Jet Validation of Fast simulation

19
Jet Validation of Fast simulation Kittikul Kovitanggoon*, Chiyoung Jeog, Sung-Won Lee Texas Tech University 1

description

Jet Validation of Fast simulation. Kittikul Kovitanggoon *, Chiyoung Jeog, Sung-Won Lee Texas Tech University. 1. Jet Collections with Algorithms. Icone5 Calo Jets Icone5 Pflow Kt4 Calo Jets Kt6 Calo Jets AntiKt5 Calo Jets AntiKt5 JPT AntiKt5 PFlow AntiKt7 Calo Jets. 2. - PowerPoint PPT Presentation

Transcript of Jet Validation of Fast simulation

Page 1: Jet Validation of Fast simulation

Jet Validationof

Fast simulation

Kittikul Kovitanggoon*, Chiyoung Jeog, Sung-Won LeeTexas Tech University

1

Page 2: Jet Validation of Fast simulation

Jet Collections with Algorithms

• Icone5 Calo Jets• Icone5 Pflow• Kt4 Calo Jets• Kt6 Calo Jets• AntiKt5 Calo Jets• AntiKt5 JPT• AntiKt5 PFlow• AntiKt7 Calo Jets

2

Page 3: Jet Validation of Fast simulation

3

Validation Procedures• After the MC RelVals for new version of CMSSW are

released and posted on HN.• We pick up the jet datasets like QCD and TTbar to be

run on our validation module.• We compare the histograms between new version

and previous version.• If no discrepancy is indicated, we report this version

pass.• If discrepancy is indicated, we ask the experts what

causes this discrepancy.• The validation result can be found at

http://highenergy.phys.ttu.edu/~keng/validation

Page 4: Jet Validation of Fast simulation

Status and Update• Status of moving to central DQM

- Jet validation module was tested with DQM sequence.

• Update new features - Reduced the bin size and remove unnecessary

plots.

- pT scale Vs Phi - pT response

4

Page 5: Jet Validation of Fast simulation

Histograms Jet pT scale Vs Phi

The black dot histogram is for new release.Red line filled histogram is for reference.

5

Page 6: Jet Validation of Fast simulation

Histograms pT respones

The black dot histogram is for new release.Red line filled histogram is for reference.

6

pT Response = Corrected pT/Gen pT

Page 7: Jet Validation of Fast simulation

Jet Validation in Spring 2011CMSSW Release Validation status

4_2_0_pre7 PassImproper HO status in DB

3_9_9_64bit wrt 32 bit Pass

3_9_9_64bit Pass

3_11_2 Pass

3_11_3 Pass

4_1_2 Pass

4_2_0_pre8 PassJet pt scale changes

7

Page 8: Jet Validation of Fast simulation

Jet Validation in Spring 2011CMSSW Release Validation status

Detector failure studies Reported to experts

4_2_0 Pass4_1_3 Pass4_2_1 Pass

The global tag need to be updated

inTime PU only and OOT PU Reported to experts

4_1_4 PassJEC closure improvement

4_1_5 Pass

8

Page 9: Jet Validation of Fast simulation

4_2_0_ pre7

9

• In this release: Had energy missing in fullsim and changing in fastsim

• Improper HO status in DB, which prevents HO from being properly used in MC CaloTowers (fix already submitted to the next pre-release GloblTag).

FullSim FastSim

Page 10: Jet Validation of Fast simulation

4_2_0_ pre8

10

• In this release: Jet pt scale in 1.3<|eta|<3.0 changes in fastsim

• The change is for better agreement with FullSim than 420pre7

wrt 4_2_0 pre7 wrt full

Page 11: Jet Validation of Fast simulation

4_2_1

11

• In this release: the recent global tag picks the old JEC

• Waiting for the new global tag for 42X and above

Page 12: Jet Validation of Fast simulation

4_1_4

12

• In this release: Discrepancies are found in the JEC (both pT ratio and pT response)

• This is the JEC closure improvement. The new JEC is applied.

Page 13: Jet Validation of Fast simulation

13

JetMET Data validationWe currently look at DQM plots created centrally and posted on DQM GUI

• This validation using RelVal_run2010B dataset (previous valskim) for this validation• We do this validation for every new CMSSW version after MC RelVal validation

The black line histogram is for new release.The filled histogram is for reference.

Page 14: Jet Validation of Fast simulation

JetMET Data validation

14

CMSSW Release Validation status

3_11_3 Pass

4_2_0 Pass

4_2_1 Pass

Page 15: Jet Validation of Fast simulation

Conclusion and Plans

• Jet Validation is moving smoothly.• We have the JEC checked in DQM.• Waiting for the new global tags for 42X and

above with the proper JEC.• The new tag for validation module will be

submitted to CVS.

15

Page 16: Jet Validation of Fast simulation

Back up

Page 17: Jet Validation of Fast simulation

Jet Collections

17

Page 18: Jet Validation of Fast simulation

Types Histograms

General parameters of jets

Energy, Momentum, and pT

Mass

Eta and Phi

Number of Calo towers

pT scale wrt eta

pT scale wrt pT

pT

pT ratio wrt eta

pT ratio wrt pT

EB and EE

HF

EM energy fraction of jets

18

Histograms to Validate

Page 19: Jet Validation of Fast simulation

Types Histograms

HAD Energy HB and HE

HO and HF

HAD energy fraction of jets

Long

Short

Leading jet energy, pT, eta, and phi

Had and EM timing

pT, pThat, Eta, and Phi

Leading jet Eta and Phi

19

Histograms to Validate