Installation, Operation andMaintenace ManualENM 10 Level regulator
-
Introduction
Purpose of this manual
The purpose of this manual is to provide necessary information for:
Installation
Operation
Maintenance
CAUTION!Read this manual carefully before installing and using the product. Improper use of theproduct can cause personal injury and damage to property, and may void the warranty.
NOTE! Save this manual for future reference, and keep it readily available at the location ofthe unit.
Inspect the delivery
Inspect thepackage
1. Inspect the package for damaged or missing items upon delivery
2. Note any damaged or missing items on the receipt and freight bill
3. File a claim with the retail dealer if anything is out of order.If the product has been picked up at a distributor, make a claim directly to thedistributor
Inspect theunit
1. Remove packing materials from the product. Dispose of all packing materials inaccordance with local regulations
2. Inspect the product to determine if any parts have been damaged or are missing
3. If applicable, unfasten the product by removing any screws, bolts, or straps. Foryour personal safety, be careful when you handle nails and straps
4. Contact your retail dealer if anything is out of order
2 Installation, Operation and Maintenace Manual, ENM 10 Level regulator
-
Safety
WARNING!
The operator must be aware of safety precautions to prevent physical injury
Operating or installing the unit in any way that is not covered in this manual couldcause death, serious personal injury, or damage to the equipment. This includesany modification to the equipment or use of parts not provided by your retaildealer. If there is a question regarding the intended use of the equipment, pleasecontact your retail dealer before proceeding
Do not change the service application without the approval of an authorizedservice representative
CAUTION!You must observe the instructions for installation, operation, and maintenancecontained in this manual. Failure to do so could result in physical injury, damage,or delays.
Safety message levels
About safetymessages
It is extremely important that you read, understand, and follow the safety messages andregulations carefully before handling the product. They are published to help preventthese hazards:
Personal accidents and health problems
Damage to the product
Product malfunction
DefinitionsSafety message level Indication
DANGER!A hazardous situation which, if not avoided,will result in death or serious injury
WARNING!A hazardous situation which, if not avoided,could result in death or serious injury
CAUTION!A hazardous situation which, if not avoided,could result in minor or moderate injury
Installation, Operation and Maintenace Manual, ENM 10 Level regulator 3
-
Safety message level Indication
High Voltage
HIGH VOLTAGE!The possibility of electrical risks ifinstructions are not followed in a propermanner
NOTE! A potential situation which, if not avoided,could result in undesirable conditionsA practice not related to personal injury
User safety
General safetyrules
These safety rules apply:
Always keep the work area clean
Pay attention to the risks presented by gas and vapors in the work area
Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flashhazards
Always bear in mind the risk of drowning, electrical accidents, and burn injuries
Electricalconnections
Electrical connections must be made by certified electricians in compliance withall international, national, state, and local regulations. For more information aboutrequirements, see sections dealing specifically with electrical connections.
Hazardousliquids
The product is designed for use in liquids that can be hazardous to your health. Observethese rules when you work with the product:
Make sure that all personnel who work with sewage systems are vaccinated againstdiseases to which they may be exposed
Observe strict personal cleanliness
Wash the skinand eyes
Do the following if chemicals or hazardous fluids have come into contact with your eyes oryour skin:
4 Installation, Operation and Maintenace Manual, ENM 10 Level regulator
-
If you need to wash your... Then...
Eyes Hold your eyelids apart forcibly with your fingers
Rinse the eyes with eyewash or running water forat least 15 minutes
Seek medical attention
Skin Remove contaminated clothing
Wash the skin with soap and water for at leastone minute
Seek medical attention, if required
Environmental safety
The work area Always keep the station clean to avoid and/or discover emissions.
Recyclingguidelines
Always recycle according to these guidelines:
Follow local laws and regulations regarding recycling if the unit or parts are acceptedby an authorized recycling company
If the first guideline is not applicable, then return the unit or parts to your retail dealer
Waste andemissionsregulations
Observe these safety regulations regarding waste and emissions:
Appropriately dispose of all waste
Handle and dispose of the processed liquid in compliance with applicableenvironmental regulations
Clean up all spills in accordance with safety and environmental procedures
Report all environmental emissions to the appropriate authorities
Electricalinstallation
For electrical installation recycling requirements, consult your local electric utility.
Electrical Data
Country Electrical Data
Canada 5 A, 250 V, DC10 A, 250 V AC
Installation, Operation and Maintenace Manual, ENM 10 Level regulator 5
-
Country Electrical Data
Denmark 10 A, 250 V, AC
Switzerland 6 A, 250 V, AC
Sweden 10 A, 230 V, AC Resistive load3A, 250 V, AC Inductive load5 A, 30 V, DC Resistive load*1 mA, 5 V, DC, Gold Contact
* Part no: 594 79 19 & 594 79 20
Approvals
CE, CSA, SEMKO, NEMKO, DEMKO, EX
LVD approval according to EN61058
CSA approval: Cert no. 1330172Cl.I Zone 0, Gr. IIC;CL.I Div.1 Gr A, B, C&D;Cl.II Gr. E, F&G;Cl.III when installed to the certified Intrinsically Safe relay, Ex ia, rated for the locations persubmitter control drawing and installation manual.
6 Installation, Operation and Maintenace Manual, ENM 10 Level regulator
-
Product DescriptionOverview The simplest possible method for level control! A mechanical switch in a plastic casing,
freely suspended at the desired height from its own cable. When the liquid level reachesthe regulator, the casing will tilt and the mechanical switch will close or break thecircuit, thereby starting or stopping a pump or actuating an alarm device. No wear, nomaintenance! In sewage pumping stations, for ground water and drainage pumping infact, for most level control applications the ENM-10 is the ideal solution.
The regulator casing is made of polypropylene and the cable is sheathed with a specialPVC or Nitrile/PVC rubber compound. The plastic components are welded and screwedtogether. Adhesive is never used. Impurities and deposits will not adhere to the smoothcasing.
The level regulator contains a micro switch, max rated 250 VAC/10 A.
NOTE! In many cases, local codes require that the regulator be connected to a low-voltagesupply, even though it is approved for a higher voltage.
We recommends that the regulator be connected to a low-voltage supply, 48 or 24V, and a protective transformer.
Special rules apply to installation in an explosive atmosphere. Intrinsically safe circuits arenormally required (Ex i). Use a EX-safety barrier (e.g. Prod. no. 84 01 07).
The ENM-10 is available in different versions for different liquid densities.
As standard, the regulator can be obtained with 6, 13, 20, 30 or 50 metres (20, 42, 65,100 or 167 feet) of cable for liquids with specific density between 0.95 and 1.10 g/cm3; forother specific densities.
The regulator can withstand up to 60C (140F).
The guarantee does not cover faults caused by deficient maintenance, improperinstallation, incorrectly executed repair work or normal wear and tear.
We assumes no liability for either bodily injuries, material damages or economic losses.
Productcoverage
This manual cover the standard version Red casing of ENM-10.
FunctionalDescription
1 32 4
1. When the pumped media reaches a predetermined level, the upper level regulatortips over to horizontal position and the pump starts draining the basin.
2. The basin is drained of fluid.3. The pump stops when the lower level regulator returns to the vertical position.4. The basin starts filling up again, and the process starts all over again.
Installation, Operation and Maintenace Manual, ENM 10 Level regulator 7
-
Installation
Avoid damagethe levelregulatorduringinstallation
Do not crossthe levelregulatorcables duringinstallation
Level Regulator
Connectionillustration
To conform to local regulations, the level regulators are normally connected through atransformer to a low-tension control circuit.
Two regulators are used; one for starting and one for stopping.
A third regulator can be connected if an alarm is required at a given level.
Identical regulators can be used for all functions.
8 Installation, Operation and Maintenace Manual, ENM 10 Level regulator
-
Emptying Filling
M3
M2
M124V
Start
Stop
M3
M2
M124V
Stop
Start
Connectiontable Cable 1 2 3
Color EU, GreyUS, Red
Black EU, BrownUS, White
Connections for emptying a sump X X Insulate
Connections for filling a tank X Insulate X
Cable colors
1 2 3 1 2 3
See table above to identify related cable colors.
Installation, Operation and Maintenace Manual, ENM 10 Level regulator 9
-
Connection of Level Regulator for Audible or Visible Alarm
Connectionillustration
AlarmHigh Level
AlarmLow Level
1 21 3
1 2 3 1 2 3
Connectiontable Cable 1 2 3
Color EU, GreyUS, Red
Black EU, BrownUS, White
Alarm high level X X Insulate
Alarm low level X Insulate X
Maintenance
ENM-10 is very durable and practically maintenance free. You only have to check on itoccasionally, to ensure its continual operation.
It is recommended to occasionally clean ENM-10, and especially when fat/greasecovers the plastic surface
At the same time, make an occular inspection of the regulator to make sure neithercable, protective sleeve or plastic casing show any signs of damage
A damaged ENM-10 cannot be repaired in any way, due to the hermeticencapsulation. If the unit is found to be damaged, replace it with a new one
10 Installation, Operation and Maintenace Manual, ENM 10 Level regulator
-
899752_1.0_en.US_2010-08_IOM.ENM10_OEM