LED Lighting Fixturefiles.orionlighting.com/resources/PRODUCT/HARRIS/application... · rods go into...

3
Installation Guide Read and follow all safety instructions WARNING RISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK Electrical Requirements Prepare Electrical Wiring Grounding Instructions SAVE THESE INSTRUCTIONS BEFORE YOU BEGIN The LED driver must be suplied with 120 or 277V, 50/60 Hz and connected to an individual, properly grounded branch circuit protected by a 20 ampere circuit breaker. Use min. 75°C supply. The grounding and bonding of the overall system shall be done in accordance with NEC Article 600 and local codes LED Lighting Fixture This product should be installed, inspected, and maintained by a qualified electrician only, in accordance with the NEC (National Electric Code) and all local codes. Turn off electrical power before inspection, installation or removal. Use only UL (or other NTRL) approved wire for input/output connections. Minimum size 18 AWG or 14 AWG for continuous runs. Make sure LEDs and drivers are cool to touch when performing maintenance. Make sure the supply voltage is the same as the rated voltage of the luminaire. Do not install in a hazardous atmosphere, except where the ambient temperature does not exceed the rated operating temperature of the fixture. Keep tightly closed when in operation

Transcript of LED Lighting Fixturefiles.orionlighting.com/resources/PRODUCT/HARRIS/application... · rods go into...

Page 1: LED Lighting Fixturefiles.orionlighting.com/resources/PRODUCT/HARRIS/application... · rods go into channels in extrusion. Pass ends of threaded rods though holes in fixture mounting

Installation Guide

Read and follow all safety instructions

WARNINGRISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK

Electrical Requirements

Prepare Electrical Wiring

Grounding Instructions

SAVE THESE INSTRUCTIONS

BEFORE YOU BEGIN

The LED driver must be suplied with 120 or 277V, 50/60 Hz

and connected to an individual, properly grounded branch circuit

protected by a 20 ampere circuit breaker. Use min. 75°C supply.

The grounding and bonding of the overall system shall be

done in accordance with NEC Article 600 and local codes

LED Lighting Fixture

This product should be installed, inspected, and maintained by a qualified electrician only,in accordance with the NEC (National Electric Code) and all local codes.Turn off electrical power before inspection, installation or removal.Use only UL (or other NTRL) approved wire for input/output connections.Minimum size 18 AWG or 14 AWG for continuous runs.Make sure LEDs and drivers are cool to touch when performing maintenance.Make sure the supply voltage is the same as the rated voltage of the luminaire. Do not install in a hazardous atmosphere, except where the ambient temperature does not exceed the rated operating temperature of the fixture.Keep tightly closed when in operation

Page 2: LED Lighting Fixturefiles.orionlighting.com/resources/PRODUCT/HARRIS/application... · rods go into channels in extrusion. Pass ends of threaded rods though holes in fixture mounting

Tools Required:Socket Wrench1/2" Socket for Pole Mount9/16" Socket for FixtureWire StrippersWire CuttersDrill with Step bit and 3/8" bit

Figure 1.

Figure 3.

LED Lighting Fixture Installation Guide

Figure 2.

Ensure Breaker is switched off before startingUnpack fixture and ensure that there are no damaged parts.Use the included template for the drilling hole pattern for the Pole Mount. NOTE: These are just holes to pass the threaded rod they are not going to be tapped.Use the pole mount backing plate to secure the threaded rods to the pole. Remove fixture mounting compartment from fixture to continue installation.Attach cord grip to center hole in fixture mounting compartment. Make sure cord grip gasket is on outer surface of fixture mounting compartment.Pass approximately 6" of cord through the cord grip (toward the inside of the fixture mounting compartment). Tighten cord grip around cord.Pass the other end of the cord through the arm extrusion and into the pole through the center hole in the pole between the 2 threaded rods. Insert the threaded rods into the arm extrusion, making sure rods go into channels in extrusion.Pass ends of threaded rods though holes in fixture mounting compartment. Using the included Lock Washers and Nuts, tighten down the entire assembly to 11ft-lbs (132 in-lbs). Once the assembly has been tightened down ensure that the fixture lead wires are connected to the ends of the cord inside the fixture mounting compartment. connect black to black, white to white and green to green. Reattach the fixture mounting compartment. Tighten bolts to 19 ft-lbs (228 in-lbs)Make wiring connections within pole as seen in figure 3.

MS03132017

LED Area Light

Page 3: LED Lighting Fixturefiles.orionlighting.com/resources/PRODUCT/HARRIS/application... · rods go into channels in extrusion. Pass ends of threaded rods though holes in fixture mounting
Garett
Typewritten text
Interchangeable Optic Instructions 1) Remove four screws (A) from each optic bracket (B) 2) Remove optic bracket and top gasket (C) 3) Rotate optics (D) to desired position or replace optics with different style optics. 4) Ensure that bottom gasket (E) is properly seated with holes lined up with the screw holes in the fixture housing. 5)Place the top gasket over the optic and ensure the holes are aligned with the notches in the optic and the bottom gasket. 6) Replace optic bracket and secure with the original four screws. 7) Hand tighten the screws and repeat for each additional lens.
Garett
Typewritten text
A
Garett
Typewritten text
B
Garett
Typewritten text
C
Garett
Typewritten text
D
Garett
Typewritten text
E