LECTROCOUNT LCR-II CPU 840404 WIRING SCHEMATIC
OPTICAL AIR ANDVAPOR ELIMINATORS
81947Optical Sensor
502011S3 Solenoid Valve
Gnd/Black (54)In5/White (55) +VP/Red (52)
Out8/Black (53)
+VP/Red (56)
Out8/Black (53)
+VP/Red (52)
2
1S3
J15Terminal
TEM
PERA
TURE
PRO
BE
White (20)
White (21)Red (22)
Red (23)J14
Terminal
ETVC (Electronic Temperature Volume Compensation)
71130 Temperature Probe
J8Terminal
111213
PRINTER SERIAL 485 TERMINAL
POWER
COUNTER
MH1 CTS RXD TXD RTS GNDGND 485+A485-B CTS RXD TXD RTS +VP
EART
H
GND
GND
IN 1
IN 2
IN 3
IN 4
+5V
OUT
+VP
GND +12-
24V
MH4
J20
J6
J3J2J1
J7J7
C2
2425
+5V(Out)/Jumper (59 to 32)
B
DIFFERENTIAL PRESSURE (∆P) TRANSDUCER
J1Terminal
J3Terminal
82637∆P Transducer Kit
81944DP/Printer Board
Auxiliary Output 1 (Out 1)
Auxiliary Output 2 (Out 2)
Pulse Output (Out 3)
J12Terminal
AUXILIARY OUTPUTS
AUXILIARY DEVICE
i.e Dead-Man Shutdown
AuxiliaryDevice
J13Terminal
Out7+Vo
Power, input and output (I/O) wiring must be in accordance with the area classification for which it is used (Class I, Div 1). For North America, installations must be per the U. S. National Electrical Code, NFPA 70, or the Canadian Electrical Code in order to maintain Class I, Division 1 ratings. This may require using connections or other adaptations in accordance with the requirements of the authority having jurisdiction.
WARNING: Explosion Hazard - Substitution of components may impair suitability for Class I, Division 1 applications.
WARNING: Explosion Hazard - When in hazardous locations, turn power OFF before replacing or wiring modules.
WARNING: Explosion Hazard - Do NOT disconnect equipment unless power has been switched OFF or the area is known to be Non-Hazardous.
For positive ground installation, contact the Liquid Controls Service Department
GN
D/B
lack
(41
)D
N/G
reen
(40
)
+Vo
/Red
(45
)
UP/
Whi
te (3
9)
LECTROCOUNTREMOTE DISPLAY
J12Terminal
81816Remote Display Cable
INTERNALPULSER(or POD 5)
DMS i1000
J1Terminal
J2Terminal
J3Terminal
81513040Black Data Cable 40’
Violet and red wires move from
48 & 46 to 25 & 24
+V
P/Red (24)TX
D/V
iolet (25)
RX
D/G
ray (49)C
TS/Green (50)
GN
D/W
hite (51)
GN
D/Black (30)
CTS/Blue (29)
RX
D/Yellow
(28)TX
D/O
range (27)RTS/Brow
n (26)
2425
SERIAL J2 TERMINAL J3PRINTER J1
J3 Terminalcan be
disconnected
PRINTER
+VP/Red (46)TXD/Violet (48)
RXD/Gray (49)
CTS/Green (50)GND/White (51)
GND/Black (30)
CTS/Blue (29)RXD/Yellow (28)
TXD/Orange (27)RTS/Brown (26)
J1Terminal
J3Terminal
81513040Black Data Cable 40’
81514Lap Pad Adapter
E40301Lap Pad
TERMINAL J3PRINTER J1
2425
825001Printer Power Cable
81838Membrane Switch
81839Membrane Switch Harness
J8Terminal
Blac
k (3
8)
Vio
let (
36)
Gre
y (3
5)
MEMBRANESWITCH
81915 LCR-II LCD Display
81832LCR-II Switch Harness
81819LCR-II Switch Plate
81330LCR-II Display Coiled Cable
J6
5253545556
PRINTER SERIAL 485 TERMINAL
POWER
COUNTER
MH1 CTS RXD TXD RTS GNDGND 485+A485-B CTS RXD TXD RTS +VP
EART
H
AUX OUTPUTS
PULSE INPUTS
AUX I/O
GND
GND
GND
IN 1
OUT
1
OUT
2
OUT
3
TEMPERATURE PROBE
ASSY84040 REV.
RTD+
S
RTD-
D1
RTE-
S
RTD+
D
OUT
4
OUT
5
IN 2
IN 3
IN 4
+5V
OUT
+VP
+VP
PGND
OUT
6
+VP
SOL
+VPPGNDOUT7
+VF+VFIN5 OUT8GND
GND +12-
24V
MH4
C1
J20
J3J2J1
J7
J12
J15
P1
TP1
J5
J14
J18
J19
J10J17
J11 J7
C2
MH5
MH3
MH2
AB
2425
111213
J1Terminal
J2Terminal
J3Terminal
J6Terminal
J8Terminal
J12Terminal
J15Terminal
J13Terminal
J14Terminal
CPU 84040
J10 Communications JumperLCR-II - In A position for Lap Pad all other functions in B position
POWER
EARTH/Shield (13)
GN
D/Black (12)
111213
+12-24/Red (11)
Open Drain
Battery orAccessory Panel
GROUNDDC Power
SupplyPowerSupply
81512 40' Gray
Power Cable
7.5AIn-LineFuse
E3655/E3656
SOLENOID VALVES
J13Terminal
Jumper fromTerminal 15
to Terminal 18
Earth/Green (16)Out7/Black (15)
+12V/Black (14)
S1&2
J13Terminal
Earth/Green (16)
Earth/Green (19)Out7/Black (15)Out6/Black (18)
+12V/Black (14)
+12V/Black (17)
Earth/Green (19)
Out6/Black (18)
+12V/Black (17)
2
1Earth/Green (16)
Out7/Black (15)
+12V/Black (14)
2
1
Two Stage
81527 3-Way Solenoid (LPG)A2859-11 Block Valve (LPG)
A2848-11 Two Stage Block Valve
A2982 E-7 Two Stage Piston Valve
Single Stage
81527 3-Way Solenoid (LPG)A2843 Block Valve (LPG)
A2847-11 Single Stage Block Valve
Solenoid operated valve 81527 (3-way LPG solenoid) has 3 cablespotted into the housing. All other solenoid operated valves on LiquidControls valves use cable assembly81859, which has 2 cables.
The Earth grounds for Terminals 16& 19 are optional. The solenoid operated valves are grounded through the component they aremounted on.
ESD PRECAUTION OPENING LECTROCOUNT REGISTERSBefore opening the LectroCount register and handling the CPU board, it is important to discharge any ESD that may have built up on your person. To discharge ESD from your person, touch a well-grounded point such as the LectroCount register housing, the meter, the truck piping, or the bumper. When the maintenance is complete and the LectroCount register door is closed, the CPU board is protected from ESD by the LectroCount register housing which is grounded to the chassis.
SOLJ13
SOLJ13
SOLJ13
AUX I/OJ15
AUX OUTPUTS J12
AUX OUTPUTS J12
POWER J6
PULSE OUTPUTS J8
A/Blue (58)+5V/Red (59)
B/Yellow (57)GND/White (51)+VP/Black (46)
PULSE OUTPUTDEVICE (POD) 1-4
GN
D/B
lack
(37
)
CH
B/G
reen
(34
)C
HA
/Whi
te (
33)
+Vo
/Red
(31
)
J8Terminal
PULSE OUTPUTS J8
GN
D/B
lack
(37
)
CH
B/G
reen
(34
)C
HA
/Whi
te (
33)
+5/
Red
(32)
J8Terminal
82597Internal Pulser Kit
PULSE OUTPUTS J8