L2 trigger: chi2 tuning (includes changes/comments discussed in the meeting) Carmen Diez Pardos...
-
Upload
mervyn-ross-ryan -
Category
Documents
-
view
216 -
download
0
Transcript of L2 trigger: chi2 tuning (includes changes/comments discussed in the meeting) Carmen Diez Pardos...
L2 trigger: chi2 tuningL2 trigger: chi2 tuning
(includes changes/comments discussed in the meeting) (includes changes/comments discussed in the meeting)
Carmen Diez PardosSilvia Goy López
CIEMAT Madrid
11/01/2012
1C. Diez Pardos
Check effect of changing chi2 Check effect of changing chi2 ValidHits distributions: # of L2 with none validhits Effect on resolution (compared to offline pT)
Data: 2011RunB Zskim (~55K events)(/SingleMu/Run2011B-ZMu-PromptSkim-v1) SELECTION: events with a good offline Muon:
Tracker&Global, chi2<10, relIso<0.15, ValidHits>10, ValidMuonHits>0, MatchedStations>1, pixelHits>0, abs(eta)<2.1
1. Resolution: hltL2MuonCandidate matched to the closest (smallest DeltaR) offline muon
2C. Diez Pardos
ValidHits with different chi2ValidHits with different chi2
3C. Diez Pardos
chi2 #0ValidHit
/Total
#0ValidHit/Total
400 0.0053 0.0016
350 0.0055 0.0014
300 0.0059 0.0011
250 0.0065 0.0010
100 0.0134 0.0019
25 0.0354 0.00952
L2MuonCandidates matched to the CLOSEST offline muon
For chi2>300 rather small difference
1/pT resolution 1/pT resolution 1/pT resolution 1/pT resolution
chi2 RMS
(ValidHits>0)
SIGMA RMS
(All L2)
SIGMA
(All L2)
400 0.2434 0.2504 0.1522 0.1449 0.2417 0.1527
350 0.2431 0.2498 0.1520 0.1448 0.2414 0.1526
300 0.2424 0.2489 0.1518 0.1447 0.2407 0.1524
250 0.2422 0.2457 0.1512 0.1445 0.2439 0.1519
100 0.2376 0.2414 0.1491 0.1438 0.2404 0.1503
25 0.2321 0.2364 0.1441 0.1417 0.2391 0.1471
pT resolution pT resolution
chi2 RMS
(ValidHits>0)
SIGMA RMS
(All L2)
SIGMA
(All L2)
400 0.2565 0.2509 0.1611 0.1556 0.2616 0.1616
350 0.2555 0.2496 0.1609 0.1554 0.2608 0.1614
300 0.2540 0.2485 0.1606 0.1551 0.2595 0.1612
250 0.2560 0.2468 0.1599 0.1547 0.2559 0.1605
100 0.2485 0.2379 0.1562 0.1525 0.2513 0.1572
25 0.2352 0.2281 0.1500 0.1496 0.2450 0.1530
Efficiency (HLT_Mu24, HLT_Mu40) Efficiency (HLT_Mu24, HLT_Mu40)
10C. Diez Pardos
Efficiency for positive charged muon 0.2% higher than for negative muons
Tag+Probe pairs Mmumu (60,120) GeV + criteria Slide1pt> 30 GeV (40 GeV for HLT_Mu40)
chi2 HLT_Mu24 (%)
(stat error ~ 0.002)
(no cut in ValidHits)
HLT_Mu40(stat
error ~ 0.003)
HLT_Mu24 (%)
(stat error ~ 0.002)
(no cut in ValidHits)
HLT_Mu40(stat
error ~ 0.003)
400 91.889 91.271 91.917 91.427
350 91.904 (92.230)
91.223
(91.530)
92.042 (92.230)
91.492
(91.530)
300 91.902 91.200 92.067 91.556
250 91.892 (92.253)
91.196 (91.530
)
92.119 (92.253)
91.541(91.530
)
100 91.679 91.902 92.582 91.874
25 91.500(92.546)
90.686 (91.733
)
92.715(92.546)
92.037(91.733
)