Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31...

15
Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors

Transcript of Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31...

Page 1: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Jim MunroManaging Director,Jim Munro International Compliance Pty LtdChairman, IEC Committee TC31Chairman, IECEx Panel of Assessors

Page 2: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Hazardous area equipment =Hazloc equipment =Explosion-protected equipment=Ex equipment

Page 3: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

International standardsGlobal certification schemesAustralian regulatory

requirements Missing links

Page 4: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Prime bodies for preparation of international standards are: International Electrotechnical

Commission (IEC) International Organisation for

Standardization (ISO) Committee tasked with Ex

standards: IEC Committee TC 31

Equipment for explosive atmospheres

Page 5: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Jim Munro International Compliance Pty Ltd

Page 6: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

About 50 standards in all covering:Equipment explosion protection

technique design standardsA few product standards Area classificationElectrical installations design,

selection and erection Inspection and maintenanceRepair and overhaul

Page 7: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Certification and approval systems that have acceptance outside individual countries include:

Europe - ATEX (which is an approval scheme)

North America - OSHA NRTL program

Australian and New Zealand - ANZEx Scheme

Page 8: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

There is only global Ex certification system – the IECEx System

Page 9: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

The IECEx System comprises the following The IECEx Certified Equipment

Scheme The IECEx Certified Service Facilities

Scheme The IECEx Conformity Mark

Licensing System The IECEx Certified Persons Scheme

Page 10: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Italy

India

Japan

Korea, Republic of

Malaysia

Netherlands

Norway

New Zealand

Poland

Romania

Russian Federation

Singapore

Slovenia

South Africa

Sweden

Switzerland

Turkey

United Kingdom

United States of America

Serbia & Montenegro

Australia

Brazil

Canada

China

Croatia

Czech Republic

Denmark

Finland

France

Germany

Hungary

Page 11: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

RUSSIA *NANIO-CCVE

SINGAPORE*TÜV SÜD PSB SLOVENIA *SIQ

SWEDEN*SP

UNITED KINGDOM*Baseefa*ITS *SIRA Cert*FM UK

UNITED STATES*UL

*FM

GERMANY*PTB *DEKRA/EXAM *TUV Nord*TUV Rheinland*TUV SÜD PS*IBExU*Zelm

HUNGARY* BKI

ITALY * CESI

KOREA*KOSHA *KGS *KTL

NETHERLANDS *KEMA

NORWAY *DNV*NEMKO

AUSTRALIA* ITACS *SIMTARS *TestSafe

CANADA* CSA International

*QPS

CZECH Republic*FTZU

CHINA*CQM

DENMARK*UL Int./ DEMKO A/S

FINLAND*VTT

FRANCE*LCIE*INERIS

Page 12: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

There are two major regulatory frameworks in Australia:

Those for coal mining; and Those for other industries

Page 13: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

Regulatory approachCoal mining – through specific

state legislationOther industries – through state

legislation calling out up the Wiring Rules (AS/NZS 3000) which in turn references relevant Ex standards

IECEx certificates can be used direct to market in Australia

Page 14: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

NON-ELECTRICAL EQUIPMENT Current standards

Few international standards Issues with CEN standards Some requirements in Australia for

coal mining - not much for other areas

Page 15: Jim Munro Managing Director, Jim Munro International Compliance Pty Ltd Chairman, IEC Committee TC31 Chairman, IECEx Panel of Assessors.

NON-ELECTRICAL EQUIPMENT The future

Recent formation within TC 31 of SC 31M Non-Electrical Equipment and Protective Systems for Explosive Atmospheres