KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The...

18
KESO KEK i-pin Integral part of PB.01.013 KESO AccessPoint documentation 1 Product description .............................................................. 3 2 System and hardware requirements............................... 3 3 Incorrect PIN code entry ..................................................... 3 4 Ordering information........................................................... 4 5 Technical data ......................................................................... 5 6 KESO KEK i-pin layout and dimensions .......................... 6 7 Connection diagram............................................................. 8 8 Installing KESO KEK i-pin .................................................. 11 9 Programming ....................................................................... 12 10 Access ..................................................................................... 14 11 LED and signal behaviour ................................................. 15 12 Accessories............................................................................ 15 13 Maintenance / Care / Repair ............................................ 16 14 Notes ....................................................................................... 16 Issue date: 26.07.2011 Version: 001 ASSA ABLOY, the global leader in door opening solutions

Transcript of KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The...

Page 1: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

G

ASSA ABLOY is the global leader in door opening solutions.

KESO KEK i-pin Integral part of PB.01.013 KESO AccessPoint documentation

1 Product description..............................................................3 2 System and hardware requirements...............................3 3 Incorrect PIN code entry .....................................................3 4 Ordering information...........................................................4 5 Technical data.........................................................................5 6 KESO KEK i-pin layout and dimensions ..........................6 7 Connection diagram.............................................................8 8 Installing KESO KEK i-pin .................................................. 11 9 Programming ....................................................................... 12 10 Access ..................................................................................... 14 11 LED and signal behaviour................................................. 15 12 Accessories............................................................................ 15 13 Maintenance / Care / Repair ............................................ 16 14 Notes....................................................................................... 16

Issue date: 26.07.2011Version: 001

ASSA ABLOY,the global leader in door opening solutions

Page 2: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin
Page 3: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 3 of 18 pages

1 Product description KESO KEK i-pin meets the need for security and flexibility in modern buildings perfectly. KESO KEK i-pin, the new supplementary product for KESO AccessPoint, is the ideal solution for building envelopes, IT rooms, and access entry on individual floors. Depending on the individual circumstances, KESO KEK i-pin can be used on its own or in conjunction with the KESO KEK i-reader. PIN codes are issued electronically using KESO management software k-entry®.

1.1 Important notes on this documentation This document is an integral part of KESO AccessPoint PB.01.013 documentation. It contains important information on product handling and initial operation. For this reason, you should familiarise yourself with its content and, in particular, observe the instructions on safe handling, operation, and installation. The figures or graphics shown may differ from the supplied components. We reserve the right to make changes to reflect technical advancements. The manual is not covered by an update service.

2 System and hardware requirements

2.1 KESO management software k-entry® Standard • Version 5.0.6.4 or higher

2.1.1 Supplementary licence for KESO KEK i-pin • Article no.: K.731 / The MID is needed to issue the supplementary licence.

2.2 KESO KEK Programmer PPG V2 • Firmware V1.02 Pro Rev and higher. T

2.3 KESO AccessPoint ET or SA • Firmware 04.01.01 and higher

2.4 KESO KEK i-reader surface/flush mount K.548 / K.549 / K.550 (grey signet) • Firmware V01.19 and above (deliveries as from February 2011)

3 Incorrect PIN code entry The KESO KEK i-pin keypad will be blocked for the following time intervals if the incorrect code is entered: • After the third attempt: 30 seconds • After the fourth attempt: 60 seconds • After the fifth attempt: 300 seconds • After the sixth attempt: 600 seconds

WARNING: If a KESO KEK i-reader and a KESO KEK i-pin are used together, only the PIN code for the identification medium is blocked. Other access authorisations are not blocked. The blocking interval on the KESO KEK i-pin keypad is eliminated if another identification medium with a valid PIN code is used to open the access. The blocking intervals are not displayed on the KESO KEK i-pin keypad for security reasons.

Page 4: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 4 of 18 pages

4 Ordering information

The product models that we market comply with regulations under European directives. You will find the terminal assignment in the packaging (Document BA.01.034) or in this documentation from Section 7 onwards.

4.1 KESO KEK i-pin / Feller EDIZIO due model

Item No. Description K.557/UP KESO KEK i-pin

Packaging contents: One KESO KEK i-pin keypad One KESO KEK i-pin keypad circuit board One EDIZIO due cover frame Four black expanding rivets One set of installation instructions

4.2 KESO KEK i-pin / flush-mount model for outdoor areas

Item No. Description K.558/UP KESO KEK i-pin

Packaging contents: One KESO KEK i-pin keypad One KESO KEK i-pin keypad circuit board One NUP installation frame, white, with expanded rubber seal Four black expanding rivets One set of installation instructions

4.3 KESO KEK i-pin / surface-mount model for outdoor areas

Item No. Description K.558/AP KESO KEK i-pin

Packaging contents: One KESO KEK i-pin keypad One KESO KEK i-pin keypad circuit board One empty casing, surface-mount, with PG gland Four black expanding rivets One set of installation instructions

Page 5: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 5 of 18 pages

5 Technical data

5.1 KESO KEK i-pin / Feller EDIZIO due model Size: 87x87x40mm (LxWxH) Colour: White Power supply: Regulated power supply 8 to 24V DC / 200mA Protection rating: IP20 Operating temperature: -20°C to +70°C Storage temperature: -20°C to +70°C Humidity: 10 to 95% (non-condensing) Product service life: 10 years, excluding keypad wear

5.2 KESO KEK i-pin / model for outdoor areas Size, flush-mount: 87x87x40mm (LxWxH) Colour: White Mounting: Installation frame, white, with expanded rubber seal Power supply: Regulated power supply 8 to 24V DC / 200mA Protection rating: IP55 Operating temperature: -20°C to +70°C Storage temperature: -20°C to +70°C Humidity: 10 to 95% (non-condensing) Product service life: 10 years, excluding keypad wear

5.3 KESO KEK i-pin / model for outdoor areas Size, surface-mount: 87x87x65mm (LxWxH) Dimensions without PG gland Colour: White Power supply: Regulated power supply 8 to 24V DC / 200mA Protection rating: IP55 Operating temperature: -20°C to +70°C Storage temperature: -20°C to +70°C Humidity: 10 to 95% (non-condensing) Product service life: 10 years, excluding keypad wear

Page 6: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 6 of 18 pages

6 KESO KEK i-pin layout and dimensions

6.1 KESO KEK i-pin / Feller EDIZIO due model

6.1.1 Rear view of KESO KEK i-pin

6.1.2 Front view of KESO KEK i-pin

6.1.3 Side view of KESO KEK i-pin

X2 / PIN 1: Power supply AC/DC minus PIN 2: Power supply AC/DC plus

JP1 / No function – Jumper to 2-3

X1 / PIN 5: RS485 Connection B PIN 6: RS485 Connection A

# / Hash key for code completion

LED / red yellow green

DIP Switch / 1 – OFF 2 – ON

3-8 OFF

X2 / PIN 1: Power supply AC/DC minus PIN 2: Power supply AC/DC plus

X1 / PIN 5: RS485 Connection B PIN 6: RS485 Connection A

Page 7: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 7 of 18 pages

6.2 KESO KEK i-pin / model for outdoor areas

6.2.1 Rear view of KESO KEK i-pin

6.2.2 Front view of KESO KEK i-pin

6.2.3 Side view of KESO KEK i-pin

X2 / PIN 1: Power supply AC/DC minus PIN 2: Power supply AC/DC plus

JP1 / No function – Jumper to 2-3

X1 / PIN 5: RS485 Connection B PIN 6: RS485 Connection A

# / Hash key for code completion

LED / red yellow green

DIP Switch / 1 – OFF 2 - ON 3-8 OFF

X2 / PIN 1: Power supply AC/DC minus PIN 2: Power supply AC/DC plus

X1 / PIN 5: RS485 Connection B PIN 6: RS485 Connection A

Page 8: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 8 of 18 pages

7 Connection diagram

The power supply must be switched off during any wiring work. All inputs and outputs are designed for 12/24 volts. Never connect to a mains voltage (115/230 Volt) Risk of fatal injury

7.1 Overview of KESO AccessPoint See Document PB.01.013 KESO AccessPoint for further descriptions of connections

IMPORTANT: The KESO AccessPoint electronics must contain firmware version 04.01.01 or higher to actuate KESO KEK i-pin.

7.2 KESO cable, 4-wire Cable for wiring KESO KEK i-reader or KESO KEK i-pin.

Item No. Description K.551/01 Serial, 10m, twisted pair K.551/05 Serial, 50m, twisted pair K.551/10 Serial, 100m, twisted pair

Cable: T+T G51 PVC 2x2x0.6 gr Cable colours: Yellow & white – twisted Blue & white – twisted Diameter: 5.6mm Cable head: Raw/unfinished

WARNING: The cable is designed for fixed installations and must not be used for moving cable transitions.

KESO KEK i-reader and/or KESO KEK i-pin

Page 9: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 9 of 18 pages

7.3 Connection diagram – KESO KEK i-pin and KESO AccessPoint

KESO AccessPoint “READER PIN A” KESO KEK i-pin “X1 – PIN 6” KESO AccessPoint “READER PIN B” KESO KEK i-pin “X1 – PIN 5” KESO AccessPoint “READER PIN –” KESO KEK i-pin “X2 – PIN 1” KESO AccessPoint “READER PIN +” KESO KEK i-pin “X2 – PIN 2”

Symbol for twisted wire pairs

Page 10: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 10 of 18 pages

7.4 Connection diagram – KESO KEK i-pin and KESO KEK i-reader to KESO AccessPoint

NOTE: Observe information on maintenance in Section 8 .

Wire KESO KEK i-reader and KESO KEK i-pin in series. Do not use branch connection lines. The total cable length should not be more than 100 m.

KESO AccessPoint “READER PIN A” KEK i-reader “PIN A” KEK i-pin “X1 - PIN 6” KESO AccessPoint “READER PIN B” KEK i-reader “PIN B” KEK i-pin “X1 - PIN 5” KESO AccessPoint “READER PIN -” KEK i-reader “PIN -” KEK i-pin “X2 - PIN 1” KESO AccessPoint “READER PIN +” KEK i-reader “PIN +” KEK i-pin “X2 - PIN 2”

NOTE: Ensure that the KESO KEK i-reader switch setting is placed at Pos. 2.

JP2JP3

JP1

X1

X2

A

B

-

+

4 < > 2

DIP-Switch

ON

D

IP

1 2 3

4

5 6 7

8 OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

Symbol for twistedwire pairs

Page 11: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 11 of 18 pages

8 Installing KESO KEK i-pin

Note on installation: KESO KEK i-pin and KESO KEK i-reader must not be installed together in a Feller EDIZIO due dual cover frame. The two devices must be installed separately in a single box each.

8.1 KESO KEK i-pin / Feller EDIZIO due model 1. Remove front printed labelling (with film) from EDI frame 2. Wire KESO KEK i-pin, including power supply 3. Mount printed labelling with 4 countersink screws onto the wall or

surface-mount/flush-mount box 4. Insert the four black expanding rivets into the printed labelling 5. Mount EDIZIO due frame on top 6. Carefully place front printed labelling on top, ensuring that the four guide

bolts and the 12-pin connector fit correctly.

8.2 KESO KEK i-pin / model for outdoor areas 1. Wire KESO KEK i-pin, including power supply 2. Mount printed labelling with 4 countersink screws onto the wall or

surface-mount/flush-mount box 3. Insert the four black expanding rivets into the printed labelling 4. Carefully place front printed labelling on top, ensuring that the four guide

bolts and the 12-pin connector fit correctly. 5. Fasten the front printed labelling with the four screws

Page 12: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 12 of 18 pages

9 Programming

To programme the KESO KEK i-pin keypad, you need at least KESO management software k-entry® Standard with a supplementary PIN licence and the KESO KEK Programmer PPG V2. The PIN code can only be generated and issued in KESO management software k-entry® using an account with administrator rights. PIN authorisations can only be issued on the Door and Pin screen if the PIN option is activated for the door in question (see Section 9.1). If the PIN option is not available or not activated in the device properties, the doors or devices concerned are displayed in grey on the PIN screen. It is also not possible to activate the PIN authorisation on the Door screen or the PIN Code Register. In addition to the Key Register, there is also a PIN Code Register available on the Users screen. A selected user can thus see all information on this screen.

NOTE: The NOK function cannot be used in conjunction with PIN code usage.

9.1 Device properties You can configure the KESO AccessPoint in ‘Properties’ to determine whether a KESO KEK i-pin keypad is used or not.

If the option "PIN keypad available“ is activated and the option "Use PIN only“ deactivated in the KEK Register, you also need to select a PIN time window in the "Time" Register. If PIN time window is selected, the system first needs to be batched. Afterwards the PIN code can be entered and then completed by pressing the # key.

If the KESO KEK i-pin keypad is to be used together with the KESO KEK i-reader, you need to select "Use PIN keypad“. A time window also needs to be selected under "Also use PIN" in the "Time" register.

If the KESO KEK i-pin keypad is to be used on its own, you need to select "Use PIN only“.

The office function can only be operated in KESO KEK i-reader mode. This means that the office function can only be activated in time windows in which the PIN code keypad is inactive

Page 13: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 13 of 18 pages

9.2 Generating PIN codes You can issue codes on the PIN Code screen.

PIN Code Properties dialogue box

New or additional PIN codes are produced using the right-hand mouse button and "Generate new PIN Codes ...".

Number of PIN codes to be generated. Minimum and maximum PIN code length. This activation means that leading zeros may be put in front of the PIN code. PIN code name.

The sequential numbering and code issue is automatic for "Generate PIN codes". The individual names and PIN codes can be modified in properties any time.

PIN code name. Current PIN code for this name. Group membership. Status (depot, issued). PIN code owner/holder.

PIN code screen.

Page 14: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 14 of 18 pages

9.3 Issuing/withdrawing PIN code to/from holder PIN code status can be modified in the PIN Code Properties dialog box.

NOTE: Only one PIN code can be issued per person.

9.4 PIN code authorisations PIN code/holder authorisations (“PIN Codes” register) are allocated on the Door and Pin screen in the same way as keys to individual door positions.

10 Access To gain access, users need to press the # key after they have entered the code.

10.1 PIN code - batch mode In order to enter the PIN code, a valid identification medium must first be held in front of the KESO KEK i-reader.

NOTE: In this mode, each PIN code authorisation is considered a 24-hour authorisation. The identification medium’s time window is decisive in this respect.

10.2 PIN code mode This mode allows the PIN code to be entered directly on the KESO KEK i-pin keypad.

Select "PIN codes" register. Mark required door. Select PIN codes and drag and drop at the door position. Authorise PIN codes/holders.

The following statuses can be selected:• In key safe • Issued

Page 15: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 15 of 18 pages

11 LED and signal behaviour

When the KESO KEK i-pin is put into operation, the LEDs will light up in the following order: red, orange, green. When start mode is completed, the green LED will flash briefly followed by the orange LED and an audible signal will sound twice.

NOTE: The blocking intervals are not displayed on the KESO KEK i-pin keypad for security reasons. If an online electronic system is disengaged due to a blocking interval, it can be released using the ‘Restart electronic system …’ context menu.

11.1 PIN code - batch mode The KESO KEK i-reader always signals release, office functions, permanently open mode or non-authorisation. KESO KEK i-pin begins to flash red and green immediately after it has been batched. This means that the PIN code can now be entered as appropriate.

11.2 PIN code mode KESO KEK i-reader always signals release and the permanently open mode as appropriate.

12 Accessories

12.1 KESO surface mount casing for Feller EDIZIO model .

Item No. Description 1385AP-ED-01-WS 12.1.1 Single casing for Feller

EDIZIO due

NOTE: See ‘Security and fitting products' price list for other models.

12.2 Surface-mount empty casing

Item No. Description K.514 12.2.1 Empty casing with M20

leading-in tube Dimensions: 87x87x54mm (LxWxH) (Including labelled cover for KESO KEK i-reader. This is not needed)

12.3 Mounting plate for flush mount

Item No. Description V.000/52/43 12.3.1 NUP installation frame,

white, 12.3.2 with expanded rubber seal. Dimensions: 87x87x12mm (LxWxH)

Page 16: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO KEK i-pin / KESO AccessPoint

KESO AG, 07/2011 Subject to changes Pages 16 of 18 pages

13 Maintenance / Care / Repair

The KESO KEK i-pin keypad does not require maintenance. Use a slightly damp, soft, lint-free cloth to clean the outside surface of the KESO KEK i-pin keypad. Ensure that no damp gets through the openings and inside the KESO KEK i-pin keypad. Never spray liquids directly onto the KESO KEK i-pin keypad. Do not use any sprays, solvents or scouring agents. If repairs are required, the KESO KEK i-pin keypad must be sent back to KESO AG in its original packing.

14 Notes

Page 17: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin
Page 18: KESO KEK i-pin - assaabloyopeningsolutions.ch Schweiz/Downl… · EDIZIO due dual cover frame. The two devices must be installed separately in a single box each. 8.1 KESO KEK i-pin

KESO AG Sicherheitssysteme Untere Schwandenstrasse 22 8805 Richterswil Swizterland Telephone +41 44 787 34 34 Fax +41 44 787 35 35 Email [email protected] Internet www.keso.com KESO GmbH KESO SA Maurerstrasse 6 Succursale Suisse romande 21244 Buchholz i.d.N Zl. Le Trési 9B Germany 1028 Préverenges Switzerland Telephone +49 4181 924-0 Telephone +41 21 811 29 29 Fax +49 4181 924-100 Fax +41 21 811 29 00 Email [email protected] Email [email protected] Internet www.keso.de Internet www.keso.com

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.

PB_0

1_02

1_en

_KES

O_K

EK_i

-pin

_V00

1.do

c