Laminated Bearer Beam Assembly
-
Upload
rolando-benjamin-carlos-vallejo -
Category
Documents
-
view
224 -
download
0
Transcript of Laminated Bearer Beam Assembly
-
7/31/2019 Laminated Bearer Beam Assembly
1/4
ONGSPAN
lintels R
2
5 5 0 8 M A
X
0 m i n
4 5
1
This system comprises two L-shaped Kwiklin beams erected side by side to form a U-beam.Galvanised steel bushes laminate beams together.Prescribed reinforcing steel, if required.40 Mpa. concrete infill
! Beam mass 51kg / meter per beam.! Standard stock lengths cast 5400 / 6450 / 7500 / 8550mm (cut to order length).! Engineering load capacity tables and construction notes available.! N.B. KWIKLIN application and supporting columns to be specified and constructed under
supervision of a professional engineer
DESCRIPTION1
2
3
4
3
4
For Fast Track Installation Of 250mm High X 220mm Wide (variable) Load Bearing Prestressed Concrete Beams
Kwik Lin RLaminated Bearer Beam Assembly.
Chris - 083 549 4753Port ElizabethEast London
Donovan - 082 329 4535
one o f ou r
-
7/31/2019 Laminated Bearer Beam Assembly
2/4
1. Longspan Lintels supply Kwiklin beams in matched pairs in standard lengths of 5400m, 6450mm,
7500mm or 8550mm cut to length as required.2. The supporting columns must be constructed (use minimum quality 7 Mpa bricks and blocks) as
directed by the engineer. Structure must b e well cured, sound and level before placing beams.(Non shrink grout can be used to level up and bond top brickwork if necessary).
3. Set up secure scaffold and heavy duty boards to accommodate required lifting crew for placingmanually. Longer beams may require a crane or lifting tackle which can be provided.
4. Beams must be lifted with two slings on a spreader bar when using a crane or tackle.
5. Set up and l ine up the two Kwikl in beams.Tap in required number of laminating galvanised steel bushes.Using locating saddles clipped onto the bushes, set reinforc ing in place as required
by engineer.Caulk th e gap between the beams or t ie up a shut ter board when creating a wider beam(260/280mm wall applications.)Set-up singl e prop in c entre of beam assembly.Cast 40 MPA concr ete into beam (16 litres requir ed per running meter)
6. Steel imbedded in supporting column brickwork should be secured through the joint in theKwiklins and tied in by the concrete infill in the bearer beam to create a connected structure.
7. Where practical, it is advisable to place the first course of brickwork immediately above theKwiklin assembly as a header course.
8. Subsequent course to be laid with galvanised brickforce in the mortar joints.
9. Alternatively, the strength of the beam can be further increased by integrating reinforcing upthrough the upper brickwork constructed as a cavity wall so as to admit further reinforcedconcrete infill between the leaves.
10. Hoop iron can also be wrapped around reinforcing bar and passed up through the brickwork tosecure the roof rafters, before casting concrete beam infill.
>>>>>>
>>
>>>>
Installation Construction& NotesKwik Lin R
SECURE REBARWITH SADDLESSUPPLIED
TO FORM RING BEAM, MITRE CORNERS AT 45.TIE REBAR AROUND CORNERS
TIE RAFTERS TO REBARWITH HOOP IRON
REINFORCING SECURED WITH SPACER SADDLE FITTED TO BUSHES
45
-
7/31/2019 Laminated Bearer Beam Assembly
3/4
Laminated Bearer Beam Engineering Data
NOTES:1) The tables satisfy SABS 0100 - latest revision
2) Calculations for table prepared by Mr. Colin Dunn Endecon Pe Trust (reg. No. 730442)
3) Kwiklins can be further reinforced by integrating reinforcing to the upper brickwork constructedso as to admit concrete infill between leaves.
4) Kwiklins spanning 6m clear with concrete infill and steel reinforcing, will carry 10 courses ofbrickwork without sagging. It is advisable to fit a temporary prop under the centre of theKwiklin assembly during construction when time does not permit for infill concrete orbrickwork to set.
5) Kwiklins must be applied under supervision and specification of aprofessional engineer.
Reinforced brickwork built up above, will enhance the shear capacity when hardened
250
CROSS SECTION OF KWIKLIN ASSEMBLY
LaminatingBushes
Fill Cavity With40 MpaCONCRETE
MINIMUM GAPVARIES
210OR TO REQUIRED WIDTH
100
1
Re-inforcingSteel securedin Saddle
Kwiklin Beam (x2)
4
2
3
Kwik Lin R
6) Kwiklin sets are produced instandard lengths of 5400, 6450, 7500and 8550mm and can be cut tospecial order lengths.
7) Mass 51kg. per meter per singlebeam.
Other Lintels in the Longspan Range:Slimlin for double garage dooropenings of 4800mm.Winlin 250 for 6 meter openings.Winlin 200 for up to 5 meteropenings (aligns with 200mm.block courses)Winlin 170 for applications up to 4meter openings.
>>
>>>>
>>
ONGSPAN
lintels R
one of our
90
15 + 12 Y/M 80 + 12 Y/M
112
-
7/31/2019 Laminated Bearer Beam Assembly
4/4
ONGSPAN
lintels
Laminated Bearer Beam Assembly
&
S T
E P
Kwik Lin R
East Londo nP.O. Box 3179, Ca m bridg e, 5206
Nahoo n Da m Roa d, East Lond on Dist ric tTel: 043-74 5 2264 Fax: 086 509 4397
E -m a i l : m m a ngo ld@mweb .co . zawww.s t ep a n d deckeas t cape . co . za
Suspended Office extension by owner - Fanie Venter - 30 Cape Road, Port ElizabethFanie se Die Kwiklin en Windeck sisteems het die konstruksie vinnig laat voerentoe en soos maklik, net soon
Meccano aanmekaar gelas.
Kwiklin beams set 280mm wideR/C filled
Mitred bearer reinforced to connectround corner and to column
EASY-PEAZYwith Seamless Construction
and no DelayHouse: Lee Melli n
Kwiklin spanning 7500mm to support Gable todouble volume entertainment room bearer
beam R.C. Filled cast 280mm wide
and carry Windeck DB 200 3600 x4500 suspended floor systems