www.lgeaircon.com SOLO Optimized solution for Light commercial applications. Distributed by LG Electronics AE Company, Commercial Air Conditioning 20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea. Phone : +82-2-3777-7731 Fax : +82-2-3777-3099 www.lg.com www.lgeaircon.com Copyright © 2011 LG Electronics. All rights reserved.

Transcript of LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model...

Page 1: LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model ARUN80L M3ARUN100L ARUN120L Capacity Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5

www.lgeaircon.com

Solo

Optimized solution for Light commercial applications.

Distributed by

LG ElectronicsAE Company, Commercial Air Conditioning20 Yeouido-dong, Yeongdeungpo-gu, Yeouido P.O.Box 335 Seoul, 150-721, Korea.Phone : +82-2-3777-7731 Fax : +82-2-3777-3099www.lg.com www.lgeaircon.com

Copyright © 2011 LG Electronics. All rights reserved.

Page 2: LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model ARUN80L M3ARUN100L ARUN120L Capacity Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5

Enjoy Clean, Quiet, and Comfortable Air Conditioning with LGMulti V III solo is ideal for shops, small offices, restaurants and hotels, and also for multiple owners buldings, symmetrical buldings and mid-large capacity buldings with small rooms (to respect EN378)

Eco-Design, Energy Efficient Reduce CO2 Emissions

Page 3: LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model ARUN80L M3ARUN100L ARUN120L Capacity Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5

SOLO

Multi V III solo provides the office workers to work under comfortable and silent environment, with 4way cassetts or concealed ducts. It can also use a separate outdoor unit with different indoor units, for spaces such as conference rooms and kitchens, with 130% compatibility.

Multi V III solo offers optimized solution for light commercial applications, such as offices, shops, restaurants, and residential buildings.

Depending on space utilizations, various indoor units can be applied with Multi V III solo. Therefore, customers are allowed to do shopping under perfect environment and conditions.

Concealed ducts, provided by Multi V III solo, are great match with luxurious interior of restaurants. Customers can enjoy their meal with comfort and satisfaction

offices

A building with multiple owners symmetrical building

shop

Restaurants

lG Air Conditioners 2011

Application Example

Different owners may use separate outdoor units for their own operation costs and management.

It is more efficient to use separate outdoor units, rather than a combination of outdoor units to save installation cost.

Regulation EN 378To meet regulation EN378, the amount of refrigerant leakage should satisfy the following equation for human safety.

Total amount of refrigerant in the system

Volume of the room at which Indoor unit of the least capacity is installed <0.44

Project: VRF, capacity of 24HP (12HP+12HP)

Total quantity of R410A in the system = 24.8kg (oDU 12.8kg + IDU&pipes ~12kg)

Two separate 12HP outdoor units providing different solutions with two circuits.

20m2 20m2

24HP12HP 12HP

A combination of two 12HP outdoor units providing a solution with one circuit.

In the project, the smallest room/office is 20m², so 50m3.

The concentration in this room is: 24.8kg/50m3 = 0.50kg/m3

EN 378 not respected

Add ventilation system in all small rooms (20m²)(air flow 40m3/h each), with leakage detectors

Total quantity of R410A in one system (12HP) = 12.4 kg (oDU 6.4kg + IDU&pipes ~6kg)

The concentration in this room is: 12.4kg/50m3 = 0.25kg/m3

EN 378 respected

EN 378 respected

Conventional Conventional

Conventional

MUlTI V lll solo

MUlTI V lll solo

MUlTI V lll solo

Page 4: LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model ARUN80L M3ARUN100L ARUN120L Capacity Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5

lG Air Conditioners 2011

High cooling and heating COPTechnical innovation for high COPMulti V simple has high effi-ciency parts, advanced interv-er control technology and optimal cycle control technol-ogy, which the system’s uni-fied performance has been improved. Based on these advanced technologies, the product provides customers value through high efficiency and energy saving.

※Coefficient of Performance (CoP) =

Therefore, higher CoP of a product makes its cooling and heating capability higher and energy consumption lower

Cooling / Heating Energy consumption

ConventionalMulti V III Simple5

1

2

6 7

3

4

18%UP

3%UP

4.04

3.41

4.12

4.23

lG BlDC inverter compressor

sine wave inverter control

Cyclone sub-cooling circuit

Newly designed propeller fan

lG BlDC Inverter fan Motor

Uniform distributor for the heat exchanger

Improved the energy efficiency by 11%, compared to the AC inverter compressor, using the high efficiency lG BlDC inverter compressor.

Improved the efficiency of the compressor motor by using the sine wave DC inverter control technology.

Improved the cooling capability by using a cyclone sub-cooling circuit.

Achieved optimal heat exchange by using high air volume and low noise fan.

Improved efficiency by using high efficiency BlDC inverter motor, compared to the AC motor.

Improved heat exchange performance and efficiency by reducing greatly the heat exchanger’s temperature deviation from 5ºC to 1ºC, applying an optimal distributor design to the heat exchanger.

5

6

1

2

3

4

5 1

CompSC EEV

EEVEvaporator

Condenser

Sub Cooling circuit

H

Liquid

Capacity

P

Sub Cooling Circuit

Liquid + Gas

32

4 3

4 3

5 1

2

4 5555

EEVE

44

CoolingCycle

ComppSC EEV

CoolingCoolingCycleCycle

5 1

CompSC EEV

EEVEvaporator

Condenser

Sub Cooling circuit

H

Liquid

Capacity

P

Sub Cooling Circuit

Liquid + Gas

32

4 3

4 3

5 1

2

4 5555

EEVE

44

CoolingCycle

ComppSC EEV

CoolingCoolingCycleCycle

OLD

NEW

OLD

NEW

OLD

NEW

OLD

NEW

Provides low noise levels through pod-shaped design

Minimizes vortex resistance with a curved shape

Provides high air volume and high static pressure with the changed shape

Flexible indoor unit combinationsince up to 20 indoor units can be connected with 13 types of 71 different indoor models selections, a variety of designs tailored for individual construction usage can be made. Up to 130% efficiency can be achieved with different combinations.

Connectable Indoorunit Capacity

Up to Max 130%Various Indoor units

13 types, 71 modelsConnectable Indoor

unit Number

Up to 20

��A combination with maximum 130% efficiency can be achieved only if the changes of the heating and cooling load and the product oper ation rate by time are considered

Extended piping length and elevationInverter control technology and sub-cooling control circuit technology provide best solution for mid-size buildings

Total piping length Max 150m(170m**)

Longest piping length Max 100m

Level difference between ODU*~IDU*

Max 50m

ODU* : Outdoor unitIDU* : Indoor unit** : Equivalent

Longest piping length after 1st branch

Max 40m

Level differentbetween IDU*~IDU*

Max 15m

Automatic detection for incorrect connectionsMulti V III solo automatically checks that connections of piping lines and communication lines with its FDD(Fault Detection & Diagnosis) function providing notification on any errors.

Communicationlines

Incorrect piping line connection(liquid line + gas line)

Incorrect communication line connection

Auto leakage detection

Refrigerant recovery and reuse

No refrigerant leakage design and production

The product monitors the operation status data in real time and decides the appropriate amount of refrigerant and displays it. It also automatically notifies the user of any small refrigerant leakage.

When performing maintenance on the product, the refrigerant is not discharged to the air, but saved by collecting it inside an outdoor unit, a refrigerant pipe, or an indoor unit. This increas-es environmental protection and reduces costs.

Brazing

냉매누설방지용접 가공

Refrigerant recovery

The product is especially designed and produced with brazing to prevent from refrigerant leakage

Wide louver fins for the heat exchangerImproved efficiency by using wide louver fins with an increased heating area.

7

Intelligent simple test runAutomatic test run mode immediately checks and noti-fies various installation and operation problems, reducing installation engineers’ efforts and time.

Compared to the conventional product, It can reduce test run time by more than 60% provides safe, reliable and convenient test run with various data backup functions.

setting

Reporting

MUlTI V lll solo

Real-time fault prediction functionThis product allows you to check the current status for the sensors and the EEV, which are the major compo-nents for system control, through auto test run. And alerts you of which one of them has a problem, you can take action quickly even if a problem occurs within the normal operation range.

에러

고장예측

에러 에러정상 운전 영역

고장예측

Error

Normal operation range

sensor

EEV

Automatic refrigerant charging functionThe FDD algorithm calculates and automatically charges the correct amount of refrigerant without using an elec-tronic scale. Therefore, installation reliability is increased and product performance is guaranteed.

Embedded with the FDD algorithm

Indicated by the LED indicatorwhen fully charged

test runReporting

test runReporting

setting

Connecting lGMV

Connecting PC

Test run

Reporting

Conventional

test runReporting

test runReporting

test runReporting

test runReporting

test runReporting

3hr / Unit1hr / Unit

Automatic test run results

Automatic reporting

submitted to the customer

Data back up

Use of a laptop or PDA

Save 60

% test run tim

e

SOLO

Page 5: LG Electronics AE Company, Commercial Air … Air Conditioners 2011 specifications HP 8 10 12 Model ARUN80L M3ARUN100L ARUN120L Capacity Cooling kW 22.4 28.0 33.6 Heating kW 25.2 31.5

lG Air Conditioners 2011

specifications

HP 8 10 12

Model ARUN80LM3 ARUN100LM3 ARUN120LM3Capacity Cooling kW 22.4 28.0 33.6

Heating kW 25.2 31.5 37.8

Power Cooling kW 5.55 7.20 9.30

Input Heating kW 5.96 7.60 9.34

COP Cooling 4.04 3.89 3.61

Heating 4.23 4.14 4.05

Power Supply Ø, V, Hz 3, 380~415, 50

Dimensions(WxHxD) mm 920×1,680×760

Weight kg 175×1 218×1

Color Warm Gray, Morning Gray

Noise level dBA±3 57 58

Fan Type Propeller fan

Air flow rate [CMM] 180 190

Compressor Type DC scroll

Number of compressors 1 2

Heat Exchanger Gold fin

Refrigerant Type R410A

Charge kg 5.0 5.5

Control EEV

Oil Type FVC68D(PVE)

Charge cc 2,825 3,975

Piping Liquid Pipes mm(inch) Ø9.52(3/8) Ø12.7(1/2)

Connections Gas Pipes mm(inch) Ø19.05(3/4) Ø22.2(7/8) Ø28.58(1 1/8)

Operating rangeCool ing °CDB -5 ~ 43

Heating °CWB -20 ~ 15,5

Number of outdoor unit 1

Number of maximum connectable indoor units * 13 16 20

Ratio of the connectable indoor units 50~130%

Longest piping length / Level difference ** 50~130%

• A combination operation over 100% cause to reduce each indoor unit capacity

CAUTION

1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C (80.6°F) DB /19°C (66.2°F) WB - outdoor Temperature 35°C (95°F) DB /24°C (75.2°F) WB Piping length - Interconnecting Piping length 7.5m - level Difference of Zero.

2. Capacities are net capacities3. EEV : Electronic Expansion Valve4. Wiring cable size must compaly with the applicable local and national code.5. Due to our policy of innovation some specifications may be changed without notification.

Heating: - Indoor Temperature 20°C (68°F) DB / 15°C(59°F) WB - outdoor Temperature 7°C (44.6°F) DB / 6°C (42.8°F) WB

Note :

* A ratio of the connectable indoor units with the outdoor : Within 50% ~ 130%

Add this note: All remote controllers and central controllers of Multi V range are available with MVS system.

Conversion Formula

RT = kW x 0.284kcal/h = kW x860Btu/h = kW x 3412CFM = m3/min x 35.3

SOLO

Indoor line Up

kW

Btu / h

2 way Cassette

1 way Cassette

Low Static

Built-in

High Static

With Case

Without Case

Ceiling Cassette

Ceiling Concealed Duct

FreshAir Intake Unit

Floor standing

Ceiling & Floor

Ceiling suspended

(840*840)4way Cassette

(570*570)4way Cassette

Mirror

series

Wall mounted

Console

5k 7k 9k 12k 15k 18k 24k 28k 36k 42k 48k 76k 96k

1.5 2.2 2.8 3.6 4.5 5.6 7.1 8.2 10.6 12.3 14.1 22.428.0