Kitchen Ventilation. Systems Multi Point Ventilation.

49
Kitchen Ventilation
  • date post

    21-Dec-2015
  • Category

    Documents

  • view

    288
  • download

    4

Transcript of Kitchen Ventilation. Systems Multi Point Ventilation.

Page 1: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation

Page 2: Kitchen Ventilation. Systems Multi Point Ventilation.

Systems

Page 3: Kitchen Ventilation. Systems Multi Point Ventilation.

Multi Point Ventilation

Page 4: Kitchen Ventilation. Systems Multi Point Ventilation.

Heat Recovery Ventilator

Page 5: Kitchen Ventilation. Systems Multi Point Ventilation.

Bath Ventilation

Page 6: Kitchen Ventilation. Systems Multi Point Ventilation.

Bathroom Exhaust Fans

Page 7: Kitchen Ventilation. Systems Multi Point Ventilation.

Bathroom Exhaust Fans

CODE for Baths without bathing or spas:

3 SF Glazing ½ Operable or

Baths 75SF or less - 50 CFM Fan or Over 75 SF – Intermittent Ventilation

System 1 air change every 12 minutes or

Continuous Ventilation System at 20 CFM

Page 8: Kitchen Ventilation. Systems Multi Point Ventilation.

Bathroom Exhaust Fans

Baths with bathing and spas

50 CFM Intermittent

or

20 CFM Continuous

Page 9: Kitchen Ventilation. Systems Multi Point Ventilation.

Multi Point Ventilation

Page 10: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation Considerations

Fan Type Propeller Fan – Limited air capacity

and noisy

Axial Fan – Better air movement but still noisy

Centrifugal Blower (Squirrel Cage) The best

Page 11: Kitchen Ventilation. Systems Multi Point Ventilation.

Axial Fan

Page 12: Kitchen Ventilation. Systems Multi Point Ventilation.

Centrifugal Blower

Page 13: Kitchen Ventilation. Systems Multi Point Ventilation.

Sound Levels

Sound is measured in Sones

1-Sone equals the loudness of a pure tone having a frequency of 1,000 hertz at 40 decibels.

Page 14: Kitchen Ventilation. Systems Multi Point Ventilation.

Decibels

0 The softest sound a person can hear with normal hearing

10 normal breathing 20 whispering at 5 feet 30 soft whisper 50 rainfall 60 normal conversation 110 shouting in ear 120 thunder

Page 15: Kitchen Ventilation. Systems Multi Point Ventilation.

Sones

The Home Ventilation Institute sets a limit of 9.0 sones for kitchen fans up to 500 CFM

Reference – A fan with a sone rating of 8.0 sones is twice as loud as one rated at 4.0 sones.

Reference - Refrigerators run at about 1.0 sone.

Page 16: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 17: Kitchen Ventilation. Systems Multi Point Ventilation.

Broan Silent Series 110 cfm .7 Sones

Page 18: Kitchen Ventilation. Systems Multi Point Ventilation.

In-Line Ventilator Fan 110 CFM 1.0 Sones 210 CFM 2.0 Sones

Page 19: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation

Page 20: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Exhaust Fans

CODE100 CFM IntermittentOr25 CFM Continuous

Page 21: Kitchen Ventilation. Systems Multi Point Ventilation.

Multi Point Ventilation

Page 22: Kitchen Ventilation. Systems Multi Point Ventilation.

Vented Hood System

Page 23: Kitchen Ventilation. Systems Multi Point Ventilation.

Recirculating Fan in Microwave Combo

Page 24: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation

Heat Grease Steam Odor Smoke

Page 25: Kitchen Ventilation. Systems Multi Point Ventilation.

Recirculating Range Hood

Page 26: Kitchen Ventilation. Systems Multi Point Ventilation.

Recirculating Ventilation System

This type of system will only remove two Heat Steam

Page 27: Kitchen Ventilation. Systems Multi Point Ventilation.

Downdraft

Page 28: Kitchen Ventilation. Systems Multi Point Ventilation.

Down Draft Ventilation

Page 29: Kitchen Ventilation. Systems Multi Point Ventilation.

Down Draft Ventilation

Page 30: Kitchen Ventilation. Systems Multi Point Ventilation.

Range Hood Installation

Page 31: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 32: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 33: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 34: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 35: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 36: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 37: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 38: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 39: Kitchen Ventilation. Systems Multi Point Ventilation.
Page 40: Kitchen Ventilation. Systems Multi Point Ventilation.

Integral Fan Vented Through Roof

Page 41: Kitchen Ventilation. Systems Multi Point Ventilation.

In Line Fan

Page 42: Kitchen Ventilation. Systems Multi Point Ventilation.

Integral Through Soffit

Page 43: Kitchen Ventilation. Systems Multi Point Ventilation.

Remote Ventilator

Page 44: Kitchen Ventilation. Systems Multi Point Ventilation.

Through Crawlspace

Page 45: Kitchen Ventilation. Systems Multi Point Ventilation.

Down Draft Through Floor

Page 46: Kitchen Ventilation. Systems Multi Point Ventilation.

Down Draft Through Roof

Page 47: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation Considerations

Fan – 250 CFM minimum Ducts Duct run lengths

Interior Fan (power) Keep duct runs as short and straight

as possible. 6” round or 3 ¼” x 10 rectangular

ducts Maximum run = 25’ maximum

Page 48: Kitchen Ventilation. Systems Multi Point Ventilation.

Kitchen Ventilation Considerations

Exterior or In-Line Fan (power) 9” round or 3 ¼” x 14” rectangular

duct Maximum run = 55’ maximum

Page 49: Kitchen Ventilation. Systems Multi Point Ventilation.