Laser Syntech From China
-
Upload
medica-persada -
Category
Documents
-
view
26 -
download
1
description
Transcript of Laser Syntech From China
Handpiece ApplicationHandpiece Name Applications Specifications
Long Pulse Nd:YAG Laser
Standard treatment tip
Variable spot size tip 5-12
Variable spot size tip 2-6
Permanent hair reduction
Leg vein
Deep wrinkle
Wavelength: 1064nm
Energy: up to 18J
Pulse Width: 3~10ms
Spot Size:
1.5mm;3mm;5mm;8mm
Spot Size: 5mm~12mm
Spot Size: 2mm~6mm
Long Pulse Nd:YAG Laser
with cooling
Standard treatment tip
Permanent hair reduction
Leg vein
Deep wrinkle
Wavelength: 1064nm
Energy: up to 18J
Pulse Width: 3~10ms
Spot Size:
1.5mm;3mm;5mm;8mm
Er:YAG Laser
Standard treatment tip
Standard Fractional tip
Square Fractional tip
Wrinkle and fine lines
Skin peeling
Pigment lesions
Acne scar
Wavelength: 2940nm
Energy: up to 2J
Pulse Width: 0.5~3ms
Spot Size:
1mm;3mm;6mm;9mm
Spot Size: 8mm
Spot density: 100dpcm
Spot Size: 9mm*9mm
Er:glass Laser
Standard Fractional tip
Variable spot size tip
Non-ablative skin
resurfacing Acne scar and surgical scar
Wavelength: 1535nm
Energy: up to 5J
Pulse Width: 3~10ms
Spot Size: 8mm
Spot density: 100dpcm
Spot Size: 5mm~11mm
Long Pulse Nd:YAG Laser
Standard Fractional tip
Skin Resurfacing
Skin rejuvenation
Scar Revision
Wavelength: 1320nm
Energy: up to 12J
Pulse Width: 3~10ms
Spot Size: 8mm
Spot density: 100dpcm
Q-Switched Nd:YAG Laser
2mm tip
4mm tip
532 tip
Tattoo removal
Skin rejuvenation with
carbon solution Reducing pore size
and sebum level
Wavelength: 1064nm
Energy: up to 800mJ
Standard cooling IPL HR
Standard cooling IPL SR
Standard cooling IPL VR
Standard cooling IPL AR
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
IPL Output:5-40J/cm2
Spotsize:40*8mm2;
Cooling:0-5℃
Standard 4 in 1 IPL
Crystal filter
(HR/SR/VR/AR)
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
IPL Output:5-25J/cm2
Filter: HR SR VR AR
Spotsize:40*10mm2
Standard cooling 4 in 1 IPL
Sheet filter A
(HR/SR/VR/AR)
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
IPL Output:5-25J/cm2
Filter: HR SR VR AR
Spotsize:40*10mm2
Big spot IPL HR
Big spot IPL SR
Big spot IPL VR
Big spot IPL AR
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
IPL Output:5-20J/cm2
Spotsize:40*16mm2;
Super Size cooling IPL
Sheet filter B
(HR/SR/VR/AR)
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
IPL Output:5-20J/cm2
Spotsize:50*16mm2;
Standard E-light HR
Standard E-light SR
Standard E-light VR
Standard E-light AR
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
RF output:0-100J/cm3
IPL Output:5-40J/cm2
Spotsize:40*8 mm2;
Cooling:0-5℃ Small E-light HR
Small E-light SR
Small E-light VR
Small E-light AR
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
RF output:0-100J/cm3
IPL Output:5-40J/cm2
Spotsize:24*8 mm2;
Cooling:0-5℃
Standard cooling 4 in 1
E-light
Sheet filter A
(HR/SR/VR/AR)
Hair removal
Skin rejuvenation
Vascular removal
Acne removal
RF output:0-100J/cm3
IPL Output:5-35J/cm2
Spotsize:40*8 mm2;
Cooling:0-5℃
RF Handpiece for face
RF Handpiece for body
Body shaping and slimming
Improving skin texture
and laxity Tightening skin and
shrinking the skin pores
Bipolar
Power : 50 W
Frequency : 10 MHz
Size :
Face: Φ24mm
Body: Φ44mm
Introduction
Trixel series fractional CO2 laser enable you to penetrate even deeper, optimizing collagen remodeling while reducing downtime. The
remarkable small spot size and easy control of density give you the ability to offer true customizable treatments. It’s the new, superior
"Gold Standard" for Laser Skin resurfacing and rejuvenation with the highest safety.
Advantage
Fast treatment
Super treatment area and high pulse energy can enable you to treat an entire face in as little as 10 minutes.
Micro single dot
Minimum 120micrometers small spot size delivery to deeper skin.
Customizable treatments
Control the pattern, density and energy easily, offer the flexible possibilities of treatments.
Cost-effective
5 years warranty for RF excited CO2 laser tube, no Consumables, offer affordable with a high return
on investment.
Fractional Scanner Pattern Size & Shape
Trixel fractional CO2 laser is compact and
potable, so that moves easily.
Trixel-II fractional CO2 laser is the high power system which
allows the Ultrapulse to treat with safe and effective pulse
durations.
Specification Trixel Fractional CO2 Laser Trixel-II Fractional CO2 Laser
Shape Portable Standing
Model CFL-10 CFL-25 CFL-30 UFL-60
Peak Power 12W 30W 30W 60W
Type of laser tube metal metal metal metal
Operation Mode CW CW CW Ultra pulse
Max Scan Area 30×30 mm2 30×30 mm2 30×30 mm2 20×20 mm2
Wavelength 10.6 μm
Spot Energy 0.1-200 mJ
Spot Density 25-1600 spots/cm2
Delivery System 7-Jointed Spring-Balance Articulated Arm
Aiming Beam 650 nm/5 mW
Dimensions 630×330×225 mm3 420×500×1150 mm3
Weight 20 Kg 50 Kg
Electrical 230 V AC/50-60 Hz 16 A, Or 120 V AC/50-60 Hz 16 A
Metal tube is RF Excited CO2 laser.
PrincipleThe advanced technology of Q-switched and KTP laser are
adopted in the equipment which can release laser energy
instantaneously to form huge impulse. It can break pigment tissue
into pieces so we can achieve the purpose of pigment and tattoo
removal while not injuring the skin and no scar.left
Applications The equipment of laser with 1064nm wavelength:
It can get rid of eye line:eyebrow line, lip line, tattoo, speckle
(black, blue, etc.); The equipment of laser with 532nm wavelength:
It can get rid of eyebrow line, eye line, lip line, tattoo, speckle, titian
nevus (red, brown, etc.);
Advantages
Small space, high energy and good result.
Specifications
Laser Type : Q-Switched: NAG Laser;
Wavelength : 1064nm/532nm;
Output : 200mj , 400mj , 600mj;
Pulse Duration : <20ns;
Pulse Rate : 1-5Hz;
Dimensions : 430 X 330 X 250mm3
Weight : 12Kg;
Electrical Req : 110 / 220V AC,16A,50 / 60Hz ;
The 1550nm Erbium Glass Laser includes the leading non-
ablative fractional technology, when it works, the system fires
numbers of microscopic beam of 1550nm laser, producing
fractional treatment zones within the selected target area of the
skin through tiny dots, but leaving the other zones within it
perfectly intact. So, the heat of laser only passes deeply through
the fractional damaged area. This allows the skin to heal much
faster than if the whole area was treated., Then plenty of collagen
will be produced for skin rejuvenation during the skin self-
resurfacing
Applications Advantage
Periorbital and Perioral Wrinkles;
Acne scar and surgical scar;
Age spots and sunspots;
Photo-damage,Uneven Skin Tone,Textural Roughness
Patient satisfaction;
Easy and safe to use;
Minimal risk for side effect;
No downtime
Scanning Pattern
Specifications
Light Source Er:Glass Fiber Fractional Laser Spot Density 25 - 10000 (spots/cm2 )
Wavelength 1550 nm Electrical 110 / 220V AC,16A,50 / 60 Hz
Max Treatment Area 20mm X 20mm Dimension 435 X 550 X 1145 mm3
Energy Per Point 1mJ - 200mJ Weight 50Kg