

230 V~ 50 Hz 750 W 60 W -20°C...+40 °CR,C 1...10V 220 x 45 x 40 mm ca. 235 g

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

Rated voltageMains frequencyMaximum loadMinimum loadAmbient temperature Dimmer load markingInterfaceLength x Width x HeightWeight

• Flicker-free dimming • Load range (60-750W at a temperature of 40°C at each dimmer) • High-voltage halogen and incandescent lamps are also dimmable

(60-500W) • Reduced power losses, decrease self-heating of the ballast • Simple control via built-in 1-10V interface, potentiometer, manual

control devices, photosensors, etc. • Capable of dimming halogen and fluorescent lamps via a 1-10 V

dimmer • Dimmers can be linked via 1-10V interface to increase dimming

capability, with each dimmer connected to different mains circuits • Short-circuit, overload and over-temperature protection • Dimmer compatibility load indication• Important notice: When operating the phase-cut dimmer (750W) in

full load, you have to observe that the power loss of transformers has to be taken into consideration.

Rated power + power loos < 750W Example application

Wiring diagram

Article Number: 09 6001

Page 91: Lighting Electronics | 2007/08

www.hueco.com 91

Product Highlights

Technical Data

Additional Product Highlights

Technical Drawing

Supplies

• Glow-wire test: 850°C • Housing material: PC ABS • Conductor cross-section: from 2 x 0,75 mm² to 5 x 1,5 mm² • Area for a product writing or for a label is present • Optimize installation time• A hanging installation is also possible • Independent housing fits for all HÜCO standard high performance

ballasts (103x67x30, 123x79x33, 129x102x33) • With 4 cable implementations • With 4 screwless strain reliefs

* Ballasts and cables not included

Article Number: 09 6507

Multibox HMB 260 packaging unit 50 pcs.*

Mentre A ≥ 100 mm → B ≥ 160 mmMentre A ≥ 200 mm → B ≥ 125 mm

Page 92: Lighting Electronics | 2007/08

92

Technical Data

Product Highlights

Additional Product Highlights

Technical Drawing

Subject to technical modification

Supplies

• Disconnection-tool, for disconnecting of the wiring from the plug-in terminal (WAGO serial 251-3. .)

• To disconnect a concuctor bring the tool between the conductor and the clip

• Including 2 spare blades in the housing • Until you hear a quiet „click-sound“

Article Number: -

• Easy connection of the conductor with a connection tool • Time-saving wiring with the IDC contact • Fast and easy wiring also in pre mounted luminaires, without strip-

ping the insulation of the conductor

Article Number: -

Press-in tool for IDC contactDisconnection tool

Product Highlights

Page 93: Lighting Electronics | 2007/08

www.hueco.com 93

Various markings of electronic control gear

ENEC test markThe new European safety mark for lamps is valid in the whole of Europe. The related number between 1 and 16 refers to the respective testing laboratory, the 10 to the VDE.

VDE test markProducts that carry this VDE symbol meet the safety requirements according to EN 61046 (transformers) or EN 60928 (electronic ballasts).

VDE-EMV test markFor equipment, which corresponds to the standards for electromagnetic compatibility (EMV, disturbance transmis-sion, immunity from disturbance).

Independent ConvertorThe transformer can be fitted outside the lamps without an additional housing.

Non-inherently short-circuit proof convertorShort-circuit proof convertor which incorporates a protec-tive device which opens the circuit or reduces the current in the input circuit or the output circuit when the convertor is overloaded or short-circuited.

Class II Luminaires in accordance with EN 60598An earth connection is not required.

A temperature - protected convertorThe overtemperature protection ensures that the housing temperature stipulated in the triangle is not exceeded even in unusual operating conditions. An earth connection is not required.

SELV (Safety Extra Low Voltage) SELV - formerly known as protective extra-low voltage is now mentioned as extra-low voltage against electric shock. SELV is considered protection class III according to DIN EN 61140 (VDE 0140-1). This means with SELV there is no earth wire. Metal housings may not be earthed and voltage must be extra-low.

Maximum recommended temperature refers to that at the case tc point

Maximum recommended ambient temperature (°C)

May be fitted on wood in accordance with DIN VDE 0710 T 14

Establishing of ballasts in energy efficiency classes

A3 = Electronic ballastA2 = Electronic ballast with reduced lossesA1 = Dimmable electronic ballast

CE Symbol The CE Symbol is not a test mark but simply declares that the product complies with EC guidelines. Compliance is the responsibility of the individual manufacturers and does not affect National Product or Safety standards. The CE Symbol refers in particular to interference emissions and immunity of the equipment. The CE Symbol is compulsory from 01. January 1996.

Active power factor correctionDevices bearing this symbol have the following advan-tages:• Active harmonic wave filter • Power factor approximately 1 • Fully electronic circuit system • current consumption almost sinusoidal • little distortions of the rated current • Total harmonics typ. <10% • values fall clearly below the limits acc. to EN 61000-3-2• Constant Power Output • Regular lighting level because of input voltages in the range of 198 V to 254 V• Wide range of input voltage • the same luminous flux in case of AC/DC • may be fitted to emergency lighting (VDE 0108)• Interference Suppression • acc. to EN 55015

Multipower Electronic BallastWith these elecetonic ballasts it is possible to operate dif-ferent lamps and/or different wattages.

HLC HLC - Hüco Lamp ControlSee page 112

HLC 2 - Hüco Lamp Control IIUnterschiede zu HLC: Kürzere Vorheizzeit der T5 EVG, sowie die Energieklassifizierung A2 wird eingehalten

EN 60929

Lamp operation according to EN 60929

EN 61000-3-2

Line current harmonics according to EN 61000-3-2

HVP - Hüco Voltage ProtectionBrief tension firmness to 350V, against overvoltage at the net entrance.

End of LifeTurning off with lamp defect and at the lamp end of life.

C-TickDevices carrying this symbol correspond to the Australian and New Zealand EMV standards. The marking must con-tain the approval number (Approval NO. NSWxxxxx) and the supplier number (Supplier code No. Nxxxx). Both num-bers have to be shown on he product.

A part of the HÜCO products carries this certification. Further devices will follow.

S&E

China Compulsory CertificationSince August 1st 2003 a variety of goods imported to china have to pass „China Compulsory Certification“. The Chinese certification authority CNCA has published a list of affected tariff numbers. Goods concerning to these published tariff numbers may not be imported to china.

A part of the HÜCO products carries this certification. Further devices will follow..

Page 94: Lighting Electronics | 2007/08

94 Subject to technical modification

Light Output / Lamp PowerThe High Frequency operation achieves the stated light output at a 10% lower lamp power. (ill. EVG 2)

Luminous Flux DropA lower luminous flux drop is achieved throughout the entire life of the lamp due to High Frequency operation in contrast to conventional operating systems.

High Frequency OperationAs lamps react very quickly when 50 Hz current is being used, there is the usual flickering due to the fact that each time the voltage is zero on the sine-wave, the lamp has to be restarted. When HÜCO ballasts are used the flickering of the lamp will be reduced by more than 90%. Flickering and stroboscopic effects are barely notice-able.

Start ProcessWarm start : These ballasts have a warm start which ensures the ignition of thelamps is preceded by optimal preheating of the electrodes. This type ofballast is for areas where the light has to be frequently switched on andoff or where this option is desirable (more than 5 cycles per day)

Power LossThere is approximately 75% less power loss with HÜCO ballasts in com-parison to conventional ballasts.

Energy balance by the example 1x58W T8

Magnetic ballast:Lamp power 58W, Ballast losses 13W, Total circuit power 71W

Low loss magnetic ballast:Lamp power 58W, Ballast losses 8W, Total circuit power 70W

HÜCO electronic ballast:Lamp power 50W, (with same light output), Ballast losses 4W, Total circuit power 56W

HÜCO electronic ballast + daylight sensor:Total circuit power 35W (average)

HÜCO EVG + daylight sensor + PIR sensor:Total circuit power 28W (average)

Fully electronic ballasts have a high energy saving potential in compari-son to conventional ballasts. This is due to the following factors:• up to 25% lower system load• up to 50% longer lamp life due to high frequency operation• reduced maintenance costs due to longer periods between

replacements• reduced airconditioning costs due to savings in power loss• reduced connection charges due to the smaller system loading for

the same light output

Further AdvantagesThe fully electronic construction of HÜCO ballasts offers a series of sig-nificant performance advantages with regard to lighting quality, lighting comfort and safety of operation:• no flickering and no noise when the light is switched on and in

operation• operating with direct current voltage is permitted; i.e. may be fitted

to safety and emergency lighting in accordance with VDE 0108• no stroboscopic effects with rotating machines• reduced luminous flux loss during the complete life span of the

lamp due to high frequency operation• reduced self-heating due to minimal losses• automatically restarts once the lamp has been changed• conventional ballasts can emit noise around the audible thres-hold, HÜCO ballasts almost run noiseless

Interference SuppressionHÜCO ballasts meet EMC guide-lines.

WeightDepending on the rating HÜCO ballasts weigh between ca. 40 and ca. 400 gms. This, along with their compact design, makes them extremely suitable for fitting into suspended ceilings, or cramped and restricted spaces.

D.C. Voltage OperationHÜCO ballasts are suitable for DC operation. The voltage range in which ignition can be guaranteed depends on the configuration of the ballast. Further information can be found on the product description pages. May be used for emergency lighting applications in accordance with VDE 0108. Extra costs for emergency needs are not incurred.The battery load is significantly smaller when a HÜCO ballast is used in contrast to conventional emergency lighting systems. This means either a longer emergency lighting time or a smaller battery design. Please notice that HÜCO ballasts got a programmed start. After mains interrup-tion the restart time will be 1,5s in any case. The ballast are not suitable for emergency application with restart in less then 1,5s.

Lamp Life SpanDue to the stable operation at High Frequency Voltage, the lamp load is lower. This results in a longer lifespan of the lamp by up to 50% and thereby a reduction in purchase, replacement and maintenance costs.

Constant Power OutputHÜCO electronic ballasts with an active harmonic wave filter (Active PFC) ensure a constant power output in the range of 198V to 254V and guarantee a regular lighting level irrespective of voltage fluctuations. As a result there is a constant power supply to the lamp, thus contributing to the increased life of the lamp. (ill. EVG 1)

Voltage SupplyHÜCO electronic ballasts are suitable for all European mains voltages from 220V - 240V.

Savings by use of electronic Ballasts

MB LLMB EB EB+ EB++-7% -25% -50% -60%

Page 95: Lighting Electronics | 2007/08

www.hueco.com 95

220 V 240 V230 V

100%

Prel.110%

90%

2.

U

1.

100%

105%

110%

50 500 5000 50000 Hz

1 2 3

4

1

2

34

1

2

3

4

Relative Systempower of 2 x T8 58W1. Conventional ballast in dual circuit Ballast 2. HÜCO Electronic Ballasts

Relative light outputL-Lamp light output as a function of the supply voltage at constant load

RFI Filter PFC HF-Amplifier

Control

Block wiring diagram

Savings by use of electronic Ballasts

RFI filter:Noise suppression acc. to EN 55015Immunity acc. to EN 61547

PFC:harmonics acc. to EN 61000-3-2Sinusoidal line current, high power factor power constance

HF-Amplifier:Operation of lamps acc. to EN 60929Secureness ignition, good pre-heating

Control:Safety acc. to EN 60928End of life detection of lamps, monitoring of mains voltage, PFC, HF-Amplifier

Supply Voltage

Page 96: Lighting Electronics | 2007/08

96 Subject to technical modification

For several years HÜCO has utilised ‘HLC’ technology (HÜCO Lamp Control) in dimmable electronic ballasts. Due to its superior perfor-mance this technology is also incorporated in the new generation of Multi-Power ballasts.

1. HÜCO electronic ballast with ’HLC’ techniqueThe ’HLC’ technology makes it possible that the ignition circuit is quasi switched off after ignition of the lamp. The lamp current is then distributed to both ends of the cathode.

Advantages:

• Due to the distribution of the lamp current to both cathodes, the temperature is distributed equally. In comparison to other Cut-off technologies the thermal stress at the cathodes is lower and cathodes failures rates are minimized.

• The cathode voltage drop at the lamp is reduced. The result is a lower lamp current without loss of luminous flux:

The comparisonWe asked an independent lamp manufacturer to compare the HÜCO ’HLC’ technology with an electronic ballast with preheating cut-off, in order to have verifiable figures for these statements. In the test HÜCO Multi-Power ballast 09 7555 2x18–32 W and a comparable ballast with cut-off technology were used. The most widely used ballast type, 2x26W TC-TEL, was tested.

The table below shows that the HÜCO ballast with a lamp power of 23,8 W provides a luminous flux of 1754 lumen. This means in comparison: 1 Watt lower lamp losses at a higher luminous flux! Or in other words: At nearly the same luminous flux a lower lamp current of 13 mA!

The effect is that the lamp is not used at such high temperatures and therefore has a longer life-span and can be used for various difficult applications. Reference measurements by HÜCO customers can verify this!

These measurements show the advantage of the HÜCO „HLC“ technology:

• Higher efficiency of luminosity

• Lower power loss

• Higher efficiency

L [lm] P [W] Im/W Ud [V] Id [A]

HÜCO ballast with HLC 1754 23,8 73,8 79,1 0,302

Ballast with preheating cut-off

1740 24,8 70,2 78,7 0,316

Measurements with TC-DEL 26W; average value from measurements with 6 lamps;

Ta = 25°C

L [lm] - luminous flux in lumen

P [W] - lamp power in Watt

lm/W - efficiency lumen per Watt

Ud [V] - lamp voltage. in Volt

Id [A] - lamp current in Ampere

2. Electronic ballast with preheating cut-offIf you consider this technique, the preheating circuit is cut off after ignition of the lamp and the complete lamp current flows into one end of the cathode. This technology is identical with the operation of a lamp at a KVG or a WG.(Wire wound)

Vorteile: Simple circuit for the limitation of power loss.

Nachteile: The complete lamp current is conducted by one cathode pin and therefore the cathode is heated up on one side. The ensuing ther-mal stress could result in failure of the cathode. The cathode vol-tage drop at the lamp increases, as a consequence the efficiency of the lamp decreases.

HLC Technology(HÜCO Lamp Control)

Page 97: Lighting Electronics | 2007/08

www.hueco.com 97

Max. number of ballasts at miniature circuit breaker 1-pin type B with 16 ampere

Art. No. DescriptionMax No.

Art. No. DescriptionMax No.

Notice!

Conversion for other types of miniature circuit breakers

Type B, 16 A 100 % (look at table above)Type B, 10 A 63%Type C, 16 A 170%Type C, 10 A 104%

• At 2- or 3-pin circuit breakers the max. numbers are reduced by 20%

• The actual number depends strongly on the net reactance • The data refer to Siemens N-circuit breakers

Max. number of ballasts atminiature circuit breaker

095043 BL-HP 1/2x9-21W HS Twingle 23

095044 BL-HP 1/2x18W TC-DEL/TEL HS Twingle 23

095045 BL-HP 1x15-42W/2x15-26W HS 23

095232 BL 1x6-13W HMC Minipower 28

095233 BL 1x7-13W HMC Minipower 28

095234 BL 1x18W TC-DEL/TEL HMC Minipower 28

095235 BL 1x22-26W TC-DEL/TEL HMC Minipower 28

095238 BL 1x28W TC-DD HMC Minipower 28

097039 BL-HP 1x55W TC-L MS2 19

097058 BL-HP 2x55W TC-L MS2 16

097078 BL-HP 1x55W TC-L MS A-DIM 19

097088 BL-HP 2x55W TC-L MS A-DIM 16

097113 BL-HP 1x18W T8 MS3 30

097114 BL-HP 1x36W T8 MS3 30

097115 BL-HP 1x58W T8 MS3 28

097123 BL-HP 2x18W T8 MS3 28

097124 BL-HP 2x36W T8 MS3 28

097125 BL-HP 2x58W T8 MS3 12

097161 BL-HP 3/4x15-24W T8 MS3 28

097172 BL-HP 4x18W T26 MS A-DIM 19

097176 BL-HP 1x18W T26 MS A-DIM 47

097177 BL-HP 1x36W T26/TC-L MS A-DIM 27

097178 BL-HP 1x58W T26 MS A-DIM 15

097186 BL-HP 2x18W T26 MS A-DIM 27

097187 BL-HP 2x36W T26/TC-L MS A-DIM 15

097188 BL-HP 2x58W T26 MS A-DIM 10

097204 BL-HP 1x14-35W T5 MS2 30

097206 BL-HP 1x24-40W T5 / TC-F/L MS2 28

097207 BL-HP 1x49W T5 MS2 28

097208 BL-HP 1x54W T5 MS2 28

097209 BL-HP 1x55/80W T5 / TC-L MS2 15

097214 BL-HP 2x14-35W T5 MS2 28

097216 BL-HP 2x24-40W T5 / TC-F/L 15

097217 BL-HP 2x49W T5 MS2 15

097218 BL-HP 2x54W T5 MS2 15

097361 BL-HP 4x14W T5 MS A-DIM 20

097363 BL-HP 1x14W T16 MS A-DIM 52

097364 BL-HP 1x21W T16 MS A-DIM 42

097365 BL-HP 1x28W T16 MS A-DIM 29

097366 BL-HP 1x35W T16 MS A-DIM 27

097367 BL-HP 1x24W T16 MS A-DIM 37

097368 BL-HP 1x39W T16 MS A-DIM 26

097369 BL-HP 1x49W T16 MS A-DIM 17

097370 BL-HP 1x54W T16 MS A-DIM 15

097371 BL-HP 1x80W T16 MS A-DIM 13

097373 BL-HP 2x14W T16 MS A-DIM 28

097374 BL-HP 2x21W T16 MS A-DIM 22

097375 BL-HP 2x28W T16 MS A-DIM 20

097376 BL-HP 2x35W T16 MS A-DIM 15

097377 BL-HP 2x24W T16 MS A-DIM 24

097378 BL-HP 2x39W T16 MS A-DIM 14

097379 BL-HP 2x49W T16 MS A-DIM 11

097380 BL-HP 2x54W T16 MS A-DIM 10

097381 BL-HP 3/4x14W T5 MS3 25

097426 BL-HP 1x28W TC-DD HS 28

097427 BL-HP 1x36-38W HS 28

097436 BL HP 1x28W TC-DD HC 28

097437 BL-HP 1x38W TC-DD HC 28

097438 BL-HP 1x55W TC-DD HC 23

097475 BL-HP 1x28W TC-DD HC A-DIM 28

097477 BL-HP 1x38W TC-DD HC A-DIM 28

097516 BL-HP 1x18-40W HC A-DIM 28

097526 BL-HP 2x18/24W TC-L/F HC A-DIM 23

097534 BL-HP 1x18W TC-DEL/TEL HC 28

097535 BL-HP 1x15-42W HC 28

097539 BL-HP 1x57W TC-TEL HC 23

097540 BL-HP 1x70W TC-TEL HC 23

097543 BL-HP 1x/2x9-21W HC Twingle 23

097544 BL-HP 1x/2x18W TC-DEL/TEL HC Twingle 23

097545 BL-HP 1x/2x15-42W HC Twingle 23

097548 BL-HP 1/2 x 26-42W HC Twingle 23

097555 BL-HP 2x18-40W HC 23

097570 BL-HP 1x26-42W TC-DEL/TEL HC A-DIM 28

097571 BL-HP 1x57/70W TC-TEL HC A-DIM 23

097574 BL-HP 1x13W TC-DEL/TEL HC A-DIM 28

097575 BL-HP 1x18W TC-DEL/TEL HC A-DIM 28

097580 BL-HP 2x26-42W TC-DEL/TEL HC A-DIM 23

097584 BL-HP 2x13W TC-DEL/TEL HC A-DIM 28

097585 BL-HP 2x18W TC-DEL/TEL HC A-DIM 28

097586 BL-HP 2x26W TC-TEL/DEL HC A-DIM 23

097634 BL-HP 1x55W T5c/TC-L HC 23

097635 BL-HP 1x60W T5c HC 23

097674 BL-HP 1x55W T5c TC A-DIM 23

097675 BL-HP 1x60W T5c HC A-DIM 23

097816 BL-HP 1x18-40W HC D-DIM 28

097826 BL-HP 2x18/24W TC-L/F HC D-DIM 23

097864 BL-HP 1x55W T5c/TC-L HC D-DIM 23

097865 BL-HP 1x60W T5c HC D-DIM 23

097870 BL-HP 1x26-42W TC-DEL/TEL HC D-DIM 23

097875 BL-HP 1x18W TC-DEL/TEL HC D-DIM 28

097880 BL-HP 2x26-42W TC-DEL/TEL HC D-DIM 23

097885 BL-HP 2x18W TC-DEL/TEL HC D-DIM 23

Page 98: Lighting Electronics | 2007/08

98 Subject to technical modification

Advantages of HÜCO, tried and tested circuit technology• Flicker-free dimming • Hüco electronic ballasts, increase efficiency, reduce lamp

changes,and disposal costs• Warm start enhances lamp life• Flicker-free, high frequency operation• Active electronic power factor correction PFC• Integrated performance regulator for constant output• Increased lamp life due to high frequency operation• „Stand-by“- operation when the lamp is defective• Due to the fully electronic circuit there is no irritating noise• Meets national and international standards thereby ensuring

reliability

ApplicationHÜCO dimmable ballasts are designed for the operation of standard lamps.

ControlControl is via an isolated 1-10 V/DC interface. Connection by cables firm against by mains rated cables voltage.(Interface not in accordance with SELV)Consequently the unit may be controlled on different phases.Complex lighting systems can be controlled via a 1-10 V interface. This interface has been incorporated into various HÜCO product; allowing simultaneous dimming of Compact fluorescent lamps, low voltage halo-gen and GLS.

Control Options• switch or control panel (electronic potentiometer) • IR-remote control• Light sensors for daylight lighting light controlBy combining the control modules listed with signal amplifiers, the number of electronic ballasts can be even extended.Reference list of the above mentioned modules see also page 116.

Adjustment rangeMinimum Luminous Flux: With 1V - signal at the control terminalsMaximum Luminous Flux: With 10V - signal at the control terminals

Comfortable LightingHÜCO dimmable ballasts enable a uniform and individual dimming of fluorescent lamps. HÜCO electronic ballasts work in the High Frequency range i.e. the gas discharge in the lamp is not interrupted. The lamp operates evenly without the electrode flickering and therefore emits a comfortable and relaxing light.

StartingThe ballasts can be started at any position of the dimmer. The lamp-protecting warm start guarantees reliable operation of the ballast even if the light has to be frequently switched on and off.Due to optimized management of the lamps excessive luminous flux (flash) can be avoided at switch on.

Voltage SupplyHÜCO dimmable ballasts are of a configuration which is suitable for all European mains voltages. They are also suitable for d.c. operation.

Interference SuppressionHÜCO products meet EMC guidelines.

Assembly and Operation• Switch off the mains • Wire according to specification• Ensure the correct lamp is fitted• Switch on the mains and carry out function test

Important Instructions• Installation and fitting should only be carried out by an approved

electrical contractor• Electronic ballasts and lights with inductive ballasts should not be

fitted in the same circuit• When three-phase systems are being used, ensure that the neutral

connection is fitted. Neutral interruption may result in overvoltage, thus damaging the ballast.

• The maximum permitted temperature should not be exceeded• Ensure there is adequate heat dissipation• Low ambient temperatures prolong the life of the ballast• In lighting systems with high frequency ballasts, it is recommended

to check the relevant manufacturer’s directions when selecting sensitive IR-controls

• Connection of the 1-10 V Interface by main rated cables (Interface not in accordance with SELV)

Recommended Cable Length and Cross SectionPlease choose the cable length according to the manufacturer indica-tions for cable capacities. We recommend that when using dimming double ballasts, the cables between the ballast and the lamp are the same length. If one lamp fails, both lamps should be replaced with lamps of the same type and manufacturer. The terminal blocks are sui-table for a conductor cross-section of maximum 1,5 mm2.

Earth ConnectionIt is to be noted that in order to ensure smooth operation, an earth connection should be fitted.

Dimmable electronic ballasts

Page 99: Lighting Electronics | 2007/08

www.hueco.com 99

Potentiometer

0-150-220 kΩ log

Wiring plan For larger configuration with additional signal amplifier. The number of electronic ballasts in the con-

figuration depends on type of signal amplifier.

Wiring plan for smaller configuration with manual potentiometer. The number of electronic ballasts in the con-

figuration depends on type of manual potentiometer.

Dimming each device with one potentiometer

Notice:The maximum quantity of dimmable electronic ballasts depends on: the capacity of the automatic fuses and on the capacity of

the relays.

Examples of circuits fordimmable ballasts

The DALI Standard has now been included in the ballast norm IEC 60929(E) and therefore facilitates the operation of ballasts from dif-ferent manufacturers at the same time in one control system.Initially DALI, was conceived as a ‚stand alone‘ solution but subse-quently it has been developed to be integrated in other building ma-nagement systems via the relevant interface. (EIB, LON etc.)

DALI ballasts are based on the tried and tested reliable technology of analog ballasts. This led to 100% compatibility and the adherence of the DALI standards acc. to IEC 60929(E). HÜCO DALI ballasts regular-ly undergo rigorous testing to ensure compatibility with requirements of the standard.

Important product characteristics of HÜCO DALI ballasts

• Microprocessor controlled• DALI interface with extended over-voltage immunity• Multipower technology (one electronic ballast suitable for different

lamps)• very compact shape• energy-saving (energy class EEI = A1)• flicker-free dimming from 100% to 3%• optimal lamp operation by HLC technology (HÜCO lamp control)• warm start of the lamp and operation acc. to EN 60929• Fulfills requirements of the new EN 61347 standard (previously

EN60928)• ENEC approved• 3 years warranty

DALI dimmable electronic ballasts

1...10V vs. DALI summary

1...10V DALI

Addressable individually

Group setting

Scene setting

Integrated system switching

Standard operation

Two-wire control

Isolated interface

Polarity independ interface

DALI is the abbreviation for „Digital Addressable Lighting Interface“ - The new standard for controllable lighting sy-stems

As a leading manufacturer of Electronic Ballasts and initial member of the AG DALI, HÜCO has contributed to developing a new standard for lighting control. This new standard provides more comfort and flexibility for lighting sy-stems and at the same time reduces system costs. The function of DALI ballasts is superior to the analog (1-10 V) controlled electronic ballasts. Despite the parallel wiring of the DALI electronic ballasts, they can be controlled singly (switching on and off directly via the control line without additional relay) and can be combined in banks and scenes. In addition, DALI ballasts offer the possibility of checking the operating condition of the lamp and the electronic ballast.

Page 100: Lighting Electronics | 2007/08

100

Altenburger 50.50.000 50.13.300 50.13.301 16.03.050 50.13.116 50.13.40050.50.001 16.03.060 50.13.145 50.13.41050.50.002 50.13.112 50.13.120 50.13.41150.50.010 50.13.113 50.13.121 50.13.50050.50.011 50.13.115 50.13.218 50.13.50150.50.012 50.13.142 50.13.320 50.13.51050.50.020 50.14.116 50.13.51150.50.021 50.13.52050.50.022 50.13.52150.50.030 50.13.53050.50.031 50.13.53150.50.03250.50.04050.50.04150.50.042

Busch-Jaeger 2112-U-101 6153 EB 6045 6550 U-1012112-101 6953 EB-101 6066-xxx 65502112 UJ-212 6020-xx2112 AJ 6021-xx2112 UJ-214-510 6010-252112 U-101-500

Feller 3310... * 3585-1.EUR.603330... * 3585-1.X.61

3564-1.EUR.613504.F. 60.9013504.F. 60.9023504.F. 60.903

Elko 397062226318

GIRA 0308 00 0359 000309 00 0360 00

0860 000865 00 1019 001137 00

JUNG 240-10 2092 REG X 240-10 EB PMU 360 WW240-31 2193 REG PMK 360 WW1240 STE FST 1240 REG FPM 360 WW

FST 1240 EBLegrand 775901 049511 003658

048501OSRAM DIM MCU P DIM SA DALI CON 1-0 LI DIM MULTI 2 DIM PICO

DALI CON 1-10 SO

DIM MULTI 3 DIM MICO

DIM MULTILS/PD MULTI 3 LS/PD MULTI 3 BLS/PD MULTI3 FL

PHILIPS LPS 100/00 IRC 2130 LRC 1010 LRL 1220 T5LPS 100/01 IRT 8030 LRC 1015 LRL 1220 T8

IRT 8050/00 LRC 1020 LRI 8133/10IRR 8124 LRC 1025IRR 8125 LRD 8010/10LRL 8101/10

SIEMENS 5TC84245TC8425

SIMON 27317 -32 -3575317 -39

Subject to technical modification

Reference list control equipment1-10 V controls

Manufacturer ElectronicPotentiometer

Signal Amplifier

AC/DC Converter IR - Module Control Unit Light/Move-

ment Sensor

Because of the variety of manufacturers this table only contains a small selection of products.

The exact product program with novelties and changes is available from the respective manufacturer. All data without guarantee.

Page 101: Lighting Electronics | 2007/08

www.hueco.com 101

Lifetimeof HÜCO ballasts

Increase life time of your fitting!

The life time of a fitting depends on the ambient temperature, the quality of the assigned components and the design. The maximum ambient temperature is governed by the application, so the technical designer can affect the quality of the fitting only by careful selection of components and a conscientious design. A critical and life time determining component is the electronic ballast.

Just as the life time of the fitting is determined by the ballast, so the life time of the ballast is determined by the assigned electrolytic capacitors. Due to the expecting life time of the Elko, the life time of the ECG will reach at least 50.000h with tc max, except for few exceptions. Whereby the indicated value refers to a maximum failure rate of 10%, operated with tc max.

For Multipower ballasts, the measurement was done with max. al-lowed lamp. That means, e.g. a Multipower fitting for 26-42W reach the maximum tc point temperature with a 42W lamp and with 26W lamp the tc point temperature is 10°C lower; then the life time for 26W will be doubled.

Which factors determine the life time of a EVG?

The life time of a ballast will be influenced by the electrical- mechani-cal and thermal- stress, for example high ambient temperature, volt-age peaks on mains and vibrations.

Electrical concept:

To resist against short- and long- term over voltage, we use more ro-bust components and an additional over voltage protection. The over voltages on mains (Surge and Burst) are relatively well known today and converted into a normative requirement. HUECO ballasts are fully tested in accordance with the standard and comply with the general requirements. Additionally HUECO ballasts except the Minipower product range are resistive against over voltage, 320V for 48h and 350V for 2h (e.g. neutral interruption).

Mechanical concept:

The insensitivity to mechanical loads such as vibrations and impacts is reached by the employment of SMD components. SMD’s do not have long connection legs and a lower weight than discrete components. SMD’s are soldered or stuck on the printed circuit board. Electronic transformers of HUECO have additionally double sided printed circuit boards. This guarantees a further mechanical security for specially loaded components like terminal blocks and output transformers.

Thermal concept:

Also in this point HÜCO went a clear, but not very easy way. As heat affects the life time negatively and heat is the result of power losses, the best way is to reduce the power losses on a minimum! Due to our experience of many years in the development of ballasts, we have succeeded in reducing the power losses by more than half. For example a 2x 26W TC-TEL ballast has power losses of only 3,5W at a power consumption of 53W. This corresponds to an efficiency of approx. 93%. Further, only quality components are used and the technical specification of the components is never exceeded. With HÜCO, particularly temperature-sensitive components (e.g. electro-lytic capacitors) are positioned in such a way that they have sufficient clearance from hot components such as coils.

How does HÜCO realize high life time and reliability?

Application example:

By a skilful luminairy construction it is possible to reduce the tc-point temperature and the Elko temperature in such a way which will disburse themselves this by the rise of the life span.

Is it possible as in the example to realise a temperature reduction of 10°C, the life span of the EVG will increase approximately to the double.

Page 102: Lighting Electronics | 2007/08

102

b) c)a)

Subject to technical modification

Connection - Primary Side Some Hüco transformers provide a loop in loop out facility on the pri-mary side of the transformer, eliminating complex wiring and at the same time reducing installation costs. Strain relief is also provided for both cables.

Connection - Secondary SideAll HÜCO transformers up to 150VA permit the connection of cables of up to 2,5 mm2 core cross-section and on a 210VA transformer up to a maximum of 4mm2. On 105VA types up to 3 lamps can be fitted directly to the 6-way terminal block.

Dimmer operationElectronic transformers can be operated with standard trailing edge phase-cut dimmers but when a dimmer is used, the power consump-tion of the dimmer will cause a reduction in the maximum achievable brightness. (ill. ET 1)

Interference SuppressionAll HÜCO transformers meet EMC guidelines.

Silent RunningWith HÜCO transformers are used only highly developed electronic con-struction units. Thus annoying humming of conventional transformers is void.

Light weight and compact shapeHÜCO transformers are characterised, depending upon equipment spe-cification, by a small weight from ca. 40g to ca. 270g and very compact dimensions.

No-Load ProtectionHÜCO transformers can be run without secondary load (missing or defective lamp) for an unlimited time.

Recommended Mains Voltage RangeThe maximum recommended Mains Voltage is rated voltage 230V +10%. For application in countries which do not use 230V, compatible transformers are available.

Harmonic Content of the Mains SupplyHÜCO products meet EMC guidelines.

ProtectionAll HÜCO independent converters are manufactured to Class II and are suitable for operating in Class II and III luminaires.

SoftstartHÜCO transformers have an electronic starting current restriction which enables a start without damaging the lamp (softstart). The lifespan of the lamp is therefore not reduced, particularly if it is frequently swit-ched on and off.

Part Load OperationIn contrast to conventional transformers, the output voltage varies very little when different loads are used. A minimum load is however required in order to make the circuit active. The transformer will not be damaged should the minimum load fall below that recommended, however, it can cause flickering of the lamp.

Overload and Short Circuit ProtectionHÜCO transformers have integrated overload and short-circuit protec-tion. Once the short-circuit or the overload has been removed, they will automatically switch on again. Exception: 210VA transformer. The electronic protection circuit on the 210VA transformer is reset after the mains supply has been interrupted for at least > 3 sec.

Overtemperature ProtectionDue to low power loss, HÜCO transformers have ample temperature reserves. Most types are automatically switched off by a reversible elec-tronic over-temperature sensor as soon as a specified temperature is exceeded. After a short cooling-down period the transformer will auto-matically switch on again.

Ambient TemperatureHÜCO transformers operate trouble-free in a temperature range of -20°C to 50°C or °60°C. Unhoused configurations can operate in higher ambient temperature ranges. Further information is available on request from our Customer Service Personnel.

Power LossThe minimal power loss of HÜCO transformers guarantees a sure and lasting operation, even under thermally unfavourable conditions.

Cable Strain ReliefFor those types of transformers designed for domestic and commer-cial installation there is an interchangeable cable strain relief available so that all standard cable types (flat, round, NYM) may be connected normally. (ill. ET 2)

Electronic Transformers

Abb. ET 2

Cable strain reliefa.) Without reversible insert b.) For round cablesc.) For flat cables

Abb. ET 1

Dimmer operation

Leading edge dimming Trailing edge dimming

Page 103: Lighting Electronics | 2007/08

Sales and Supply Conditions HÜCO electronic GmbHRange lighting electronics, Status 05/2002

Selection by lampI. General1. The scope of deliveries and/or services (hereinafter referred to as„Supplies“) shall be determined by the written declarations of both Parties. General terms and conditions of the Purchaser shall apply only if and when expressly accepted by the supplier or the provider of services (hereinafter referred to as „Supplier“) in writing.2. The Supplier herewith reserves any industrial property rights and/or copyrights pertaining to its cost estimates, drawings and other documents (hereinafter referred to as „Documents“). The Documents shall not be made accessible to third parties without the Supplier’s prior consent and shall, upon request, be returned without undue delay to the Supplier if the contract is not awarded to the Supplier. Sentences 1 and 2 shall apply mutatis mutandis to documents of the Purchaser; these may, however, be made accessible to third parties to whom the Supplier may rightfully transfer Supplies.3. The Purchaser shall have the non-exclusive right to use standard software, provided that it remains unchanged, is used within the agreed performance parameters, and on the agreed equipment. The Purchaser may make one back-up copy without express agreement.4. Partial Supplies shall be allowed, unless they are unreasonable to accept for the Purchaser.

II. Prices and terms of payment1. Prices shall be ex works and exclude packaging; value added tax shall be added at the then applicable rate.2. If the Supplier is also responsible for assembly or erection and unless otherwise agreed, the Purchaser shall pay the agreed remuneration and any incidental costs required, e. g. travel costs, costs for the transport of tools and equipment, and personal luggage as well as allowances.3. Payments shall be made free Supplier’s paying office.4. The Purchaser may set off only those claims that are undisputed or against which no legal recourse is possible.

III. Retention of title1. Items pertaining to the Supplies („Retained Goods“) shall remain the property of the Supplier until each and every claim the Supplier has against the Purchaser on account of the business connection has been fulfilled. If the combined value of the security interests of the Supplier exceeds the value of all secured claims by more than 20 %, the Supplier shall release a corresponding part of the security interest if so requested by the Purchaser.2. For the duration of the retention of title, the Purchaser may not pledge the Retaine Goods or use them as security, and resale shall be possible only for resellers in the ordinary course of their business and only on condition that the reseller receives payment from its customer or makes the transfer of property to the customer dependent upon the customer fulfilling its obligation to effect payment.3. The Purchaser shall inform the Supplier forthwith of any seizure or other act of inter- vention by third parties.4. Where the Purchaser fails to fulfil its duties, including failure to make payments due, the Supplier shall be entitled to cancel the contract and take back the Retained Goods in the case of continued failure following expiry of a reasonable time set by the Supplier; the statutory provisions that a time limit is not needed remain unaffected. The Purchaser shall be obliged to surrender the Retained Goods.

IV. Time for supplies; delay1. Times set for Supplies can only be observed if all Documents to be supplied by the Purchaser, necessary permits and releases, especially concerning plans, are received in time and if agreed terms of payment and other obligations of the Purchaser are fulfilled. Unless these conditions are fulfilled in time, times set shall be extended appropriately; this shall not apply where the Supplier is responsible for the delay.2. If non-observance of the times set is due to force majeure such as mobilization, war, rebellion or similar events, e. g. strike or lockout, such time shall be extended accordingly.3. If the Supplier is responsible for the delay (hereinafter referred to as „Delay“) and the Purchaser demonstrably suffered a loss therefrom, the Purchaser may claim a compensation as liquidated damages of 0.5 % for every completed week of Delay, but in no case more than a total of 5 % of the price of that part of the Supplies which because of the Delay could not be put to the intended use.4. Purchaser’s claims for damages due to delayed Supplies as well as claims for damages in lieu of performance exceeding the limits specified in No. 3 above shall be excluded in all cases of delayed Supplies even upon expiry of a time set to the Supplier to effect the Supplies. This shall not apply in cases of mandatory liability based on intent, gross negligence, or due to injury of life, body or health. Cancellation of the contract by the Purchaser based on statute shall be limited to cases where the Supplier is responsible for the delay. The above provisions do not imply a change in the burden of proof to the detriment of the Purchaser.5. At the Supplier’s request the Purchaser shall declare within a reasonable period of time whether the Purchaser cancels the contract due to the delayed Supplies or insists on the Supplies to be carried out.6. If dispatch or shipment is delayed at the Purchaser’s request by more than one month after notice of the readiness for dispatch was given, the Purchaser may be charged, for every month commenced, storage costs of 0.5 % of the price of the items of the Supplies, but in no case more than a total of 5 %. The parties to the contract may prove that higher or, as the case may be, lower storage costs have been incurred.

V. Transfer of risk1. Even where delivery has been agreed freight free, the risk shall pass to the Purchaser as follows: a) if the Supplies do not include assembly or erection, at the time when the Supplies are shipped or picked up by the carrier. Upon request of the Purchaser, the Supplier shall insure the Supplies against the usual risks of transport at the expense of the Purchaser; b) if the Supplies include assembly or erection, at the day of taking over in the own works or, if so agreed, after a fault-free trial run.2. The risk shall pass to the Purchaser if dispatch, shipping, the start or performance of assembly or erection, the taking over in the own works or the trial run is delayed for reasons for which the Purchaser is responsible or if the Purchaser has otherwise failed to accept the Supplies.

VI. Assembly and erectionUnless otherwise agreed in writing, assembly/erection shall be subject to the following provisions:1. The Purchaser shall provide at its own expense and in good time: a) all earth and construction work and other ancillary work outside the scope of the Supplier, including the necessary skilled and unskilled labour, construction materials and tools, b) the equipment and materials necessary for assembly and commissioning such as scaffolds, lifting equipment and other devices as well as fuels and lubricants, c) energy and water at the point of use including connections, heating and lighting, d) suitable dry and lockable rooms of sufficient size adjacent to the site for the storage of machine parts, apparatus, materials, tools, etc. and adequate working and recreation rooms for the erection personnel, including sanitary facilities as are appropriate in the specific circumstances. Furthermore, the Purchaser shall take all measures it would take for the protection of its own possessions to protect the

possessions of the Supplier and of the erection personnel at the site, e) protective clothing and protective devices needed due to particular conditions prevailing on the specific site.2. Before the erection work starts, the Purchaser shall make available of its own accord any information required concerning the location of concealed electric power, gas and water lines or of similar installations as well as the necessary structural data.3. Prior to assembly or erection, the materials and equipment necessary for the work to start must be available on the site of assembly/erection and any preparatory work must have advanced to such a degree that assembly/erection can be started as agreed and carried out without interruption. Access roads and the assembly/erection site itself must be level and clear.4. If assembly, erection or commissioning is delayed due to circumstances for which the Supplier is not responsible, the Purchaser shall bear the reasonable costs incurred for idle times and any additional travelling of the Supplier or the erection personnel.5. The Purchaser shall attest to the hours worked by the erection personnel towards the Supplier at weekly intervals and the Purchaser shall immediately confirm in writing if assembly, erection or commissioning has been completed.6. If, after completion, the Supplier demands acceptance of the Supplies, the Purchaser shall comply therewith within a period of two weeks. In default thereof, acceptance is deemed to have taken place. Acceptance is also deemed to have been effected if the Supplies are put to use, after completion of an agreed test phase, if any.

VII. Receiving of suppliesThe Purchaser shall not refuse to receive Supplies due to minor defects.

VIII. Defects as to qualityThe Supplier shall be liable for defects as to quality („Sachmängel“, hereinafter referred to as „Defects“,) as follows:1. All parts or services where a Defect becomes apparent within the limitation period shall, at the discretion of the Supplier, be repaired, replaced or provided again free of charge irrespective of the hours of operation elapsed, provided that the reason for the Defect had already existed at the time when the risk passed.2. a) Claims based on Defects are subject to a limitation period of 12 months. Thi provision shall not apply where longer periods are prescribed by law according to Sec. 438 para. 1 No. 2 (buildings and things used for a building), Sec. 479 para. 1 (right of recourse), and Sec. 634a para. 1 No. 2 (defects of a building) German Civil Code („BGB“), as well as in cases of injury of life, body or health, or where the Supplier intentionally or grossly negligently fails to fulfil its obligation or fraudulently conceals a Defect. The legal provisions regarding suspension of expiration („Ablaufhemmung“), suspension („Hemmung“) and recommencement of limitation periods remain unaffected. b) Extension of Period of Limitation Irrespective of any other contractually or legally stipulated warranty claims, the supplier shall provide a warranty to the customer in deviation from § 438 Section 1 No. 3. of the BGB (German Civil Code) for material defects beyond the two-year limitation period until expiry of the 36-month period from delivery for the freedom of the object from material defects. The supplier shall be obligated, within the extended period of limitation, to rectify the defects in, re-supply or renew all parts or perfomances that exhibit deficiencies within the extended period of limitation. This shall be subject to the provisions that the cause of the deficiency was already present at the time of risk transfer and that the material defect was caused through the fault of the supplier. Article VIII. Nos. 3., 4. and 7. shall apply accordingly. Rectification,re- supply or renewal shall be free of charge and the decision as to which of these measures or which combination of these measures is taken shall be at the discretion of the sup-plier. Further claims of the customer, in particular claims for damages or losses, rights of withdrawal or rights to price reduction or claims under a right of recourse of the customer are excluded within the period of the extended period of limitation. Claims of the customer on account of the required expenses for the purposes of subsequent performance, in particular transportation, travel and labour costs and costs of materials are also excluded.3. The Purchaser shall notify Defects to the Supplier in writing and without undue delay.4. In the case of notification of a Defect, the Purchaser may withhold payments to a rea-sonable extent taking into account the Defect occurred. The Purchaser, however, may withhold payments only if the subject-matter of the notification of the Defect occurred is justified beyond doubt. Unjustified notifications of Defect shall entitle the Supplier to have its expenses reimbursed by the Purchaser.5. The Supplier shall first be given the opportunity to supplement its performance („Nacherfüllung“) within a reasonable period of time.6. If supplementary performance is unsuccessful, the Purchaser shall be entitled to cancel the contract or reduce the remuneration, irrespective of any claims for damages it may have according to Art. XI.7. There shall be no claims based on Defect in cases of insignificant deviations from the agreed quality, of only minor impairment of usefulness, of natural wear and tear or Damage arising after the transfer of risk from faulty or negligent handling, excessive strain, unsuitable equipment, defective workmanship, inappropriate foundation soil or from particular external influences not assumed under the contract, or from non-reproducible software errors. Claims based on defects attributable to improper modifications or repair work carried out by the Purchaser or third parties and the consequences thereof shall be likewise excluded.8. The Purchaser shall have no claim with respect to expenses incurred in the course of supplementary performance, including costs of travel and transport, labour, and material, to the extent that expenses are increased because the subject-matter of the Supplies was subsequently brought to another location than the Purchaser’s branch office, unless doing so complies with the intended use of the Supplies.9. The Purchaser’s right of recourse against the Supplier pursuant to Sec. 478 BGB is limited to cases where the Purchaser has not concluded an agreement with its customers exceeding the scope of the statutory provisions governing claims based on Defects. Moreover, No. 8 above shall apply mutatis mutandis to the scope of the right of recourse the Purchaser has against the Supplier pursuant to Sec. 478 para. 2 BGB.10. Furthermore, the provisions of Art. XI (Other Claims for Damages) shall apply in respect of claims of damages. Any other claims of the Purchaser against the Supplier or its agents or any such claims exceeding the claims provided for in this Art. VIII, based on a Defect, shall be excluded.

IX. Industrial property rights and copyright; defects in title1. Unless otherwise agreed, the Supplier shall provide the Supplies free from third parties’ industrial property rights and copyrights (hereinafter referred to as „IPR“) with respect to the country of the place of destination. If a third party asserts a justified claim against the Purchaser based on an infringement of an IPR with respect to the Supplies made by the Supplier and then used in conformity with the contract, the Supplier shall be liable to the Purchaser within the time period stipulated in Art. VIII No. 2 as follows: a) The Supplier shall choose whether to acquire, at its own expense, the right to use the IPR with respect to the Supplies concerned or whether to modify the Supplies such that they no longer infringe the IPR or replace them. If this would be unreasonable to demand from the Supplier, the Purchaser may cancel the contract or reduce the remuneration pursuant to the appli-cable statutory provisions. b) The Supplier’s liability to pay damages shall be governed by Art. XI. c) The above obligations of the Supplier shall only apply if the Purchaser(i) immediately notifies the Supplier of any such claim asserted by the third party in

writing, (ii) does not concede the existence of an infringement and (iii) leaves any protective measures and settlement negotiations to the discretion of the Supplier. If the Purchaser stops using the Supplies in order to reduce the damage or for other good reason, it shall be obliged to pointout to the third party that no acknowledge ment of the alleged infringement may be inferred from the fact that the use has been discontinued.2. Claims of the Purchaser shall be excluded if it is itself responsible for the infringement of an IPR.3. Claims of the Purchaser shall also be excluded if the infringement of the IPR is caused by specifications made by the Purchaser, to a type of use not foreseeable by the Supplier or to the Supplies being modified by the Purchaser or being used together with products not provided by the Supplier.4. In addition, with respect to claims by the Purchaser pursuant to No. 1 a) above, Art. VIII Nos. 4, 5, and 9 shall apply mutatis mutandis in the event of an infringement of an IPR.5. Where other defects in title occur, Art. VIII shall apply mutatis mutandis.6. Any other claims of the Purchaser against the Supplier or its agents or any such claims exceeding the claims provided for in this Art. IX, based on a defect in title, shall be excluded.

X. Impossibility of performance; adaption of contract1. To the extent that Supplies are impossible to be carried out, the Purchaser shall be entitled to claim damages, unless the Supplier is not responsible for the impossibility. The Purchaser’s claim for damages shall, however, be limited to an amount of 10 % of the value of the part of the Supplies which, owing to the impossibility, cannot be put to the intended use. This limitation shall not apply in the case of mandatory liability based on intent, gross negligence or injury of life, body or health; this does not imply a change in the burden of proof to the detriment of the Purchaser. The right of the Purchaser to cancel the contract shall remain unaffected.2. Where unforeseeable events within the meaning of Art. IV No. 2 substantially change the economic importance or the contents of the Supplies or considerably affect the Supplier’s business, the contract shall be adapted taking into account the principles of reasonableness and good faith. Where doing so is economically unreasonable, the Supplier shall have the right to cancel the contract. If the Supplier intends to exercise its right to cancel the contract, it shall notify the Purchaser thereof without undue delay after having realised the repercussions of the event; this shall also apply even wherean extension of the delivery period had previously been agreed with the Purchaser.

XI. Other claimes for damages1. Any claims for damages and reimbursement of expenses the Purchaser may have (hereinafter referred to as „Claims for Damages“), based on whatever legal reason, including infringement of duties arising in connection with the contract or tort, shall be excluded.2. The above shall not apply in the case of mandatory liability, e. g. under the German Product Liability Act („Produkthaftungsgesetz“), in the case of intent, gross negligence, injury of life, body or health, or breach of a condition which goes to the root of the contract („wesentliche Vertragspflichten“). However, Claims for Damages arising from a breach of a condition which goes to the root of the contract shall be limited to the foreseeable damage which is intrinsic to the contract, unless caused by intent or gross negligence or based on liability for injury of life, body or health. The above provision does not imply a change in the burden of proof to the detriment of the Purchaser.3. To the extent that the Purchaser has a valid Claim for Damages according to this Art. XI, it shall be time-barred upon expiration of the limitation period applicable to Defects pursuant to Art. VIII No. 2. In the case of claims for damages under the German Product Liability Act, the statutory provisions governing limitation periods shall apply.

XII. Venue and applicable law1. If the Purchaser is a businessperson, sole venue for all disputes arising directly or indirectly out of the contract shall be the Supplier’s place of business. However, the Supplier may also bring an action at the Purchaser’s place of business.2. Legal relations existing in connection with this contract shall be governed by German substantive law, to the exclusion of the United Nations Convention on Contracts for the International Sale of Goods (CISG).

XIII. Severability clauseThe legal invalidity of one or more provisions of this contract shall in no way affect the validity of the remaining provisions. This shall not apply if it would be unreasonable for one of the parties to continue the contract.

XIV. Catalogue informationOnly the catalogue valid at the time of the conclusion of the contract shall apply. All pre-vious catalogues and the information therein shall be rendered invalid by the catalogue applicable at the time of concluding the contract.All technical values of the supplier‘s product stated in the catalogue are average values determined from electronically-held operational data.

HÜCO electronic GmbH

Electronic Ballasts for TC-SEL 7

Electronic Ballasts for TC-DEL/TEL 8

Electronic Ballasts for TC-L/F 9

Electronic Ballasts for TC-DD 10

Electronic Ballasts for T5c 11

Electronic Ballasts for T5 12

Electronic Ballasts for T8 13

Electronic Ballasts for HID 83

List of article numbers 14

Product by type

Compact Electronic Ballasts,not dimmable

16 - 3882

Compact Electronic Ballasts,1...10V dimmable

39 - 49

Compact Electronic Ballasts,DALI dimmable

49 - 55

T5 Electronic Ballasts,not dimmable

56 - 63

T5 Electronic Ballasts,1...10V dimmable

64 - 71

T8 Electronic Ballasts,not dimmable

72 - 75

T8 Electronic Ballasts,1...10V dimmable

76 - 81

HID Electronic Ballasts 83 - 85

Electronic Transformers 86 - 89

Trailing Edge Phase-Cut Dimmer 90

Accessories 91 - 92

Page 104: Lighting Electronics | 2007/08

Distributors

Germany (Headquarters)

HÜCO electronic GmbHVon dem Bussche-Münch-Str. 1232339 EspelkampDeutschlandPhone: 0049 5772 567 700Fax: 0049 5772 567 940Email: [email protected]

Northern Ireland

HÜCO Lightronic N.I. Ltd.3 Aghanloo Ind. Estate, Aghanloo RoadLimavady Co. LondonderryNorthern Ireland, BT49 OHEPhone: 0044 28 777 60 004Fax: 0044 28 777 60 011Email: [email protected]

IndiaHueco Lightronic (India) Pvt. Ltd.Survey No 19, Yewlewadi

Kondhwa, Pune - 411 048

India

Phone: 0091 20 26 93 3622

Fax: 0091 20 26 93 4314

Email: [email protected]

Italy

HÜCO electronic GmbHSales Office ItalyVia Cavriana, 320134 MilanoPhone 0039 02 7391 274Fax 0039 02 7391 401 Email: [email protected]

U.K.

HÜCO Lightronic N.I. Ltd.Sales Office UKUnit 6, The Gateway, 2A Rathmore RoadLondon SE7 7QWPhone 0044 28 777 60004Fax 0044 28 777 60 011Email: [email protected]

China

HÜCO Lightronic N.I. Ltd.Sales Office ChinaRoom 722, No. 40, Dongzhong St,Donghcheng District, 100027 BeijingPhone 0086 10 51 692605Fax 0086 10 51 692606Email: [email protected]

© by HÜCO electronic GmbH

Due to a policy of continuous improvement, HÜCO electronic GmbH reserves the right to amend the specifications and details in this catalogue without prior notice

This catalogue replaces all previous material issued by HÜCO

HÜCO Lightronic N.I. Ltd., Limavady, Northern Ireland

HÜCO electronic GmbH, Espelkamp, Germany

Hueco electronic (India) Pvt. Ltd., Pune, India

AustriaVBE Vertrieb BeleuchtungPragerstraße 1421210 WIENPhone: 0043 1 2782424Fax: 0043 1 2782485Email: [email protected]

BelgiumTertium Sprl11, Avenue des lilas1640 Rhode Saint GenesePhone: 0032 2 3614858Fax: 0032 23 583023Email: [email protected]

DanmarkVanpée & Westerberg A/STransformervej 212730 HerlevPhone: 0045 44 859000Fax: 0045 44 859087Email: [email protected]

FranceDitronic S. A. R. L.13, rue des hirondelles67720 WeyersheimPhone: 0033 388 629 027Fax: 0033 388 681 822Email: [email protected]

GreeceTransHellas20-22, Kyparissias streetAgioi Anargir, 13562 AthenPhone: 0030 210 4523740Fax: 0030 210 4523010Email: j.agistriotis@trans- hellas.com

TurkeySPOT ELEKTRIK Ltd.35. CAD., No. 10/234076 USKUDARPhone: 0090 216 324 33 77Fax: 0090 216 472 87 68Email: [email protected]

SwedenVanpée & Co. ABGlanshammarsgatan 1612470 BandhagenPhone: 0046 855 621130Fax: 0046 864 78065Email: [email protected]

South KoreaJeung Han Trading Company135-21, Chegi-DongROK Tongdaemun-Ku SeoulPhone: 0082 29270531Fax: 0082 29270536Email: jeunghankr@yahoo. co.kr

NorwayVanpée Norge ASVestvollveien 6D2020 SkedsmokkorsetPhone: 0047 648 38280Fax: 0047 648 38281Email: fi [email protected]

IsraelElectrosen Ltd.23, Hapalmach Street51246 BNEI-BRAKPhone: 00972 3 6184131Fax: 00972 3 61896805Email: [email protected]

AustraliaLighting Australia Pty. Ltd.Unit R2, Regents Park Estate391 Park RoadRegents Park NSW 2143Phone: 0061 02 9738 9444Fax: 0061 02 9738 9499Email: components@ lightingaustralia.com.au

MalaysiaUNI-TEC Engineering PTE Ltd3, Lorong Bakar Batu# 07-01 Brightway BuildingSingapore 348741Phone: 0065 6 7459422Fax: 0065 6 7453930Email: enquiries@unitec. com.sg

SwitzerlandSir Heian Beleuchtungstechnik AGAlte Steinhauserstraße 296330 ChamPhone: 0041 41 7485010Fax: 0041 41 7485015Email: [email protected]

NetherlandsRegoort B. V. TechnischeHandelsmaatschappijBergstraat 8 – 123035 TD-ROTTERDAMPhone: 0031 10 4658155Fax: 0031 10 4672934Email: [email protected]

SpainIndustrial Eléctra Cassanense S. A.Crta/ de Girona a Sant Feliu Km, 1117244 Cassa de la Selva Phone: 0034 972 46 01 25Fax: 0034 972 46 19 79Email: [email protected]