Aphrodite€¦ · Aphrodite visit twinkl.com. Apollo visit twinkl.com. Ares visit twinkl.com
just-insulation.com · Web view2. 2. 3. 3. 6. 6. 7. 7. Visit to download the full product...
Transcript of just-insulation.com · Web view2. 2. 3. 3. 6. 6. 7. 7. Visit to download the full product...
Insulation CI/Sfb (2–) Rn7 M2
Fourth Issue June 2011
Product SelectorINSULATION FOR ROOFS, WALLS & FLOORS
Low Energy – Low Carbon Buildings
2
Kingspan Insulation Ltd reserves the right to amend product specifications without prior notice. The information contained in the document is given in good faith and applies to the uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. Kingspan Insulation recommend using the Technical Advice service (see back cover).
3
ContentsPage
Product Selector Chart 4
U–value Time Saver 6
Building Regulations and Standards 7
Roof Insulation 9Kooltherm® K7 Pitched Roof Board 10Thermapitch® TP10 11Thermaroof® TR21 12Thermaroof® TR25 13Thermaroof® TR26 LPC/FM 14Thermaroof® TR27 LPC/FM 15Thermaroof® TR31 16Thermataper® TT46 LPC/FM 17Thermataper® TT47 LPC/FM 18Kooltherm® K11 Roofboard 19Styrozone® N 300 R 20Styrozone® H 350 R 21Styrozone® N 500 R 22Styrozone® N 700 R 23
Wall Insulation 25Kooltherm® K5 External Wall Board 26Kooltherm® K8 Cavity Board 27Kooltherm® K12 Framing Board 28Kooltherm® K15 Rainscreen Board 29Kooltherm® K17 Insulated Plasterboard 30Kooltherm® K18 Insulated Plasterboard 31Thermawall® TW50 32Thermawall® TW55 33Styrozone® N 300 R 20Styrozone® H 350 R 21
Floor Insulation 35Kooltherm® K3 Floorboard 36Kooltherm® K10 FM Soffit Board 37Thermafloor® TF70 38Thermafloor® TF73 39Styrozone® N 300 R 20Styrozone® H 350 R 21Styrozone® N 500 R 22Styrozone® N 700 R 23
Cavity Closers 41Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS 42Thermabate® & Thermabate® PLUS 44
Breathable Membranes 46nilvent® 47
Roof Wall
Floor Cavity
Breathable
4
Product Selector
Roof Insulation
Kool
ther
m®
K7
Pitc
hed
Roof
Boa
rd
Ther
map
itch®
TP1
0Th
erm
aroo
f® T
R21
Ther
mar
oof®
TR2
5Th
erm
aroo
f® T
R26
LPC/
FM
Ther
mar
oof®
TR2
7 LP
C/FM
Ther
mar
oof®
TR3
1Th
erm
atap
er®
TT4
6 LP
C/FM
Ther
mat
aper
® T
T47
LPC/
FMKo
olth
erm
® K
11 R
oof B
oard
Styr
ozon
e® N
300
R
Styr
ozon
e® H
350
RSt
yroz
one®
N 5
00 R
Styr
ozon
e® N
700
Rni
lven
t®
Pitched Roof InsulationOver / between / under rafter sarking ✔ ✔
Breathable membrane ✔Flat Roof InsulationTapered Roofing System ✔ ✔Under partially bonded built–up felt ✔ ✔ ✔ ✔
Under cold liquid applied waterproofing ✔ ✔ ✔
Under mastic asphalt ✔ ✔Directly over timber joists ✔Under torch–on felt waterproofing
✔
Under mechanically–fixed, single–ply non–bituminous membranes
✔ ✔ ✔ ✔
Under fully adhered singly–ply membranes
✔ ✔
In LPCB/FM approved constructions
✔ ✔ ✔ ✔
Protected Membrane RoofsTraditionally protected membrane / Roof gardens
✔ ✔
Car park decks ✔ ✔ ✔ ✔Lightweight protected membrane/ maintenance access ✔ ✔
Green RoofsInsulation suitable for use under Green Roofs ✔ ✔ ✔ ✔ ✔ ✔
Product Selector
Floor
5
H eavy duty / industrial / cold store floors
Soffit liningFloating ground floorsSuspended ground floorsSolid ground floors
✔ ✔ Kooltherm® K3 Floorboard✔ Kooltherm® K10 FM Soffit Board
✔ ✔ ✔ Thermafloor® TF70
✔ Thermafloor® TF73
✔ Styrozone® N 300 R
✔ Styrozone® H 350 R
✔ Styrozone® N 500 R
✔ Styrozone® N 700 R
B reathable mem
brane
Cavity ClosersBasem
ent wallsSteel fram
eTim
ber frame
Rainscreen cladding systems
Insulated render systems
Internal dry–liningPartial fill cavity walls
✔ Kooltherm® K5 External wall Board✔ Kooltherm® K8 Cavity Board
✔ ✔ Kooltherm® K12 Framing Board✔ Kooltherm® K15 Rainscreen Board
✔ Kooltherm® K17 Insulated Plasterboard
✔ Kooltherm® K18 Insulated Plasterboard
✔ Thermawall® TW50✔ ✔ Thermawall® TW55
✔ Styrozone® N 300 R✔ Styrozone® H 350 R
✔ nilvent®
✔ Kooltherm® Cavity Closer & Kooltherm® Cavity Closer PLUS
✔ Thermabate® & Thermabate® PLUS
6
U–value Time SaverHelp us to help you when requesting U–values from Kingspan Insulation’s Technical Advice Service. Please provide the following information for all building elements:• What U–value is required?• Project address and postcode• Type of building eg. Offices.
Flat Roof• What is the type of waterproofing being used?• What is the roof substrate – timber, concrete or profiled metal deck?• Is there a ceiling – if yes then is it plasterboard or suspended tile?• If using Kingspan Thermaroof® TR31 what are the joist size centres?• If mechanical fixings are being used – what are they (carbon steel,
galvanised steel, stainless steel or telescopic fixings)?
Pitched Roof• What are the size and centres of the rafters or ceiling joists?• Is the insulation at ceiling or rafter level?• If at rafter level, is there a 50 mm ventilated airspace between the rafters above the
insulation?• If no 50 mm ventilated airspace, is there a breathable membrane above the rafters?• If a breathable membrane is being used is it above or below the counter batten or draped into
the rafter void?
Wall Construction• What is the wall construction – cavity, solid wall, rendered?• If cavity wall construction, what is the manufacturer and type of block being
used for inner (and outer if applicable) leaf or its thermal conductivity (may also be known as λ–value?)
• What is the internal wall finish?• Is the wall above ground or basement wall?
Ground Floor• What is the perimeter / area ratio? (This is the length of the externally exposed floor slab
perimeter measured on the inside wall, not including internal or separating walls, divided by the floor area.)
• Is the floor a solid ground bearing slab, suspended beam & block or suspended timber or concrete floor (if suspended timber the joist size and centres are required.)
Floor Other Than Ground• Is soffit insulation required?• If the insulation is to be fitted between joists what are the joist size and centres?
Technical Advice
Telephone: 01544 387 382 Fax: 01544 387 482 Email:
7
Building Regulations and Standards
England and WalesNew Buildings (ADL 1A & ADL 2A)The main requirement of Approved Documents L1A and L2A is that buildings meet a defined CO2 emissions target. The roof, wall and floor U–values required to meet this target will depend on the design of the building, orientation, heating system etc. To ease the process, Kingspan Insulation has undertaken analysis to give the ‘best starting point’ U–values, for specifiers to work from in getting their designs to comply. They will be almost exactly what is required for some buildings and short of what is required for others.These ‘best starting point’ U–values are shown below.Existing Buildings (ADL 1B & ADL 2B)Approved Documents L1B and L2B give specific U–value requirements for newly constructed elements and retained / refurbished elements. They apply to all works, regardless of whether the works relate to an extension, conversion or renovation.These required U–values are shown below.
New Buildings Existing BuildingsBest Starting Point Extension, Conversion and
Renovation Of All BuildingsDwellings Buildings Other
Than DwellingsNew Elements Refurbishment /
Retained ElementsLofts 0.13 0.14 0.16 0.16
All other roofs 0.13 0.14 0.18 0.18Walls 0.18 0.22 0.28 0.30Floors 0.13 0.18 0.22 0.25
ScotlandNew Buildings (Section 6 – Energy)The main requirement of Technical Handbooks Sections 6 is that buildings meet a defined CO2 emissions target. For domestic, this target is generated by a set of 2010 notional buildings, which also offer a simplified elemental approach to compliance. If a building is constructed in accordance with the parameter values that define the notional building, then it will automatically comply with the CO2 emissions target. The ‘notional’ U–values for roofs, walls and floors are shown opposite. For non–domestic, the approach is the same as that described overleaf for ADL2A and ‘best starting point’ U–values are shown below.Existing Buildings (Section 6 – Energy)Technical Handbooks Sections 6 give specific area–weighted average U–value requirements for newly constructed elements and altered/ refurbished elements. They apply to most works*, regardless of whether the works relate to an extension, renovation, or conversione.g. of a whole unheated building, loft or garage. For existing dwellings, there are differing requirements for newly constructed elements, depending upon the thermal efficiency of the existing building*. The required U–values are shown below.
New Buildings Existing BuildingsDomestic Non–
DomesticExtension, Conversion &
Renovation – Most Works*Notional Building
Best Starting Point
Domestic New
Elements A*
Domestic New
Elements B*
Domestic Altered /
Refurbished Elements
Non– Domestic
Lofts 0.13 0.13 0.13 0.15 0.15 0.15All other roofs 0.13 0.13 0.15 0.18 0.18 0.15Walls 0.19 0.22 0.19 0.22 0.22 0.25Floors 0.15 0.18 0.15 0.18 0.18 0.20
* There are specific exceptions relating to, e.g. conversion of heated buildings and infilling of openings. Please consult the Technical Handbooks. Column B applies where the existing building has, or will be improved to have, wall U–values better than 0.7 W/m2.K and roof U–values better than 0.25 W/m2.K. If the U–values are worse, then column A applies.
.
_.,
I
. . /. . . ...,....,/ . .
.. ..I';/' . . . .
. . . .,,
..,rl>.,tP< . . . . .
,· . . . .
•
Roof Insulation
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
1
K7 Pitched Roof BoardINSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACESRecommended for:✔ New build✔ Re–roofing✔ Loft conversion✔ Unventilated pitched roofs – between rafters✔ Unventilated pitched roofs –
between and over rafters✔ Ventilated pitched roofs –
between rafters
Kingspan nilvent ®
Kingspan Kooltherm® K7 Pitched Roof Board
Kingspan Kooltherm® K18 Insulated Plasterboard
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Composite foilCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 2.4 m
Thicknesses Available 25 – 140 mmComplementary Products • nilvent® (page 47)
• Kooltherm® K18 Insulated Plasterboard (page 31)
Roof
1
TP10INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACESRecommended for:✔ New build✔ Re–roofing✔ Loft conversion✔ Unventilated pitched roofs – between rafters✔ Unventilated pitched roofs –
between and over rafters✔ Ventilated pitched roofs –
between rafters
Kingspan nilvent ®
Kingspan Thermapitch® TP10
Kingspan Kooltherm® K18 Insulated Plasterboard
Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products • nilvent® (page 47)
• Kooltherm® K18 Insulated Plasterboard (page 31)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
1
TR21INSULATION FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT–UP FELT AND MASTIC ASPHALTRecommended for:✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
Kingspan Thermaroof® TR21
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.027 W/m.K (insulant thickness < 80 mm)
0.026 W/m.K (insulant thickness 80 – 119 mm)0.025 W/m.K (insulant thickness ≥ 120 mm)
Facings Glass reinforced perforated celluloseCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 0.6 mThicknesses Available 30 – 120 mmComplementary Products
Roof
1
TR25INSULATION FOR FLAT ROOFS WATERPROOFED WITH COLD LIQUID APPLIED WATERPROOFINGRecommended for:✔ Fast–track building programmes✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
Kingspan Thermaroof® TR25
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)
0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120mm)
Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 0.6 mThicknesses Available 50 – 120 mmComplementary Products
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
1
TR26 LPC/FMINSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE–PLY WATERPROOFINGRecommended for:✔ LPCB / FM compliance✔ Fast–track building programmes✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
LPS 1181: Part 1Certificate No.
388b/01Class 1 Roof Construction
Kingspan Thermaroof® TR26
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 2.4 mThicknesses Available 25 – 150 mmComplementary Products • Thermataper® TT46 LPC/FM (page 17)
Roof
mes
ecks
1
TR27 LPC/FMINSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE–PLY, PARTIALLY BONDED BUILT–UP FELT, MASTIC ASPHALT AND COLD LIQUID APPLIED WATERPROOFINGRecommended for:✔ LPCB / FM compliance✔ Fast–track building program✔ New build✔ Refurbishment✔ Metal, concrete or timber d
LPS 1181: Part 1Certificate No.
388b/01Class 1 Roof Construction
Kingspan Thermaroof® TR27
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)
0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120mm)
Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 0.6 m and 1.2 x 2.4 mThicknesses Available 25 – 130 mm (1.2 x 0.6 m boards) and 50 – 145 mm (1.2 x 2.4 m
boards)Complementary Products • Thermataper® TT47 LPC/FM (page 18)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
1
TR31STRUCTURAL INSULATION / FSC CERTIFIED PLYWOOD COMPOSITE FOR FLAT ROOFS WATERPROOFED WITH PARTIALLY BONDED BUILT–UP FELTRecommended for:✔ New build✔ Refurbishment✔ Directly over timber decks
Kingspan Thermaroof® TR31
Kingspan Kooltherm® K8 Cavity Board
Kingspan Kooltherm® K7 Pitched Roof Board
Product DataThermal Conductivity 0.022 W/m.K (insulant)
0.140 W/m.K (plywood)Upper Facing FSC certified 6 mm WBP exterior grade plywoodCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Lower Facing Composite foilBoard Size 1.2 x 2.4 mThicknesses Available 50 – 120 mm (Insulation thickness only)Complementary Products
Roof
1
TT46 LPC/FMTAPERED INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE–PLY WATERPROOFINGRecommended for:✔ Alternative to expensive screed–to falls roofs✔ Reducing load–bearing
implications for new or existing structures
✔ Fast–track building programmes✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
LPS 1181: Part 1Certificate No.
388b/01Class 1 Roof Construction
Kingspan Thermataper® TT46 LPC/FM
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 2.4 mManufactured Rate of Fall
1:30; 1:40; 1:60; 1:80Complementary Products • Thermaroof® TR26 LPC/FM (page 14)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
1
order samples and learn about case studies
1
TT47 LPC/FMTAPERED INSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY ADHERED SINGLE–PLY, PARTIALLY BONDED BUILT–UP FELT, MASTIC ASPHALT AND COLD LIQUID APPLIED WATERPROOFINGRecommended for:✔ Alternative to expensive screed–to falls roofs✔ Reducing load–bearing
implications for new or existing structures
✔ Fast–track building programmes✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
LPS 1181: Part 1Certificate No.
388b/01Class 1 Roof Construction
Kingspan Thermataper® TT47 LPC/FM
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.026 W/m.K (insulant thickness < 80 mm)
0.025 W/m.K (insulant thickness 80 – 119 mm)0.024 W/m.K (insulant thickness ≥ 120 mm)
Facings Coated glass tissueCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 0.6 m and 1.2 x 2.4 mManufactured Rate of Fall
1:30; 1:40; 1:60; 1:80Complementary Products • Thermaroof® TR27 LPC/FM (page 15)
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
2
K11 RoofboardINSULATION FOR FLAT ROOFS WATERPROOFED WITH FULLY BONDED TORCH APPLIED MULTI–LAYER BITUMINOUS WATERPROOFINGRecommended for:✔ New build✔ Refurbishment✔ Metal, concrete or timber decks
Kingspan Kooltherm® K11 Roof Board
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness 25 – 44 mm)
0.021 W/m.K (insulant thickness ≥ 45 mm)0.050 W/m.K (perlite)
Upper Facing 20 mm bitumen coated perliteCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Lower Facing Glass tissue
Board Size 1.2 x 1.0 mThicknesses Available 40 and 70 mm (Insulation thickness only)Complementary Products
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
2
N 300 RINSULATION FOR INVERTED ROOFS, BASEMENTS, CAR PARK DECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL AND COLD STORE FLOORINGRecommended for:✔ New build✔ Refurbishment✔ Inverted / protected
membrane roofs✔ Basement walls✔ Below floor slab or screed
Kingspan Kooltherm® K8 Cavity Board
Kingspan Styrozone® N 300 R
Product DataThermal Conductivity 0.035 W/m.K (insulant thickness < 80 mm)
1.37 W/m.K (insulant thickness 80 mm)1.38 W/m.K (insulant thickness 100 − 160 mm)0.040 W/m.K (insulant thickness > 160 mm)
Core High performance rigid extruded polystyrene insulant manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.25 x 0.6 m
Thicknesses Available 30 – 180 mmComplementary Products • Styrozone® H 350 R (page 21)
Roof
2
H 350 RINSULATION FOR INVERTED ROOFS, BASEMENTS, CAR PARK DECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL AND COLD STORE FLOORINGRecommended for:✔ New build✔ Refurbishment✔ Inverted / protected membrane roofs✔ Basement walls✔ Below floor slab or screed
Kingspan Styrozone® H 350 R
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.029 W/m.K (insulant thickness ≤ 120 mm)
0.031 W/m.K (insulant thickness > 120 mm)Core High performance rigid extruded polystyrene insulant manufactured with a
blowing agent that has zero Ozone Depletion Potential (ODP)Board Size 1.25 x 0.6 mThicknesses Available 30 – 160 mmComplementary Products • Styrozone® N 300 R (page 20)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
2
N 500 RINSULATION FOR CAR PARK DECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL AND COLD STORE FLOORINGRecommended for:✔ New build✔ Refurbishment✔ Inverted / protected membrane roofs✔ Below floor slab or screed
Kingspan Styrozone® N 500 R
Product DataThermal Conductivity 0.036 W/m.K (insulant thickness ≤ 70 mm)
0.038 W/m.K (insulant thickness > 70 mm)Core High performance rigid extruded polystyrene insulant manufactured with a
blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.25 x 0.6 m
Thicknesses Available 30 – 120 mmComplementary Products • Styrozone® N 300 R (page 20)
• Styrozone® H 350 R (page 21)• Styrozone® N 700 R (page 23)
Roof
2
N 700 RINSULATION FOR CAR PARK DECKS, AND HEAVY DUTY COMMERCIAL, INDUSTRIAL AND COLD STORE FLOORINGRecommended for:✔ New build✔ Refurbishment✔ Inverted / protected membrane roofs✔ Below floor slab or screed
Kingspan Styrozone® N 700 R
Product DataThermal Conductivity 0.036 W/m.K (insulation thickness ≤ 50 mm)Core High performance rigid extruded polystyrene insulant manufactured with a
blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.25 x 0.6 m
Thicknesses Available 50 mmComplementary Products • Styrozone® N 500 R (page 22)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Roof
Kingspan Kooltherm® K8 Cavity Board24
Wall Insulation
Wall
2
K5 External Wall BoardEXTERNAL INSULATION FOR MASONRY WALLSRecommended for:✔ Solid walled buildings✔ Transforming and
upgrading the appearance of
existing buildings
✔ New build✔ Refurbishment✔ Insulated render
system on masonry
Kingspan Kooltherm® K5 External Wall Board
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Glass tissueCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 0.6 m
Thicknesses Available 20 – 100 mmComplementary Products
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Wall
Visit www.kingspaninsulation.co.uk to download the full product brochure,
2
K8 Cavity BoardPARTIAL FILL CAVITY WALL INSULATIONRecommended for:✔ Traditional cavity wall construction methods✔ New build✔ All brick and block types
Kingspan Kooltherm® K8 Cavity Board
Kingspan Kooltherm® K3 Floorboard
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Composite foilCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 0.45 m
Thicknesses Available 20 – 120 mmComplementary Products • Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page
42)• Thermabate® and Thermabate® PLUS Cavity Closer (page 44)
Wall
2
K12 Framing BoardINSULATION FOR TIMBER AND STEEL FRAMING SYSTEMSRecommended for:✔ Insulating between studs✔ Insulating sheathing✔ Steel frame walls✔ Timber clad / tile
hung timber frame walls
Kingspan Kooltherm® K12 Framing Board
Kingspan nilvent®
Kingspan Kooltherm® K18 Insulated Plasterboard
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Composite foilCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 2.4 m
Thicknesses Available 25 – 140 mmComplementary Products • nilvent® (page 47)
• Kooltherm® K18 Insulated Plasterboard (page 31)
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Wall
Visit www.kingspaninsulation.co.uk to download the full product brochure,
2
K15 Rainscreen BoardINSULATION FOR RAINSCREEN CLADDING SYSTEMSRecommended for:✔ Proprietary and non–
proprietary external finishes
✔ Insulated rainscreen cladding systems on both masonry and steel frames
✔ New build✔ Refurbishment
Kingspan Kooltherm® K15 Rainscreen Board
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Composite foilCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 2.4 m
Thicknesses Available 25 – 130 mmComplementary Products
Kingspan Kooltherm® K15 Rainscreen Board is also available with a black foil face.
Wall
3
K17 Insulated PlasterboardINSULATED PLASTERBOARD FOR PLASTER DAB / ADHESIVE BONDED DRY–LININGRecommended for:✔ Traditional cavity walls✔ Solid rendered walls✔ Insulation and dry–lining
applications✔ New build✔ Refurbishment
Kingspan Kooltherm® K17 Insulated Plasterboard
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)0.190 W/m.K (plasterboard)
Front Facing 12.5 mm plasterboardCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Reverse Facing Glass tissue
Board Size 1.2 x 2.4 mThicknesses Available 20 – 100 mm (Insulation thickness only)Complementary Products • Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page
42)• Thermabate® and Thermabate® PLUS Cavity Closer (page 44)• Kooltherm® K18 Insulated Plasterboard (page 31)
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Wall
Visit www.kingspaninsulation.co.uk to download the full product brochure,
3
K18 Insulated PlasterboardINSULATED PLASTERBOARD FOR MECHANICALLY FIXED DRY–LININGRecommended for:✔ Solid walls✔ Timber frame walls✔ Timber rafters✔ Metal furring systems✔ Insulation, dry–lining and
vapour control applications
✔ New build✔ Refurbishment✔ Loft conversions
Kingspan Kooltherm® K18 Insulated Plasterboard
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)0.190 W/m.K (plasterboard)
Front Facing 12.5 mm plasterboardCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Reverse Facing Composite foil
Board Size 1.2 x 2.4 mThicknesses Available 20 – 100 mm (Insulation thickness only)Complementary Products • Kooltherm® K12 Framing Board (page 28)
• Kooltherm® K7 Pitched Roofing Board (page 10)• Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page
42)• Thermabate® and Thermabate® PLUS Cavity Closer (page 44)• Kooltherm® K17 Insulated Plasterboard (page 30)
Wall
3
TW50PARTIAL FILL CAVITY WALL INSULATIONRecommended for:✔ Traditional cavity wall construction methods✔ New build✔ All brick and block types
Kingspan Thermawall® TW50
Product DataThermal Conductivity 0.022 W/m.KFacings Composite FoilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 0.45 mThicknesses Available 20 – 100 mmComplementary Products • Thermabate® and Thermabate® PLUS Cavity Closer (page 44)
• Kooltherm® Cavity Closer and Kooltherm® Cavity Closer PLUS (page 42)
• Kooltherm® K8 Cavity Board (page 27)
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Wall
Visit www.kingspaninsulation.co.uk to download the full product brochure,
3
TW55INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMSRecommended for:✔ Insulating between studs✔ Insulating sheathing✔ Steel frame walls✔ Timber clad / tile
hung timber frame walls
Kingspan Thermawall® TW55
Kingspan nilvent ®
Kingspan Kooltherm® K18 Insulated Plasterboard
Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products • Kooltherm® K18 Insulated Plasterboard (page 31)
• nilvent® (page 47)• Kooltherm® K12 Framing Board (page 28)
Wall
Kingspan Kooltherm® K3 Floorboard34
Floor Insulation
Floor
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
3
K3 FloorboardINSULATION FOR FLOORSRecommended for:✔ Below the floor slab / screed✔ Beam and block floors✔ Suspended timber floors✔ Underfloor heating applications✔ Floor perimeter insulation✔ New build✔ Refurbishment
Kingspan Kooltherm® K8 Cavity Board
Kingspan Kooltherm® K3 Floorboard
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Facings Glass tissueCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Board Size 1.2 x 2.4 m
Thicknesses Available 25 – 140 mmComplementary Products
Floor
Visit www.kingspaninsulation.co.uk to download the full product brochure,
3
K10 FM Soffit BoardINSULATION FOR STRUCTURAL CEILINGS (SOFFITS)Recommended for:✔ Insulating under structural ceilings✔ Car park ceilings
Kingspan Kooltherm® K10 Soffit Board
Product DataThermal Conductivity 0.023 W/m.K (insulant thickness < 25 mm)
0.021 W/m.K (insulant thickness 25 – 44 mm)0.020 W/m.K (insulant thickness ≥ 45 mm)
Upper Facing Glass tissueCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)Exposed Facing Composite foil
Board Size 1.2 x 2.4 mThicknesses Available 25 – 140 mmComplementary Products
Floor
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
3
TF70INSULATION FOR SOLID CONCRETE AND SUSPENDED GROUND FLOORSRecommended for:✔ Below the floor slab / screed✔ Beam and block floors✔ Domestic floating floors✔ Suspended timber floors✔ Underfloor heating applications✔ Floor perimeter insulation✔ New build✔ Refurbishment
Kingspan Kooltherm® K8 Cavity Board
Kingspan Thermafloor® TF70
Product DataThermal Conductivity 0.022 W/m.KFacings Composite foilCore High performance rigid thermoset polyisocyanurate (PIR) insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Board Size 1.2 x 2.4 mThicknesses Available 20 – 150 mmComplementary Products
Floor
Visit www.kingspaninsulation.co.uk to download the full product brochure,
3
TF73INSULATION FOR FLOATING AND SUSPENDED GROUND FLOORSRecommended for:✔ Solid floating ground floors✔ Beam and block floors✔ Suspended timber floors✔ Areas where high
compressive strength required
✔ New build✔ Refurbishment
Kingspan Kooltherm® K8 Cavity Board
Kingspan Thermafloor® TF73
Product DataThermal Conductivity 1.29 W/m.K (insulant thickness 20 – 70 mm)
1.30 W/m.K (insulant thickness 70 – 120 mm)0.150 W/m.K (chipboard)
Upper Facing FSC certified 18 mm T&G chipboardCore High performance rigid extruded polystyrene insulant manufactured
with a blowing agent that has zero Ozone Depletion Potential (ODP)Board Size 2.4 x 0.6 mThicknesses Available 25 – 80 mm (Insulation thickness only)Complementary Products
Floor
Kingspan Kooltherm® K18 Insulated Plasterboard40
Cavity Closers
Cavity
4
Cavity CloserFOR CLOSING CAVITIES AROUND OPENINGS IN MASONRY WALLSRecommended for:✔ Traditional cavity wall construction✔ Window and door cavities✔ Use with PVCu and
wooden frames✔ Simplified construction✔ Cavity widths up to 305 mm✔ Using as a frame
former (Kooltherm®
Cavity Closer PLUS only)
Kingspan Kooltherm® Cavity Closer
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.022 W/m.KSheathing PVC–U extrusionCore Premium performance rigid thermoset modified resin insulant
manufactured with a blowing agent that has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP)
Length 2.4 mWidths Available 50 – 150 mm (or combinations up to 305 mm)Complementary Products • Kooltherm® K8 Cavity Board (page 27)
• Thermawall® TW50 (page 32)• Kooltherm® K17 Insulated Plasterboard (page 30)• Kooltherm® K18 Insulated Plasterboard (page 31)
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Cavity
4
Kingspan Kooltherm® Cavity Closer 50
For cavities 50 – 74 mm wideKingspan Kooltherm® Cavity
Closer 75For cavities 75 – 99 mm wide
Kingspan Kooltherm® Cavity Closer 100
For cavities 100 – 109 mm wide
128
128128
31.5
31.531.5
48 6
50 48
6
75
48 6
100
Kingspan Kooltherm® Cavity Closer 110
For cavities 110 – 124 mm wide
Kingspan Kooltherm® Cavity Closer 125
For cavities 125 – 149 mm wide
Kingspan Kooltherm® Cavity Closer 150
For cavities 150 – 155 mm wide
170
170170
31.5
31.531.5
48 6
110 125 48
6 150 48
6
Cavity CloserPRE–FORMED TO SPECIFIED OPENING SIZES FOR CLOSING CAVITIES IN PLASTIC, TIMBER, OR METAL WINDOW FRAMES AND AN INSULATED LINTEL
Cavity
4
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
4
FOR CLOSING CAVITIES AROUND OPENINGS IN MASONRY WALLSRecommended for:✔ Traditional cavity wall construction✔ Window and door cavities✔ Use with PVCu and
wooden frames✔ Simplified construction✔ Cavity widths up to 200 mm✔ Using as a frame
former (Thermabate PLUS only)
Kingspan Thermabate®
Kingspan Kooltherm® K8 Cavity Board
Product DataThermal Conductivity 0.034 W/m.KSheathing PVC–U extrusionCore High performance rigid thermoset urethane insulantLength 3.0 mWidths Available 50 – 100 mm*Complementary Products • Kooltherm® K8 Cavity Board (page 27)
• Thermawall® TW50 (page 32)• Kooltherm® K17 Insulated Plasterboard (page 30)• Kooltherm® K18 Insulated Plasterboard (page 31)
*Sections can be joined together to suit cavity widths up to 200 mm.
Visit www.kingspaninsulation.co.uk to download the full product brochure, order samples and learn about case studies
Cavity
4
Thermabate®
50(Brown)
Thermabate®
65(Black)
Thermabate®
75(White)
Thermabate®
85(Yellow)
Thermabate®
90(Orange)
Thermabate®
100(Green)
PRE–FORMED TO SPECIFIED OPENING SIZES FOR CLOSING CAVITIES IN PLASTIC, TIMBER, OR METAL WINDOW FRAMES AND AN INSULATED LINTEL
Cavity
4
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Breathable Membranes
Breathable
4
BREATHABLE MEMBRANE FOR UNVENTILATED PITCHED ROOFS AND TIMBER FRAME WALLSRecommended for:✔ All types of pitched roofing✔ Timber framing✔ Under battens or
directly on sarking boards
✔ New build✔ Re–roofing
Kingspan nilvent ®
Product DataWater Vapour Resistance 0.17 MN.s/gLiquid Water Penetration > 2 mTensile Strength 233 N longitudinal
162 N transverseRoll Length 50 mRoll Width 1.5 mThickness 0.5 mmArea Per Roll 75 m2
Complementary Products • Kooltherm® K7 Pitched Roof Board (page 10)• Kooltherm® K12 Framing Board (page 28)• Thermapitch® TP10 (page 11)• Thermawall® TW55 (page 33)
Visit www.kingspaninsulation.co.uk to download the full product brochure,
order samples and learn about case studies
Breathable
General EnquiriesTel: +44 (0) 1544 388 601Fax: +44 (0) 1544 388 888
email: [email protected]
Technical AdviceTel: +44 (0) 1544 387 382Fax: +44 (0) 1544 387 482
email: [email protected]
Tapered RoofingTel: +44 (0) 1544 387 383Fax: +44 (0) 1544 387 483
email: [email protected]
Literature and SamplesTel: +44 (0) 1544 387 384Fax: +44 (0) 1544 387 484
email: [email protected] Downloads:
www.kingspaninsulation.co.uk/literature
Customer ServiceTel: +44 (0) 1544 388 601Fax: +44 (0) 1544 388 888
email: [email protected]
Kingspan Insulation LtdPembridge, Leominster, Herefordshire HR6 9LA, UK
www.kingspaninsulation.co.uk
® Kingspan, Kooltherm, nilvent, Styrozone, Thermafloor, Thermaroof, Thermawall, Thermapitch, Thermataper,the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in the UK Ireland and other countries. All rights reserved. Kingspan Insulation Ltd. Registered in England & Wales, No. 01882722. Registered Office:
Pembridge, Leominster, Herefordshire HR6 9LA UK.