Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 1
Kinetic Backup Power for SRCF Bob Hall, Senior Manager, Applications Engineering
Kit Killingsworth, System Sales Engineer
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 2
Agenda» Introductions
» Phil Reese’s Vision
» Who is Active Power Products Product value proposition
» The 415 VAC Data Center One Line Advantages to drive lower PUE Air side economizing
» Technology Flywheel energy storage UPS parallel online topology TCO
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 3Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 3
A Simple Idea and Vision
» The vision of a single man can be a powerful, driving factor
» The vision of Stanford to explore alternative solutions for their data center in both power and cooling
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 4Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 4
Who is Active Power?» Active Power is a leading global manufacturer of
uninterruptible power supply (UPS) systems and modular infrastructure solutions for data centers and other mission critical operations
» Our products and services provide tangible operational advantages through an unmatched combination of power density, reliability, and total cost of ownership
» Chosen by marquee customers around the world, we help them achieve their most forward thinking data center designs
Global Customers
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 5
Company Snapshot» Overview
Founded 1992; IPO 2000 NASDAQ: ACPW 23% average annual growth
since 2005 57 country implementations 3,800+ flywheels shipped 160+ million hours of field
runtime 900 MW power protection
deployed
» Innovation Patented flywheel technology 100+ global patents issued
» Global Operation Centers Austin, Texas (HQ) UK Germany China
» Capabilities 9001:2008 ISO Manufacturing Packaging & Integration Services Design & Project Management Installation & Maintenance
» Partners
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 6Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 6
The Data Center Paradigm Shift to 415 VAC
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 7Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 7
» MV – LV Transformation at UPS 5KV / 415V transformer feeds UPS 415V in/out of UPS Single phase 230V distributed
server racks
» Benefits Transform close to load still allows
benefits of small MV cabling Eliminate PDU transformer cost
and efficiency losses Reduce footprint of many PDUs
The 415V Data Center
1250KVA5KV415VY/230V
PDU A1250KVA
1000 KVA900KW
CDB A 415/230V
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 8Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 8
4MW UPS project, expandable to 8 MW
» Capex Reduced wiring cost by $250,000 dollars (14% of total installation) by
providing MV as close to the load (point of transformation) as possible Eliminate 480:208V transformers in PDUs Reduced MV breakers by $360,000 (11% of total hardware) Reduced UPS / PDU space consumption by 50%
» Opex Improve efficiency by 2-3% by eliminating transformation steps ($65,000
annual savings @ 3MW; $171,000 annual savings @ 8MW) Improve power supply (server) efficiency by 1.5-2% operating at higher
voltage ($42,000 annual savings @ 3MW; $112,000 @ 8MW) Total annual savings of $239,000 @ 3MW; $635,000 @ 8MW) Lower losses = less cooling required
Major Savings in MV / 415V Distribution
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 9
SRCF Abbreviated SLD
G
2.5MW12.47kV
1000kVA/900kW
Active PowerFlywheel
UPS
1000kVA/900kW
Active PowerFlywheel
UPS
1000kVA/900kW
Active PowerFlywheel
UPS
G
2.5MW12.47kV
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 10Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 10
PUE – Power Usage Effectiveness
How PUE is changing the topologies, functions, and characteristics of UPS in the data center space
10
PUE = Total Facility PowerIT Equipment Power
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 11Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 11
More on PUE» Power usage effectiveness (PUE) is a measure of how efficiently a
data center uses its power; specifically, how much of the power is actually used by the computing equipment
» PUE is the inverse of data center infrastructure efficiency (DCIE).
» An ideal PUE is 1.0
» Anything that isn't considered a computing device in a data center (i.e., lighting, cooling, etc.) falls into the category of facility power usage
11
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 12Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 12
Value Propositions to Drive Lower PUE» Medium Voltage Application
» Highly Efficient, Up to ~98%
» Minimal if any AC needed for the UPS, will operate up to 104 F without de-rating
» Half the heat rejection of legacy UPS
» No special room needed – less construction cost
» Power Dense – twice the power in half the space
» Lower overall maintenance cost
» Air side economizing for facility
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 13Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 13
Utility Savings of Highly Efficient UPS
Traditional Double Conversion UPS
$ / kW/hr. $ 0.10 0.1 X 0.06
X 2400 X 8760 = $ 134,194
kW load 2400 0.94
Traditional UPS Efficiency 94% Active Power CleanSource UPS
Active Power UPS Efficiency 97% 0.1 X 0.03X 2400 X 8760 = $ 65,022
0.97
Utility savings per year: $ 69,172
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 14
UPS Technology and Product Overview to Achieve Lowest PUE and TCO
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 15Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 15
Power Dense and Reliable» Modular * Scalable * Flexible» Field Upgradeable * Grows with IT and Business Needs» Paralleling Capability for Multi-Megawatt Solutions
300 kVA600 kVA 900 kVA
1200 kVA
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 16Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 16
CleanSource UPS Multi-Module Systems – Z Series
Input Isolation SwitchesSystem Cabinet
Output Isolation SwitchesSystem Cabinet
Dual Input OptionMBP External Only
DC
DCAC
ACDC
DCAC
AC
MMS One-line
Built in:• Maintainability• Scalability• Redundancy
DC
DCAC
ACDC
DCAC
AC
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 17
Flywheel UPS Parallel Online Architecture
Static Bypass
Harmonic Current• Conditions power to load• Voltage regulation• Power Factor correction• Harmonic cancellation
• Low input current distortion• Overload capability• Unlimited cycling
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 18Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 18
Total Cost of Ownership (TCO) » Lower installation costs
Flywheel and communication cables as well as wire way provided
» Efficiency – up to 98%
» Minimal cooling requirements Less heat rejection
» Small footprint, power dense
» Low maintenance costs
» No battery cooling required
» No battery changes
» A KNOWN Energy Source
Active Power Proprietary & Confidential – © 2013 Active Power, Inc. 19