LED · the Base is Mechanically Strong and Heat-Resistant up to 435°F (225°C) • Safe and...
Transcript of LED · the Base is Mechanically Strong and Heat-Resistant up to 435°F (225°C) • Safe and...
Page: 1 of 3
High Performance 10W LED Plug & Play Dimmable VL Lamp
The HyLite High Performance LED VL Lamp is an ideal Energy-Efficient replacement for CFL and Incandescent Bulb installations in Existing and New Fixtures. The 10W LED VL Lamp provides Energy-Efficient Illumination at a Wide Beam Angle of 120° and replaces 18W/26W/32W CFL Bulbs, effectively reducing Energy Consumption by 44%-62%-69%, and as much as 90% when replacing 100W Incandescent Bulbs. HyLite LED VL Lamps are rated at up to 50,000 hours of Lamp Life. This is 50 times longer than a traditional Incandescent Bulb, and 7 times longer than a CFL Bulb. This significantly reduces Energy Usage and Costs as well as Maintenance Expenditures.
Ideal for High-quality Illumination in:
• DownLights • WallScones • WallPacks
• DecorativeLighting • AccentLighting • CeilingLights
• PendantLights • WalkwayLighting • TaskLighting
• StairwellLighting • CorridorLighting • CarriageLanterns
IncreasedSustainability
Up to50,000Hours
Longer Life
Reduction ofup to 90%
Energy Costs
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
LM-80 TestedISTMT Tested
Reliability
Vibration andShock Resistant
Solid State
78 LpWLM-79 Tested
Lumen Efficacy
Reliable andLong-Lasting
Warranty
5years
LowConsumption
Power
Wide andUniform
120°
Beam Angle12W
HL-VLF-12W-G244100K
100~277V, AC
Zero Interference
No EMi / RFi12W
HL-VLF-12W-G244100K
100~277V, AC
PLUG-iN LAMP TM
LED
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
5.25
” (13
3 m
m)
2.25
”
(58
mm
)
2” (50 mm)
HL-VL-G24A-10W10W, 100~277V
Incandescent Halogen CFL HyLite
100W 55W 18W / 26W / 32W 10W
90% 82% 44%-62%-69% Energy Savings (%)
Replacewith
HL-VL-G24A-10W10W, 100~277V
HL-VL-G24A-10W100~277V, 0.3A, 10W, 50/60 Hz
10WE361357
98% RecyclableNo Lead, Mercury,
Heavy Metals, or Toxic Gases
18W / 26W / 32WCFL Equivalent
E361357
• SimplyPlug&Play:Ballast Compatible (Check the Ballast Compatibility List on last page). No Wiring Change Necessary.
• FullBrightnesswithInstantOnandInstantRestrike
• OptimalDesignforHorizontalorVerticalMountSockets
• >80CRIforGreatVisibility
• SuitableforDryorDampLocation
• LowPowerConsumption
• UniversalVoltage:100-277V,AC
• Heat&ImpactResistant,UVProtected,Non-Yellowing,OpticalGradeLens
• ExcellentHeatDissipationwithProprietary-DesignedHeatSink
• CoolOperation:DoesnotaddtoHeatLoad(upto90%lessheatthan Incandescent) while producing Brilliantly Bright Light
• Non-Combustible.MadefromFlameRetardant,EngineeredPolymer, theBaseisMechanicallyStrongandHeat-Resistantupto435°F(225°C)
• SafeandReliable:IsolatedCircuitDesign
• Maintenance-FreeOperation:Lastsupto50timeslongerthan IncandescentBulb.LowersCostsbyReducingRelampFrequency
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements. Facilitates LEED® points
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
Type ABallast Compatible
Not Suitable for
Enclosed Fixtures
Page: 2 of 3
Model Delivered Input Line Dimensions & Weight (each) No. Watts Lumens* Current Width Height Net Weight
HL-VL-G24A-10W 10 822 36mA~100mA 2”(50mm) 5.25”(133mm) 6oz.(170g)
HyLite VL Lamp, HL-VL-G24A-10W
Photometrics
Intensity: (Unit, cd)0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
HL-VL-G24A-10W10W, 100~277V
1 m3.3 ft.
2 m6.5 ft.
3 m9.8 ft.
4 m13.1 ft.
5 m16.4 ft.
223.83 lx20.79 fc
55.96 lx5.2 fc
24.87 lx2.32 fc
13.99 lx1.3 fc
8.95 lx0.83 fc
3.06 m10 ft.
6.11 m20 ft.
9.16 m30 ft.
12.22 m40 ft.
15.27 m50 ft.
87.23 lx8.10 fc
21.81 lx2.03 fc
9.69 lx0.90 fc
5.45 lx0.51 fc
3.49 lx0.32 fc
IlluminanceDistance Curve
Note: The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance
Height Angle: 119.60° DiameterCenter E (lx/fc) Ave. E (lx/fc)
0
60.0
120.0
180.0
240.0
299.9 Angle [50% Max.] [10% Max]C180/360 119.3° 204.6°C0/180 119.3° 204.6°C90/270 118.7° 200.3°
OrderingforHyLite10WLEDPlug&PlayVLLampwithG24Base
Model Suffix (CCT,ºK)
HL-VL-G24A-10W -35K 3500K=NeutralWhite(NW) -40K 4000K=Cool White (CW) -50K 5000K=DayLight(DL)
PLUG-iN LAMP TM
LED
As part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
Type ABallast Compatible
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-20°C(-4°F)toaMaximumof+45°C(113°F)
• Efficacy:78LpW* • CRI:>80 • BeamAngle:120º • Max.THD(%):<10%
• PowerFactor:>0.9 • Protection:IP20 • RatedLife:50,000Hrs.* • Warranty:5Years
• AmbientWorkingTemperature:-4ºF~+113ºF(-20ºC~+45ºC) • BaseType:G24 • UniversalInputVoltage
• CCT:3500K(NeutralWhite),4000K(CoolWhite)and5000K(DayLight). 100~277V,AC50/60Hz.
* Depending upon Ballast
** Depending upon the ambient temperature of the installation location
WARNINGNotSuitableforTotallyEnclosed Luminaires or Fully Enclosed Fixtures
Warning - Risk of Fire or Electric Shock• Disable all Power to the Lamp before Inspection,Installation,orRemoval. Failure to do so will createaHazardousandFatalWorkingEnvironment.TheInstallermustdetermineandverify whether120Vto277VACisbeingutilizedattheLuminairebeforeInstallation.ImproperVoltagematchingcanresultinPerformanceDegradationand/orPhysicalDamage.
• WiringmodificationforHyLiteLEDLampInstallationrequiresknowledgeofLuminaireElectricalSystems.Ifnotqualified,DONOT attempt Installation. Contact a Qualified Electrician. DONOTMakeorAlteranyOpenHolesinanEnclosureforWiringorElectricalComponentsduringInstallation.
• SuitableforuseinDryorDampLocations.DonotusewheredirectlyexposedtoLiquid,Vapor,RainorWeather.Non-Submergible(notwatertight).Lampmustbeinstalledinaccordancewith National,State,and/orLocalElectricalCodes.DoNotOpen–NoUserServiceablePartsInside.
• TopreventearlyLampfailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaminimumof-20°C(-4°F)toamaximumof+45°C(113°F).
• LuminaireWiring,Ballast,orotherElectricalPartsmaybeDamagedwhenInstalling.AlwayscheckforenclosedWiringandComponents.DONOTBlockLightemanatingfromProductinWhole or Part, as this may Cause an Unsafe Condition. To prevent Wiring Damage or Abrasion, DONOTexposeWiringtoedgesofSheetMetalorotherSharpObjects.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation.ThiswillensureLumen MaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.
• NotforuseonaDimmerorRemoteControls.ThisLampmustbecontrolledonlybyeitheraSwitchoranElectronicPhotosensor.DonotuseaMechanicalSensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.
Not Suitable for
Enclosed Fixtures
Warning:HyLiteLED10W“TypeA”Plug-inLampsaredesignedtoworkoff100V~277V,AC.HyLiteLED10W“TypeA”Plug-inLampsarecompatible with Electronic Ballasts.SeeBallastCompatible List. HyLiteLED10W“TypeA”Plug-inLamps are only Dimmable if used with Dimmable Electronic Ballasts.Itistheuser’sresponsibilitytocheckandverifywhethertheElectronic Ballast is Dimmable or Non-Dimmable.
FailuretoFollowInstructionswillVOIDWarranty.ItcanalsoresultinanElectricShock,orFire.NOTFORTOTALLYENCLOSEDLUMINAIRESOREMERGENCYLIGHTING.NOTFORUSEWITHDIMMERS.
Page: 3 of 3Page: 3 of 3
HyLiteLED“TypeA”Plug-inLampsandBulbs Ballast Compatible List
Compatible Not Compatible
Ballast Model120V 277V 120V 277V
Advance ICF-2S26-M1-BSAdvance ICF-2S26-H1-LDAdvance ICF-2S13-H1-LDAdvance ICF-2S18-H1-LDAdvance ICF-2S18-M1-BSAdvance IZT-2S26-M5-LDAdvance ICF-2S26-M1-BS-QSGE Proline GEC226-MVPS-BESGE Proline GEC226-MVPS-3WGE Proline GEC226-MVPS-SEGE GEC218-MVPS-3WGE GEC218-MVPS-BESGE GEC213-MVPS-3WHatch HC213PS/UV/DHatch HC226PS/UV/DHoward EP2/18CF/MV/2Howard EP2/26CF/MV/2LumaPro 4KGJ7LumaPro 16X954LumaPro 16X959LumaPro 4KGJ8Robertson PSM226CQMVDWCESylvania QTP 2x26CF/UNV S PEMSylvania QTP 2X26CF/UNV DMSylvania QTP 1/2x18CF UNV DMTriad C2642UNVSETriad C2642UNVMETriad C218UNVME
One Lamp Two Lamp
©2017-2020HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 022820
Not Suitable for
Enclosed Fixtures
TheListbelowisbasedinpartoninformationprovidedbytheBallastManufacturerandTestingwasdoneonastableACPowerSupplyunderLaboratory Conditions, which may or may not be representative of your particular End-use Conditions. HyLiteLED10W“TypeA”Plug-inLamps are only Dimmable if used with Dimmable Electronic Ballasts. It is the user’s responsibilitytocheckandverifywhethertheElectronicBallast isDimmable or Non-Dimmable.
ApplicationsandConditionsofusearemanyandvariedandbeyondourcontrol,sopurchasersandusersshouldmaketheirowndeterminationsas to the suitability of a Lamp-Ballast combination for their own particular Application and Use. Compatibility may also extend to Ballasts beyond thislist,soperforminganOn-SiteTestbeforeInstallationisStronglyRecommended.FailuretoFollowInstructionswillVOIDWarranty.
HyLiteHyLiteLED“TypeA”Plug-inLampsandOmni-BulbshavebeentestedforcompatibilitytoworkflawlesslywiththeBallastsshownabove.HyLiteiscontinuallytesting“TypeA”Plug-inLampsandOmni-BulbsonvariousotherBallasts.WewillcontinuetoupdatetheBallastCompatibilityListasadditionalmodelsaretested.PleasecontactHyLiteaboutanyBallastsnotshown on this list.
Note:RiskofFireorElectricShock.BeforeInstallation,checkSpecificationsforthemostCurrentBallastCompatibilityList.IftheBallastmodeldoesnotappearonthisList,pleaseDONOTInstall,untilyoucheckwithHyLite.InstalllingHyLiteLED“TypeA”Plug-inLampsandOmni-BulbswithoutverifyingitagainsttheBallastCompatibleListandwithouttestingtheCompatibilitywill void all Warranties. It is the user’s responsibilitytocheckandverifywhethertheElectronicBallastisDimmableorNon-Dimmable.ReadandUnderstandallInstallationInstructionsbeforeinstallingHyLiteLED“TypeA”Plug-inLampsandOmni-Bulbs.