LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to...

9
Light efficiency: 137 Lumen/Watt CRI: 82.6 Color temperature: 5010 K 165 Beam angle Spectra T 314.743.3067 F 314.972.6202 180 165 116 ° CIE 1931 x: 0.346 y: 0.359 Output: 55211 Im Peak: 18992 cd Power: 403 W email: commerc[email protected] .superbrightleds.com/ LED UFO High Bay HBUD-5000W Product name: HBUD-50K400W Date and time: 3/5/2019 11:07:34 AM

Transcript of LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to...

Page 1: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

Light efficiency:

137 Lumen/Watt

CRI: 82.6

Color temperature:

5010 K

165

Beam angle

Spectra

T 314.743.3067

F 314.972.6202

180 165

116°

CIE 1931 x: 0.346

y: 0.359

Output: 55211 Im

Peak: 18992 cd

Power: 403 W

email: [email protected]

www.superbrightleds.com/

LED UFO High Bay HBUD-50K400W

Product name:

HBUD-50K400W

Date and time:

3/5/2019 11:07:34 AM

Page 2: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

Color Specifications

5010 K

#

#---t---r--,f--

0.1 0.2 0.3 0.4 0.5 0.6

CIE 1931

TM30: 81.3

: : . : : :• .

.

n n I I I I l�rr1!!!!!!!!!!!!!!!

I I 1111111111111111 1111111111111111 1111111111111111

• • : I I

CRI R values, onl R1-R8 are used to calculate final CRI value

� � � � � ITT � � �0 �1 �2 �3 �4 �5

80.5 88.0 92.9 81.9 80.8 82.9 87.2 66.8 6.2 71.2 80.6 58.9 82.6 96.3 74.3

TM30 C values, 16 binned values out of total of 99 C values

C1 C2 C3 C4 cs CB Cl CB C9 C10 C11 C12 C13 C14 C15 C16

72.8 82.8 78.7 86.1 87.9 93.6 89.0 83.3 81.2 70.9 72.0 82.9 85.0 84.0 71.5 77.4

CQSQvalues

Q1 Q2 Q3 Q4 QS QB Q7 QB Q9 Q10 Q11 Q12 Q13 Q14 Q15

82.2 98.5 77.0 73.2 79.2 81.8 84.6 88.8 96.9 86.4 82.4 81.3 81.2 69.9 74.5

Color parameters

Color temperature

CCT

5010 K

Color rendering Red component inde,

CRI

82.6

T 314.743.3067

F 314.972.6202

CRIR9

6.2

Color fidelity Col°'gamut

TM30 Rf TM30Rg

81.3 93.7

email: [email protected]

www.superbrightleds.com/

Cob-quality ... ,.

CQS

80.9

LED UFO High Bay HBUD-50K400W

t.uv: 0.0012

CIE 1931 ZOOM

CRI: 82.6 (R1-R8)

93

88

81

67

R1 R2 R3 R4 RS R6 R7 RS

CQS: 80.9

Cob°COOl"dinate Cok>rcoordinate Cok>rC001"dinate Color coordinate Color dlvlatlon cie1931 cie1931 from black body

X y u V il.uv

0.346 0.359 0.209 0.326 0.0012

Page 3: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

100

90

GI 80 ::, .c

..0

ii: 70

60

50

20%

GI 15% ::,

;.10% ..0

= 5%

CII 0%

-5% .c

-10%

-15%

-20%

100

80

� 60 ,,

� 40 ,,

20

0

Gra hie shifts % Hue Bin R1 Chroma Hue

1 73 -13% -1%

Rf 81.3 2 83 -7% 5% 3 79 -5% 9% 4 86 -1% 6%

Fidelity index Rf 5 88 -2% 3% 6 94 0% -1% 7 89 -6% -2% 8 83 -9% 1% 9 81 -10% 11%

Rg 93.7 10 71 -5% 15%11 72 3% 16%12 83 6% 6% 13 85 8% -6%

Gammut index Rg 14 84 3% -7% 15 71 -2% -18%16 77 -5% -12%

94

Hue bin

Hue bin

LED UFO High Bay HBUD-50K400W

140 0 0 14\ Approx. limits for sources

\..V on the Planckian locus.

130 I----+-- ,';;\ Approx. limits for \.V practical light sources.

120 t------+---+---;-----...

� 100

80 t-----+---+--�11

70 I-----+-----

60 '-'--'-'-...,__,____,_.,._._..__.__....__.__._._._'-'--'-'-...,__,____,_., ........... 50 60 70 Rf 80 90 100

ITTl��ll�II �11 111111; I 11111111111 1111 �-lfflll 1m1�n11 111111111111111 I I II II 1111 11111111 I 11111111111 1111 111111111�1 I I I I I I I I 1111111 � 1111111 111111111111111 I I I I I I 1111 11111111 I 11111111111 1111 I I I I I 111111111111111 I 111111111111111 111111111111111 I I I I I I 111 I 11111111111 11 I I I I I 111111111111111 111111111111111 I

- - - � � � - :: -: - . • •. • - s: . • •. • - . • •. • ,;, . . . : . : . :. : - . • • • . • : • • :ii : - : - =� ;; - . . .. . :.: ...... ·: .. :· .. :: ·; .: . . . .· . .- . -� :

T 314.743.3067 F 314.972.6202 email: [email protected]

www.superbrightleds.com/

Color Evaluation Sample

Page 4: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

LED UFO High Bay HBUD-50K400W

T 314.743.3067

F 314.972.6202

email: [email protected]

www.superbrightleds.com/

Beam intensities from 1-20m

1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 13m 14m 15m 16m 17m 18m 19m 20m

3.3ft 6.6ft 9.8ft 13.1ft 16.4ft 19.7ft 23ft 26.2ft 29.5ft 32.8ft 36.1ft 39.4ft 42.7ft 45.9ft 49.2ft 52.5ft 55.8ft 59.1ft 62.3ft 65.6ft

19021lx 4755lx 2113lx 1189lx 761lx 528lx 388lx 297lx 235lx 190lx 157lx 132lx 113lx 97lx 85lx 74lx 66lx 59lx 53lx 48lx

1767.1fcd

441.8fcd

196.3fcd

110.4fcd

70.7fcd 49.1fcd 36.1fcd 27.6fcd 21.8fcd 17.7fcd 14.6fcd 12.3fcd 10.5fcd 9fcd 7.9fcd 6.9fcd 6.1fcd 5.5fcd 4.9fcd 4.4fcd

Beam angle 50% Field angle 10% Cutoff angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

116° 155.6° 166.9° 81.0% 54.6%

8.2 ft (2.5 m)

16.4 ft (5 m)

24.6 ft (7.5 m)

32.8 ft (10 m)

41 ft (12.5 m)

Distance feet

(meter)

131.2 ft (40 m)

116°

105 ft (32 m)

78.7 ft (24 m)

52.5 ft (16 m)

26.2 ft (8 m)

Foot-candles* (Lux)*

*measured at center of beam

Beam Width feet

(meter)

11 fc (122 lx)

31 fc (338 lx)

18 fc (190 lx)

71 fc (761 lx)

283 fc (3043 lx)

Illumination

Page 5: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

ISO Diagrams ISO candela diagramgoo

-75°

90m

72m

54m

36m

-54m

-72m

Horizontal angles

ISO lux diagram

T 314_743_3067 Mounting height: 10 meters (33 feet)

F 314.972.6202

email: [email protected]

www.superbrightleds.com/

LED UFO High Bay HBUD-50K400W

295.3f

236.2f

-177.2f

-236.2f

10% 1899 cd

20% 3798 cd

30% 5698 cd

40% 7597 cd

50% 9496 cd

60% 11395 cd

70% 13294 cd

80% 15193 cd

90% 17093 cd

Conditions:

Number of c-planes: 16

Candela at center: 18992 cd

3% 5.70 Ix

5% 9.50 Ix

10% 19.0 Ix

30% 57.0 Ix

50% 95.0 Ix

Conditions:

Number of c-planes: 16

Lux at center: 190 Ix

Lux distribution on a surface when lamp is mounted at 10 meters from the surface.

Page 6: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

LED UFO High Bay HBUD-50K400W

UGR Glare Evaluation According to UGR

p Ceiling 70 70 50 50 30

pWalls 50 30 50 30 30

p Floor 20 20 20 20 20

Room size Viewing direction at right angles to

X y lamp axis

2H 2H 40.4 41.7 40.7 41.9 42.2

3H 41.8 42.9 42.1 43.2 43.5

4H 42.2 43.3 42.5 43.6 43.9

6H 42.4 43.4 42.7 43.7 44.0

8H 42.4 43.4 42.8 43.7 44.0

12H 42.4 43.3 42.8 43.7 44.0

4H 2H 41.0 42.1 41.4 42.4 42.7

3H 42.5 43.5 42.9 43.8 44.2

4H 43.1 43.9 43.5 44.3 44.6

6H 43.3 44.1 43.8 44.4 44.8

8H 43.4 44.0 43.8 44.4 44.9

12H 43.4 44.0 43.8 44.4 44.8

8H 4H 43.3 43.9 43.7 44.3 44.7

6H 43.6 44.1 44.1 44.6 45.0

8H 43.7 44.1 44.2 44.6 45.1

12H 43.7 44.1 44.2 44.6 45.1

12H 4H 43.2 43.8 43.7 44.3 44.7

6H 43.6 44.1 44.1 44.5 45.0

8H 43.7 44.1 44.2 44.6 45.1

Variation of the observer position for the luminaire distance S

S = 1.0H +0.1 I -0.2

S = 1.5H +0.3 I -0.5

S = 2.0H +0.6 I -0.9

Standard table BK04

Correction 26.0

summand

Corrected glare indices referring to 55211 Im total luminous flux

T 314.743.3067

F 314.972.6202

email: [email protected]

www.superbrightleds.com/

70 70 50 50 30

50 30 50 30 30

20 20 20 20 20

Viewing direction parallel to lamp axis

40.4 41.7 40.7 41.9 42.2

41.8 42.9 42.1 43.2 43.5

42.2 43.3 42.5 43.6 43.9

42.4 43.4 42.7 43.7 44.0

42.4 43.4 42.8 43.7 44.0

42.4 43.3 42.8 43.7 44.0

41.0 42.1 41.4 42.4 42.7

42.5 43.5 42.9 43.8 44.2

43.1 43.9 43.5 44.3 44.6

43.3 44.1 43.8 44.4 44.8

43.4 44.0 43.8 44.4 44.9

43.4 44.0 43.8 44.4 44.8

43.3 43.9 43.7 44.3 44.7

43.6 44.1 44.1 44.6 45.0

43.7 44.1 44.2 44.6 45.1

43.7 44.1 44.2 44.6 45.1

43.2 43.8 43.7 44.3 44.7

43.6 44.1 44.1 44.5 45.0

43.7 44.1 44.2 44.6 45.1

+0.1 I -0.2

+0.3 I -0.5

+0.6 I -0.9

BK04

26.0

Page 7: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

LED UFO High Bay HBUD-50K400W

Road Report LCS table

BUG rating: BS U3 G3

Forward light Lumens

Low{0-30): 7508.6

Medium(30-60): 14798.8

HiQh(60-80): 4976.1

Very high{80-90): 232.5

Back light

Low(0-30): 7508.6

Medium(30-60): 14798.8

High{60-80): 4976.1

Very high{80-90): 232.5

Upliaht

Low(90-100): 18.7

High{100-180): 160.3

LCS graph

26.8%

UL 90-100°

18.7 Im 0%

BVH 80-90°

232.5 Im 0.4%

9%

BM 30-60°

14798.8 Im 26.8%

BL 0-30°

T 314.743.3067 ?5018.6 I�

F 314.972.6202 3·61/o

email: [email protected]

www.superbrightleds.com/

20.1%

13.4%

Lumens %

13.6%

26.8%

9%

0.4%

13.6%

26.8%

9%

0.4%

0%

0.3%

FL 0-30°

7508.6 Im 13.6%

UH 100-180°

160.3 Im 0.3%

UL 90-100°

18.7 Im 0%

FVH 80-90°

232.5 Im 0.4%

4976.1 Im

FM 30-80°

14798.8 Im 26.8%

Page 8: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

100%

99.1%

98.3%

97.4%

96.6%

LED UFO High Bay HBUD-50K400W

Stabilization Warmup curve

� I"-. -3.4% variatio 11 in 20 n �in 13 SE

� r----......

..............

� r---_

r--------

2 min 4min 6 min 8min 10 min 12 min 14 min 16 min 18 min

1 sec 2 sec 3 sec 5 sec 6 sec 7 sec 9 sec 10 sec 11 sec

Warmup result

Warmup time: 20 min 13 sec

Warmup variation -3.4%

Warmup conditions

Stable period: 15min

Stable change max: 2.0%

Minimum time: 15min

Color temperature change

CCT start

4922 K

Output start

57146 Im

T 314.743.3067

F 314.972.6202

email: [email protected]

www.superbrightleds.com/

CCT change CCTend

+88 K 5010 K

Output change

Output change Output end

-1935 Im 55211 Im

20

13

min

sec

Page 9: LED UFO High Bay · 2019-03-21 · LED UFO High Bay HBUD-50K400W UGR Glare Evaluation According to UGR p Ceiling 70 70 50 50 30 pWalls 50 30 50 30 30 p Floor 20 20 20 20 20 Room size

LED UFO High Bay HBUD-50K400W

Flicker Flicker curve (complete sampled flicker signal)

f-------------------------------------------------------------------------------------------------------------1

Flicker frame (frame of one flicker period)

®� -- -----�!�;W�,�----------------------------------------------------------------------------------

0% Cycle time: 8.35ms (119.8 Hz)

Flicker FFT (frequency scope of flicker curve)

Flicker results:

Flicker frequency:

Flicker index:

Flicker percentage:

SVM: (Visual flicker)

Flicker conditions:

I Sample rate:

T 314.743.3067

F 314.972.6202

email: [email protected]

www.superbrightleds.com/

Span O - 2000Hz

119.76 Hz

0

0.38%

0.01

40000 samples/second