KX-TDA200/100 SystemKX-TDA200/100 System (Production Version 2.02Production Version 2.02)
Chapter 1System Capacity and
System Resources
Panasonic Communications Co., Ltd.Panasonic Communications Co., Ltd.
Office Network CompanyOffice Network Company
Edition 1.0 31 May, 2006Edition 1.0 31 May, 2006
![Page 2: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/2.jpg)
2Confidential
Index
1. System Capacity2. System Resources
![Page 3: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/3.jpg)
3Confidential
1. System Capacity
Function
![Page 4: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/4.jpg)
4Confidential
1.System Capacity(1/14)
Full free slot for TDA100/200
Line Type TDA100 TDA200
Trunk 6 8
Extension 6 8
Total 6 11
Line Type TDA100 TDA200
Trunk 4 8
Extension 4 8
Total 5 10
OLD NEW (Ver.3)< Card (1/3) >
free slots 1 to 10 free slots 1 to 11
free slots 1 to 5 free slots 1 to 6
![Page 5: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/5.jpg)
5Confidential
Card TypeCard TypeMaximum NumberMaximum Number
KX-TDA100KX-TDA100 KX-TDA200KX-TDA200
LCOT / DID / LCOT / DID / E&M / BRI E&M / BRI 66 88
T1 / E1 / PRIT1 / E1 / PRI 44 44
IP-GWIP-GW 44 44
DHLC / DLC / DHLC / DLC / SLC / IP-EXTSLC / IP-EXT 66 88
CSIFCSIF 44 44
CTI-LinkCTI-Link 11 11
MECMEC 11 11
RMTRMT 11 11
OPB3OPB3 44 44
PSU-SPSU-S 6464 xx
PSU-MPSU-M 128128
PSU-LPSU-L xx 512512
Terminal Terminal Equipment TypeEquipment Type
KX-TDA100KX-TDA100 KX-TDA200KX-TDA200
W/O MECW/O MEC W/I MECW/I MEC W/O MECW/O MEC W/I MECW/I MEC
EXTEXT 6464 160160 128128 256256
SLTSLT 6464 9696 128128 128128
T76 DPTT76 DPT 6464 128128 128128 256256
T7560/65 DPTT7560/65 DPT 6464 9696 128128 128128
Other DPTOther DPT 3232 3232 128128 128128
APTAPT 2424 2424 6464 6464
IP-PTIP-PT 6464 9696 128128 128128
DSS ConsoleDSS Console 88 88
CSCS 3232 3232
PSPS 128128 128128
VMVM 22 22
Door phoneDoor phone 1616 1616
Door openerDoor opener 1616 1616
Ext. SensorExt. Sensor 1616 1616
Ext. RelayExt. Relay 1616 1616
1.System Capacity(2/14)
![Page 6: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/6.jpg)
6Confidential
1. System Capacity(3/14)
Card Type
PRI, E1, T1, IPGW, CSIF
New
Max. 4
Old
Max. 2
TDA100
New Old
Max. 4 cards for PRI/E1/T1/IPGW/CSIF
Max. 2 cards for PRI/E1/T1/IPGW/CSIF
< Card (2/3)>
![Page 7: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/7.jpg)
7Confidential
1. System Capacity(4/14)TDA30< Card (3/3)>
E1 Yes No
Card Type New Old
![Page 8: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/8.jpg)
8Confidential
1.System Capacity(5/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 LCOT16 Cell Station for DLC/DHLC card 0 Slot 4 LCOT16 Cell Station for CSI/F card 0 Slot 5 LCOT16
IP-PT * 0 Slot 6 LCOT16 SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64 PSU Type : Power-S
Total PT+SLT : 64 MEC Card : Not RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100w/o MEC(1/2)
Total:64+64=128
![Page 9: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/9.jpg)
9Confidential
1.System Capacity(6/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 PRI Cell Station for DLC/DHLC card 0 Slot 4 PRI Cell Station for CSI/F card 0 Slot 5 PRI
IP-PT * 0 Slot 6 PRI SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64 PSU Type : Power-S
Total PT+SLT : 64 MEC Card : Not RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100w/o MEC(2/2)
Total:64+120=184
![Page 10: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/10.jpg)
10Confidential
1.System Capacity(7/14)
KX-TDA200 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 Cell Station for CSI/F card 0 Slot 5
LCOT16
IP-PT * 0 Slot 6
LCOT16
SLT * 0 Slot 7 Slot 8
Total Port Number of KX-TV (DPT Integration) Slot 9 First VM Unit 0 CH 0 Slot10
Second VM Unit 0 CH 0 Slot11
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128 PSU Type : Power-M
Total PT+SLT : 128 MEC Card : Not RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
LCOT16
DLC16
DLC16LCOT16LCOT16LCOT16
LCOT16
< Port >TDA200w/o MEC(1/2)
Total:128+112=240
![Page 11: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/11.jpg)
11Confidential
1.System Capacity(8/14)
KX-TDA200 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 Cell Station for CSI/F card 0 Slot 5
IP-PT * 0 Slot 6 SLT * 0 Slot 7
Slot 8Total Port Number of KX-TV (DPT Integration) Slot 9 First VM Unit 0 CH 0 Slot10
Second VM Unit 0 CH 0 Slot11
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128 PSU Type : Power-M
Total PT+SLT : 128 MEC Card : Not RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
DLC16
DLC16PRIPRIPRI
PRI
< Port >TDA200w/o MEC(1/2)
Total:128+120=248
![Page 12: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/12.jpg)
12Confidential
1.System Capacity(9/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 IP-EXT16
IP-PT * 32 Slot 6 IP-EXT16 SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128 PSU Type : Power-M
Total PT+SLT : 160 MEC Card : RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100with MEC(1/4)
Total:160+0=160
![Page 13: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/13.jpg)
13Confidential
1.System Capacity(10/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 LCOT8/16
IP-PT * 0 Slot 6 LCOT8/16 SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128 PSU Type : Power-M
Total PT+SLT : 128 MEC Card : RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100with MEC(2/4)
Total:128+32=160
![Page 14: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/14.jpg)
14Confidential
1.System Capacity(11/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 DLC16 Cell Station for DLC/DHLC card 0 Slot 4 DLC16 Cell Station for CSI/F card 0 Slot 5 PRI
IP-PT * 0 Slot 6 PRI SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 128 PSU Type : Power-M
Total PT+SLT : 128 MEC Card : RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100with MEC(3/4)
Total:128+60=188
![Page 15: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/15.jpg)
15Confidential
1.System Capacity(12/14)
KX-TDA100 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 PRI Cell Station for DLC/DHLC card 0 Slot 4 PRI Cell Station for CSI/F card 0 Slot 5 PRI
IP-PT * 0 Slot 6 PRI SLT * 0 N/A
N/A
Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH 0 N/A Second VM Unit 0 CH 0 N/A
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 64 PSU Type : Power-S
Total PT+SLT : 64 MEC Card : Not RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
< Port >TDA100with MEC(4/4)
Total:64+120=184
![Page 16: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/16.jpg)
16Confidential
1.System Capacity(13/14)
KX-TDA200 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 Cell Station for CSI/F card 0 Slot 5
LCOT
IP-PT * 0 Slot 6
LCOT
SLT * 0 Slot 7 Slot 8
Total Port Number of KX-TV (DPT Integration) Slot 9 First VM Unit 0 CH 0 Slot10
Second VM Unit 0 CH 0 Slot11
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 256 PSU Type : Power-L
Total PT+SLT : 256 MEC Card : RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
LCOT
DLC16
DLC16DLC16DLC16DLC16
DLC16
< Port >TDA200with MEC(1/2)
Total:256+48=304
![Page 17: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/17.jpg)
17Confidential
1.System Capacity(14/14)
KX-TDA200 Power Supply Unit & MEC Calculation Tool
Input
Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128
Other DPT 0 Card Installation KX-T7640 DSS Console 0 Slot 1 DLC16 Other DSS Console 0 Slot 2 DLC16
APT 0 Slot 3 Cell Station for DLC/DHLC card 0 Slot 4 Cell Station for CSI/F card 0 Slot 5
PRI
IP-PT * 0 Slot 6
PRI
SLT * 0 Slot 7 Slot 8
Total Port Number of KX-TV (DPT Integration) Slot 9 First VM Unit 0 CH 0 Slot10
Second VM Unit 0 CH 0 Slot11
*) PSU type is not effect by SLT/IP-PT numbers.
Result
Total Power Factor : 256 PSU Type : Power-L
Total PT+SLT : 256 MEC Card : RequiredPower-S/M is for KX-TDA100. Power-M/L is for KX-TDA200.Power-M supports up to 128 points. Power-S supports up to 64 points.
PRI
DLC16
DLC16DLC16DLC16DLC16
DLC16
< Port >TDA200with MEC(2/2)
Total:256+90=346
![Page 18: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/18.jpg)
18Confidential
2. System resource
Function
![Page 19: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/19.jpg)
19Confidential
2.System Resources (1/4)
Resources
Network DSS Key(TDA0920)
New
250
Quick Dial 80 (4 digits)
Quick Dial with MEC card 80(4digits)+4,000(8digits)
ICD Group 128
ICD Group Member 32
ICDG Member(sales C mode) 128
Old
32
80 (4 digits)
80 (4 digits)
64
32
TDA100/TDA200
Quick Dial with MEC card 80(4digits)+1,000(8digits) 80 (4 digits)
TDA30
![Page 20: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/20.jpg)
20Confidential
Network DSS Key
NDSS
up to 250
Network PBX ID up to 8
TDA0920is required.
NDSS Key Table
Network Data Transfer
2.System Resources (2/4)
![Page 21: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/21.jpg)
21Confidential
Quick Dial expansion
With MEC
Up to 4,000 with MEC
Up to 80 without MEC
Quick Dial
Basic Memory
MEC Memory
2.System Resources (3/4)
![Page 22: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/22.jpg)
22Confidential
ICD Group expansion Sales Company
Level
Enable 128 extensions
128 extensions
128 ICD groups
Miscellaneous
ICD Group
ICD Group Member
2.System Resources (4/4)
![Page 23: KX-TDA200/100 System ( Production Version 2.02 )](https://reader036.fdocuments.net/reader036/viewer/2022062518/56814659550346895db3758b/html5/thumbnails/23.jpg)
23Confidential
Thank you very much !Thank you very much !