بسم الله الرحمن الرحيمبسم الله الرحمن الرحيم
GENUS:LEGIONELLA
Prof. Khalifa Sifaw Ghenghesh
![Page 2: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/2.jpg)
Gram-negative rods Requires iron and cysteine for growth
– Buffered charcoal yeast-extract agar (BCYE)
Optimum growth temp. >> 35-36oC Grow better >> 2.5-5% CO2
39 species– Legionella pneumophila
![Page 3: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/3.jpg)
Legionella pneumophilaLegionella pneumophila
Divided into 3 subspecies– L. pneumophila ssp. pneumophila– L. pneumophila ssp. fraseri– L. pneumophila ssp. pascullei
L. pneumophila divided to >14 serogroups
Most infections caused by:– L. pneumophila, serogroup 1
(SG1)
![Page 4: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/4.jpg)
Legionella pneumophila (TEM)
Legionella pneumophila (TEM)
![Page 5: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/5.jpg)
CLINICAL SYNDROMESCLINICAL SYNDROMES
1. Legionnaires’ Disease– Pneumonia– Incubation period >> 2-10 days– High fever, respiratory distress,
cough, confusion and local neurological signs.
– Mortality10% in healthy individuals
![Page 6: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/6.jpg)
2. Pontiac Fever– A brief febrile influenza-like
illness– A high attack rate with no
mortality– Source of infection usually is
not identified
![Page 7: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/7.jpg)
Impression smear from the lung of a patient fatally infected with L. pneumophila
serogroup 1, demonstrating many thin, Gram-negative bacilli (arrows).
Impression smear from the lung of a patient fatally infected with L. pneumophila
serogroup 1, demonstrating many thin, Gram-negative bacilli (arrows).
![Page 8: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/8.jpg)
Lung cross-section of patient with L. pneumophila infection
Gram-negative, coccoid rods
Lung cross-section of patient with L. pneumophila infection
Gram-negative, coccoid rods
![Page 9: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/9.jpg)
![Page 10: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/10.jpg)
LABORATORY DIAGNOSISLABORATORY DIAGNOSIS
SPECIMENS– Sputum, bronchial aspirate or washings– Pleural fluid, lung biopsy or autopsy material >>
Microscopy examination CULTURE
– BCYE with or without antibiotics– Incubate for 48 hours at 36oC aerobically with 2.5% CO2
– Plates kept for least 10-14 days before discarded as negative
– Colonies >> “cut-glass” appearance by plate microscopy or fluorescing blue-white under UV light
IDENTIFICATION– Specific antisera in an immunofluorescence test.
![Page 11: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/11.jpg)
ANTIGEN TESTS– Urine for legionella antigen
by ELISA for identifying L. pneumophila SC1
SEROLOGY– Not reliable
![Page 12: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/12.jpg)
Charcoal-yeast extract agar plate culture of Legionella pneumophila.Charcoal-yeast extract agar plate culture of Legionella pneumophila.
![Page 13: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/13.jpg)
Charcoal-Yeast extract agar plate culture of Legionella pneumophilia - Circular off-
white colonies (day 6, at 36oC)
Charcoal-Yeast extract agar plate culture of Legionella pneumophilia - Circular off-
white colonies (day 6, at 36oC)
![Page 14: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/14.jpg)
L. pneumophila stained using direct FA technique (400x)
L. pneumophila stained using direct FA technique (400x)
![Page 15: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/15.jpg)
TREATMENTTREATMENT
Erythromycin in high dosage (IV)
Rifampicin, Ciprofloxacin
![Page 16: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/16.jpg)
EPIDEMIOLOGYEPIDEMIOLOGY Disease occurs in outbreak form due to
dissemination of the bacteria in aerosols Infected aerosols generated from warm water
sources:– Ponds of cooling towers of refrigeration
plants in air-conditioning systems– Domestic hot water systems in hotels and
hospitals– Warm water in nebulizers and oxygen line
humidifiers– Whirlpool spa baths and showers
![Page 17: Lecture 24 Legionella](https://reader035.fdocuments.net/reader035/viewer/2022062307/554b0f63b4c9055d098b4841/html5/thumbnails/17.jpg)
CONTROLCONTROL
Eradication of Legionella organisms in various kinds of water sources that may give rise to aerosol production.
Eradication by– Heat or disinfection with
chlorine or other biocides– Hot water should be above
60oC before distribution