Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential...
Transcript of Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential...
![Page 1: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/1.jpg)
Leica ScanStation P50/P40/P30
Quick GuideVersion 2.0English
![Page 2: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/2.jpg)
1 Important Information about your InstrumentRead and follow the User Manual on the accompanying data storage device beforeusing the product.
Keep for future reference!
• Measuring horizontal and vertical angles.• Measuring distances.• Scanning objects.• Capturing and recording images.• Recording measurements.• Computing with software.• Remote control of product.• Data communication with external appliances.
The ScanStation P50/P40/P30 instrument contains the following laser products:
Laser product Laser class
EDM (Electronic Distance Measurement) module Class 1
Laser plummet Class 1
☞
Intended use
Laser products
2 Important Information about your Instrument
![Page 3: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/3.jpg)
The classification is in accordance with IEC 60825-1 (2014-05).
008030_001
a
b c
a Laser beamb Laser beam
(Laser plum-met)
c Exit for laserbeam (Laserplummet)
Locations of laserapertures
3 Important Information about your Instrument
![Page 4: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/4.jpg)
The product must not be disposed with household waste.
• FCC Part 15 (applicable in US)
• Hereby, Leica Geosystems AG, declares that the radio equipment typeScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. The declara-tion of conformity can be consulted at http://www.leica-geosystems.com/ce.
Class 1 equipment according European Directive 2014/53/EU(RED) can be placed on the market and be put into servicewithout restrictions in any EEA member state.
• The conformity for countries with other national regulations not coveredby the FCC part 15 or European directive 2014/53/EU has to be approvedprior to use and operation.
Conformity tonational regula-tions
4 Important Information about your Instrument
![Page 5: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/5.jpg)
• Japanese Radio Law and Japanese Telecommunications Business LawCompliance.• This device is granted pursuant to the Japanese Radio Law (電波法)
and the Japanese Telecommunications Business Law(電気通信事業法).
• This device should not be modified (otherwise the granted designa-tion number will become invalid).
5 Important Information about your Instrument
![Page 6: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/6.jpg)
2 Instrument Components
007863_002
a
b
c
d
e
f
g
hijkl
m
n
a Antennab Removable handlec Rotating mirror (laser and
camera aperture)d Battery compartment Be Circular levelf Socket for power supply, 5
pin female with blue colourring
g Socket for time synchroni-zation, 9 pin female
h ON/OFF buttoni USB socketj Loudspeakerk Stylusl Touchscreenm Battery compartment An Ethernet socket, 8 pin
female with grey colourring
Components of theScanStationP50/P40/P30
6 Instrument Components
![Page 7: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/7.jpg)
3 Technical DataTemperature range:
Type Operating temperature[°C]
Storage temperature[°C]
Instrument -20 to +50 -40 to +70
AC-power supply 0 to +40 -25 to +65
Protection against water, dust and sand:
Type Protection
Instrument IP54 (IEC 60529)
Dust protected
Protection against splashing water from any direction
Humidity:
Type Protection
Instrument Max 95 % non condensing
EnvironmentalspecificationsScanStationP50/P40/P30
7 Technical Data
![Page 8: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/8.jpg)
4 Care and Transport• Carry the product in its original container or carry the tripod with its legs
splayed across your shoulder, to protect the product against shock and vibra-tion.
• Periodically carry out test measurements and perform the field adjustmentsindicated in the User Manual, particularly after the product has been drop-ped, stored for long periods or transported.
Care and transport
8 Care and Transport
![Page 9: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/9.jpg)
5 OperationThe battery must be charged before using it for the first time.
2s > ON2s > OFF
008031_001
1
2
3
4
5
☞Turning on and offthe instrument
9 Operation
![Page 10: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/10.jpg)
6 EC Declaration of ConformityThis corresponds to EN ISO/IEC 17050-1.
We, Leica Geosystems AG, CH-9435 Heerbrugg (Switzerland), declareunder our sole responsibility that the product(s) ScanStation P50/P40/P30,following the provision of Directive(s)
• 2006/42/EC Machinery (MD)• 2004/108/EC Electromagnetic compatibility (EMC)• 2014/53/EU Radio and telecommunications terminal equipment
(RED) (in accordance with annex II / III)• 2011/65/EU Restriction of hazardous substances (RoHS)
to which this declaration relates, is in compliance with the following standards:
EC Declaration ofConformity
10 EC Declaration of Conformity
![Page 11: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/11.jpg)
• EN 55022:2010• IEC 60825-1:2014• EN 61000-6-1:2007• EN 61000-6-3:2007 + A1:2011• EN 300328 2.1.1• EN 301 489-1 V2.1.1:2017-02• EN 301 489-17 V3.1.1:2017-02
Leica Geosystems AG
☞ For a signed version and translations into the official EU lan-guages please refer to: http://www.leica-geosystems.com/ce
11 EC Declaration of Conformity
![Page 12: Leica ScanStation P50/P40/P30 … · ScanStation P50/P40/P30 is in compliance with the essential require-ments and other relevant provisions of Directive 2014/53/EU. ... indicated](https://reader034.fdocuments.net/reader034/viewer/2022042709/5f4c6868889af37cb6396d73/html5/thumbnails/12.jpg)
827778-2.0.0enOriginal text Printed in Switzerland© 2017 Leica Geosystems AG, Heerbrugg, Switzerlandwww.leica-geosystems.com