KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk...

4
Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia Pty Ltd kinesis-australia.com.au KX VaporSafe Solvent Safety for HPLC Activated Car

Transcript of KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk...

Page 1: KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia

Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia Pty Ltd kinesis-australia.com.au

KX VaporSafe™

Solvent Safety for HPLC

Activ

ated

Car

bon

Page 2: KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia

Solvent Delivery and Organic Solvent Waste

¼"-28 flat bottom fitting for ¹/8" OD tubing

120μm particular filter

PTFE plug

PTFE cap body

ETFE seal

PP collar

FFKM Seal

KX VaporSafe™ Bottle Caps minimize hazardous VOCs evaporating from the reservoir into the laboratory, keep mobile phases clean and securely connect the solvent reservoir with any HPLC system.

Safety & CleanlinessThe PTFE body of the cap creates a tight seal against the mobile phase reservoir.

Tubing is connected using liquid and air tight fittings into the threaded connection ports. The air entering the container when solvent is withdrawn is filtered through a 120µm PTFE particulate filter. A built-in check valve prevents solvent vapours escaping into the lab through the particulate filter.

All materials used are highly solvent compatible: Polypropylene (collar), PTFE (body) and FFKM (seals), making the caps useable in any LC laboratory.

Connections KX VaporSafe™ Bottle Caps for GL45 bottles are available with two or four connection ports. The threaded connection ports allow connecting 1/8” or smaller OD tubing, which is securely fastened using standard ¼”-28 flat bottom fittings.

Complete Bottle caps and accessories are offered individually and as complete kits. A kit contains either one or four bottle caps complete with fittings for 1/8” OD tubing and plugs for unused ports.

From Solvent Delivery

Page 3: KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia

Solvent Delivery and Organic Solvent Waste

KX VaporSafe™ Waste Manifolds contain and adsorb hazardous solvent vapours and connect the LC system safely to the organic solvent waste container, creating a completely closed solution.

A safer HPLC workplace The KX-VaporSafe™ Waste Manifold attaches to the organic solvent waste container and seals it air tight.

Each manifold offers multiple connection ports for any waste line leaving the LC system to be securely fastened.

The activated carbon filter adsorbs any hazardous solvent vapours. A breakthrough colour indicator shows when the carbon filter is loaded and needs to be replaced.

The free spinning collar allows for quick disconnect of the solvent waste container once it is filled.

Activ

ated

Car

bon

Indicator EF-102

EF-100 Exhaust Filter

[ ]UNEXPOSED EXPOSEDEXPOSED – CHANGE IMMEDIATELY

Filter Cartridge (included)

Organic Solvent Waste

Filter Adapter(included)

Fittings(included)

Ready to use KX VaporSafe™ Waste Manifolds are available to fit a wide variety of standard and specialised solvent waste containers.

Manifold kits are the complete solution for HPLC solvent waste.

A kit comes complete with:

• Waste manifold, size specified with order

• Fittings for 1/8” and 1/16” OD tubing

• Fittings for 2.2, 2,5 and 3.0 mm metric tubing

• Adapters for 1/8”, ¼”. 3/8” ½” and metric ID soft wall tubing

• Siphoned soft wall tubing for overflow line

• Activated charcoal filter cartridge (100g)

• Optional solvent breakthrough indicator

Vapor breakthrough indicator The colour indicator is designed to indicate the end of service life for the KX VaporSafe exhaust filter. It changes colour, once the activated carbon is fully loaded with VOCs.

Please see online for a detailed list of compatible organic solvents.

To the Organic Solvent Waste

Plugs(included)

Manifold Body

Manifold Collar

Page 4: KX VaporSafekinesis.co.uk/wp-content/uploads/downloads/2013/05/KX...Kinesis Ltd kinesis.co.uk Kinesis Inc kinesis-usa.com Kinesis GmbH (formerly Abimed) kinesisgmbh.de Kinesis Australia

UNITED KINGDOMKinesis LtdTel: +44 (0)1480 212122 Fax: +44 (0)1480 212111 E-mail: [email protected] Web: kinesis.co.uk

AUSTRALIA & NEW ZEALANDKinesis Australia Pty LtdTel: +61 (0)7 3829 3996 Fax: +61 (0)7 3829 3997 Email: [email protected] Web: kinesis-australia.com.au

USA & CANADAKinesis IncTel: (518) 289-5817Toll free in USA: (866) 934-6353 Fax: (518) 289-5818 Email: [email protected] Web: kinesis-usa.com

GERMANY, SWITZERLAND & AUSTRIAKinesis GmbH (formerly Abimed) Tel: +49 (0)2173 89 05-0 Fax: +49 (0)2173 89 05-77 Email: [email protected] Web: kinesisgmbh.de

Safety Bottle Cap KitsPART NUMBER DESCRIPTION PACK SIZE

SV-305-K1 Bottle Cap, GL45, FFKM, 2 Port, Yellow, (1) Plug, (2) Fittings EA

SV-306-K1 Bottle Cap, GL45, FFKM, 4 Port, Yellow, (3) Plugs, (4) Fittings EA

SV-305-K4 4 x Bottle Cap, GL45, FFKM, 2 Port, Yellow, (4) Plugs, (8) Fittings EA

SV-306-K4 4 x Bottle Cap, GL45, FFKM, 4 Port, Yellow, (12) Plugs, (16) Fittings EA

Waste Manifolds with Fittings, Filter and Colour IndicatorPART NUMBER DESCRIPTION PACK SIZE

VSK-004-I GL38 with Filter, Indicator, Fittings EA

VSK-005-I GL45 with Filter, Indicator, Fittings EA

VSK-008-I 51mm Jerrican, with Filter, Indicator, Fittings EA

VSK-009-I 61mm Jerrican, with Filter, Indicator, Fittings EA

VSK-010-I 53B Carboy, with Filter, Indicator, Fittings EA

VSK-013-I 61mm Nampak, with Filter, Indicator, Fittings EA

VSK-014-I 70mm Hedwin, with Filter, Indicator, Fittings EA

VSK-015-I 70mm Nalgene, with Filter, Indicator, Fittings EA

VSK-016-I PP, Justrite Ctr., with Filter, Indicator, Fittings EA

VSK-017-I SS/PTFE, Justrite Ctr., with Filter, Indicator, Fittings EA

Replacement FiltersPART NUMBER DESCRIPTION PACK SIZE

EF-100 Replacement Filter Cartridge EA

EF-100V Replacement Filter Cartridge PK/5

EF-I-100 Replacement Filter Cartridge with Indicator EA

EF-I-100V Replacement Filter Cartridge with Indicator PK/5

Solvent Waste SystemsPART NUMBER DESCRIPTION PACK SIZE

VSS-005B-I 5L Solvent Waste System, Complete (Container, Manifold, Fittings, Filter, Indicator) EA

VSS-010-I 10L Solvent Waste System, Complete (Container, Manifold, Fittings, Filter, Indicator) EA

VSS-020-I 20L Solvent Waste System, Complete (Container, Manifold, Fittings, Filter, Indicator) EA

Kinesis recognise all trademarks and registered trademarks. E&EO KLTD-1053-0113

kinesis.co.uk/kx-vaporsafe

Please contact us for more available sizes.