LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA...

27
May 06 2019 LBA-2000H EDFA User Manual

Transcript of LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA...

Page 1: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

May 06 2019

LBA-2000H

EDFA

User Manual

Page 2: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

ii

LBA-2000H Series

User Manual

TABLE OF CONTENTS

TABLE OF CONTENTS .............................................................................................................. ii

1.0 PRODUCT OVERVIEW & FEATURES ........................................................................ 1

1.1 Description .................................................................................................................... 1

1.2 Features ......................................................................................................................... 1

2.0 SAFETY NOTES ............................................................................................................... 2

3.0 LBA-2000H SERIES FRONT PANEL AND BACK PANEL LAYOUT ....................... 3

4.0 BLOCK DIAGRAM & TECHNICAL SPECIFICATIONS .......................................... 4

5.0 INSTALLATION ............................................................................................................... 6

5.1 Required Equipment & Tools ................................................................................... 6

5.2 Installation of EDFA .................................................................................................... 6

6.0 OPERATION AND MENU FUNCTIONS ...................................................................... 8

7.0 WEB MANAGEMENT & SNMP .................................................................................. 15

8.0 WARRANTY & RMA POLICY ..................................................................................... 23

Page 3: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

1 | P a g e

LBA-2000H Series

User Manual

1.0 PRODUCT OVERVIEW & FEATURES

1.1 Description

Lindsay Broadband’s LBA-2000H Series EDFA is a high-power Optical Amplifier, with touch

screen LCD. The LBA-2000H series comes in 4, 8, 16, 32 and 64 ports and is available in

output power range of 18dBm to 21dBm per port.

LBA-2000H is characterized by low noise and high linearity performance to meet the most

demanding requirements of CATV and FTTx applications. Well-designed ventilation and heat

dissipation ensure long life and reliable operation. Optional dual switching power supply

modules can be used for load sharing and redundancy. Powering can be 90 ~ 264VAC or -

48VDC. RJ45 Ethernet connection offers network management. The microprocessor software

monitors the laser working state and the Digital Panel touch screen LCD displays the operating

parameters, status and warning alarms. If at some point, the laser operating parameters deviate

from the permissible range set by the software, the microprocessor will automatically turn off the

laser power which offers protection for the laser. The LBA-2000H EDFA is compatible with any

FTTx PON Technology and offers a flexible and low-cost solution.

1.2 Features

• Multiple ports (4,8,16,32 and 64 ports), high output EDFA

• 19"standard rack mounted case

• Touch screen LCD on the front panel to monitor and set-up parameters

• 3 Optical Output Power control modes: APC, ACC or AGC

• Vary the output power of the EDFA according to your requirements

• High precision built in power meter to monitor input/output power and back reflections

• Auto output power shut off when input signal falls below threshold

• RJ45 Ethernet Port for Plug-in network management & SNMP

Page 4: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

2 | P a g e

LBA-2000H Series

User Manual

2.0 SAFETY NOTES

Warning Description Warning Description

The measured data is

greater than or lower than

the critical value

Optical output power

activated!

Laser Radiation!

The measured data

approaches the critical

value (greater or lower

than the warning value)

Optical output power is

shut down.

No Laser Radiation!

No warnings

• The EDFA employs a high-powered infrared laser device that emits invisible light, which can permanently damage eye or skin on exposure.

• Avoid direct exposure of eyes & skin to the laser light source. Never stare directly into a fiber or at any mirror-like surface that could reflect light emitted from an un-terminated fiber. Never view an active fiber through optical instruments.

• Always ground the EDFA before turning on power (grounding resistance

should be less than 4 ohms), so as to prevent laser and user from static damage.

• To avoid damaging the touchscreen LCD, please do not tap it with anything

sharp or apply excessive pressure to it with your fingertips. It is recommended to use fingers when you use the touch screen LCD.

• Always turn the EDFA OFF prior to connecting/disconnecting input fiber. Also always terminate unused ports. Failure to do so may result in damage to the EDFA.

NO SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Page 5: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

3 | P a g e

LBA-2000H Series

User Manual

3.0 LBA-2000H SERIES FRONT PANEL AND BACK PANEL LAYOUT

Figure 1: LBA-2000H series Front & Rear panel

No. Description No. Description

1 Color Touch Screen LCD 8 Handle

2 RJ-45 LAN Port for Management 9 Cooling Fan

3 LCD Display RESET1 10 Hot Pluggable Power 1: AC Input

4 System RESET2 11 Hot Pluggable Power 2: DC Input

5 Optical Test Port 12 Grounding Screw

6 Optical Input Port 13 Cooling Fan

7 Optical Output Ports 14 Cooling Fan

Page 6: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

4 | P a g e

LBA-2000H Series

User Manual

4.0 BLOCK DIAGRAM & TECHNICAL SPECIFICATIONS

Figure 2: LBA-2000H series Block Diagram

Optical Characteristics

Parameter Unit Value

Optical Input Wavelength nm 1545 ~ 1565

Optical Input Power dBm -10~+10

Output Optical Power dBm 18 to 21

Typical Output Power dBm 18 to 21; See Ordering Information

Output Power Stabilization Range % 30 ~100

Port Numbers -- 4, 8, 16, 32 or 64; See Ordering Information

Output Power Tolerance dB ± 0.5

Port Uniformity dB ± 0.7

Noise Figure (see Note 1) dB ≤ 5.5

Optical Test Port dB -5~+5

Return Loss Input / Output dB ≥ 45

Isolation Output ► Input dB ≥ 40

Polarization Dependence dB ≤ 0.3

Note1: Noise figure at 0 dBm input power, nominal output power and signal wavelength 1550 nm.

Page 7: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

5 | P a g e

LBA-2000H Series

User Manual

General Characteristics

Power Supply pcs 2 (1 default, 1 optional)

Chassis Type -- 1U, 2U, 19’’ Rack Mounted

AC Input Voltage Vac 90~264

DC Input Voltage Vdc 36~ 72

Power Consumption (maximum) W ≤75

Dimension (W x H x D) mm 484*44*385 (1U)

mm 484*88*336 or 484*88*416 (2U)

Operating Temperature Range °C -5~+45

Control Mode

Stabilization Mode

Pump Current

Output Optical Power

Optical Gain

Automatic Pump Shutdown Mode

Low Input Power (LOS)

High Back Reflection

Overheating

Management Interface

Data Link Layer Ethernet 10/100 Base-T and LLDP

Network Layer IPv4, ICMP

Transport Layer UDP, TCP

Application Layer SNMPv1/v2c, DHCP, Web

Connectors 10/100 Base-T

Front Panel Management 3.5” 480 x 320 Color Touch Screen LCD for 2U and 3U

2.4” 320 x 240 Color Touch Screen LCD for 1U

Page 8: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

6 | P a g e

LBA-2000H Series

User Manual

5.0 INSTALLATION

5.1 Required Equipment & Tools

• Optical power meter

• Standard fiber test jumpers

• Denatured or 99% pure isopropyl alcohol and lint free fiber optic cleaning wipes

5.2 Installation of EDFA

1) Uninterrupted power supply (UPS) and an air-conditioned environment are highly

recommended for stable and long-time EDFA operation.

2) Install the EDFA in the 19” rack. Leave 1RU of space between the EDFA and other

equipment installed in the rack for proper heat dissipation. Make sure the air vents on

the bottom of the EDFA are not blocked.

3) Ensure the LBA-2000H EDFA is grounded and is mounted in a properly grounded rack,

grounding resistance should be smaller than 4Ω. Always ground the EDFA before turning

on power, so as to prevent pump, laser and user from static damage.

4) Terminate the output ports of the EDFA to prevent damage to the laser when not

connected to the system.

5) Ensure optical jumper connectors are matched properly to the device adapters. (ie.

SC/APC to SC/APC).

6) Carefully clean all the fiber optic connectors. The suggested way to clean a fiber optic

connector is to use a dedicated and dry cloth (Kimwipes ®’s fine cloth).

7) A microscope (at 100 times, 200 times) can be used to check the cleanliness of fiber

optic connector surface from any contamination or blemish.

8) Clean the EDFA connector before installing the optical test cable. 2.5 mm cleaning

swabs are available. Clean both the bulkhead and fiber connectors.

9) Measure the input optical power to the EDFA. Verify the Input optical power is in the

range of -10dBm to +10dBm. Use an optical power meter to verify that the optical input

level is within the specification. However, the Recommended Input Level to the EDFA

Page 9: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

7 | P a g e

LBA-2000H Series

User Manual

is 0 dBm.

10) You can now connect the Optical fiber to the OPT IN connector on the Front panel. Also

connect the optical fiber(s) to the appropriate OPT OUT(s) connection. Terminate the

unused output ports with an Optical Terminator to prevent any reflections.

11) Turn ON the EDFA.

Note: Always turn the EDFA OFF prior to connecting/disconnecting input fiber. Also always terminate unused ports. Failure to do so may result in damage to the EDFA.

12) Check the LCD display & verify that the System Initialization is in process. (see figure 3)

13) Use the Optical Power meter to verify the output Optical power meets the specification.

14) There is also an Optical Test Point on the front panel of the EDFA. Its output power is -5

to +5 dBm. You can verify the EDFA amplification at the Optical test point.

Warning signs are displayed on the Touch Screen LCD interface. They are explained below.

These signs can be helpful when installing and setting up the EDFA.

Warning Description Warning Description

The measured data is

greater than or lower than

the critical value

Optical output power

activated!

Laser Radiation!

The measured data

approaches the critical

value (greater or lower

than the warning value)

Optical output power is

shut down.

No Laser Radiation!

No warnings

Page 10: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

8 | P a g e

LBA-2000H Series

User Manual

6.0 OPERATION AND MENU FUNCTIONS

When the EDFA is first powered ON, the touch screen LCD display will report the current EDFA

condition. See Figure 3.

Figure 3: System Initialization & Home Screen

1) Main Menu or Home Screen:

The main menu or home screen is displayed as shown in the right image of figure 3.

Item Description Unit

Input Power Displays the optical power of input signal dBm

Amplifier Mode The operating control mode: APC, ACC or AGC

Current Shows the Bias current of the pump %

Port Output Power Displays the Optical Output Power per port dBm

Temperature Shows the internal Temperature of the equipment °C

Back Reflection Shows the Back reflected Optical Power dBm

Link Up / Down Shows LAN management link between EDFA and Computer

EDFA Up time Bottom right corner of screen EDFA Up time after Power ON Hours & minutes

LBA-2000H has built-in power meter to monitor & display the optical power to the user interface

with ±0.2dB accuracy. Detector automatically calibrates the optical power on the EDFA via the

microcontroller (MCU). When input power is greater/lower than the input power range or high

level of back reflections or if EDFA is overheating, the LBA-2000H will turn OFF the pump

current (0%) & shut down the optical output of the EDFA. Also Default factory setting for

Amplifier mode is APC mode.

Page 11: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

9 | P a g e

LBA-2000H Series

User Manual

Located vertically on the right side of the touch screen graphic display are the main menus

Setup, Network and About. You can select any menu by finger touch.

Main Menu Description

Setup Selects amplifier control mode and sets the operating parameters.

Network View and/or set the network parameters of LBA-2000H

About Primary Information about the device

The home screen also shows the warning signs as explained in previous “Installation” section.

2) Setup Menu:

This menu appears when user taps the “Setup” on the main menu. It is to select the operation

control mode of LBA-2000H and set the values of the relevant parameters. See Figure 4. Press

the “Back” button to return to the main menu/home screen.

Figure 4: Setup Menu

Operating modes are displayed on the LCD screen in setup menu.

Control Mode Description User Level

APC (Automatic Power Control)

Output Optical Power Level Stabilization

Basic User (Default & Recommended mode)

ACC (Automatic Current Control)

Pump Current Level Stabilization Professional Only

AGC (Automatic Gain Control)

Optical Gain Level Stabilization Professional Only

Turn Off Pump Turns Off the Current of Pump Laser Basic User

Page 12: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

10 | P a g e

LBA-2000H Series

User Manual

Figure 5: Enter PIN when setting parameters

Note: When entering or changing any settings on the LBA-2000H EDFA, it will ask to enter “PIN”. The

EDFA asks the user to enter PIN in order to avoid false touch and to prevent unauthorized users. See

Figure 5. Input PIN code and press “Save” to proceed. The default PIN code is “1111”, also labelled on top

of the EDFA. The default PIN authorization timeout is 5 minutes. If the user does not touch the screen

over 5 minutes, it asks for a PIN again. User can also go to Web Management to change PIN code and

PIN authorization timeout.

Button Description Button Description

Tap to return to the previous

screen menu without saving

Clear up one number

Allows to clear all input field

Saves specified parameter/

value/ mode to apply

APC Mode (recommended): On the Setup menu page touch “APC” to enter APC mode.

Automatic Power Control (APC) mode sets the Optical Output to your requirement. Shown in

Figure 6. The set output power is maintained regardless of the variation in input power or pump

current or temperature. The EDFA automatically adjusts the pump current to ensure stable

desired output power. However, the user cannot exceed the minimum and maximum output

power specifications of the EDFA.

Using the numeric keypad, enter the value you want to set the Output Power at and hit save.

Page 13: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

11 | P a g e

LBA-2000H Series

User Manual

Figure 6: Using APC mode

ACC Mode: On the Setup menu page touch “ACC” to enter ACC mode. See Figure 7.

Automatic Current Control (ACC) mode provides direct control to the amplification by managing

the pump current of the EDFA. The pump current stays stable irrespective of input power. The

pump current is set as a percentage (%) of the maximum value from the factory. By default, this

value is 80/80%. However, the output power cannot exceed the Critical Minimum and Maximum

specs of the EDFA. Using the numeric keypad enter the desired Pump Current value & save.

Figure 7: Using ACC Mode

AGC Mode: On the Setup menu page touch “AGC” to enter AGC mode. Shown in Figure 8.

Automatic Gain Control (AGC) mode establishes and maintains the gain of the signal regardless

of the input signal or temperature. The EDFA automatically adjusts the pump current according

to input power to maintain the required gain. However, the output power and pump current

cannot exceed its minimum and maximum rating to maintain gain. For example, the gain of

EDFA is set to 20dB, and then giving the EDFA -10 dBm input power results in output power of

Page 14: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

12 | P a g e

LBA-2000H Series

User Manual

+10 dBm. Similarly for the same 20dB gain setting, giving the EDFA 0 dBm input power results

in +20 dBm output power. Using numeric keypad enter the value of gain and hit save.

Figure 8: Using AGC mode

3) Network Config Menu:

This menu appears when you tap on “Network” from the main menu and it is designed to control

and configure the network parameters of LBA-2000H EDFA. See figure 9.

Figure 9: Network Parameters

Factory default configuration is as shown next. The network configuration can also be modified

by Web Management.

Item Default value

DHCP OFF

IP Address 192.168.1.1

Subnet Mask 255.255.255.0

Default Gateway 0.0.0.0

Page 15: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

13 | P a g e

LBA-2000H Series

User Manual

DHCP On/Off: DHCP is switched ON or OFF by pressing the DHCP button in this Network

Config menu. See figure 10.

Figure 10: DHCP on/off

IP Address: Tap the “IP address” button under Network Config menu to enter to change the IP

address. Using Keypad, enter the IP address and hit save. See Figure 11.

Figure 11: Set IP Address

Subnet Mask: Tap the “Subnet Mask” button under Network Config menu to enter Subnet

Mask. Enter the subnet mask using numeric keypad and hit save. See Figure 12.

Page 16: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

14 | P a g e

LBA-2000H Series

User Manual

Figure 12: Set Subnet Mask

Gateway: Set the default gateway address by tapping “Default Gateway” button under the

Network Config menu (Figure 13). Enter default gateway using numeric keypad and hit save.

Figure 13: Set Default Gateway

4) About: Tap “About” on the main menu to see the basic information about the device and

press “Back” to go to the main menu. See Figure 14.

Figure 14: About screen

Page 17: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

15 | P a g e

LBA-2000H Series

User Manual

7.0 WEB MANAGEMENT & SNMP

RJ-45 LAN port can be used to monitor and control the LBA-2000H parameters and adjust

output levels.

Connect the EDFA with a network cable to the PC RJ45 interface.

Factory network parameters of the EDFA can be found from the menu functions on the front

panel LCD. The parameters can also be found on a label on top of the EDFA equipment. Set

your PC IP address in the same network range.

IP: 192.168.1.1 Mask: 255.255.255.0 Gateway: 0.0.0.0

Open a Web Browser. In the address bar enter 192.168.1.1, Press Enter, the login screen will

display as shown in Figure 15. The default credentials are as below:

Username: Admin Password: PassAdmin

Figure 15: Login Screen

After logging into the EDFA the home screen of the Web GUI is as shown in Figure 16. The

navigation menu is to the left of the page. Click on the required menu. The EDFA content is

displayed for the corresponding menu chosen.

Page 18: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

16 | P a g e

LBA-2000H Series

User Manual

Figure 16: LBA-2000H General or Home Screen

Menu Sub Menu Description

Management General, Setup, Information and

Thresholds

Selects operation control modes of LBA-2000H

and sets the operating parameters

Network IPv4 address, SNMP, Time server View and/or set the network settings of EDFA

Security Web Password, Touchscreen Change the authorization parameters of EDFA

Service Firmware Update Upgrade the system firmware of the device

Logout To logout of the LBA-2000H device Web GUI

The setup page is as shown in Figure 17. Can set operating modes and parameters on this

page.

Page 19: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

17 | P a g e

LBA-2000H Series

User Manual

Figure 17: Setup Menu

The Information page is as shown below in Figure 18. Displays basic device info.

Figure 18: Information Menu

Page 20: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

18 | P a g e

LBA-2000H Series

User Manual

Threshold page is shown in Figure 19. The user can change the critical and warning parameters

of the EDFA according to the requirements. However, the main parameters of the EDFA like

Input Power range, Output power, etc. cannot be changed. These thresholds are just to

generate an alarm on the interfaces. On this page “C” would mean critical warnings and “W”

would mean warnings.

Figure 19: Thresholds Menu

Figure 20, 21 & 22 show the Network Parameters settings of the EDFA.

Figure 20: IPv4 Address - Network Menu

Page 21: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

19 | P a g e

LBA-2000H Series

User Manual

Figure 21: SNMP - Network Menu

Figure 22: Time Server - Network Menu

The security page on the Web management is used to change the authorization settings of the

EDFA.

On the Web Password section user can change the credentials for log in to the EDFA via web

management.

On the Touch Screen section user can change the touch screen PIN code, the Pin Code

Authorization Time out, and the back light settings of the EDFA. Their screenshots are as shown

in Figure 23 & 24.

Page 22: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

20 | P a g e

LBA-2000H Series

User Manual

Figure 23: Change Password - Security Parameters

Figure 24: Touch Screen settings - Security Parameters

The Service page is mainly for upgrading the firmware of the EDFA. Lindsay Broadband Inc. will

supply with an upgraded firmware whenever available.

Figure 25 & 26 show screen shots of the firmware upgrade process.

Page 23: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

21 | P a g e

LBA-2000H Series

User Manual

Figure 25: Firmware Upgrade - Service Menu

Figure 26: Ethernet Bootloader for Firmware upgrade

Page 24: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

22 | P a g e

LBA-2000H Series

User Manual

SNMP

LBA-2000H offers MIB for different network requirements. Use a MIB browser to configure

network information. The screen shot from a MIB browser is as shown in Figure 27.

Figure 27: MIB Browser

Page 25: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

23 | P a g e

LBA-2000H Series

User Manual

8.0 WARRANTY & RMA POLICY

Page 26: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

24 | P a g e

LBA-2000H Series

User Manual

Lindsay Broadband Return Material Authorization Policy

Send your returns to:

Lindsay Broadband Inc.

2-2035 Fisher Dr.

Peterborough, ON Canada K9J 6X6

Attn: Product Returns

All shipments are to be pre-paid by the sender. No COD’s will be accepted.

A Return Material Authorization (RMA) Number is required on all product returns (Regardless if Product is Being Returned to Repair or credit)

Product Received at the Lindsay Broadband Factory Without an RMA Number will be returned to Sender

RMA number must be used when returning product for credit or repair. Use of RMA numbers will ensure efficient processing. When returning product to Lindsay Broadband, please follow the simple steps below (in the order that they appear):

RETURNS

1. Fill out the Product Return Authorization Form indicating product information. Repair items do not require original invoice information, but it is helpful to determine warranty eligibility.

2. Contact Lindsay Broadband Inc. Service Department in one of three ways:

• E-mail to: [email protected] (recommended method) Include all of the information from the product Authorization Form, or,

• Fax the Product Authorization Form to 1-705-742-7669 or,

• Call Lindsay Broadband Inc. @ 800-465-7046 Ext 235 / 261 3. After completing Steps 1 & 2, an RMA number will be assigned to you. 4. Securely pack the product and mark the box with your RMA #. If shipping multiple boxes, all boxes should be marked with

the RMA #. The RMA # must be placed near your return address in large, bold print (approximately 2” in height). Please see the address label below as an example of the relative size location of the RMA #.

Sample Address label with RMA #

John Smith

ABC Company RMA 1234

123 Smith Street

Anytown, USA 00000

Lindsay Broadband Inc

2-2035 Fisher Dr.,

Peterborough, ON K9J 6X6

Attn: PRODUCT RETURNS

Page 27: LBA 2000H EDFA - lindsaybb.com Manual_May 06 2019.pdf · recommended for stable and long-time EDFA operation. 2) Install the EDFA in the 19” rack. Leave 1RU of space between the

2-2035 Fisher Dr., Peterborough, ON CANADA K9J 6X6 Ph: (705) 742-1350 or (800) 465-7046 Email: [email protected]

25 | P a g e

LBA-2000H Series

User Manual

Lindsay Broadband Return Material Authorization (RMA) Form

Company Contact Name:

Address: City:

Prov/State: Postal Code/Zip:

Phone: #: Fax #:

Email address (if applicable)

RMA # (To be supplied by Lindsay Broadband)

Date: ___________

Reason for return

Qty. LBI Part # Description P.O. # P.O.

Date

Service Repair Policy

Lindsay Broadband product may be

returned for repair under the following condition:

1. Please contact Lindsay Broadband

Service Dept. to obtain an RMA#. 2. Please supply requested

information to verify 2warranty

coverage.

Any shipments received by Lindsay

Broadband without an RMA # will be refused.

Credit Return Policy

Lindsay Broadband products may be retuned for credit under the following

conditions:

1. Products are unused and undamaged.

2. Products are accompanied by a one

dollar (new purchase) for one dollar (credit return) order.

3. Products were purchased within on

year from credit return date and are in a current catalog.

4. Products are subject to a 10% per

RMA and $2.00 per line item. 5. Products that are custom made are

subject to an additional charge for

conversion of not less than 20% and not more than 50% of the FFP

price.

6. Product that require factory repacking are subject to an

additional charge for material and

labour.

7. Please contact Lindsay Broadband

Customer Service to obtain an RMA#.

Any shipments received by

Lindsay Broadband without

an RMA# will be refused.

Note: Products that are judged by

Lindsay Broadband Inc. upon receipt as

being unacceptable for credit shall be

returned to sender at their expense.

SHIPPING INSTRUCTIONS

1. Make Sure to Obtain an RMA# and mark a box(s) accordingly

2. Ship Only Items Authorized

3. Enclose Packing Slip & Product

Return Authorization Form

4. Ship Prepaid Only to :

Lindsay Broadband Inc

2-2035 Fisher Dr.

Peterborough, ON CANADA

K9J 6X6

Attn: Product Returns