Kā ietaupīt enerģiju, izmantojot jumtus – ieteikumi jumtu renovācijai

28
1 Time to save energy by PITCHED ROOF with KNAUF INSULATION Riga 08.11.2012r 2 07/11/2012 Heat loss in the house Roof is like : ¾ Cup during winter ¾ Hat during summer We may lose even 30% heat through wrongly insulated roof 25 – 30 %

description

2012.gada 8.novembra seminārā "Aktualitātes mājokļu renovācijā Vācijā, Polijā un Latvijā" Eva Kosmala (Knauf Insulation”, Polija”) pastāstīja par to, kā ietaupīt enerģiju, izmantojot jumtus/ieteikumi jumtu renovācijai

Transcript of Kā ietaupīt enerģiju, izmantojot jumtus – ieteikumi jumtu renovācijai

  • 1. Time to save energy by PITCHED ROOF with KNAUF INSULATIONRiga08.11.2012r Heat loss in the houseRoof is like : Cup during winter 25 30 % Hat during summer We may lose even 30% heat through wrongly insulated roof 07/11/2012 2 1
  • 2. Pitched Roof Thermal Insulation 07/11/2012 3 Pitched Roof Thermal InsulationIn the case of usable attic we can install the insulation in the following ways:between the raftersbetween and under the rafters KI PITCHED ROOF SYSTEMSabove the raftersThe thickness of thermal insulation and its placement depends on: required thermal insulation performance, roof pitch, rafter height, type of roof cladding used, type of roof membrane used. 07/11/2012 4 2
  • 3. Two layers Pitched Roof KI Systems 07/11/2012 5 Where put vapour barrier ?A / Pitched roof ridge sectional view, with vapour barrierinstalled between two thermal insulation layers. The ratio B / Pitched roof ridge sectional view with vapour barrierof the insulation between the rafters (above the vapour installed under the thermal insulation layersbarrier) to the insulation under the rafters (below thevapour barrier) should be 5:1. Recommended arrangement for KI ROOFS 07/11/2012 6 3
  • 4. kind of vapour barrier vapor permeability equivalent diffusion [g/m2/24h] thickness of air layer Sd [m] Vapor barrier < 0,01 100 1000 (with metal or bitumen) Vapor retarder 0,2- 0,5 20 60 (PE foil thickness 0,15 0,2 mm) Vapor regulator 4 -700 0,1 -10 (carrier from PP fiber) 07/11/2012 7 Can GMW be installed at the entire height of the rafters?In the case of using the highly water vapourpermeable roof membrane - the thermal insulationin form of the GMW with Ecose Technology canbe installed at the entire height of the rafter.When full hard boarding or low permeable roofmembrane is installed over the thermal insulationof the GMW with Ecose Technology then aventilation gap of ca. 2.5 cm must be left under theboarding. 07/11/2012 8 4
  • 5. Takie mamy przepisy prawne Thermal requirements for pitched roof Umax W/m2K Umax W/m2K local law Ecofys Estonia 0,16 0,14 0,17 Latvia 0,20 0,15 0,18 Lithuania 0,18 0,16 0,18 Remember !!!! U designe= PITCHED ROOF SYSTEMS KI U max 07/11/2012 9Optimum U-value for roofs based onECOFYS report WEO reference peak price scenario Latvia U= 0,15 W/m2K U= 0,18 W/m2K www.eurima.org 07/11/2012 10 5
  • 6. Premium Roof - Classic + TP 115 + Optimal insulation its the most effective method of saving energy Haw to calculate and check U-value ?You can use the tools KI-DESIGNER : KI-Therm 07/11/2012 12 6
  • 7. Haw to calculate and check U-value ?You can use the tools KI-DESIGNER : KI-Therm EN 6946 07/11/2012 13 Haw to calculate and check U-value ?You can use the tools KI-DESIGNER : KI-Therm EPD EN 15804 07/11/2012 14 7
  • 8. Popular Roof - mineral wool only between rafters This is photo from inside of building Yellow colour means insufficient insulation thats way we read the colour opposite: there should be blue colour blue and green rafters mean frost penetration 07/11/2012 15 Haw the distance between rafters influence on the U-value one layer insulation influence rafters distance on U-value 0,55 0,5 U-value [W/m2K] 0,45 80 cm 70 cm 0,4 60 cm 0,35 0,3 10 12 14 15 16 insulation thickness [cm] 07/11/2012 16 8
  • 9. Haw the distance between rafters influence on the U-value two layers insulation influence rafters distance on U-value after renovation 0,320 0,270 U-value [W/m2K] 80 cm 0,220 70 cm 60 cm 0,170 0,120 17 18 19 20 21 22 23 24 25 26 27 28 29 30 insulation thickness [cm ]07/11/2012 17 Popular Roof old one before renovation 1. Roof covering 2. Batten 3. Counter batten 4. Louver (ventilalated gap) 5. Breather membrane 6. Louver (ventilalated gap) or no louver 7. Insulation : mineral wool only between rafters 8. Plasterboard 9. Vapour barrie 10. Stud frames or timber battens 11. Rafters tdp=15oC cold !!!07/11/2012 18 9
  • 10. Popular Roof - mineral wool only between rafters cold internal roof surface in the inhabited attic: feeling of chill radiating from the internal surface of the roof lower comfort of use necessity to wear warmer clothes with time, dirty stripes appear at the rafters lower aesthetic comfort need for more frequent renovation of the internal surface of the roof07/11/2012 19 KI ROOFS SYSTEMS 1. Roof covering 2. Batten 3. Counter batten 4. Louver (ventilalated gap) 5. Breather membrane 6. Louver (ventilalated gap) or no louver 7. Insulation always two layers : Premium Roof Premium Plus Roof 8. Plasterboard 9. Vapour barrie 10. Stud frames or timber battens 11. Rafters tdp=19oC warm !!!07/11/2012 20 10
  • 11. DOUBLE-LAYER KI ROOF SYSTEMS warm internal roof surface in the inhabited attic: comfortable temperature sensed by the inhabitants high comfort of use increased life of the all the internal roof surface materials: eliminated frost penetration into the internal surface of the roof longer life of the internal plasterboard finish no dark or dirty stripes at the rafters no money and time wasted on frequent renovation of the internal roof surface finish07/11/2012 21 PREMIUM PLUS ROOF Blue colour of well insulated Roof in the one of PITCHED ROOF INSULATION SYSTEMS KI means lack of no control and overmuch loss of heat from loft (attic)07/11/2012 22 11
  • 12. KI ROOF Fire Safety The ECOSE Technology mineral wool features the highest fire reaction class A1 which means that the pitched roof products are NON-COMBUSTIBLE The requirements regarding fire reaction class contained in the Construction Law The EI 30 fire resistance class is already provided by installation of the GKF plasterboard (e.g. Knauf) of 12.5 mm thickness, on the inside surface of the roof The EI 60 fire resistance class is already provided by installation of the GKF plasterboard (e.g. Knauf) of 25 mm thickness, or fire-resistant board 18+15 mm (e.g. Knauf), on the inside of the roof07/11/2012 23 PICHED ROOF SYSTEMS KI Insulations systems Insulation between the Insulation under the Knauf Insulation rafters rafters product thickness product thickness [mm] [mm] BETTER PREMIUM ROOF Classic 200 Classic / min.50 TP 115 ENERGY-SAVING Classic 200 Classic / min.100 PREMIUM ROOF TP 115 THE BEST PREMIUM PLUS ROOF Unifit 200 Unifit min. 50 ENERGY-SAVING Unifit 200 Unifit min. 100 PREMIUM PLUS ROOF07/11/2012 24 12
  • 13. PREMIUM PITCHED ROOFENERGY-SAVING PREMIUM PITCHED ROOFRyga08.11.2012r DACH PREMIUM Insulations systems Insulation between the Insulation under the Knauf Insulation rafters rafters product thickness product thickness [mm] [mm] BETTER PREMIUM ROOF Classic 200 Classic / min.50 TP 115 ENERGY-SAVING Classic 200 Classic / min.100 PREMIUM ROOF TP 115 07/11/2012 26 13
  • 14. Premium Roof - Classic + Classic or TP 115 20 cm + min. 10 cm A E nergy-saving - you are in conformity with the Construction Law, and save energy (U < 0.25 W/m2K) Economy - it is beneficial, you can lower your heating bills, A and the roof insulation investment returns in 2 years A $ Flexibility - selection of proper insulation thickness for the specific roof solution A E cology - you reduce your CO2 emission, and you can save 3 trees every year E cose - you can take advantage of all benefits of the new technology A - easy installation, soft touch - less dusty, easy to handle - free from formaldehyde, phenol and acrylic07/11/2012 28 14
  • 15. Premium Roof - Classic + Classic U-value for Premium Roof 0,250 0,200U-value [W/m2K] 0,150 0,100 0,050 0,000 22 23 24 25 26 27 28 29 30 31 32 33 34 35 total insulation thickness [cm] classic 035 classic 035 classic 039 classic 039 classic 042 classic 042 ELASTICALLY (flexible) SYSTEM !!! 07/11/2012 29 Dach premium Classic + TP 115 U-value for Premium Roof 0,250 0,200U-value [W/m2K] 0,150 0,100 0,050 0,000 22 23 24 25 26 27 28 29 30 31 32 33 34 35 total insulation thickness [cm] classic 035 TP 115 classic 039 TP 115 classic 042 TP 115 ELASTICALLY (flexible) SYSTEM !!! 07/11/2012 30 15
  • 16. Classic 035; 039; 042 Thermal Class for Water vapour conductivity thickness diffusion D [ W/mK] tolerances resistance factor Classic 035 0,035 T2 1 Classic 039 0,039 T2 1 Classic 042 0,042 T2 1 T2 ( tolerance of thickness) -5% lub -5mm / +15% lub +15mmApplication : Pitched Roofs07/11/2012 31 TP 115 Technical data : declared thermal conductivity D = 0,037 W/mK declared class for thickness tolerances T2 -5% lub -5mm / +15% or +15mm water vapour diffusion resistance factor = 1 Application : Pitched Roof Partition Walls07/11/2012 32 16
  • 17. STANDARD ROOF installation stages Proper installation of the roof thermal insulation has significant impact on further use of the house. It is not enough to properly insulate the roof, but you also need to perform all the works correctly to provide measurable effects, and to get the investment cost returned sooner thanks to the heating cost savings. Incorrectly made roof insulation may cause creation mould and fungus, and may significantly affect the insulation barrier thermal properties. Install the horizontal battens byMeasure lengths of the fixing them to the rafters, or Install the Classic betweenClassic equal to the install a steel framing consisting the rafters, and thendistance between the of distance hangers and load support it with string.rafters plus 2 cm extra. bearing "C"-struts. 07/11/2012 33 STANDARD ROOF installation stages Install the second layer Install the vapour barrier of the Classic or TP membrane on the entire Fix plasterboards to 115 between the battens internal area of the roof the insulated surface. or steel framing with 10 cm overlap. 07/11/2012 34 17
  • 18. PREMIUM System PREMIUM ROOF ENERGY-SAVING PREMIUM ROOF Good thermal insulation Very good thermal insulation according to the newest trends in energy-saving Solution for professionals Solution for professionals Wide range of products available for specific desired roof insulation properties Wide range of products available for specific desired roof insulation properties Allows to choose the appropriate thermal insulation thickness for the desired roof Allows to choose the appropriate thermal insulation properties insulation thickness for the desired roof insulation properties Fast return on investment after one year Fast return on investment after one year Lower CO2 emission saves Lower CO2 emission saves 3 trees every year 3 trees every year ECOSE Technology advantages ECOSE Technology advantages 07/11/2012 35PREMIUM PLUS PITCHED ROOFENERGY-SAVING PREMIUM PLUS PITCHED ROOFRyga18.11.2010r 18
  • 19. PREMIUM PLUS ROOF Insulations systems Insulation between the Insulation under the Knauf Insulation rafters rafters product thickness product thickness [mm] [mm] THE BEST PREMIUM PLUS ROOF Unifit 200 Unifit min. 50 ENERGY-SAVING Unifit 200 Unifit min. 100 PREMIUM PLUS ROOF07/11/2012 37 19
  • 20. Premium Plus Roof - Unifit + Unifit 15 cm + min. 5 cm Energy-saving - you are in conformity with the Construction Law, A and save energy (U < 0.25 W/m2K) Economy - it is beneficial, you can lower your heating bills, A $ and the roof insulation investment returns in 2 years Economy - its beneficial, you can reduce labour costs for A insulation installation works $ Economy - ts beneficial, you can shorten the installation A works $ Flexibility - selection of proper insulation thickness for the specific A roof solution Ecology - you reduce your CO2 emission, and you can save A some trees every year Ecose - you can take advantage of all benefits A of the new technology07/11/2012 39 Energy-Saving Premium Plus Roof - Unifit + Unifit 20 cm + min. 10 cmA+ E nergy-saving - you are in conformity with the latest European trends in energy saving (U < 0.19 W/m2K) Economy - it is beneficial, you can lower your heating bills, and the roof insulation investment returns in 2 years $A+ Economy - its beneficial, you can reduce labour costs forA+ $ insulation installation works Economy - its beneficial, you can shorten the installation worksA+ $ Flexibility - selection of proper insulation thickness for the specific roof solutionA+ Ecology - you reduce your CO2 emission, and you can save some trees every year E cose - you can take advantage of all benefits A of the new technology07/11/2012 40 20
  • 21. Unifit 035; 039; Thermal Class for Water vapour conductivity thickness diffusion D [ W/mK] tolerances resistance factor Unifit 035 0,035 T2 1 Unifit 039 0,039 T2 1 T2 means -5% lub -5mm / +15% lub +15mm Application : Pitched Roof 07/11/2012 41 STANDARD ROOF installation stages Proper installation of the roof thermal insulation has significant impact on further use of the house. It is not enough to properly insulate the roof, but you also need to perform all the works correctly to provide measurable effects, and to get the investment cost returned sooner thanks to the heating cost savings. Incorrectly made roof insulation may cause creation mould and fungus, and may significantly affect the insulation barrier thermal properties. Install the horizontal battens byMeasure lengths of the fixing them to the rafters, or Install the Unifit betweenUnifit equal to the distance install a steel framing consisting the rafters, withoutbetween the rafters plus 2 of distance hangers and load support it with string.cm extra. bearing "C"-struts. 07/11/2012 42 21
  • 22. WHY Knauf Insulation GMW in the ENERGY-SAVING PITCHED ROOFRyga08.11.2012rEurofins Gold natural resources emission from the building Indoor environment quality Primary greenhouse energy gas emissions (GWP) Water Thermal Indoor Waste comfort air quality 22
  • 23. Eurofins Goldnatural resources emission from the building Indoor environment quality Primary greenhouse energy gas emissions (GWP) Water Thermal Indoor Waste comfort air qualityEurofins Gold without formaldehyde without phenol without acrylic without carcinogenic substances 07/11/2012 46 23
  • 24. What is ECOSE Technology A step change in sustainability for binder technology Revolutionary, new, formaldehyde-free binder technology Based on rapidly renewable materials instead of petro-based chemicals Reduces workplace exposures and pollutant manufacturing emissions Reduces impact on environment through lower embodied energy Offers same benefits to other products where resin-substitution is an advantage Wood based panels Abrasives Friction materialsSuperior handling A new generation of mineral wool that feels goodnaturally Softer feel Odourless Easy to cut 24
  • 25. Superior handling Installer trials Installer trials throughout Europe from 2009 till 2010 with over 5000 installers Softer feel Odourless Easy to cut More than 90% of More than 80% of installers A majority of installers professional installers prefer the neutral smell of indicate an ease in cutting stated a softer feel and mineral wool with ECOSE mineral wool with ECOSE less itchiness compared Technology over the smell Technology. to conventional mineral of traditional glass wool. wool. I prefer this product You really cannot smell it. because, quite simply, This is great stuff! It Its definitely an its easy to work with. doesnt make my skin improvement over the itch; I cant believe that smell of traditional glass this is glass mineral wool and makes the wool. product more pleasant to work withSuperior level of sustainability Mineral wool with ECOSE Technology delivers a superior level of sustainability Manufactured from naturally occurring and/or recycled materials Free from formaldehyde, phenols and acrylics Contributes to improved indoor air quality compared to our conventional mineral wool Improves the overall sustainability of buildings Lower embodied energy Improves the overall sustainability of buildings Cost competitive 25
  • 26. Delivers all the benefits you are used to Proven product performance combined with improved durability Energy saving High insulation efficiency for maximum thermal comfort Non-combustibility for enhanced safety Superb acoustic performance Moisture related properties Improved durabilityProven performance 26
  • 27. Proven performanceImproved durability 27
  • 28. Thank you for attention 28