Leader in Ultrasonic Humidification. HUMIDIFIRSTS HISTORY Designing and prototyping of Ultrasonic...
-
Upload
ashton-richards -
Category
Documents
-
view
221 -
download
2
Transcript of Leader in Ultrasonic Humidification. HUMIDIFIRSTS HISTORY Designing and prototyping of Ultrasonic...
Leader in Ultrasonic HumidificationLeader in Ultrasonic Humidification
HUMIDIFIRST’S HISTORYHUMIDIFIRST’S HISTORY
Designing and prototyping of Ultrasonic Humidifiers Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PAbegins in 1992 in Harrisburg, PA
First patent applied for in 1993First patent applied for in 1993 Shipped first equipment in 1994 to Boeing Co.Shipped first equipment in 1994 to Boeing Co. Second patent applied for in 1994Second patent applied for in 1994 Manufacturing begins in Burlington, NC in 1994Manufacturing begins in Burlington, NC in 1994 All manufacturing and R&D moved to Boynton All manufacturing and R&D moved to Boynton
Beach, FL in 2000Beach, FL in 2000
Designing and prototyping of Ultrasonic Humidifiers Designing and prototyping of Ultrasonic Humidifiers begins in 1992 in Harrisburg, PAbegins in 1992 in Harrisburg, PA
First patent applied for in 1993First patent applied for in 1993 Shipped first equipment in 1994 to Boeing Co.Shipped first equipment in 1994 to Boeing Co. Second patent applied for in 1994Second patent applied for in 1994 Manufacturing begins in Burlington, NC in 1994Manufacturing begins in Burlington, NC in 1994 All manufacturing and R&D moved to Boynton All manufacturing and R&D moved to Boynton
Beach, FL in 2000Beach, FL in 2000
Data Room HumidificationData Room Humidification
ASHRAEASHRAESets the Standards for the
Recommended Data Room Operating Environment
-Temperature-Humidity
Reason?
-To Reduce the Risk of ESD (Electrostatic Discharge)-ESD can damage electrical equipment
-ESD can cause errors in operation & readings
Sets the Standards for the Recommended Data Room Operating Environment
-Temperature
-Humidity
Reason?
-To Reduce the Risk of ESD (Electrostatic Discharge)-ESD can damage electrical equipment
-ESD can cause errors in operation & readings
ASHRAEASHRAE2004
Recommended Data Room Operating Environment
-Temperature = Low End at 68º F (20º C) High End at 77º F (25º C)
-Humidity = Low End at 40% RH High End at 55% RH
2004Recommended Data Room Operating Environment
-Temperature = Low End at 68º F (20º C) High End at 77º F (25º C)
-Humidity = Low End at 40% RH High End at 55% RH
2004 ASHRAE Psychrometric Chart2004 ASHRAE Psychrometric Chart
68F 40%RH
77F 55%RH
ASHRAEASHRAE2008
Recommended Data Room Operating Environment
-Temperature = Low End at 64.4º F (18º C) not 68F High End at 80.6º F (27º C) not 77F
-Humidity = Low End “Dew Point” 41.9º F DP (5.5º C)
High End “Dew Point” 59º F DP (15º C) But < 60% RH
2008Recommended Data Room Operating Environment
-Temperature = Low End at 64.4º F (18º C) not 68F High End at 80.6º F (27º C) not 77F
-Humidity = Low End “Dew Point” 41.9º F DP (5.5º C)
High End “Dew Point” 59º F DP (15º C) But < 60% RH
Why Use Dew Point for Moisture Control?
Why Use Dew Point for Moisture Control?
Studies show ESD is function of:
-“Absolute Humidity” in Air,
Not “Relative Humidity” of Air
Studies show ESD is function of:
-“Absolute Humidity” in Air,
Not “Relative Humidity” of Air
2008 ASHRAE Psychrometric Chart2008 ASHRAE Psychrometric Chart
High End Temperature is increased by 3.6º FLow End RH is decreased to < 30% RH at 80º F
64.4F to 80.6F at 41.9DP to 59DP
68F 77F
Result ?Result ?
ENERGY SAVINGS!
Data Rooms can operate at:
- Higher Temperatures - Lower RH Levels
This Encourages Economizer Cooling
ENERGY SAVINGS!
Data Rooms can operate at:
- Higher Temperatures - Lower RH Levels
This Encourages Economizer Cooling
How To Humidify Data Centers ?How To Humidify Data Centers ?
1. Central Humidification-AHU
-Ductwork
2. In-Room Humidification-In-CRAC
-Wall Mount-Free-Standing
1. Central Humidification-AHU
-Ductwork
2. In-Room Humidification-In-CRAC
-Wall Mount-Free-Standing
Central HumidificationAHU Mounted
Central HumidificationAHU Mounted
Central HumidificationDuct Mounted
Central HumidificationDuct Mounted
Problems with Central Humidifiers:
Problems with Central Humidifiers:
1. Economizer Means Outside Air -Cold Air -Wetting Risk -Control Issues -Location of Humidifier: -Harder to Service -Difficult to Monitor2. Direct Injection Steam- chemicals in air from
boiler (needs heat exchanger—adds cost)3. If Humidifier Must be Outside Data Room,
Corridor/Gallery is Preferable
1. Economizer Means Outside Air -Cold Air -Wetting Risk -Control Issues -Location of Humidifier: -Harder to Service -Difficult to Monitor2. Direct Injection Steam- chemicals in air from
boiler (needs heat exchanger—adds cost)3. If Humidifier Must be Outside Data Room,
Corridor/Gallery is Preferable
Corridor/GalleryCorridor/Gallery
In-Room HumidifiersIn-Room Humidifiers
In-CRAC Installation In-CRAC Installation
CRAC Installation PhotosCRAC Installation Photos
Problems with CRAC HumidifiersProblems with CRAC Humidifiers
-Cold Air
-Short Area for Evaporation
-Cold Air
-Short Area for Evaporation
In-Room HumidifiersIn-Room Humidifiers
1. Wall Mounted
2. Free Standing
1. Wall Mounted
2. Free Standing
Wall Mounted Mist-Pac SeriesWall Mounted Mist-Pac Series
Wall Mounted Mist-Pac SeriesWall Mounted Mist-Pac Series
Free Standing Mist-Free Series Free Standing Mist-Free Series
Free Standing Mist-Free SeriesFree Standing Mist-Free Series
Benefits of In-Room HumidificationBenefits of In-Room Humidification1. Direct Room Introduction of Moisture a) Higher Output Capacity
2. Better Control a) Sense Room Moisture without
Concern of High-Limit Saturation
b) More Accurate. Particularly with Individual Sensors
3. Easier to Service
4. Safety Overflow Control by Sensor and Drain Piping
1. Direct Room Introduction of Moisture a) Higher Output Capacity
2. Better Control a) Sense Room Moisture without
Concern of High-Limit Saturation
b) More Accurate. Particularly with Individual Sensors
3. Easier to Service
4. Safety Overflow Control by Sensor and Drain Piping
Mist-Free Series Drain and Safety Overflow Ready
Mist-Free Series Drain and Safety Overflow Ready
Mist-Pac Series Drain and Safety Overflow Ready
Mist-Pac Series Drain and Safety Overflow Ready