VALVES and TECHNOLOGIES for WATER WORLD
www.acmospa.com
AC.MO S.p.A si riserva il diritto di apportare modifiche anche senza preavviso, al fine di un miglior standard qualitativo. E’ proibito l’uso non autorizzato delle specifiche tecniche.AC.MO S.p.A. reserves the right to modify the specifications and data contained in this catalogue, even without prior notice, in order to improve its quality standards. Non authorized use is forbidden.
AC.MO S.p.A. se réserve le droit de modifier le projet sans préavis, pour en améliorer le standard de qualité. L’utilisation de la présente fiche technique, sans préalable autorisation écrite AC.MO, est interdite.
ED.1 01/2012
0$.***
0WFSWJFX
5IF0$.***JTBIJHIBDDVSBDZVMUSBTPOJDnPXNPOJUPSGPSPQFODIBOOFMT
#FOFmUT
t *OnVFOUBOEF÷VFOUNPOJUPS
t #4DBMDVMBUJPOTQSPWJEFFYDFQUJPOBMBDDVSBDZJONFBTVSJOHnPX
t UPNPOUITEBUBMPHTVCKFDUUPMPHHJOHSBUF
t 34TFSJBMDPNNVOJDBUJPO
t )JHIBDDVSBDZPOVOJRVFPSOPOTUBOEBSEXFJSTBOEnVNFT
t "$BOE%$PQFSBUJPO"VUPNBUJDBMMZTXJUDIFTUPCBUUFSZPQFSBUJPOGPSVOJOUFSSVQUFEQPXFS
t %VBMQPXFSJOQVU
t -PXQPXFSSFNPUFNPOJUPSJOHt 'MPX3FQPSUFSTPGUXBSFBWBJMBCMFGPSSFNPUFNPOJUPSJOH
DPOmHVSBUJPOBOEEBUBSFUSJFWBM
"QQMJDBUJPO
*OBEEJUJPOUPNPOJUPSJOHnPXSBUFJOTFXBHFXPSLT0$.***DBONPOJUPSJOEVTUSJBMEJTDIBSHFSBJOGBMMTUPSNXBUFSTUVEJFTJOnPXJOmMUSBUJPOTUVEJFTBOETFXFSTZTUFNFWBMVBUJPOT"TXFMMBTCFJOHDPNQBUJCMFXJUINBOZTUBOEBSEXFJSTBOEnVNFTUIFQSPHSBNNBCMFIFBEWFSTVTnPXDVSWFVQUPQPJOUTBDDVSBUFMZEFmOFTnPXSBUFPOVOJRVFPSOPOTUBOEBSEXFJSTBOEnVNFT
5IF0$.***IBTEBUBMPHHJOHBOEJTBEKVTUBCMFGSPNPODFQFSNJOVUFUPPODFBEBZ*USFDPSETUIFBWFSBHFnPXSBUFGPSUIBUUJNFQFSJPE%BJMZJUSFDPSETNJOJNVNNBYJNVNPGUFNQFSBUVSFBOEnPXSBUFTBOEUIFUJNFUIFZPDDVSSFEBTXFMMBTUIFEBJMZUPUBM"EWBODFEGVODUJPOTJODMVEFWBSJBCMFSBUFMPHHJOH*UDBOCFQSFQSPHSBNNFEUPMPHBUBIJHIFSSBUFXIFOOFFEFE6OEFSTUFBEZDPOEJUJPOTUIF0$.***BVUPNBUJDBMMZMPHTMFTTGSFRVFOUMZUPDPOTFSWFEBUBMPHTQBDF
5IF0$.***IBTUXPXBZDPNNVOJDBUJPOWJB34XJUIBNPEFNPSBCJQPMBSDVSSFOUMPPQXJUIBDVSSFOUUPWPMUBHFDPNNVOJDBUJPODPOWFSUFS%BUBMPHTDBOCFEPXOMPBEFEUPBmMFUIBUDBOCFNBOJQVMBUFEJOUPBTQSFBETIFFUPS"4$**GPSNBU
SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE MESUREKAT-06......
ACMO | datasheets
FIG. 5121
MISURATORE DI PORTATA AD ULTRASUONI PER CANALI APERTIULTRASONIC FLOW MONITOR FOR OPEN CHANNELSDEBITMETRE ULTRASONIQUE POUR CANAUX OUVERTS
k06f-F5121-STD-00
7/28/2019 k06f-Misuratori Di Portata Ad Ultrasuoni Per Canali Aperti
http://slidepdf.com/reader/full/k06f-misuratori-di-portata-ad-ultrasuoni-per-canali-aperti 2/4
VALVES and TECHNOLOGIES for WATER WORLD
www.acmospa.com
AC.MO S.p.A si riserva il diritto di apportare modifiche anche senza preavviso, al fine di un miglior standard qualitativo. E’ proibito l’uso non autorizzato delle specifiche tecniche.AC.MO S.p.A. reserves the right to modify the specifications and data contained in this catalogue, even without prior notice, in order to improve its quality standards. Non authorized use is forbidden.
AC.MO S.p.A. se réserve le droit de modifier le projet sans préavis, pour en améliorer le standard de qualité. L’utilisation de la présente fiche technique, sans préalable autorisation écrite AC.MO, est interdite.
ED.1 01/2012
0$.***
5FDIOJDBMTQFDJmDBUJPOT
1SPHSBNSBOHFJTEFmOFEBTUIFFNQUZEJTUBODFUPUIFGBDFPGUIFUSBOTEVDFSQMVTBOZSBOHFFYUFOTJPO
&.$QFSGPSNBODFBWBJMBCMFVQPOSFRVFTU8JOEPXTJTBSFHJTUFSFEUSBEFNBSLPG.JDSPTPGU$PSQPSBUJPO
.PEFPG0QFSBUJPO
.FBTVSJOHSBOHF yNyGUPSy NyGU
0VUQVU
5SBOTEVDFS &DIPNBY934L)[
3FMBZT BMBSNDPOUSPMSFMBZT41%5'PSN$DPOUBDUQFSSFMBZSBUFE "BU7"$OPOJOEVDUJWFPS 7%$
N"PVUQVU yN"JTPMBUFEt .BYMPBE , NBYMPBEt 3FTPMVUJPO V"t *TPMBUJPO 7"$DPOUJOVPVTt %$PVUQVU 7%$N"BWFSBHFUP
N"BUEVUZDZDMF
NBY y"DDVSBDZ
&SSPSJONFBTVSFNFOU NNNDBMDVMBUFEFSSPSMFTTUIBO
3FTPMVUJPO NN
3BUFEPQFSBUJOHDPOEJUJPOT
*OTUBMMBUJPODPOEJUJPOT
t -PDBUJPO *OEPPSPVUEPPS
t *OTUBMMBUJPODBUFHPSZ **
t 1PMMVUJPOEFHSFF
"NCJFOUDPOEJUJPOT
t "NCJFOUUFNQFSBUVSFFODMPTVSF y¡$y¡'
%FTJHO
8FJHIU LHMCT
.BUFSJBMFODMPTVSF 1PMZDBSCPOBUF
%FHSFFPGQSPUFDUJPOFODMPTVSF *15ZQF9/&."9
$BCMF
5SBOTEVDFSBOEN"PVUQVUTJHOBM t 5SBOTEVDFSDPBYJBMUPCF3("6MPXDBQBDJUZ
t N"PVUQVUTJHOBMUPCFDPQQFS DPOEVDUPSTUXJTUFEXJUIGPJMTIJFMEESBJOXJSF 7yNN¤y"8(
t 3FMBZQPXFSUPCFDPQQFSDPOEVDUPSTQFSMPDBMSFRVJSFNFOUTUPNFFU7 " DPOUBDUSBUJOH
.BYTFQBSBUJPOCFUXFFOUSBOTEVDFSBOEUSBOTDFJWFS
NGU
%JTQMBZTBOEDPOUSPMT -$%YEPUNBUSJYEJTQMBZXJUIMJOFTPGDIBSBDUFSTFBDI
1SPHSBNNJOH 7JBSFNPWBCMFQSPHSBNNFSBOEDPNNVOJDBUJPOMJOL
.FNPSZ 7CBUUFSZ/&%"-$PSFRVJWBMFOUPQFSBUJOHMJGFZFBS4VQFS$BQDBQBDJUPSGPSCBDLVQEVSJOHCBUUFSZSFQMBDFNFOU
1PXFSTVQQMZ
"$WFSTJPO 7"$)[7"NBY
%$WFSTJPO y7%$8NBY
$FSUJmDBUFTBOEBQQSPWBMT $&'.$4" 64$ .$&354
$5*$,
$PNNVOJDBUJPO 34PSN"CJQPMBSDVSSFOUMPPQCBVE
0QUJPOT
5FNQFSBUVSFTFOTPS 54
3FNPUFNPOJUPSJOH 'MPX3FQPSUFS B8JOEPXTCBTFEDPOmHVSBUJPOTPGUXBSFBOEEBUBFYUSBDUPS
7FMPDJUZTFOTPS JOQVU *OQVUSBOHF y7%$3FTPMVUJPON7
SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE MESUREKAT-06......
ACMO | datasheets
FIG. 5121
MISURATORE DI PORTATA AD ULTRASUONI PER CANALI APERTIULTRASONIC FLOW MONITOR FOR OPEN CHANNELSDEBITMETRE ULTRASONIQUE POUR CANAUX OUVERTS
k06f-F5121-STD-00
7/28/2019 k06f-Misuratori Di Portata Ad Ultrasuoni Per Canali Aperti
http://slidepdf.com/reader/full/k06f-misuratori-di-portata-ad-ultrasuoni-per-canali-aperti 3/4
VALVES and TECHNOLOGIES for WATER WORLD
www.acmospa.com
AC.MO S.p.A si riserva il diritto di apportare modifiche anche senza preavviso, al fine di un miglior standard qualitativo. E’ proibito l’uso non autorizzato delle specifiche tecniche.AC.MO S.p.A. reserves the right to modify the specifications and data contained in this catalogue, even without prior notice, in order to improve its quality standards. Non authorized use is forbidden.
AC.MO S.p.A. se réserve le droit de modifier le projet sans préavis, pour en améliorer le standard de qualité. L’utilisation de la présente fiche technique, sans préalable autorisation écrite AC.MO, est interdite.
ED.1 01/2012
0$.***
%JNFOTJPOBMESBXJOHT
0$.***EJNFOTJPOTJONNJODI
4DIFNBUJDT
0$.***DPOOFDUJPOT
Suitable location for conduit entrances.
Siemens Milltronics recommends using
a punch for making holes in enclosure.
Lid
Enclosure
Customer mounting
screw
Mounting holes
(accessed under lid)
4.3 mm (0.17") dia. /
4 places
Lid screws (6 places)
Programmer
91 (3.6)
106 (4.2)
172 (6.8)
209 (8.2)16 (0.6)
2 8 5 ( 1 1 . 2 )
2 6 7 ( 1 0 . 5 )
1.
2.
Use RG62-A/U coaxial (or equivalent) for extensions up to 183 m (600 ft).
Run in grounded metal conduit, separate from other wiring.
Each relay has 1 set of form 'C' (SPDT) contacts, relay rated at 5 A, 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.
Relay de-energized when in alarm conditions and energized for pump control.
Notes:
Position SW1for 100/115/
200/230 V AC
operation(50/60 Hz,
20 VA)
S H L D
S H L D
S H L D
Temp. Sensor Trans-ducer
tupnIO/Ir alopiBP/Otner r uCPower
P 24 V Outputmax. load
average 20 mAPulse 200 mA
1/10 duty
RS-232 I/O
S H L D
B L K
W H T
+Vel
Input
+ AuxInput
C O M
C O M
RL1 RL2
–+ –+ –+
–+
231322120291817161514131211101987654321 630392827262524232 33 34 35
S Y N C
P 2 4 V L2/N L1
RL3
R X
R X
T X
T X
T X D
R X D
9-30 V
0-10 V
H o t
SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE MESUREKAT-06......
ACMO | datasheets
FIG. 5121
MISURATORE DI PORTATA AD ULTRASUONI PER CANALI APERTIULTRASONIC FLOW MONITOR FOR OPEN CHANNELSDEBITMETRE ULTRASONIQUE POUR CANAUX OUVERTS
k06f-F5121-DIM-00
7/28/2019 k06f-Misuratori Di Portata Ad Ultrasuoni Per Canali Aperti
http://slidepdf.com/reader/full/k06f-misuratori-di-portata-ad-ultrasuoni-per-canali-aperti 4/4
VALVES and TECHNOLOGIES for WATER WORLD
www.acmospa.com
ED.1 01/2012
KAT-06...... SISTEMI DI MISURA / SYSTEMS MEASURE / SYSTEMES DE MESURE