LG 2011 Accessories Catalog

download LG 2011 Accessories Catalog

of 32

Transcript of LG 2011 Accessories Catalog

  • 8/7/2019 LG 2011 Accessories Catalog

    1/32

    www.

    lgeaircon.

    com

    2008 LG Air Conditioner

    Accessories

    2008 LG Air Conditioner

    Accessories

    Air Conditioner

    20 Yeouido-dong, Yeongdeungpo-gu,

    Yeouido P.O.Box 335 Seoul, 150-721, Korea.

    Phone : +82-2-3777-7958 Fax : +82-2-3777-5139

    www.lgeaircon.com

    Distributed by

    GL-AC081

  • 8/7/2019 LG 2011 Accessories Catalog

    2/32

    C o n t e n t s

    Brief History

    V-net 04Remote Controller 06

    Central Contr oller 12

    Electronic Accessory 28

    Mechanical Accessory 40Piping Accessory 52

    Establishment1947 Establishment of the LG Group1958 Establishment of LG Electronics Inc.

    1962 Establishment of Digital Appliance Company

    Growth1968 Manufactured Koreas first air conditioners

    1985 Introduced Koreas first Inverter air conditioners

    1986 Exported Koreas first window type air conditioners

    Expansion1995 Establishment of LGETA in china

    1997 Establishment of LGEIL in India

    1999 Establishment of LGEAT in Turkey

    1999 Establishment of LGEMH in Vietnam

    2001 Establishment of LGEAZ in Brazil

    2002 Establishment of LGETH in Thailand

    2002 Establishment of LGEIN in Indonesia

    2004 Turnover of US$1.4 Billion dollars

    Global Air Conditioning Academies

    LG Air Conditioner_Accessories

    Changwon in Korea

    Spain Italy Dubai China Saudi Arabia

    Pyeongtaek in Korea Thailand

    Mexico Panama Indonesia Iran Turkey Vietnam

    England France Australia Moscow Singapore

  • 8/7/2019 LG 2011 Accessories Catalog

    3/32

    Line up

    RemoteController

    CentralController

    ElectronicAccessory

    Wireless RemoteController

    Simple

    PQWRH(C)DF0

    PQWRH(C)SF0

    PPWRH(C)SF0

    PQRCUCA0 (Simple)

    PQRCFCS0 (Simple for Hotel)PQRNC0 (Simple for operation with Radiator)

    PQCSB101S0

    PQCSB101S0+PQCSC101S0

    PQCSB101S0+PQCSC101S0( Func ti onCo nt ro ller ) ( Sc he du le r)

    PQCSW320AE

    PQCSW502A2

    PQCSS513A0

    PQCPA11A0E (With IO),

    PQCPB11A0E (Without IO)

    PQCSS520A0E (AC Manager)

    PQNFB16A1 (LONWORKS)

    PQNFB17B0 (BACnet)

    PI 485, CNU, DO Kit, Dry Contact, Cool/Heat Selector,

    Zone Controller, Electronic Thermostat, CTI, Low Ambient Kit,

    Remote Temperature Sensor, PDI, Telecom Shelter Controller

    PQRCUSA0

    PCRCUSZ0

    PZRCUSB0

    PDRCUSZ0

    PQRCUDS0 (White)

    PQRCUDSOB (Blue)

    PQRCUDSOS (Silver)

    Wired RemoteController

    Simple CentralController

    AC Smart

    Deluxe CentralController

    PC Based Central

    Controller

    ACP &AC Manager

    BMS

    Standard

    Deluxe

    V-NET

    04

    0 5

    V-net, LG Network Solution provide comfortable environment and energy savingby optimum control of Air -conditioning system.

  • 8/7/2019 LG 2011 Accessories Catalog

    4/32

    Remote Controller Line up

    Remote controllerOur air conditioning system can be controlled by various types of

    remote controllers providing general control to unique function.

    Rem

    ote

    Co

    ntroller

    06

    07

    Standard WiredRemote Controller

    Deluxe Wired Remote

    Controller

    Simple Wired Remote

    Controller

    Wireless RemoteController

    08

    09

    10

    11

    Function PQRCFCS0 PQRCUCA0 PQRCUSA0 PQRCUDS0(B,S) PQWRHDF0

    On / Off

    Fan speed

    Temperature setting

    Mode change

    Auto swing

    Vane control

    E.S.P function

    Reservation

    Timer Function

    Electric failure compensation

    Child lock

  • 8/7/2019 LG 2011 Accessories Catalog

    5/32

    FEATURES

    Operating modeOn / Off LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMain/Sub setting of indoor units (For override function)T setting (For Auto Changeover)2 Controllers to 1 indoor unitsGroup and central control at the same time

    Applicable for only MULTI V II series (MULTI V PLUS II, MULTI V SYNC II, MULTI V SPACE II , MULTI V MINI & 08 new indoor units) Refer to each model PDB for applicable models.

    On_Off / Fan speed / Mode / Temp.

    Weekly / Simple

    Max 2 hours

    MULTI V SYNC II

    PQRCUSA0

    Standard Wired Remote Controller08 09REMOTE CONTROLLER

    For Air conditioner

    PQRCUSA0 / PCRCUSZ0PDRCUSZ0 / PZRCUSB0

    The standard remote controller can be used by various means.

    It can control an indoor units or group of indoor units.

    FEATURES

    For

    PQRCUSA0

    Operating modeOn / Off LEDRoom temp.Fan / Plasma / HeaterSwirl / Vane control / Auto swingFan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiver

    Refer to each model PDB for applicable models.

    On_Off / Fan speed / Mode / Temp.

    -

    Weekly / Simple

    Max 2 hours

    On_Off / Fan speed / Mode / Temp.

    -

    -

    Weekly / Simple

    Max 2 hours

    -

    PDRCUSZ0PCRCUSZ0

    PCRCUSZ0 PDRCUSZ0

    PZRCUSB0

    On / Off LED

    Ventilation mode setting

    Rapid ventilation

    Power saving ventilation

    ReservationElectric failure compensation

    Child lock

    Optional function

    Weekly / Simple

    Max 2 hours

    Plasma / Heater / Humidifier / Operating air volume

    PZRCUSB0

    Deluxe Wired Remote ControllerREMOTE CONTROLLER

    PQRCUDS0 / PQRCUDS0B / PQRCUDS0S

    With the future-oriented design more suitable for the high-end interior,

    the deluxe wired remote controller makes a perfect match with interior.

    Rem

    ote

    Co

    ntroller

    08

    09

    PQRCUDS0 (White) PQRCUDS0B (Blue) PQRCUDS0S (Silver)

    FEATURES

    Operating mode

    Touch screen / LCD back_light

    Room temp

    Fan / Plasma / Swirl / Heater

    Vane control / Auto swing

    E.S.P function

    Reservation

    Timer function

    Child lock

    On_Off / Fan speed / Mode / Temp.

    Weekly / Simple

    PQRCUSDS0, PQRCUSDS0B, PQRCUSDS0S

    Refer to each model PDB for applicable models.

  • 8/7/2019 LG 2011 Accessories Catalog

    6/32

    Simple Wired Remote Controller10 11REMOTE CONTROLLER

    PQRCUCA0 / PQRCFCS0 / PQRNC0

    The simple wired remote controller with handy design is suitable for hotel

    or office applications because user can control air conditioner easily.

    Wireless Remote ControllerREMOTE CONTROLLER

    PQWRH(C)DF0/PQWRH(C)SF0PPWRH(C)SF0

    PQWRH(C)DF0 PQWRH(C)SF0 PPWRH(C)SF0

    The wireless remote controller allows the operation of

    air conditioner from any corner of the room.

    Rem

    ote

    Co

    ntroller

    10

    11

    FEATURES

    FEATURES

    COMBINATION

    PQRCUCA0

    (Simple)

    PQRCFCS0

    (Simple for Hotel)

    PQRNC0

    (Simple for operation with radiator)

    Operation modeMode change

    Room temp

    Plasma

    Auto swing

    Child lock

    Parts included

    On_Off / Fan speed / Mode / Temp.Cooling / Heating / Fan

    PQRCUCA0

    On_Off / Fan speed / Temp.Impossible

    PQRCFCS0

    On_Off / Fan speed / Mode / Temp.Auto change over

    -

    -

    PCB Case Cable

    PQRNC0

    Operating mode

    Room temperature checking

    Chaos swing / Jet cool

    On_Off timer

    Sleep mode auto

    Main / Sub setting of indoor units

    (For override function)

    T setting (for Auto Changeover)

    PPWRH(C)SF0On_Off / Fan speed / Mode / T emp

    -

    -

    PQWRH(C)DF0On_Off / Fan speed / Mode / T emp

    MULTI V SYNC II

    PQWRH(C)SF0On_Off / Fan speed / Mode / T emp

    -

    -

    MODEL NAME & APPLICABLE MODELS

    PQWRHDF0

    PQWRCDF0

    PQWRHSF0

    PQWRCSF0

    PPWRHSF0

    PPWRCSF0

    PAC

    Type

    H/P

    C/O

    H/P

    C/O

    H/P

    C/O

    CST, SRAC, CVT, Duct,

    Floor Standing Refer to each model PDB for applicable models.

    Applicable for only MULTI V II series (MULTI V PLUS II, MULTI V SYNC II, MULTI V SPACE II , MULTI V MINI & 08 new indoor units) Refer to each model PDB for applicable models.

  • 8/7/2019 LG 2011 Accessories Catalog

    7/32

    Central ControllerThe central controller offers more comfortable and convenient life by

    automatic control such as cooling, heating, ventilating, monitoring,scheduling, peak control, etc.

    CentralCo

    ntroller

    12

    13

    Simple Central Controller

    Function Controller & Scheduler

    AC Smart

    Deluxe Central Controller

    PC Based Central Controller

    ACP & AC Manager

    BNU(LONWORKS)

    BNU(BACnet)

    PI 485

    CNU

    14

    15

    16

    18

    20

    22

    24

    2526

    27

    Central Controller Line up

    Function PQCSB101S0

    On / Off

    Max. no. of indoor units

    Mode change

    Control of each room

    Total lock

    Error check

    Fan speed / Temperature control

    Schedule

    Ventilation control

    PDI Monitoring

    Web access

    Set temp. range restriction

    Auto Changeover

    Temperature limit control

    Histoy

    Interlocking function

    Multi language

    16

    LED

    PQCSB101S0+

    PQCSC101S0

    16

    LCD display

    PQCSB101S0+

    PQCSD130A0

    16

    LCD display

    Weeky

    PQCSW320A0E

    64(128)

    Self-diagnosis

    Weekly / Yearly

    PQCSW502A2

    256

    Self-diagnosis

    Weekly / Yearly

    PQCSS513A0

    2,048

    Self-diagnosis

    Weekly / Yearly

    PQCPB11A0E+

    PQCSS520A0E

    4,096

    Self-diagnosis

    Weekly / Yearly

  • 8/7/2019 LG 2011 Accessories Catalog

    8/32

  • 8/7/2019 LG 2011 Accessories Catalog

    9/32

  • 8/7/2019 LG 2011 Accessories Catalog

    10/32

    Deluxe Central Controller18 19CENTRAL CONTROLLER

    PQCSW502A2

    The deluxe central controller can control up to 256 indoor units, very convenient

    touch screen and GUI(Graphic User Interface) features makes it user friendly.

    CentralCo

    ntroller

    18

    19

    FEATURES

    CONTROL / MONITORING

    COMBINATION

    Max.no. of indoor units

    7 inch LCD panelConvenient GUI / Touch screen

    Contol / Monitoring

    Schedule management

    Group management

    User lock function

    Self-diagnosis function

    Peak control

    PDI monitoring

    Internet remote control

    Ventilation control & monitoring

    256 indoor units

    Need of PDI

    PQCSW502A2

    System Control & MonitoringTo check general control and monitoringfunctions of the air conditioner centralcontrol system such as group selection and airconditioner selection, air-conditioner control ,monitor function, etc.1Schedule Control

    Setup of a weekly schedule for all, group andindividual air conditioner enables operation ofthe system. Processing through enlist of extraschedule for a year is available.2Ventilator Control (Eco-V)

    To check general control and monitoringfunctions of the ventilation central controlsystem such as group selection and ventilatorselection, ventilator control, monitorfunction, etc.

    3Peak ControlTo control the maximum demand power.It has an effect on cutting down power costs

    by keeping the amount of all the airconditioners consumption lower thanDemand Power authorized

    4

    Ethernet(Direct UTP cable)

    Deluxe central controller

    PQCSW502A2

    AC220V

    PHNFP14A0 (Ceiling & Floor, Duct)

    PSNFP14A0 (CST, RAC)

    PHNFP14A0

    PMNFP14A0

    PMNFP14A0 (Max. 16 Indoors)

    PMNFP14A1 (Max. 48 Indoors)

    Single constant

    Ventilation

    Single A, MULTI

    CNU ( I-Gateway)

    PQNFG14B0

    HUB

    DC Comm, Line

    CNU 8

    RS485

    0.75mm2 X 2C (shield)

    For LGAP applied models

    MULTI V PLUS II

    MULTI V SYNC II

    MULTI V SPACE II

    MULTI V MINI

    MULTI V PLUS

    MULTI V SYNC

    MULTI V SPACE

    No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

  • 8/7/2019 LG 2011 Accessories Catalog

    11/32

    PC Based Central Controller20 21CENTRAL CONTROLLER

    PQCSS513A0

    Not only the controlling through PC in local network environment, but also remote

    control and monitoring of up to 2,048 indoor units can be facilitated using internet

    technology.

    CentralCo

    ntroller

    20

    21

    FEATURES

    COMBINATION

    OS: Windows XP (include Microsoft Java VM) CPU: Pentium4 2.2GHz or above RAM: 256MB or above

    HDD: Space with minimum 600MG or more Web browser: Internet Explorer 5.0 or above

    Classification

    Program installation

    Max. no. of indoor units

    Control / Monitoring

    Schedul management

    Group management

    User lock function

    Self-diagnosis function

    Peak control

    PDI Monitoring

    Internet remote control

    Ventilation control & monitoring

    Parts supplied

    User S.W. Engine

    Install with CD

    2048 Indoor units

    Need of PDI

    PQCSS513A0

    CONTROL / MONITORING

    System Control & MonitoringTo check general control and monitoringfunctions of the air conditioner centralcontrol system such as group selection and airconditioner selection, air-conditioner control ,monitor function, etc.1Schedule Control

    Setup of a weekly schedule for all, group andindividual air conditioner enables operation ofthe system. Processing through enlist of extraschedule for a year is available.2Ventilation Control (Eco-V)

    To check general control and monitoringfunctions of the ventilation central controlsystem such as group selection and ventilatorselection, ventilator control, monitorfunction, etc.

    3Peak ControlTo control the maximum demand power.It has an effect on cutting down power costs

    by keeping the amount of all the airconditioners consumption lower thanDemand Power authorized

    4

    CD Remote controller

    * PC is not supplied with PC Based Central Controller.

    USB Hard lock device

    For LGAP applied models

    Ethernet(Direct UTP cable)

    AC220V

    PHNFP14A0 (Ceiling & Floor, Duct)

    PSNFP14A0 (CST, RAC)

    PHNFP14A0

    PMNFP14A0

    PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)

    Single constant

    Ventilation

    Single A, MULTI

    CNU ( I-Gateway)

    PQNFG14B0

    HUB

    DC Comm, Line

    CNU 8

    RS485

    0.75mm2 X 2C (shield)

    MULTI V PLUS II

    MULTI V SYNC II

    MULTI V SPACE II

    MULTI V MINI

    MULTI V PLUS

    MULTI V SYNC

    MULTI V SPACE

    PC Based central

    controllerPQCSS513A0

    No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

  • 8/7/2019 LG 2011 Accessories Catalog

    12/32

    ACP & AC Manager22 23CENTRAL CONTROLLER

    PQCPA11A0E(Without IO) / PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)

    Through embedded web control function in ACP one can control and

    monitor various functions of air-conditioner such as temperature

    setting, schedule, peak power control, etc.

    CE N TRA L CON TROL L E R

    CentralCo

    ntroller

    22

    23

    COMBINATION

    FEATURES

    Max.no. of indoor units

    Control / Monitoring

    Schedule management

    Lock function

    Temperature range restriction

    Temperature limit function

    Auto Changeover functionHistory function

    Peak control

    PDI monitoring

    Interlocking function

    Printing function

    4,096 indoor units(16 ACP)

    Mode/Temp/Fan speed/Schedule

    Monitoring & Error history

    Need of PDI

    Fire sensor, Door sensor, Motion sensor...

    System setting, History, PDI

    PQCPB11A0E+PQCSS520A0E

    256 indoor units

    Temperature

    -

    -

    -Monitoring

    Need of PDI

    -

    -

    PQCPA(B)11A0E

    4,096 indoor units(16 ACP)

    Mode/Temp/Fan speed/Schedule

    Monitoring & Error history

    Need of PDI

    -

    System setting, History, PDI

    PQCPA11A0E+PQCSS520A0E

    KW

    Time

    Control /Monitor New FunctionUpgrade RemoteAccess Various ControllerCombination

    FireAlarm

    Stand Alone

    Operation

    Power Proportional

    Distribution

    Peak Power

    Control

    Schedule

    ACP

    PQCPA(B)11A0E

    AC Manager

    PQCSS520A0E

    AC220V

    PHNFP14A0 (Ceiling & Floor, Duct) / PSNFP14A0 (CST, RAC)

    PHNFP14A0

    PMNFP14A0

    PMNFP14A0 (Max. 16 Indoors) / PMNFP14A1 (Max. 48 Indoors)

    Single constant

    Ventilation

    Single A, MULTI

    DC Comm, Line

    Internet

    Internet

    Korean reference site.

    Max. 4,096 Indoor

    AC ManagerACP

    Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4096 indoor units & Max.16 ACP

    Application

    For LGAP applied models

    AC220V

    PHNFP14A0 (Ceiling & Floor, Duct) / PSNFP14A0 (CST, RAC)

    PHNFP14A0Max.16 ACP

    PMNFP14A0

    PMNFP14A0 (Max. 16 Indoors) / PMNFP14A1 (Max. 48 Indoors)

    Single constant

    Ventilation

    Single A, MULTI

    DC Comm, Line

    MULTI V PLUS II

    MULTI V SYNC II

    MULTI V SPACE II

    MULTI V MINI

    MULTI V PLUSMULTI V SYNC

    MULTI V SPACE

    MULTI V PLUS II

    MULTI V SYNC II

    MULTI V SPACE II

    MULTI V MINI

    MULTI V PLUS

    MULTI V SYNC

    MULTI V SPACE

    HUB

    No need of PI 485, when use MULTI V II series outdoor with '08 new indoor units.

  • 8/7/2019 LG 2011 Accessories Catalog

    13/32

  • 8/7/2019 LG 2011 Accessories Catalog

    14/32

    PI 48526 27CENTRAL CONTROLLER

    PMNFP14A1 / PMNFP14A0PHNFP14A0 / PSNFP14A0

    PI 485 convert the protocol of air conditioner to the RS 485

    protocol for central controller.

    PQNFG14B0

    CNU (Central Network Unit)

    CNU is the interface unit that transforms RS 485 communication of

    indoor and outdoor units to ethernet communication to be connected

    with PC or deluxe central controller for a high-quality central control.

    CNUCE N TRA L CON TROL L E R

    CentralController

    26

    27

    PI-485 LINE-UP

    WIRING DIAGRAM

    MODELS APPLIED

    EXTERNAL PHOTO: PQNFG14B0

    Model name : PMNFP14A0

    Power : Single phase AC 220V 50/60Hz

    Max. no of the indoor units

    that can be connected : 16 units

    Model applied : MULTI V, MULTI, Single A

    Model name : PMNFP14A1

    Power : Single phase AC 220V 50/60Hz

    Max. no of the indoor units that can be

    connected : 48 units

    Model applied : MULTI V

    Model name : PHNFP14A0

    Power : Connected with the indoor units

    Max. no of the indoor units that can beconnected : 1 units

    Model applied : Single (Duct, CVT) , Eco V

    Model name : PSNFP14A0

    Power : Connected with the indoor units

    Max. no of the indoor units that can beconnected : 1 units

    Model applied : Single (RAC, PAC, CST) Power: single phase 220V AC 50/60Hz

    Model name

    PQNFG14B0

    Models appliedMaximum no. of outdoor units that can be connected per CNU

    Deluxe Central Control le r PC Bas ed Central Control le r

    8 8 For LGAP applied models

    PI485 Connection

    BUS_A : PI485 A terminal[+]

    BUS_B : PI485 B terminal[-]

    AC/DC Adaptor

    Adaptor Connection

    DC 9V (supplied)

    RJ45 Connector

    Connected with the HUB

    Deluxe Central Controller

    DO Kit

    PQNFP00T0

    Do Kit is connected between ACP (AC Smart) and external devices.

    So ACP(AC Smart) can start and stop external devices such as light,

    pump, motor, etc.

    MULTI V II Series dont need any other PI 485 because MULTI V II series have PI 485 in its outdoor unit PCB.

    ( , , , &08 New indoor units)

    L N

    Power of Load

    BUS _ A

    BUS _ B

    Li gh t Pu mp M ot or e tcACP or AC Smart

  • 8/7/2019 LG 2011 Accessories Catalog

    15/32

    Electronic AccessoryA wide range of electronic accessories help to use

    our air conditioning system more coveniently.

    Electronic

    A

    ccessory

    28

    29

    PDI

    Dry Cntact

    Cool/Heat Selector

    Remote TemperatureSensor

    Zone Controller

    ElectronicThermostat

    CTI

    Low Ambient Kit

    Telecom ShelterController

    30

    32

    33

    34

    35

    36

    37

    38

    39

    30 31

  • 8/7/2019 LG 2011 Accessories Catalog

    16/32

    PDI30 31ELECTRONIC ACCESSORY

    PQNUD1S00

    For the multi indoor units connected to an outdoor unit, the individual

    units and total system power consumption can be displayed on the device.

    This system can also be connected to a remote metering system.

    ELECTRONIC ACCESSORY

    Electronic

    A

    ccessory

    30

    31

    POWER INDICATOR OVERVIEW

    COMBINATION

    This device displays the power consumed for each

    indoor air conditioner unit that shares an outdoor unit.

    The power consumed by each indoor unit connected

    with the joint power line is indicated on the device.

    The information of the power distributed can be sent on

    a real-time basis through the remote metering system.

    FEATURES

    Accumulated total power consumption indicated Accumulated/Current power consumption of each indoor unit indicated.

    Accumulated power consumption by month indicated

    Max. connectable no. of indoor units : 48 indoor units

    1 PDI per 1 outdoor unit

    Power failure-proof function : Data back up on EEPROM even if power turns off

    Connectable to PC based central controller

    Simple connection with the remote metering system (RS485 approach)

    Power distribution indication formula

    31

    1

    2

    LCD indication window

    3 Label indicating the locations of each indoor unit

    2 Key operation section

    *Weight by room: Weight calculated based on the temperature set by room, mode and operating time.

    = Power used per roomTotal power consumed

    for an external unit

    weight by room

    total weight

    (under 16 indoor units)

    Pluse Out(1,2,4,5,8,10W/pulse)

    AC 200V~240V 50/60Hz

    Pluse Out(1,2,4,5,8,10W/pulse)

    AC 200V~240V 50/60Hz

    (Over 16 Indoor units)

    In the case of , dont need PI-485

    ( , , , &08 New indoor units)

    [Installation without PC based central controller]

    PQNUD1S00

    RS485

    RS485

    Digital WHM

    (Local Purchase)

    Digital WHM

    (Local Purchase)

    PQNUD1S00

    AC220V

    AC220V

    or

    or

    PMNFP14A0 :

    (under 16 indoor units)

    PMNFP14A1 :

    (over 16 indoor units)

    PMNFP14A0 :

    (under 16 indoor units)

    PMNFP14A1 :

    (over 16 indoor units)

    Pluse Out(1,2,4,5,8,10W/pulse)

    AC 200V~240V 50/60Hz

    [Installation with PC based central controller]

    PQNUD1S00

    PQNFG14B0 PQCSS513A0

    RS485

    Digital WHM

    (Local Purchase)

    AC220V

    In the case of , dont need PI-485

    ( , , , &08 New indoor units)

    32 33

  • 8/7/2019 LG 2011 Accessories Catalog

    17/32

    Dry Contact32 33ELECTRONIC ACCESSORY

    PQDSA(B) / PQDSB1 / PQDSBC

    It is connected between indoor units and external device,

    so it can be used for various purpose

    Cool/Heat SelectorELECTRONIC ACCESSORY

    PRDSBM

    This switch enables selection of heating, cooling or fan mode. So it can prevent

    that cooling & heating mixing error occurs during the change of season.

    Electronic

    A

    ccessory

    32

    33

    FEATURES FEATURES

    MODELS APPLIED

    WIRING DIAGRAMPARTS DESCRIPTION

    System Structure

    Dry contact(Contact point linked

    with Outer part)

    CN-POWER : AC 220V connector

    CN-CC : MAINPCB connector

    CN-DRY(L) : DRY CONTROLLER connector

    CN-DRY(SIG) : DRY CONTROLLERconnector

    CN-DRY(ERROR CHECK) : ERROR check display connector

    CN-DRY(OPER STATE) : Operation display connector

    Key Switch Lighting Sensor Fire Alarm Timer Motion

    Detect Sensor

    Door Chek Sensor

    Contact point

    Power input

    Voltage / Non voltage input

    On_Off control

    Lock / Unlock

    Fan speed setting

    Thermo off

    Energy saving

    Temperature setting

    Error monitoring

    Operation monitoring

    PQDSBCPQDSA(B)

    1 Control point

    AC 220V from outside power source

    -

    -

    -

    -

    -

    -

    PQDSB1

    1 Control point

    AC 24V from outside power source

    -

    -

    -

    -

    -

    -

    2 Control points

    DC 5V&12V from indoor unit PCB

    Refer to each model PDB for applicable models. With case model : PQDSB, PQDSB1, PQDSBC

    Without case model : PQDSA

    CN_INDOOR2 : Connector for Main Dry Contact

    CN_INDOOR1 : PI 485 Connector

    CHANGE_OVER_SW : Switch for selecting junction signal - Voltage(5V~12V) or Non Voltage

    CN_CONTROL : Connector for input junction signal CONTROL_MODE_SW : Switch for selecting control mode

    SETTING_SW : Switch for selecting Dry Contact setting function

    TEMP_SETTING : Switch for setting desired temperature

    CN_OUT(O1,O2) : Terminal Block for displaying main operation

    CN_OUT(E3,E4) : Terminal Block for displaying main error

    DISPLAY_LED : LED for displaying status of Dry Contact

    RESET_SW : Reset Switch

    Connect terminals(, , GND) on the back side of Cool/Heat Selector to

    terminals (, , GND) of Outdoor Main PCB.

    Max. communication line length : 300m

    Fan Mode

    Cooling

    Fan Mode

    Heating

    Indoor unit control without central controller

    Select operation mode : Cooling, Heating, Fan mode

    Mode lock for cooling & heating mixing error-proof during the change of season.

    34 35

  • 8/7/2019 LG 2011 Accessories Catalog

    18/32

    Remote Temperature Sensor34ELECTRONIC ACCESSORY

    PQRSTA0

    Sensor for detecting the room temperature.

    FEATURES

    It can help to detect the exact room temperature at the optimal position.

    MODELS APLLIED

    Ceiling cassette type

    Ceiling concealed duct type

    PARTS INCLUDED

    Remote temperature sensor Extension cable (15m) Manual

    WIRING DIAGRAM

    1. Wire to the control box in the indoor unit by removing the

    existing thermistor and connect the extension cable its

    place.

    2. Cut the extension cable to the appropriate length and

    connect the screw terminal of the remote sensor.

    3. In the case of wired remote controller installed, set the

    temperaturesensing slide s/w at MAIN mode.

    Connector

    Indoor unit

    Remote TemperatureSensor

    Extension cable

    Screw terminal

    connection

    Zone Controller35ELECTRONIC ACCESSORY

    ABZCA

    Controls air conditioning in up to 4 zones.

    FEATURES

    Controls different zones (up to 4 zones)

    Maintain proper temperature of each zone

    Auto variation of dampers

    Auto control of fan speed

    MODELS APPLIED

    Ceiling Concealed Duct ( High Static Pressure) Refer to each model PDB for applicable modles

    PARTS INCLUDED

    WIRING DIAGRAM

    COMPONENTS

    Factory supplied :Zone co nt ro ll er P CB (1 EA ) Trans fo rme r (1 EA) Case ( 1E A) Cov er (1 EA )

    Main lead wires (1EA) Screws (1EA) Holder (4EA) Installation manual (1EA)

    Purchased locally (reference siemens, honneywell)Damper Motor Thermostat Damper

    ROOM1temperaturesensor

    Auto Damper

    Auto Damper

    Auto Damper

    Auto Damper

    Zone Control

    sub PCB

    ROOM2temperaturesensor

    ROOM3temperaturesensor

    ROOM4temperaturesensor

    Electronic

    A

    ccessory

    34

    3 5

    36ELECTRONIC ACCESSORY 37ELECTRONIC ACCESSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    19/32

    36

    Electronic ThermostatELECTRONIC ACCESSORY

    AQETC

    Simple and easy control of system.

    Electronic

    A

    ccessory

    36

    37

    FEATURES

    Less complicated in operation (simple controls).

    Built in thermister for better control.

    MODELS APPLIED

    NAME AND DESCRIPTION OF THE SYSTEM

    WIRING DIAGRAM

    Ducted Split ( 3~5RT) / Single Package (3~ 5RT) Refer to each model PDB for applicable models

    FEATURES

    Transfer each local contact signal from Thermostat to Unitary product

    MODELS APPLIED

    PARTS INCLUDED

    WIRING DIAGRAM

    Unitary

    R : 24V(+)

    C : 24V(-)G : Fan

    Y1 : Cooling changeover

    W1 : Heating changeover

    Y1 : Comp1

    Y2 : Comp2

    EM : Emergency

    W1 : Heater1

    W2 : Heater2

    CTI PCB(1EA) 11Pin Cable(to connect with Unitary PCB) Transformer 3Pin Cable(to connect with Unitary PCB)

    Manual

    CTI37ELECTRONIC ACCESSORY

    PKFC0

    Communicate with other Mechanical Thermostat and Unitary product

    38ELECTRONIC ACCESSORY 39ELECTRONIC ACCESSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    20/32

    38

    Low Ambient KitELECTRONIC ACCESSORY

    AQLA

    To cool you even in winter.

    FEATURES

    Depending on the condensing temperature, speed of outdoor fan is varied automatically while compressor is ON.

    Maintains cooling function for very low ambient temperature such as (-5C).

    Specific installation requirements

    - Gymnasium, Control rooms, Machine rooms, Computer rooms

    Simple and easy to install

    Used only for cooling mode

    MODELS APPLIED TO

    Convertible, Ceiling Concealed Duct

    Single split

    Ceiling Cassette (Refer to each model PDB for applicable models)

    Multi Split(Specific models)

    PARTS INCLUDED

    WIRING DIAGRAM

    AQLA fan speed controller 1EA

    Sensor assembly 1EA

    Buckle-clip 3EA

    Adhesive insulation, 20mm x 80mm 1EA

    Tie wrap,100mm 2EA

    Instruction manual 1EA

    Screw 3EA

    Main power from

    outdoor PCB

    Power supply

    To fans

    Connection with

    4 way valve (1)

    Connection with

    temperature sensorprovided

    Connection with 4 way

    valve(2)

    > For multi system

    N NL L

    Electronic

    A

    ccessory

    38

    39

    Automatically start and stop air conditioner by turns

    Display internal temperature of shelter on LCD

    Sense water leakage and humidity

    Control ventilation fan.

    Fire alarm function

    Error display

    Low ambient function

    Electric failure compensation

    Telecom Shelter Controller39ELECTRONIC ACCESSORY

    PQCSA001T0

    This controller is suitable for telecom shelter. It can control and monitor air conditioner

    in telecom shelter.

    FEATURES

    COMBINATION

    Auto Rotation of Air conditioner

  • 8/7/2019 LG 2011 Accessories Catalog

    21/32

    Mechanical AccessoryFor comfort and convenience.

    MechanicalA

    ccessory

    40

    41

    ARTCOOL Panel

    Electric Heater

    Plasma Air Purifier

    Drain Pump Kit

    Suction Grille / Canvas

    Auto Elevation Grille

    Cassette Cover

    Air Guide

    42

    44

    46

    47

    48

    49

    50

    51

    Mechanical Accessory Line up and Application

    ARTCOOL Panel

    Electric Heater

    Plasma Air Purifier

    Drain Pump Kit

    Suction Grille / Canvas

    Auto Elevation Grille

    Plasma Kit

    Cassette Cover

    Air guide

    ARTCOOL indoor unit

    Single package / Ducted split

    Ceiling concealed duct(High static)

    Ceiling concealed duct

    Ceiling concealed duct (Built-in)

    4 Way Cassette

    4 Way Cassette

    4 Way Cassette

    Outdoor unit

    Model

    Single Type Multi Type Multi V Type Remark

    4342ME CHANICAL ACCE SSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    22/32

    MechanicalA

    ccessory

    42

    43

    ACCESSORY MODEL NAME

    DETAILS OF MODEL NAME

    Gogh

    Sisley

    White wood

    Blue

    Wood

    Metal

    Mirror

    Cherry

    Silver

    Red

    Gold

    White Silver

    Type

    Chassis

    Color

    PSAPPAA10

    PSAPPAS10

    PSAPPCW10

    PSAPPCB10

    PSAPPCD10

    PSAPPCM10

    PSAPVCW10

    PSAPVCB10

    PSAPVCD10

    PSAPVCM10

    PSAPUCW10

    PSAPUCB10

    PSAPUCD10

    PSAPUCM10

    PSAPUCR10

    PSAPUCC10

    PSAPZCW10

    PSAPZCB10

    PSAPZCD10

    PSAPZCM10

    PSAPZCR10

    PSAPZCC10

    PSAP3CW10

    PSAP3CB10

    PSAP3CD10

    PSAP3CM10

    PSAP3CR10

    PSAP3CC10

    PSAPECB10

    PSAPECR10

    PSAPECV10

    PSAP8CB10

    PSAP8CR10

    PSAP8CV10 PSAPFCV11

    PSAPFCE11

    PSAPFCG11

    PSAPFCH11

    SP2 SV2 SU SZ S3 SE S8 SF

    ARTCOOL PanelME CHANICAL ACCE SSORY

    A unique blend of art and colors.

    MODELS APPLIED TO

    All ARTCOOL models

    ARTCOOLPanel

    ARTCOOLWide

    ARTCOOLSF chassis

    ARTCOOLMirror

    ARTCOOL Wide Type

    White wood Blue Wood Metal

    ARTCOOL Panel Type

    ARTCOOL SF Chassis

    Wood MetalBlueWhite wood

    Silver Red Gold White silver

    Gogh Sisley

    White wood Blue Wood

    Metal Mirror Cherry

    Blue Mirror Silver

    ARTCOOL Mirror Type

    1 2 3 4 5 6 7 8 9

    P S A P P C R 1 0

    Serial no.

    Number of panel

    * Color

    Chassis

    ARTCOOL front panel

    Single split wallMounted air conditioner

    Parts

    AA : Gogh

    AS : Sisley

    CB : Blue

    CC : Cherry

    CD : Wood

    CE : Red

    CG : Gold

    CH : White Silver

    CM : Metal

    CR : Mirror

    CV : Silver

    CW : White Wood

    * Panel color

  • 8/7/2019 LG 2011 Accessories Catalog

    23/32

    46ME CHANICAL ACCE SSORY 47ME CHANICAL ACCE SSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    24/32

    Plasma Air Purifier Drain Pump Kit

    ABPAHH / ABPAHC

    ABPAGH / ABPAGCABPAEH / ABPAEC, ABPARH / ABPARC

    Clean and healthy living.

    MechanicalA

    ccessory

    46

    47

    FEATURES

    Provide odor free, dust free, allergy free, clean & healthy air.

    Remove microscopic contaminants, dust, house mites, pollen and pet fur to help prevent allergic diseases

    like asthma.

    Plasma air purifier assembly (AC 220~240V, 50/60Hz)

    Plasma air Purifier assembly(1EA) Installation manual(1EA)

    Screws M4(12EA)

    Wired remote controller(1EA)

    MODELS APPLIED TO

    Ceiling concealed duct _ High static type (refer PDB for applicable models)

    ACCESSORY MODEL NAME

    DETAILS OF MODEL NAME

    PARTS SUPPLIED

    DIMENSION

    1 2 3 4 5 6A B P A H C

    Type (H : H/P, C : C/O)

    Chassis

    Accessory namePlasma Air Purifier

    Ceiling concealed duct

    Accessory

    1 2 3 4 5

    A B D P G

    Chassis

    Accessory nameDrain Pump Kit

    Ceiling concealed duct

    Accessory

    ABDPE

    ABDPGABDPT

    Effectively drains out condensed water.

    ABPAHH

    ABPAHC

    ABPAGH

    ABPAGC

    ABPAEH/ABPARH

    ABPAEC/ABPARC

    Heat pump

    Cooling only

    Heat pump

    Cooling only

    Heat pump

    Cooling only

    TypeModel Name Capacity (Btu/h)

    18K 24K 30K 36K 42K 48K 60K

    Model

    ABPAHHABPAHC

    ABPAGHABPAGC

    ABPAEHABPAECABPARHABPARC

    785

    1,092

    1,235

    230

    260

    350

    180

    180

    180

    Dimension

    W H D

    FEATURES

    In some places where natural drainage is not possible drain pump is very useful to pumps out condensed

    water from indoor unit.

    Drain pump assembly (AC 220~240V, 50/60Hz)

    For G/H/R/T Chassis Models : Drain pump assembly(1EA)

    (AC 220~240V,50/60Hz,400CMM)

    Screw(4EA)

    Cap(1EA)

    Installation manual(1EA)

    For E Chassis Models : Drain pump assembly(1EA)

    (AC 220~240V,50/60Hz,400CMM)

    Elbow (32)(1EA) Hose(1EA)

    Tie wrap(2EA) Screw(10EA)

    Rubber(1EA) Installation manual(1EA)

    MODELS APPLIED TO

    Ceiling concealed duct (refer PDB for applicable models)

    ACCESSORY MODEL NAME

    DETAILS OF MODEL NAME

    PARTS SUPPLIED

    APPLICATION

    Multi V Type

    Multi Type

    Single Type

    Model Name

    Default

    Default

    E Chassis

    ABDPE

    G/H/R Chassis

    ABDPGDefault

    T Chassis

    ABDPT

    (Unit : mm)

    48ME CHANICAL ACCE SSORY 49ME CHANICAL ACCE SSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    25/32

    Suction Grille / Canvas

    PBSGB30 / PBSGB40PBSC30 / PBSC40

    High flexibility for a wide variety of applications

    MechanicalA

    ccessory

    4 8

    49

    FEATURES

    High external static pressure facilitates unit use with flexible ducts of varying lengths.

    When using suction panel, unit requires only 270mm of ceiling space.

    Blends unobtrusively with any interior decoration.

    For the suction grille : Suction panel with air filter (1EA)

    Suction panel fix bolt M5x18 (4EA)

    Installation manual (1EA)

    For suction grille

    For the suction canvas : Air suction canvas (1EA)

    Screws for air suction canvas (4EA)

    Adjusting chain (4EA)

    Screws for adjusting chain (8EA)

    Installation manual (1EA)

    MODELS APPLIED TO

    ACCESSORY MODEL NAME

    DETAILS OF MODEL NAME DIMENSION

    PARTS SUPPLIED APPLICATION

    Grille

    Canvas

    PBSGB30

    PBSGB40

    PBSC30

    PBSC40

    Model NameTypeCapacity (Btu/h)

    7K 9K 12K

    PBSGB30

    PBSGB40

    15K 18K 24K

    Ceiling concealed duct _ Built-in type

    (refer PDB for applicable model)

    MODELS APPLIED TO

    4 Way cassette_Single, Multi V II

    (refer PDB for applicable models)

    Auto elevation grille kit Install the kit insideindoor unit

    Install the front paneland the Inlet grille

    Operate the autoelevation grille by thewireless remotecontroller

    Easy maintenance

    Inlet Grille (1EA)

    Auto elevation grille kit (1EA)

    Wireless Remote Controller (1EA)

    Screws (4EA)

    Installation manual (1EA)

    C

    A

    B A

    B

    C

    Auto Elevation Grille

    PTEGM0

    Easy filter cleaning with elevation grille

    FEATURES

    DETAILS OF MODEL NAME

    APPLICATION

    PARTS SUPPLIED

    Auto Horizontal Control4-Point Support Structure Auto Bottom DetectionMemory for users level

    A

    910

    1188

    B

    359

    359

    C

    56

    56

    PBSC30

    PBSC40

    A

    821

    1100

    B

    274

    274

    C

    42~250

    42~250

    1 2 3 4 5 6 7

    P B S G B 3 0

    Serial Number

    Chassis

    Bottom Suction

    Suction Grille

    Duct

    Part

    For suction canvas

    1 2 3 4 5 6

    P B S C 3 0

    Serial Number

    Chassis

    Suction Canvas

    Duct

    Part

    1 2 3 4 5 6

    P T E G M 0

    Serial No.

    Chassis

    Elevation Grille Kit

    Ceiling Cassette

    Part

    max.4.5m

    STOP

    Memory

    (Unit : mm) (Unit : mm)

    50ME CHANICAL ACCE SSORY 51ME CHANICAL ACCE SSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    26/32

    Plasma Kit

    PTPKM0

    Plasma air purifying system

    FEATURES

    It can remove microscopic contaminants and dust

    and house mites, pollen, pet fur to help prevent

    allergic diseases like asthma.

    MODELS APPLIED TO

    4Way cassette - Single Multi V II

    (refer PDB for applicable models)

    Plasma Kit (1EA)

    Screws

    Installation Manual (1EA)

    Air Guide

    PQAGA

    Easy air discharge at odd places.

    FEATURES

    Converts vertical discharge into horizontal discharge.

    Designed for outdoor discharge air.

    Direction of air discharge can be changed by simple installation.

    Installation flexibility

    Light weight

    MODELS APPLIED TO

    MULTI V type, MULTI type, Single A (UY, UW Chassis)

    DETAILS OF MODEL NAME

    DIMENSION APPLICATION

    1 2 3 4 5

    P Q A G A

    Chassis

    Air Guide

    Common Using

    Part

    MechanicalA

    ccessory

    5 0

    51

    Cassette Cover

    PTDCD / PTDCD1 / PTDCM

    Maintains the ceiling elegance.

    FEATURES

    Specially designed for indoor unit. Covers the side area of cassette.

    Gives elegant looks.

    Light weight. Suitable when false ceiling is unavailable.

    MODELS APPLIED TO

    ACCESSORY MODEL NAME

    Ceiling cassette - 4Way

    (TD, TD1, TH, TP, TN, TM)

    PARTS SUPPLIED

    Cover A (4EA), Cover B (4EA)

    Cover C (4EA), Cover D (4EA)

    Screws

    Installation Manual (1EA)

    PTDCD

    PTDCD1

    PTDCM

    PT-CD0, PT-CD1, PT-HD0, PT-HD1

    PT-CDA1, PT-CDC1, PT-HDA1, PT-HDC1

    PT-UMC

    Model Name Front Panel

    DETAILS OF MODEL NAME

    1 2 3 4 5 6

    P T P K M 0

    Serial No.

    Chassis

    Plasma Kit

    Ceiling Cassette

    Part

    PARTS SUPPLIED

  • 8/7/2019 LG 2011 Accessories Catalog

    27/32

    Piping AccessoryGlobal No.1 seller, LG Air Conditioner!

    For comfort and convenience.

    Piping

    Accessory

    5 2

    5 3

    Y Branch & Header

    Branch (Synchro)

    Branch Distributor

    Heat Recovery Unit

    Y Branch & Branch Kit(Multi Fdx)

    Y Branch & Header

    Branch(Multi V)

    54

    56

    58

    60

    61

    Piping Accessory Line up and Application

    Y Branch and Header

    Branch(Synchro)

    Branch Distributor (Multi)

    Heat Recovery Unit

    Y Branch and Branch Kit

    (Multi)

    Y Branch and Header

    Branch(Multi V)

    Synchro

    Multi Mdx / Multi Fdx

    Multi V Sync

    Multi Fdx

    Multi V Plus / Multi V Sync

    Multi V Space / Multi V Mini

    Model

    Synchro Type Multi Type Multi V Type Remark

    54

    Y B h d H d B hPIPING ACCESSORY 55PIPING ACCE SSORY

    ( S h )

  • 8/7/2019 LG 2011 Accessories Catalog

    28/32

    Y Branch and Header Branch

    Piping

    Accessory

    5 4

    55

    FEATURES

    ACCESSORY MODEL NAME

    PIPING DIAGRAM

    Various Y-branch pipe of different capacities make Synchro installation much easier.

    Y-branch and header branch for both gas and liquid are provided.

    Insulation material is also provided for covering the branches.

    Synchro

    MODELS APPLIED TO

    Refrigerant distribution channel.

    Gas Pipe

    Liquid Pipe

    ( Synchro )

    2 branch 3 branch 4 branch

    2 Units

    3 Units

    4 Units

    Connectable of Indoor Units Models Liquid PipeGas Pipe

    PMUB 11A

    PMUB 23A

    PMUB 112A

    PMUB 122A

    PMUB 111A

    PMUB 1111A

    ( 1 : 1 )

    ( 2 : 3 )

    ( 1 : 1 : 2 )

    ( 1 : 2 : 2 )

    ( 1 : 1 : 1 )

    ( 1 : 1 : 1 : 1 )

    ( 1 : 1 )

    ( 2 : 3 )

    ( 1 : 1 : 2 )

    ( 1 : 2 : 2 )

    ( 1 : 1 : 1 )

    ( 1 : 1 : 1 : 1 )

    PMUB11A, PMUB 23A (2units)PMUB112A, PMUB122A, PMUB111A (3units)PMUB1111A (4units)

  • 8/7/2019 LG 2011 Accessories Catalog

    29/32

  • 8/7/2019 LG 2011 Accessories Catalog

    30/32

    60

    Y Branch and Branch Kit (MULTI Fdx)PIPING ACCESSORY 61PIPING ACCE SSORY

    Y Branch and Header Branch (MULTI V)PIPING ACCE SSORY

  • 8/7/2019 LG 2011 Accessories Catalog

    31/32

    Y Branch and Branch Kit (MULTI Fdx)

    1, 3

    Piping

    Acce

    ssory

    60

    61

    FEATURES

    APPLICATION

    ACCESSORY MODEL NAME

    Y Branch and Branch kit make Multi Fdx installation much easier.

    Y-Branch and Branch kit for both gas and liquid are provided.

    Insulation material is also provided for covering the branches.

    PARTS SUPPLIED Y Branch for Gas side and Liquid side (1 set)

    Installation manual (1EA)

    MODELS APPLIED TO

    Refrigerant distribution channel

    PMBL3620 / PMBL5620 (2units)

    PMBL1203F0 (3units)

    Model Name No. of BD units Applicable ModelSpecification

    LiquidGas

    PMBL3620

    PMBL5620

    PMBL1203F0

    2 units

    2 units

    3 units

    Only 3, 36k Btu/h

    1, 3

    1, 3

    15.88 15.88

    15.88

    19.05 19.05

    19.05

    9.52 9.52

    9.52

    6.35 6.35

    6.35

    Y Branch and Header Branch (MULTI V)

    FEATURES

    PIPING DIAGRAM

    ACCESSORY MODEL NAME

    Various Y-branch pipe of different capacities make MULTI V installation much easier.

    Y-branch and header branch for both gas and liquid are provided.

    Insulation material is also provided for covering the branches.

    MODELS APPLIED TO

    For refrigerant distribution in multi indoor units.

    Header Branch

    Y Branch

    Outdoor unit

    Y- branch Header branch

    R22 / R410A

    Models

    4 branch / ARBL054

    7 branch / ARBL057

    4 branch / ARBL104

    7 branch / ARBL107

    10 branch / ARBL1010

    10 branch / ARBL2010

    Gas pipe Liquid pipe

    (Unit : mm)

    (Unit : mm)

    Header Branch / Y Branch

    Header Branch

  • 8/7/2019 LG 2011 Accessories Catalog

    32/32