Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder...

36
Kuhnke Technical Data The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details Kuhnke sales and service in the UK H. Kuhnke Ltd Unit 6 Focus 303 Focus Way, Walworth Business Park Andover Hampshire SP10 5NY United Kingdom Tel: +44 (0)1264 364194 Fax: +44 (0)1264 365991 Email: [email protected] Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

Transcript of Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder...

Page 1: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Kuhnke Technical Data

The following page(s) are extracted from multi-page Kuhnke product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogues, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files. Contact Details

Kuhnke sales and service in the UK H. Kuhnke Ltd Unit 6 Focus 303 Focus Way, Walworth Business Park Andover Hampshire SP10 5NY United Kingdom Tel: +44 (0)1264 364194 Fax: +44 (0)1264 365991 Email: [email protected]

Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.

Page 2: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 32 gArmature: appr. 8 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 B 75Test voltage: 800 V (eff)Protection: IP 00

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 32 g

Anker: ca. 8 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 B 75Prüfspannung: 800 V (eff)Schutzart: IP 00

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHM 107

Stoßende oder ziehende Ausführung

Linear SolenoidHM 107

Thrust or pull type

Magnet Hauptkatalog 54 Main catalogue

HM 1 57 - F

24 V DC 100% ED

Zul. rel. Einschaltdauer (ED)2) % 100 70 45 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)3)

Wms

2,834

4,3 6,5 10 18 528

Wms

Nominal coil power P 20Actuation time (ED)3)

2) Bei Montage auf eine Kühlfläche von mindestens 30 cm2 ist die 1,3fache ED zulässig

3) Bei 5 mm Hub

2) If solenoid is mounted directly onto a flat metal surface of at least 30 cm2, the duty cycle can be extended up to 1.3 x nominal rating

3) Stroke 5 mm

Bestellformel HM 1 07 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

HM1

Linear solenoidSizes

Bauart

Anschlußart

Zugmagnet mit KonusankerStoßmagnet mit Konusanker

0757

Design type

Coil terminals

Pull type solenoid with conical face armatureThrust type solenoid with conical face armature

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm) F24 Nominal voltage (standard voltage)1)

100 % ED Perm. duty cycle under air cooled conditions (LK)

Flying leads (10 cm standard length)

1) Die Magnete sind auf Anfrage bis 60 V DClieferbar

1) Other voltages are available on request up to 60 V DC

0 1 2 3 4 5 76S [mm]

F [N

]

0,060,080,1

0,20,3

56 %ED

1007045

25

15

5

0,5

1

2

3

Page 3: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHM 107

Stoßende oder ziehende Ausführung

Linear SolenoidHM 107

Thrust or pull type

Magnet Hauptkatalog 55 Main catalogue

8

≤0,5

11,5

Ø5,

2

M3

103815

2

Ø6

169

48,2

2

3,5

5

55

16 9

M2

≤0,5

11,5

Ø5,

2

M3

103815

Ø6

±0,316,5

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet HM 107 Series HM 107 pull type solenoid

Stoßmagnet HM 157 Series HM 157 thrust type solenoid

Page 4: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 67 gArmature: appr. 15 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 B 75Test voltage: 800 V (eff)Protection: IP 00

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 67 g

Anker: ca. 15 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 B 75Prüfspannung: 800 V (eff)Schutzart: IP 00

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHM 207

Stoßende oder ziehende Ausführung

Linear SolenoidHM 207

Thrust or pull type

Magnet Hauptkatalog 56 Main catalogue

Bestellformel HM 2 07 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

HM2

Linear solenoidSizes

Bauart

Anschlußart

Zugmagnet mit KonusankerStoßmagnet mit Konusanker

0757

Design type

Coil terminals

Pull type solenoid with conical face armatureThrust type solenoid with conical face armature

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm) F24 Nominal voltage (standard voltage)1)

100 % ED Perm. duty cycle under air cooled conditions (LK)

Flying leads (10 cm standard length)

HM 2 5 7 - F

24 V DC 100% ED

1) Die Magnete sind auf Anfrage bis 60 V DClieferbar

1) Other voltages are available on request up to 60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 60 35 25 15 10 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)3)

Wms

4,529

7,9 12,5 19 39 45 699

Wms

Nominal coil power P 20Actuation time (ED)3)

2) Bei Montage auf eine Kühlfläche von mindestens 45 cm2 ist die 1,3fache ED zulässig

3) Bei 5 mm Hub

2) If solenoid is mounted directly onto a flat metal surface of at least 45 cm2, the duty cycle can be extended up to 1.3 x nominal rating

3) Stroke 5 mm

0 2 4 6 8 10S [mm]

F [N

]

0,1

0,2

0,50,7

0,3

10 %ED

1

2

34568

100

35

25

60

15

510

Page 5: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHM 207

Stoßende oder ziehende Ausführung

Linear SolenoidHM 207

Thrust or pull type

Magnet Hauptkatalog 57 Main catalogue

8≤0,5

15

Ø6,

2

M4

105030

8

3,563

1810

,5

Ø2

15

Ø6,

2

M4

105030

Ø 8

25,5±0,3

M3

6

≤0,5

77,5

1810

,5

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet HM 207 Series HM 207 pull type solenoid

Stoßmagnet HM 257 Series HM 257 thrust type solenoid

Page 6: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 27 gArmature: appr. 5 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 C 150Test voltage: 800 V (eff)Protection: IP 00

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 27 g

Anker: ca. 5 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 C 150Prüfspannung: 800 V (eff)Schutzart: IP 00

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHU 24

Stoßende oder ziehende Ausführung

Linear SolenoidHU 24

Thrust or pull type

Magnet Hauptkatalog 58 Main catalogue

Bestellformel HU 24 0 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

HU24

Linear solenoidSizes

Bauart

Anschlußart

ZugmagnetStoßmagnet

04

Design type

Coil terminals

Pull type solenoidThrust type solenoid

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm)Flachstecker (Faston; optional)

FA

24100 % ED

Nominal voltage (standard voltage)1)

Perm. duty cycle under air cooled conditions (LK)

Flying leads (10 cm standard length)Push-on connector (optional)

HU 240 - F

24 V DC 100% ED

1) Die Magnete sind auf Anfrage bis 60 V DClieferbar

1) Other voltages are available on request up to 60 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 40 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)3)

Wms

2,914

6,7 11 15 445

Wms

Nominal coil power P 20Actuation time (ED)3)

2) Bei Montage auf eine Kühlfläche von mindestens 100 cm2 ist die 1,3fache ED zulässig

3) Bei 4 mm Hub

2) If solenoid is mounted directly onto a flat metal surface of at least 100 cm2, the duty cycle can

be extended up to 1.3 x nominal rating3) Stroke 4 mm

0 21 3 4 5 6S [mm]

F [N

]

0,1

0,2

0,70,5

0,3

10 %ED

100

402515

5

1

2

345

8

Page 7: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHU 24

Stoßende oder ziehende Ausführung

Linear SolenoidHU 24

Thrust or pull type

Magnet Hauptkatalog 59 Main catalogue

9 14 16

M310 7

8

2Ø6

33

1017

,5

≤0,8

Ø2

3,5 24

91416

M310 7

≤0,8

M2

40

1017

,5

24

Ø6

15 ±0,3

8

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet HU 240 Series HU 240 pull type solenoid

Stoßmagnet HU 244 Series HU 244 thrust type solenoid

Page 8: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 55 gArmature: appr. 11 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 B 30Test voltage: 2500 V (eff)Long life expectancy through plasticbobbin armature bearing

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 55 g

Anker: ca. 11 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 B 30Prüfspannung: 2500 V (eff)Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHU 32

Stoßende oder ziehende Ausführung

Linear SolenoidHU 32

Thrust or pull type

Magnet Hauptkatalog 60 Main catalogue

Bestellformel HU 32 0 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

HU32

Linear solenoidSizes

Bauart

Anschlußart

ZugmagnetStoßmagnet

04

Design type

Coil terminals

Pull type solenoidThrust type solenoid

Nennspannung (Standardspannung)1)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

Litze (Standardlänge 10 cm)Flachstecker (Faston; optional)

FA

24100 % ED

Nominal voltage (standard voltage)1)

Perm. duty cycle under air cooled conditions (LK)

Flying leads (10 cm standard length)Push-on connector (optional)

HU 324 - F

24 V DC 100% ED

1) Die Magnete sind auf Anfrage bis 230 V DClieferbar

1) Other voltages are available on request up to230 V DC

Zul. rel. Einschaltdauer (ED)2) % 100 40 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20Anzugszeit (ED)

Wms

4,217

10 16 25 646

Wms

Nominal coil power P 20Actuation time (ED)

2) Bei Montage auf eine Kühlfläche von mindestens 100 cm2 ist die 1,3fache ED zulässig

2) If solenoid is mounted directly onto a flat metal surface of at least 100 cm2, the duty cycle can be extended up to 1.3 x nominal rating

0 1 2 3 4 75 6S [mm]

F [N

]

0,1

0,2

0,3

0,5

0,8

10 %ED

100

40

15

25

5

1

2

54

8

Page 9: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHU 32

Stoßende oder ziehende Ausführung

Linear SolenoidHU 32

Thrust or pull type

Magnet Hauptkatalog 61 Main catalogue

10 16 18

M320 6

8

2Ø8

≤0,5

32

1221

Ø2

3,541

101618

M320 6

≤0,5

4832 15 ±0,3

8

M3

1221 Ø

8

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet HU 320 Series HU 320 pull type solenoid

Stoßmagnet HU 324 Series HU 324 thrust type solenoid

Page 10: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Magnet Hauptkatalog 62 Main catalogue

Page 11: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Hubmagnete H

Solenoids Series H

Page 12: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 65 gArmature: appr. 13 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 B 75Test voltage: 2500 V (eff)

Long life expectancy through plasticbobbin armature bearing.The solenoid can also be supplied asspecial specification with service-free DUarmature bearing for maximumdurability.

Force vs. Stroke diagramm F = f (s)56

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 65 g

Anker: ca. 13 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 B 75Prüfspannung: 2500 V (eff)

Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper.In Sonderausführung ist dieser Magnetauch mit wartungsfreier Ankerlagerung(DU-Lager) für höchste Lebensdauerlieferbar.

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 22

Stoßende oder ziehende Ausführung

Linear SolenoidH 22

Thrust or pull type

Magnet Hauptkatalog 64 Main catalogue

Bestellformel H 22 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H22

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H2246-F

24 V DC 100%ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 45 25 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

5,224

10,2 19 29,5 757

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 45 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 45 cm2, the duty cycle can be extended up to 1.3 x nominal rating

0 1 2 3 4 5S [mm]

F [N

]

0,1

0,2

0,5

30 %ED

100

10025451525

5

15

45

1

23457

10

20

Page 13: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 22

Stoßende oder ziehende Ausführung

Linear SolenoidH 22

Thrust or pull type

Magnet Hauptkatalog 65 Main catalogue

2515

20

M3 32

8

Ø8 2

48,5 0,5

8153,5

M3

Ø2

2515

20

M3 32

815

M 4 (M )

M3

64,5 0,5

25,5 0,3

15 M3

8

Maße im bestromten Zustand

–––––––>Hubrichtung

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 2203/2206 Series H 2203/2206 pull type solenoid

Stoßmagnet H 2243/2246 Series H 2243/2246 thrust type solenoid

Page 14: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 85 gArmature: appr. 25 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 B 75Test voltage: 2500 V (eff)Long life expectancy through plasticbobbin armature bearing.

Force vs. Stroke diagramm F = f (s)

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 85 g

Anker: ca. 25 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 B 75Prüfspannung: 2500 V (eff)Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper.

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 24

Stoßende oder ziehende Ausführung

Linear SolenoidH 24

Thrust or pull type

Magnet Hauptkatalog 66 Main catalogue

Bestellformel H 24 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H24

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H2446-F

24 V DC 100% ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 70 45 25 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

623

9,1 13,8 23 40 1029

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 60 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 60 cm2, the duty cycle can be extended up to 1.3 x nominal rating

0 2 4 6 8S [mm]

F [N

]

0,30,40,60,8

1

2

50 %ED

10010075705030452515

155

5

5

810

20

40

Page 15: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 24

Stoßende oder ziehende Ausführung

Linear SolenoidH 24

Thrust or pull type

Magnet Hauptkatalog 67 Main catalogue

25

20

824M3 ≤0,5

Ø6,

5

14

4

3

4090,552

Ø10 3

25,5 0,34066,5

10 M3

25

20

824

14 Ø10

M3 ≤0,5

Ø6,

5

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 2403/2406 Series H 2403/2406 pull type solenoid

Stoßmagnet H 2443/2446 Series H 2443/2446 thrust type solenoid

Page 16: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 90 gArmature: appr. 17 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 36Test voltage: 2500 V (eff)Long life expectancy through plasticbobbin armature bearing.The solenoid can also be supplied asspecial specification with service-free DUarmature bearing for maximumdurability.

Force vs. Stroke diagramm F = f (s)

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 90 g

Anker: ca. 17 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 36Prüfspannung: 2500 V (eff)Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper.In Sonderausführung ist dieser Magnetauch mit wartungsfreier Ankerlagerung(DU-Lager) für höchste Lebensdauerlieferbar.

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 32

Stoßende oder ziehende Ausführung

Linear SolenoidH 32

Thrust or pull type

Magnet Hauptkatalog 68 Main catalogue

Bestellformel H 32 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H32

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H3246-F

24 V DC 100% ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 50 25 16 6 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

5,221

9,6 18,2 28,5 718

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 70 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 70 cm2, the duty cycle can be extended up to 1.3 x nominal rating

0 1 2 3 4 5S [mm]

F [N

]

0,10,20,30,40,60,8

30 %ED

100

50100

25

5016

6

166

25

1

23468

10

20

Page 17: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 32

Stoßende oder ziehende Ausführung

Linear SolenoidH 32

Thrust or pull type

Magnet Hauptkatalog 69 Main catalogue

4

Ø3

Ø10

9

3

30,5

617

18

M3

30

42,5±0,5

28

M3

20

15 M3

30,5

617

Ø10

M3

30

25,5±0,3

57

28

18

M3

20

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 3203/3206 Series H 3203/3206 pull type solenoid

Stoßmagnet H 3243/3246 Series H 3243/3246 thrust type solenoid

Page 18: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 140 gArmature: appr. 32 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 1.5 KV/3Test voltage: 2500 V (eff)Long life expectancy through plasticbobbin armature bearing.The solenoid can also be supplied asspecial specification with service-free DUarmature bearing for maximumdurability.

Force vs. Stroke diagramm F = f (s)

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 140 g

Anker: ca. 32 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 1,5 KV/3Prüfspannung: 2500 V (eff)Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper.In Sonderausführung ist dieser Magnetauch mit wartungsfreier Ankerlagerung(DU-Lager) für höchste Lebensdauerlieferbar.

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 34

Stoßende oder ziehende Ausführung

Linear SolenoidH 34

Thrust or pull type

Magnet Hauptkatalog 70 Main catalogue

Bestellformel H 34 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H34

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H3406-F

24 V DC 100% ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 35 25 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

845

23 30 57 14416

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 100 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 100 cm2, the duty cycle can beextended up to 1.3 x nominal rating

0 2 4 6 8 10 120,1

0,2

0,5

%ED

100

1

2

57

10

203050

352515

55

S [mm]

F [N

]

Page 19: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 34

Stoßende oder ziehende Ausführung

Linear SolenoidH 34

Thrust or pull type

Magnet Hauptkatalog 71 Main catalogue

4

32 9

Ø3

M3

18

Ø12

9

3

49,560±0,5

30

26

M3

20

49,5 2676,9

±0,3

30

26

M3

20

10 M3

Ø12

32 9M3

18

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position

Direction of stroke –––––––>

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 3403/3406 Series H 3403/3406 pull type solenoid

Stoßmagnet H 3443/3446 Series H 3443/3446 thrust type solenoid

Page 20: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 145 gArmature: appr. 25 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 C 36Test voltage: 2500 V (eff)

Force vs. Stroke diagramm F = f (s)

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 145 g

Anker: ca. 25 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 C 36Prüfspannung: 2500 V (eff)

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 42

Stoßende oder ziehende Ausführung

Linear SolenoidH 42

Thrust or pull type

Magnet Hauptkatalog 72 Main catalogue

Bestellformel H 42 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H42

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H4206-F

24 V DC 100% ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 40 25 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

6,224

16 26 39 989

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 100 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 100 cm2, the duty cycle can beextended up to 1.3 x nominal rating

0 1 2 3 4 5 6 7S [mm]

F [N

]

0,5

10,8

23

60 %ED

100

4025401525

10

5

5

10

20

30

50

Page 21: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 42

Stoßende oder ziehende Ausführung

Linear SolenoidH 42

Thrust or pull type

Magnet Hauptkatalog 73 Main catalogue

35

34

M3

25

36

9

Ø10 3

48 ±0,5

17 12

Ø318

4

M3

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

35

34

M3

25

36 25,5±0,3

17 12

M3

18

15

M3

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 4203/4206 Series H 4203/4206 pull type solenoid

Stoßmagnet H 4243/4246 Series H 4243/4246 thrust type solenoid

Page 22: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 320 gArmature: appr. 45 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 C 150Test voltage: 2500 V (eff)Long life expectancy through plasticbobbin armature bearing.The solenoid can also be supplied asspecial specification with service-free DUarmature bearing for maximumdurability.

Force vs. Stroke diagramm F = f (s)

Conical face armatureFlat face armature

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 320 g

Anker: ca. 45 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 C 150Prüfspannung: 2500 V (eff)Hohe Lebensdauer durch Ankerlagerungim Kunststoffspulenkörper.In Sonderausführung ist dieser Magnetauch mit wartungsfreier Ankerlagerung(DU-Lager) für höchste Lebensdauerlieferbar.

Kraft-Weg-Diagramm F = f (s)

KonusankerFlachanker

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetH 62

Stoßende oder ziehende Ausführung

Linear SolenoidH 62

Thrust or pull type

Magnet Hauptkatalog 74 Main catalogue

Bestellformel H 62 06 – F – 24 V DC 100 % ED Order specificationsHubmagnetGröße

H62

Linear solenoidSizes

BauartZugmagnet mit FlachankerZugmagnet mit Konusanker1)

Stoßmagnet mit Flachanker

030643

Design typePull type solenoid with flat face armaturePull type solenoid with conical face armature1)

Thrust type solenoid with flat face armature

AnschlußartStoßmagnet mit Konusanker1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

Nennspannung (Standardspannung)2)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)

46

FA

24

Coil terminalsThrust type solenoid with conical face armature1)

Flying leads (10 cm standard length)Push-on connector (optional)

100 % EDNominal voltage (standard voltage)2)

Perm. duty cycle under air cooled conditions (LK)

H6206-F

24 V DC 100% ED

1) Nur bei Gleichstrom2) Die Magnete sind auf Anfrage bis 230 V DC

lieferbar

1) Only available for DC2) Other voltages are available on request up to

230 V DC

Zul. rel. Einschaltdauer (ED)3) % 100 50 30 15 5 % Perm. duty cycle (ED)3)

Nennaufnahme P 20Anzugszeit (ED)

Wms

1145

20 33 50 13016

Wms

Nominal coil power P 20Actuation time (ED)

3) Bei Montage auf eine Kühlfläche von mindestens 160 cm2 ist die 1,3fache ED zulässig

3) If solenoid is mounted directly onto a flat metal surface of at least 160 cm2, the duty cycle can beextended up to 1.3 x nominal rating

0 5 10 15 20S [mm]

F [N

]

0,81

23458

100 %ED

1005050

3015

5510

20

806050

30

Page 23: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetH 62

Stoßende oder ziehende Ausführung

Linear SolenoidH 62

Thrust or pull type

Magnet Hauptkatalog 75 Main catalogue

Ø13

10

5,5

50

63 ±0,5

4

Ø4

1225

27

M3

44

38

34

27

M3

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

50 30,5±0,5

82,5

44

38

34

27

M3

Ø13

1225

27

M3

10

M4

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Zugmagnet H 6203/6206 Series H 6203/6206 pull type solenoid

Stoßmagnet H 6243/6246 Series H 6243/6246 thrust type solenoid

Page 24: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Magnet Hauptkatalog 76 Main catalogue

Page 25: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Hubmagnete UH, HR, HL

Solenoids Series UH, HR, HL

Page 26: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 18 gArmature: appr. 2.5 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110 C 75Test voltage: 1000 V (eff)

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 18 g

Anker: ca. 2,5 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110 C 75Prüfspannung: 1000 V (eff)

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHR 15

Stoßende Ausführung

Linear SolenoidHR 15

Thrust type

Magnet Hauptkatalog 78 Main catalogue

HR15-F-24VDC

100%ED

Zul. rel. Einschaltdauer (ED)2) % 100 40 20 15 7 % Perm. duty cycle (ED)2)

Nennaufnahme P 20 W 2 5 9 14 25 W Nominal coil power P 202) Bei Montage auf eine Kühlfläche von mindestens

160 cm2 ist die 1,3fache ED zulässig2) If solenoid is mounted directly onto a flat metal

surface of at least 160 cm2, the duty cycle can beextended up to 1.3 x nominal rating

Bestellformel HR 15 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

HR15

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Flachstecker (optional)

FA

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Push-on connector (optional)

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 60 V DC

lieferbar1) Other voltages are available on request up to

60 V DC

0 0,5 1 1,5 2S [mm]

F [N

]

0,1

0,2

0,3

0,5

0,8

10 %ED

100

40

2015

7

1

2

3

5

8

Page 27: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHR 15

Stoßende Ausführung

Linear SolenoidHR 15

Thrust type

Magnet Hauptkatalog 79 Main catalogue

25 9,535

0,42 ±0,2

Ø4,

5

12

7,6±0

,1

145,5M2

10,47

3

1,36

19,05±0,1 2,50,63 Ø1,5

Ø3

Ø1,

5

15

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fully home position–––––––>Direction of stroke

Page 28: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 135 gArmature: appr. 20 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: E (max. permissibletemperature = 120 °C)

Insulation groupaccording to: VDE 0110 C 300Test voltage: 2500 V (eff)

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 135 g

Anker: ca. 20 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: E (Tgrenz = 120 °C)

Isolationsgruppenach: VDE 0110 C 300Prüfspannung: 2500 V (eff)

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

Umkehr-HubmagnetUH

Stoßende und ziehende Ausführung

Two-Directional Linear SolenoidUH

Thrust and pull type

Magnet Hauptkatalog 80 Main catalogue

UH2-L

24 VDC 100%ED

Bestellformel UH 2 – L – 24 V DC 100 % ED Order specificationsHubmagnetBauart

UH2

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Lötpins

FL

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Soldering pins

Zulässige relative Einschaltdauer bei Luftkühlung (LK) 100 % ED Perm. duty cycle under air cooled conditions (LK)1) Die Magnete sind auf Anfrage bis 30 V DC

lieferbar1) Other voltages are available on request up to

30 V DC

0 1 2 3 4S [mm]

F [N

]

1

2

3

5

8

100 %ED

100

50

25

15

510

20

30

50

80

Zul. rel. Einschaltdauer (ED)2) % 100 50 25 15 5 % Perm. duty cycle (ED)2)

Nennaufnahme P 20 W 8,3 16 30 46 115 W Nominal coil power P 202) Bei Montage auf eine Kühlfläche von mindestens

160 cm2 ist die 1,3fache ED zulässig2) If solenoid is mounted directly onto a flat metal

surface of at least 160 cm2, the duty cycle can beextended up to 1.3 x nominal rating

Page 29: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Umkehr-HubmagnetUH

Stoßende und ziehende Ausführung

Two-Directional Linear SolenoidUH

Thrust and pull type

Magnet Hauptkatalog 81 Main catalogue

1 2

51 2023

3043,2

10

M4

Ø2

Ø10 26

15,2

5

14

21

10

3,55,5

M3

1578

52

Maße gelten, wenn System 1 bestromt

<–––––––>Hubrichtung

Dimensions given when system 1 current-carrying<–––––––>Direction of stroke

Page 30: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 75 gArmature: appr. 21 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110/4 KV/3Test voltage: 2.5 KV (eff)

Service-free DU armature bearing formaximum durability.Return spring optional.Observe correct mounting (armatureweight).

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 75 g

Anker: ca. 21 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110/4 KV/3Prüfspannung: 2,5 KV (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.In Sonderausführung mit eingebauterRückholfeder lieferbar (auf Anfrage).Einbaulage (Ankergewicht) beachten.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHL 218

Stoßende und ziehende Ausführung

Linear SolenoidHL 218

Thrust and pull type

Magnet Hauptkatalog 82 Main catalogue

Zul. rel. Einschaltdauer (ED)3) % 100 40 20 10 6 % Perm. duty cycle (ED)3)

Nennaufnahme P 20 W 5 13 25 48 77 W Nominal coil power P 20

3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

Bestellformel HL 218 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

HL218

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckkontakt (2,8 x 0,5 DIN 46247; optional)

FA

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Steckkontakt (2.8 x 0.5 DIN 46247; optional)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)2) 100 % ED Perm. duty cycle under air cooled conditions (LK)2)

1) Andere Spannung bis max. 220 V DC auf Anfrage.2) Andere ED als 100 % ED auf Anfrage.

1) Other voltages up to max. 220 V DC on request.2) Other ED than 100 % ED on request.

0 1 2 3 4 5 6S [mm]

F [N

]

0,1

0,20,3

0,5

30

10

%ED

40

20

106

100

23

58

1

Page 31: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHL 218

Stoßende und ziehende Ausführung

Linear SolenoidHL 218

Thrust and pull type

Magnet Hauptkatalog 83 Main catalogue

20

12

M3

10

Ø3

48

M3

36 37,5

9

48

25,5

Ø10 3

Ø14 25

21

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 32: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 133 gArmature: appr. 35 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110/4 KV/3Test voltage: 2.5 KV (eff)

Service-free DU armature bearing formaximum durability.Return spring optional.Observe correct mounting (armatureweight).

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 133 g

Anker: ca. 35 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110/4 KV/3Prüfspannung: 2,5 KV (eff)

Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.In Sonderausführung mit eingebauterRückholfeder lieferbar (auf Anfrage).Einbaulage (Ankergewicht) beachten.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHL 318

Stoßende und ziehende Ausführung

Linear SolenoidHL 318

Thrust and pull type

Magnet Hauptkatalog 84 Main catalogue

Zul. rel. Einschaltdauer (ED)3) % 100 40 20 10 6 % Perm. duty cycle (ED)3)

Nennaufnahme P 20 W 6,5 14 27 52 84 W Nominal coil power P 20

3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

Bestellformel HL 318 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

HL318

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckkontakt (2,8 x 0,5 DIN 46247; optional)

FA

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Steckkontakt (2.8 x 0.5 DIN 46247; optional)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)2) 100 % ED Perm. duty cycle under air cooled conditions (LK)2)

1) Andere Spannung bis max. 220 V DC auf Anfrage.2) Andere ED als 100 % ED auf Anfrage.

1) Other voltages up to max. 220 V DC on request.2) Other ED than 100 % ED on request.

0 2 4 6 8 10 12S [mm]

F [N

]

0,1

0,2

0,5

30

10

%ED

40

20

20

6

100

1

2

57

Page 33: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHL 318

Stoßende und ziehende Ausführung

Linear SolenoidHL 318

Thrust and pull type

Magnet Hauptkatalog 85 Main catalogue

Ø12 3

Ø17

25,5421243

57

12

Ø3

12

524

M3

M39

3018

1224

M3

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 34: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Weight:Complete solenoid: appr. 390 gArmature: appr. 90 g

Standard:Voltage: 24 V DCFlying leads: 10 cm

Insulation class: B (max. permissibletemperature = 130 °C)

Insulation groupaccording to: VDE 0110/4 KV/3Test voltage: 2.5 KV (eff)Service-free DU armature bearing formaximum durability. Return springoptional. Observe correct mounting(armature weight).

Force vs. Stroke diagramm F = f (s)

Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature

stroke s = 0 corresponds to armature infully home position

Gewicht:Magnet: ca. 390 g

Anker: ca. 90 gStandard:

Spannung: 24 V DCLitze: 10 cm

Isolierstoffklasse: B (Tgrenz = 130 °C)

Isolationsgruppenach: VDE 0110/4 KV/3Prüfspannung: 2,5 KV (eff)Wartungsfreie Ankerlagerung (DU-Lager) für höchste Lebensdauer.In Sonderausführung mit eingebauterRückholfeder lieferbar (auf Anfrage).Einbaulage (Ankergewicht) beachten.

Kraft-Weg-Diagramm F = f (s)

Kraft bei waagerechter Bewegungsrichtung undbei 90 % Nennspannung und betriebswarmerWicklung

Hub s = 0 entspricht dem angezogenen,bestromten Zustand

HubmagnetHL 618

Stoßende und ziehende Ausführung

Linear SolenoidHL 618

Thrust and pull type

Magnet Hauptkatalog 86 Main catalogue

Zul. rel. Einschaltdauer (ED)3) % 100 40 20 10 6 % Perm. duty cycle (ED)3)

Nennaufnahme P 20 W 12 31 50 96 140 W Nominal coil power P 20

3) Bei Montage auf eine Kühlfläche ist eine höhere ED zulässig (bitte anfragen)

3) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)

Bestellformel HL 618 – F – 24 V DC 100 % ED Order specificationsHubmagnetBauart

HL618

Linear solenoidDesign type

Anschlußart

Nennspannung (Standardspannung)1)

Litze (Standardlänge 10 cm)Steckkontakt (6,3 x 0,8 DIN 46247; optional)

FA

24

Coil terminalsFlying leads (10 cm standard length)

Nominal voltage (standard voltage)1)

Steckkontakt (6.3 x 0.8 DIN 46247; optional)

Zulässige relative Einschaltdauer bei Luftkühlung (LK)2) 100 % ED Perm. duty cycle under air cooled conditions (LK)2)

1) Andere Spannung bis max. 220 V DC auf Anfrage.2) Andere ED als 100 % ED auf Anfrage.

1) Other voltages up to max. 220 V DC on request.2) Other ED than 100 % ED on request.

0 5 10 15 20 S [mm]

F [N

]

0,1

0,2

0,5

100 %ED

100

4020

106

1

2

58

10

203050

Page 35: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

HubmagnetHL 618

Stoßende und ziehende Ausführung

Linear SolenoidHL 618

Thrust and pull type

Magnet Hauptkatalog 87 Main catalogue

Ø18 6

Ø25

30,5501652

70

M4

4530

20

38

20

12

30

M4

Ø4

8 M410

Maße im bestromten Zustand

–––––––>Hubrichtung

Dimensions given with armature in fullyhome position–––––––>Direction of stroke

Page 36: Kuhnke Technical Datakuhnke.co.uk/pdf/solenoids/general.pdf · Hubmagnet HM 107 Stoßende oder ziehende Ausführung Linear Solenoid HM 107 Thrust or pull type Magnet Hauptkatalog

Magnet Hauptkatalog 88 Main catalogue