Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt...

4
Company Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 Inside USA (877) 474-8209 International (510) 490-2187 Fax (510) 490-15 m o c . r e w o p l a i r t s u d n i o c m e t . w w w 7 0 Dimensions, weight, and impedeance may vary slightly from the information provided. For certified drawings, please contact a TEMCo representative. 113627.00 INDUSTRIAL POWER SUPPLY Leeson Single Phase Electric Motor Type: Horsepower: RPM: Rotation: Frame size: Enclosure: Mounting: Connection box: Shaft diameter: Shaft type: Shaft height (from base): Overall length: Overall height: Bearing type: Frame material: Phase: kW: Voltage: Amps (full load): Frequency (Hz): Service factor: Duty cycle: Full load efficiency: Integrated overload protection: Base type: Mounting Hole Pattern Length: Mounting Hole Pattern Width: Agency Approvals: Warranty: Weight (pounds): LxWxH (inches): Table Saw Motor 1.5 3600 Clockwise 182T 56 Foot Side 0.625” Smooth shaft w/ .19 x .19 Key 3.5” 12.31” 8.78” Ball bearings Rolled steel Single 1.119 115/230 7.5 60 Hz 1 Continuous-use rated 72% Yes Rigid 3” 4.88” UL Listed (E49747), CSA Approved (LR2025) 12 months from date of installation or 18 months from date of manufacture 39 12.31 x 8.54 x 8.78

Transcript of Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt...

Page 1: Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt c.c.w. p1 t2,t4 t5 p2,t3 t8---c.w. p1 t2,t4 t8 p2,t3 t5---a 1:1 unless specified

Company Headquarters: TEMCo – Tower Electric Motor Company 41474 Christy Street Fremont, CA 94538 Inside USA (877) 474-8209 International (510) 490-2187 Fax (510) 490-15 moc.rewoplairtsudniocmet.www 70

Dimensions, weight, and impedeance may vary slightly from the information provided. For certified drawings, please contact a TEMCo representative.

113627.00

INDUSTRIAL POWER SUPPLY

Leeson Single Phase Electric Motor

Type:

Horsepower:

RPM:

Rotation:

Frame size:

Enclosure:

Mounting:

Connection box:

Shaft diameter:

Shaft type:

Shaft height (from base):

Overall length:

Overall height:

Bearing type:Frame material:

Phase:

kW:

Voltage:

Amps (full load):

Frequency (Hz):

Service factor:

Duty cycle:

Full load efficiency:

Integrated overload protection:

Base type:

Mounting Hole Pattern Length:

Mounting Hole Pattern Width:

Agency Approvals:

Warranty:

Weight (pounds):

LxWxH (inches):

Table Saw Motor

1.5

3600

Clockwise

182T

56

Foot

Side

0.625”

Smooth shaft w/ .19 x .19 Key

3.5”

12.31”

8.78”

Ball bearings

Rolled steel

Single

1.119

115/230

7.5

60 Hz

1

Continuous-use rated

72%

Yes

Rigid

3”

4.88”

UL Listed (E49747), CSA Approved (LR2025)

12 months from date of installation or

18 months from date of manufacture

39

12.31 x 8.54 x 8.78

Page 2: Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt c.c.w. p1 t2,t4 t5 p2,t3 t8---c.w. p1 t2,t4 t8 p2,t3 t5---a 1:1 unless specified

7/2/2007 7:46:42 PM -

Page 3: Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt c.c.w. p1 t2,t4 t5 p2,t3 t8---c.w. p1 t2,t4 t8 p2,t3 t5---a 1:1 unless specified

7/22/2011 1:42:19 PM

RBC PROPRIETARY AND CONFIDENTIAL INFORMATIONThis document is the property of REGAL BELOIT CORPORATION ("RBC") including

its subsidiaries and divisions and contains proprietary information of RBC. This document

is loaned on the express condition that neither it nor the information contained therein shall

be disclosed to others without the express written consent of RBC, and that the information

shall be used by the recipient only as approved expressly by RBC. This document shall be

returned to RBC upon its request. This document may be subject to certain restrictions

under U.S. export control laws and regulations.

1

2

3P1

T5

T2

T3

T4

T8

P2

T5

T6T5

T1 T1

P1

P2

T2

T3

T4

T5

T1

M

T6

S

M

T8

T5

2

3

1

T1

005003-03 06

WLW 08/20/79ADN 08/27/76WRK 08/27/76

EXTERNAL WIRING DIAGRAMTYPE "C" W/PROTECTORDECAL - 004011

00500303

INCHES±.1±.01±.005±.0005±1/2°

0506

REDRAWN ON CADREDRAWN IN SOLIDWORKS

DBTVJB

05/27/977/22/2011

VIEW FROM OUTSIDE OF MOTOR AT SWITCH ENDLINE LEADS

ROTATION FACING

LEAD ENDL1 L2 JOIN INSULATE

SEPARATELY

HIGH VOLT

C.C.W. P1 T4 T5

T2,T3 T8 P2

C.W. P1 T4 T8

T2,T3 T5 P2

LOW VOLT

C.C.W. P1 T2,T4 T5

P2,T3 T8 ---

C.W. P1 T2,T4 T8

P2,T3 T5 ---

A

1:1

UNLESS SPECIFIEDTOLERANCES

DRAWING NOSIZE REV

MAT'L

TITLE

NO REVISION BY & DATE FINISH

FMF

REF

SCALE

RFP

APPR

DRAWN

CHK

PREV

ANG

.XXXX

.XXX

.XX

.X

DEC

CHK PAGE

NETWORK FILE NAME

OF

THIRD ANGLE PROJECTION

Page 4: Leeson Single Phase Electric Motor 113627 · t4 t5 t2,t3 t8 p2 c.w. p1 t4 t8 t2,t3 t5 p2 low volt c.c.w. p1 t2,t4 t5 p2,t3 t8---c.w. p1 t2,t4 t8 p2,t3 t5---a 1:1 unless specified

7/22/2011 8:57:51 AM

RBC PROPRIETARY AND CONFIDENTIAL INFORMATIONThis document is the property of REGAL BELOIT CORPORATION ("RBC") including

its subsidiaries and divisions and contains proprietary information of RBC. This document

is loaned on the express condition that neither it nor the information contained therein shall

be disclosed to others without the express written consent of RBC, and that the information

shall be used by the recipient only as approved expressly by RBC. This document shall be

returned to RBC upon its request. This document may be subject to certain restrictions

under U.S. export control laws and regulations.

PRESSURE CONNECTORS INSULATE SEPARATELY

T8T4T3 T5T2P2

WHITE

GREEN

BLACK

GREEN

P1FROM

PROTECTOR

T1T1

PRESSURECONNECTORS

WIRE NUTS &TAPE

D.P.S.T.

GREEN

BLACK

230 VOLT PLUG

SWITCH

WHITE

T1

PROTECTORFROM

T1

FROMWINDING

T8T2 T4

TAPE

D.P.S.T.

WIRE NUTS &

T5T3P1

GREEN

BLACK

GREEN

WHITE

AND T8

CAUTION

INTO CONNECTORINSULATION

WHITE

SWITCH

115 VOLT PLUG

GREEN

BLACK

FROMWINDING

CW ROTATIONFACING LEAD END

FOR CCW ROTATIONINTERCHANGE LINES T5

LEAD WIRE INSULATIONTO EXTEND MIN OF 1/4"

P2

005003-02 12

JRW 05/21/75

6C34FB3

WIRING DIAGRAM FOR CORD

PAGE 2

00500302

INCHES±.1±.01±.005±.0005±1/2°

1112

REDRAWN ON CADREDRAWIN IN SOLIDWORKS

MTBVJB

04/11/977/22/2011

A

1:1

UNLESS SPECIFIEDTOLERANCES

DRAWING NOSIZE REV

MAT'L

TITLE

NO REVISION BY & DATE FINISH

FMF

REF

SCALE

RFP

APPR

DRAWN

CHK

PREV

ANG

.XXXX

.XXX

.XX

.X

DEC

CHK PAGE

NETWORK FILE NAME

OF

THIRD ANGLE PROJECTION