Keysight Standards Lab Calibration Ensure the ongoing high accuracy of the devices you test SOLUTIONS BRIEF

Transcript of Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as...

Page 1: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Keysight Standards Lab Calibration Ensure the ongoing high accuracy of the devices you test

S O L U T I O N S B R I E F

Page 2: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 2Find us at www.keysight.com

Keysight Standards Lab CapabilitiesKeysight can now calibrate over 1000 lab standards

Electro-optics RF, microwave, millimeter wave Dimensional /optical Physical Electrical

– Attenuation – Color temperature – Fiber optic power – Laser power – Luminous intensity – Wavelength

– Antenna gain – Attenuation – Frequency – Impedance – Impedance, reflection coefficient – Linear antenna probe – On-axis polarization

– Gain, axial ratio, tilt angle – Main component pattern

– Amplitude, phase – Noise temperature, excess noise

ratio (ENR) – Phase noise – Phase shift power

– Angle – Flatness – Length – Straightness/

parallelism – Thread lead

– Air velocity – Density – Dew/frost point – Force – Gas flow rate – Helium leak – Humidity – Mass – Pressure – Temperature – Torque – Vacuum

– AC-DC difference – AC current – AC voltage – Capacitance – DC ratio – DC resistance – DC voltage – Inductance – Phase angle – Ratio, AC current – Ratio, AC voltage – Sinusoidal/shock

sensitivity

Offering Very Low Measurement Uncertainty

We compare your standards to a reference standard which has been directly calibrated by a National Metrology Institute (NMI) or primary standard. Measurement accuracy is the foundation for crucial decisions your organization makes about the devices you test. The ability to ensure the ongoing precision of your in-house standards depends on calibrations that provide even lower measurement uncertainty. Lowering measurement uncertainty is the only way to decrease both false accepts and false rejects.

Primary standard calorimeter

Figure 1. Uncertainties increase with each step removed from primary standards.

(Cover image: Antenna test station)

Primary SI standard @ NMI

Lab reference standard

Standards lab calibration

Keysight cal + uncertainties

Normal use case

11

22

33

44

00 0.002%

0.01%

0.07%

1%

10%

Page 3: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 3Find us at www.keysight.com

Standards Lab Calibration: RF, Microwave, Millimeter Wave

The Keysight micrometer and millimeter wavelength laboratory is equipped to perform calibrations on Keysight and non-Keysight network analyzer calibration kits, mixers, noise sources, downconverters, couplers, waveguide detectors, adapters, power sensors, attenuators, antennas and electric field meters up to 110 GHz. We support waveguide, 1.85 mm, 2.4 mm, SMA, 2.92 mm and 3.5 mm connections. We support WR-42, WR-28, WR-22, WR-15, WR-10 dimensions for waveguides.

AntennasThe Keysight metrology and calibration laboratory can very accurately calibrate antenna gain and antenna factor on rectangular gain horns and satellite dishes from 200 MHz to 220 GHz with measurement uncertainties as low as 0.15 dB.

AttenuationKeysight can very accurately measure attenuators up to 4 GHz. Our measuring station has uncertainty ranging from 0.003 dB to 0.008 dB for 1 dB steps and 0.009 dB to 0.11 dB for 10 dB steps.

Figure 2. Reference gain horns calibrated by National Physics Lab (UK)

Figure 3. Standards level power sensor test station

Figure 4. Reference coupler mounts calibrated by National Physics Lab (UK)

Page 4: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 4Find us at www.keysight.com

Standards Lab Calibration: Electro-Optics

Keysight metrology and calibration laboratories feature an electro-optical laboratory which can calibrate your entire optical test bench. The lab features test stations for OTDR with 2.3 km and 11 km wire lengths measured from the National Physics Laboratory in the United Kingdom. Additionally, we feature a recirculating optical length loop from NPL which enables multi-mode OTDR measurements. Keysight uses a NIST hydrogen cyanide H13C14N absorption reference primary standard for measuring wavelength between 1530 nm and 1565 nm. Additional standards extend the measurement range for single mode and multi-mode meters. We also have more standards to measure fiber optic power, attenuation, return loss and polarization dependence loss. Keysight’s custom illuminance meter measurement station features a NIST luminous intensity lamp for lowest measurement uncertainty. Our in house NIST tungsten strip lamp calibrates optical pyrometers from 800 °C to 2300 °C. Keysight designed a custom laser power and energy measurement setup with NIST calibrated calorimeters to achieve measurement uncertainties of ±1.7% for laser power and ±3.8% for laser energy.

Figure 5. NPL OTDR distance scale artifact

Figure 6. NIST hydrogen cyanide absorption reference primary standard

Figure 7. NIST tungsten strip lamp at the pyrometer calibration station

Figure 8. Custom laser power and energy test station

Figure 9. Custom luminosity meter test station

Page 5: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 5Find us at www.keysight.com

Standards Lab Calibration: Dimensional

The Keysight metrology and calibration laboratory for dimensional parameters includes one dimensional, two dimensional and three dimensional measurements. NIST calibrates our gage blocks, laser interferometer and thread wires.

We can measure gage blocks from 0.5 to 100 mm in length with an accuracy of (0.05 + 0.0015L) µm. The NIST calibrated gage blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers.

Our laser interferometer is used to make non-contact length measurements up to 60 inches. The length measurement uncertainty is (10 + 10L) µin up to 12 inches and (150 + 12L) µin from 12 to 60 inches. The angular accuracy of the laser interferometer also measures autocollimators and angle generators up to 1000 arc s. The measurement uncertainty for autocollimators measurements is (0.3% + 0.4) arc s and 0.27% arc s for angle generators. Electronic levels, glass scales and scale bars are other typical items calibrated using the laser interferometer.

Keysight’s thread measures thread plug gages and thread ring gages up to 1 inch. Our mechanical comparator allows the calibration of other thread measuring wires.

Figure 10. Reference gage blocks calibrated by NIST

Figure 12. Custom vacuum chamber for measurements as low as 10-7 torr

Standards Lab Calibration: Physical

Vacuum & pressureThe Keysight metrology and calibration laboratories have a vacuum lab and a pressure lab. The vacuum lab has two custom designed vacuum chambers which allow for measurements as low as 10-7 torr up to 10-4 torr range with uncertainties varying from ±8.3% to ±2.7%. The vacuum lab can measure ionization gages, inverted magnetron gages, cold cathode gages, residual drag gages, thermocouple and capacitance manometer types. The pressure lab can measure from 0.2 PSIA to 20,000 PSIG for oil and 15,000 PSIG for air using standard piston gages and weights. The uncertainty for our pressure measurements ranges between 0.0036% and 0.0044%.

Figure 11. Automatic length comparator

Page 6: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 6Find us at www.keysight.com

Standards Lab Calibration: Physical

Torque, force and massThe Keysight metrology and calibration laboratory for torque, force, and mass has a set of class 1 weights calibrated directly by NIST. We have weights and electronic balances for both the metric and U.S. customary scale. The metric weights measure from 1 mg to 5 kg with uncertainties ranging from 0.012 mg to 33 mg. Mass measurements on the U.S. customary system range from (5 to 50) lb with uncertainties from (6.3 * 10-5) lb to (5.9 * 10-4) lb.Keysight can measure force from 0 to 100,000 lbf with uncertainties ranging from 0.045% on the low end to 220 lbf on the high end. Our torque traceability goes directly through our metrology and calibration laboratories for mass and length. This allows us to measure torque transducers from 10 in-oz to 2000 ft-lbs with a measurement uncertainty of 0.03%. We are also able to measure torque wrenches and screwdrivers from 20 in-oz to 2000 ft-lbs with an accuracy of 0.7%.

Figure 15. Torque transducer testing station

Figure 13. Temperature baths

TemperatureKeysight metrology and calibration laboratories can very accurately measure temperature. We have five fixed point temperature baths to measure SPRTs and PRTs. Our temperature baths provide accurate measurements at the temperatures for the triple point of water, triple point of mercury, melting point of nitrogen, melting point of tin and zinc. Our oven measures temperature from -80 °C up to 1000 °C on thermocouples and thermometers. The thermodynamic lab is equipped with dew point and frost point generators from -80 °C to +10 °C. The lab’s humidity generator measures humidity devices with a range between 20% and 85% RH.

Figure 14. Automated torque wrench test station

Page 7: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

Page 7Find us at www.keysight.com

Standards Lab Calibration: Time & Frequency

Time and frequencyThe Keysight metrology and calibration laboratory uses a NIST time measurement and analysis service (TMAS) to measure time and frequency standards. The TMAS system uses a GPS steered rubidium frequency standard which synchronizes every ten minutes with eight GPS satellites. The GPS systems allow Keysight to measure a 5 or 10 MHz frequency standards for frequency offset and stability with average accuracy is better than 1 * 10-15.

Standards Lab Calibration: Electrical

DC and low frequencyThe Keysight metrology and calibration DC and low frequency laboratories service all of Keysight’s working and transfer standards for DC and low frequency. This includes Keysight and non-Keysight thermal voltage converters, resistance standards, capacitance standards, voltmeters, inductors, LCR meters, capacitance bridges and voltmeter calibrators. This lab features a Josephson junction primary standard for the DC volt, which we use as our traceability source. The Keysight ohm is kept in a mineral oil bath to minimize impact of temperature variation for resistance and current measurements. This bath allow us to create DC current with uncertainties as low as 1.0 µA/A. DC resistance measurements have measurement uncertainties as low as 0.20 µΩ/Ω.

Figure 17. NIST TMAS setup for time and frequency measurements.

Figure 18. Keysight’s Josephson junction quantum volt instrinsic standard

Figure 16. Keysight’s primary ohms standard and oil bath

Page 8: Keysight Standards Lab Calibration · blocks are also used to calibrate hand tools such as calipers, height gages, digital indicators, dial indicators and gage amplifiers. Our laser

This information is subject to change without notice. © Keysight Technologies, 2016 - 2019, Published in USA, January 24, 2019, 5992-1764ENA1

Page 8Find us at www.keysight.com

Learn more at: www.keysight.comFor more information on Keysight Technologies’ products, applications or services,

please contact your local Keysight office. The complete list is available at:

www.keysight.com/find/contactus

Standards Lab Calibration: Electrical

Voltmeters and voltmeter calibratorsThe Keysight Loveland metrology and calibration DC and low frequency laboratory was built specifically for the 3458A digital multimeter. We provide intrinsic and primary level standards calibrations to OEM identical process or better for voltmeters and voltmeter calibrators.

High voltage, current, and resistanceThe DC and low frequency laboratory can make high voltage, current, and resistance measurements. PTB (National Metrology Institute of Germany) voltage dividers allow high voltage measurements from 2 to 60 kV with measurement uncertainties ranging from 11 µv/V to 28 µv/V. Keysight can measure high resistance up to 10 PΩ. The high resistance measurement uncertainties range from 0.8 mΩ/Ω to 0.12 Ω/Ω. We have capability to measure current shunts up to 400 A.

Figure 20. Fluke 5700A and Datron 4700A voltmeter calibrator test station

Figure 19. PTB high voltage divider

To learn more about Keysight’s Standards Lab Calibrations visit:www.keysight.com/find/standardslab