Steve Coyne Light Naturally 6 June 2011, Sydney
LED Testing - methods
![Page 2: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/2.jpg)
CIE
CIE 84:1989 The measurement of luminous flux
CIE 177:2007 Colour Rendering of White LED Light Sources
CIE 127-2007 Measurement of LEDs
![Page 3: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/3.jpg)
Published • LM-79-08 Electrical and Photometric Measurement of SSL Products • LM-80-08 Measuring Lumen Maintenance of LED Light Sources • RP-16-10 Terminology on light emitting diodes added
Under development • TM-21 Projecting Long Term Lumen Maintenance of LED Light Sources • LM-82 Characterization of LED Light Engines and Integrated LED Lamps as
a Function of Temperature • LM-xx Photometric Measurements of High Power LEDs (Ohno, WG chair) • LM-xx Measurement of Lumen maintenance of LED lamps, light engines, and
LED luminaires.
Discussing • Revision of LM-79, LM-80 • Measurement of AC-driven h.p. LEDs • Measurement of waveforms of SSL products
IESNA Standards Activities on LED/SSL
![Page 4: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/4.jpg)
Purpose of Test Methods
Create a level playing field Allow manufacturers to specify performance of
products Provide information for designers and consumers Allow benchmarking of product categories for
regulation Allow compliance check testing
![Page 5: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/5.jpg)
Energy Efficient Lighting Products
For lighting products the key parameters for energy efficiency are:
total flux and luminous efficacy
![Page 6: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/6.jpg)
Total Flux measurement
2 fundamental methods/equipment Goniophotometry Integrating Sphere
![Page 7: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/7.jpg)
Comparison (relative)
Goniophotometer Expensive Slow Traditionally for
directional and non directional lamps
Integrating Sphere Inexpensive Fast Traditionally for non
directional lamps
![Page 8: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/8.jpg)
Cost of equipment and test procedure
Goniophotometer
Asset: ~ AUD $1M
Test: ~ AUD $1,000 per lamp
Integrating Sphere
Asset: ~ AUD $50,000
Test: ~ AUD $100 per lamp
![Page 9: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/9.jpg)
Compliance check testing
Prefer the less expensive Integrating Sphere test method if accurate with acceptable precision for directional and non-directional lamps.
From cost perspective, this allows for a greater market surveillance in order to protect the consumer and the suppliers
![Page 10: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/10.jpg)
Goniophotometry - explained
![Page 11: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/11.jpg)
Goniophotometry - explained
Measure light intensity in many directions Determine the total amount of light using 3 D
geometry and interpolation Accuracy of the result is determined by the number
of measurement points taken
![Page 12: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/12.jpg)
Goniophotometry - Accuracy
Example lamp 12 planes measured 558 lumens calculated
![Page 13: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/13.jpg)
Goniophotometry - Accuracy
Measuring only half of one plane
![Page 14: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/14.jpg)
Goniophotometry - Accuracy
Measuring 2 full planes
![Page 15: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/15.jpg)
Goniophotometry – Multi source LED
Becomes problematic for multiple source LED products
The interpolation between points becomes risky
![Page 16: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/16.jpg)
Integrating Sphere
All light from the lamp is captured within the sphere
The light measured by a detector is proportional to the total amount of light emitted by the lamp
No information about light distribution is obtained
![Page 17: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/17.jpg)
Integrating Sphere - CIE method
CIE84 Externally ported test for
strongly directional lamps
![Page 18: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/18.jpg)
Integrating Sphere - CIE method
Issues with lamp size and shape with the port
![Page 19: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/19.jpg)
Integrating Sphere – IESNA method
Internally mounted lamp Directed down to base of
sphere
![Page 20: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/20.jpg)
Integrating Sphere – IESNA method
Potential issue with narrow beam lamp to base of sphere where dirt and dust collects
![Page 21: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/21.jpg)
Research into preferred test lamp orientation in Sphere
The test lamp orientations investigated were Externally ported test lamp (at Auxiliary port) Centrally located and facing:
towards the auxiliary lamp (ie away from baffle) vertically down towards the baffle in (ie horizontally and away from sphere opening) out (ie horizontally and towards sphere opening)
![Page 22: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/22.jpg)
Research into preferred test lamp orientation in Sphere
![Page 23: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/23.jpg)
Research into preferred test lamp orientation in Sphere
Comparison between different orientation results
![Page 24: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/24.jpg)
Research into preferred test lamp orientation in Sphere
Comparison between different orientation results
![Page 25: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/25.jpg)
Round Robin tests with industry
Round Robin of tests conducted on 90 lamps Participation by 6 laboratories (China, Europe,
Australia) Test method refined during Round Robin
![Page 26: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/26.jpg)
Round Robin tests with industry
Results – narrow beam
Lab A Lab B Lab C Lab D Lab E Lab E Gonio
![Page 27: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/27.jpg)
Round Robin tests with industry
Results – wide beam
Lab A Lab B Lab C Lab D 1:1 line Lab E Lab E Gonio
![Page 28: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/28.jpg)
Round Robin tests with industry
Conclusions to Round Robin Participants agreed that the test method could provide
accurate total flux measurements Documentation of the test method required some
refinement (incorporating technical issues highlighted during Round Robin)
![Page 29: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/29.jpg)
Tests on Directional LEDs
Tests were conducted on sample LED products using goniophotometer (many measurement points) and integrating sphere (method from Round Robin)
![Page 30: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/30.jpg)
LED Results
![Page 31: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/31.jpg)
LED Results
![Page 32: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/32.jpg)
LED Results
![Page 33: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/33.jpg)
LED Results
![Page 34: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/34.jpg)
LED Results
Comparing sphere reference lamp methods
![Page 35: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/35.jpg)
Summary
Test methods have different levels of accuracy and precision
Need methods which meet the needs of Manufacturers Designers and consumers Governments (benchmarking, compliance)
For lighting products key parameters for energy efficiency are total flux and luminous efficacy
![Page 36: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/36.jpg)
Suggested strategy for Gov’ts
Have availability of inexpensive test method (with acceptable measurement tolerance) for compliance check testing
Consider using more expensive test method (with smaller measurement tolerance) for products which have inconclusive check test results
![Page 37: LED Testing - methods - lites.asia CIE 84:1989 The measurement of luminous flux CIE 177:2007 Colour Rendering of White LED Light Sources CIE 127-2007 Measurement of LEDs](https://reader035.fdocuments.net/reader035/viewer/2022082209/5b095ef47f8b9a3d018d9d93/html5/thumbnails/37.jpg)
Caution
Need to give careful consideration to the implications on available test methods of any exotic performance measures