PRODUCT DESCRIPTION
JAMProSystem
Issue/Rev. Date: January 2006
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 2/12
Publisher: Weatherford Oil Tool GmbH
Hainhäuser Weg 150
D -30855 Langenhagen
++49 (0) 5 11 - 77 02 - 0
FAX ++49 (0) 5 11 - 77 02 - 187
Weatherford products and services are subject to Weatherford’s standard terms and conditions.
For more information concerning the full line of Weatherford products and services, please con-
tact your authorized Weatherford representative.
Unless noted otherwise, trademarks and service marks noted herein are the property of
Weatherford.
Due to possible design modifications, the description and technical data are subject to change
without prior notice.
This document is derived from the Operating Manual Section 'General Description'.
p/n: 561 5524 JAMPro V 1.2 Main Unit complete (Trolex)p/n: 561 5525 JAMPro V 1.2 Main Unit complete (Rota)p/n: 561 5526 JAMPro V 1.2 Trolex with Ethernet
p/n: 561 5530 External Unit: Tong Unit V1p/n: 561 5531 External Unit: Bargraph Unit V1p/n: 561 5532 External Unit: Graphic Display Unit V1
p/n: 561 5534 External Unit: HOLD & Print Unit
Copyright © 2006 by Weatherford Oil Tool GmbH/Germany
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 3/12
PRODUCT DESCRIPTION
1
J A M P r o S y s t e m
J A M P r o S y s t e m
1 GENERAL DESCRIPTION
JAMPro is a measuring computer system specially designed to control a power tong while making
up tubular connections in the oilfield. JAMPro consists of a Main Unit acting as the host and lo-cated on the rig floor, and an External Unit acting as a user panel at the tong.
At the Main Unit, the JAMPro operator adjusts the system, records the data and decides on
whether or not to accept the connection just made up. Furthermore, the data gathered by the
JAMPro System can be analysed and further commented on, statistics can be generated and, as
an option, data from leak detectors can be processed.
The Main Unit contains most of the electronic components. It is based on an industrial PC and
forms the heart of the system. It also contains all the parts used for the measuring functions and
the interfaces to the External Unit. This housing is designed Ex proof by using purging technol-ogy, while the in/outputs are designed intrinsically safe, except for the mains power supply 115 /
230 V AC.
An Ex proofed Ethernet connection is available as an option.
The External Unit of the Weatherford JAMPro System is located at the tong. It acts as an interface
between the Main Unit and the tong accessories, i.e. load cell, turns sensor and dump valve as
well as the leak detection system. The External Unit is available in different functionalities, as Bar
Graph Display Unit, as Graphic Display Unit, etc. They are connected to the PC by a special Ex
proof CAN bus interface. Some keys allow the user to interact with the Main Unit and accept or
reject a make up, while the display gives information about the status of the make up and/or the
reached torque.
The JAMPro System is designed for operation by one or two persons. The JAMPro operator
watches and operates the Main Unit, while the tong operator at the tong operates the tong valves.
It is highly advisable that both persons have at least visual contact, because the JAMPro operator
makes the decision to accept or reject a connection. The tong operator then has to act accord-
ingly, i.e. make up a rejected connection once more.
The entire JAMPro System is designed Ex proof. It can therefore be used in oil field environments
including gas hazardous areas.
The JAMPro System can be fitted to any Weatherford tong and leak detection system. We rec-
ommend to consult Weatherford for specific advice on the tong model or leak detection system
you want to use the JAMPro System with.
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 4/12
PRODUCT DESCRIPTION
2
The Weatherford JAMPro System consists of the following components:
Main Unit
Hoses for purging the Main Unit Keyboard cable (1 m)
Sun cover
Mains cable (15 m)
Ground wire or earth cable (3 m)
Ethernet connection (optional)
1 or 2 External Units (second unit optional), each comprising:
Load Cell (optional)
Pickup turns sensor or JAMPro turns encoder (optional)
Cable (25 m) for sensor data, connecting Main Unit and External Unit
Cable for sensors (1.5 m) and valve control (7.5 m)
See Fig. 3-1 for an overview of the system. J A MP r o S y s t em
J A MP r o S
Fig. 3-1 JAMPro System Overview
The following subsections explain the components in detail.
optional 2nd
External Unit115/230 V AC
optional Ethernet connection
Sensor data
4 – 8.5 bar s t em
ExternalUnit
Turnssensor
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 5/12
PRODUCT DESCRIPTION
3
1.1 MAIN UNIT
The Main Unit is designed as purge-protected. Therefore it can be located even in areas with risk
of explosion. Usually, it is located away from the well center, but on the rig floor. The JAMPro
System is controlled from the Main Unit.
The Main Unit consists of an industrial PC with keyboard and finger mouse. Compressed air flow-
ing through the housing purges the Main Unit.
Calibration and configuration of the JAMPro System are carried out at the Main Unit. Details on
software and controls are included in the JAMPro Software Manual.
Fig. 3-2 JAMPro System Main Unit
optional Ethernetconnection
Sensor data
4 – 8.5 bar
115/230 VAC optional Sensor data
J A M P r o S y s t e m
J A M P r o S y s t e m
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 6/12
PRODUCT DESCRIPTION
4
1.2 EXTERNAL UNIT
The External Unit of the JAMPro System acts as an interface between the Main Unit and the tong
accessories, i.e. loadcell, turns sensor and dump valve. The External Unit is available in different
functionalities, as Bar Graph Display Unit, as Graphic Display Unit, etc. All versions of the Exter-
nal Unit are designed intrinsically safe. The External Unit is located on the tong. As an option, 2
Bar Graph Units can be connected to the same JAMPro Main Unit. Note that only one Graphic
Display Unit can be connected at any one time.
1.2.1 Bar Graph Display Unit
The Bar Graph Display Unit of the JAMPro System acts as an interface between the Main Unit
and the tong accessories, i.e. loadcell, turns sensor and dump valve. It contains a glass covered
LC display with bar graph and message string. The Bar Graph Display Unit is designed intrinsi-cally safe. It is installed on the tong.
The Bar Graph Display Unit is connected to the Main Unit via a 25 m cable (standard length). The
sensors are connected to the Bar Graph Unit. The sensor data are directly fed through to the
Main Unit, and the LC module receives data and power supply via Fieldbus.
Note that a second Bar Graph Unit can be connected to the system as an option.
Fig. 3-3 JAMPro System Bar Graph DisplayUnit
J A MP r o S y s t em
J A MP r o S
C/T
LC
DV
TNS
2 Function keys
s t em
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 7/12
PRODUCT DESCRIPTION
5
1.2.2 Graphic Display Unit
The Graphic Display Unit of the JAMPro System acts as an interface between the Main Unit and
the tong accessories, i.e. loadcell, turns sensor and dump valve. It contains a glass covered
large-scale graphic display (LC display). The Graphic Display Unit is designed intrinsically safe. It
is installed on the tong.
The Graphic Display Unit is connected to the Main Unit via a 25 m cable (standard length). The
sensors are connected to the Graphic Display Unit. The sensor data are directly fed through to
the Main Unit, and the LC module receives data and power supply via Fieldbus.
Fig. 3-4 JAMPro System Graphic Display Unit
J A M P r o S y s t e m
J A M P r o S y s t e m
1.2.3 HOLD & Print Unit
The HOLD & Print Unit of the JAMPro System provides 2 non-intrinsically safe serial interfaces,
driven via the intrinsically safe CANbus. The HOLD & Print Unit must not be located in the Ex
area. The unit is connected to the Main Unit via the CT cable. Its mains cable must be connected
to a suitable 115 V/230 V AC power supply.
Leak Detection Systems UL 100 and UL 200 as well as a serail printer can be connected to the
HOLD & Print Unit.
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 8/12
PRODUCT DESCRIPTION
6
J A MP r o S y s t em
J A MP r o S
s t em
1.3 OTHER COMPONENTS
Apart from the Main Unit and the External Unit, the JAMPro System comprises the turns counter,
the active loadcell and the hoses and cables for interconnection. If an in-line dump valve is to be
used, it also forms part of the JAMPro System.
An Ex proofed Ethernet connection is also available. The connector has the following Ex-proof
characteristic: Protection class: EEx de II C T6. It is allowed to use it in hazardous areas.
At tention: See the specif ic procedure for the Ethernet connection in Sect ion 1.4.
The turns counter can be one of 2 types:
The JAMPro turns encoder. It is located on top of the rotor and measures the pipe rotation by
means of a friction wheel touching the rotating pipe. This version detects the direction of therotation.
The pickup turns sensor. It is located inside the gear box of the tong. Rotation is detected by
means of a proximity switch. The direction of rotation is set by the JAMPro software.
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 9/12
PRODUCT DESCRIPTION
7
J A M P r o S y s t e m
J A M P r o S y s t e m
1.4 TECHNICAL DATA
1.4.1 Technical Specification
Main Unit Comments
Weight lbskg
11050
Dimensions Length inchmm
18.39467
Width inchmm
20.16512
Height inchmm
15.40391
Compressed air supply pressure bar 4 minimum
Purge flow rate l/min 225 maximum
Purging time sec 120 - 330
Temperature range °C°F
°C°F
-25 to +50-13 to +122
-30 to +70-22 to +158
Operation
Storage
Graphic Display Unit Comments
Weight lbs
kg
8.8
4
Dimensions Length Inchmm
12.6320
Width Inchmm
6.5165
Height Inchmm
9.2235
Temperature range °C°F
°C
°F
-25 to +70-13 to +158
-30 to +85
-22 to +185
Operation
Storage
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 10/12
PRODUCT DESCRIPTION
8
J A MP r o S y s t em
J A MP r o S
s t em
Bar Graph Display Unit Comments
Weight lbskg
8.84
Dimensions Length Inchmm
8.8224
Width Inchmm
8203
Height Inchmm
6151
Temperature range °C°F
°C°F
-25 to +60-13 to +140
-30 to +70-22 to +158
Operation
Storage
HOLD & Print Unit Comments
Weight lbskg
7.13.2
Dimensions Length Inchmm
4.9125
Width Inchmm
7.9200
Height Inchmm
9.4240
Temperature range °C°F
°C°F
-20 to +60-4 to +140
-20 to +60-4 to +140
Operation
Storage
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 11/12
PRODUCT DESCRIPTION
9
J A M P r o S y s t e m
J A M P r o S y s t e m
Ex-proof Characteristics:
General
Certification ATEX-type II 2 G
Protection class EEx p d ia [ia] IIB T4
Supply
Electrical supply 115 V or 230 V +/-10%, 50 – 60 Hz, approx. 150 W
Connection Connector at main unit
cable extension customized (rubber type or ar-mored)
Compressed air supply: 4 – 8.5 bar, fine-mesh filter and air dryer integrated
- Flushing phase 90 – 225 l/min; 450 l total
- Operation < 60 l/min
Do not change the preset settings of the purge controll er! See certificate in Section 8.
Al l inter faces are speci fied for protect ion c lass EEx [ ia] IIB. Complete Ex data are listed in the
approval certification, see Section 8.
Note the difference between JAMPro versions 1.1 and 1.2. You find the version of your JAM-
Pro System at the type plate on top of the Main Unit.
Sensor interface V1.1 Permitted electrical values
Turns sensor/counter U0 = 12 V; Ik =36 mA, linear, Lp = 5 mH, Cp = 1.4 µF
Loadcell U0 = 21 V; Ik = 86 mA, P0 = 711 mW, Lp = 5 mH, Cp = 220 nF
Sensor interface V1.2 Permitted electrical values
Turns counter U0 = 9.9 V; Ik =24 mA, P0 = 60 mW, Lp = 10 mH, Cp = 3.5 µF
Loadcell U0 = 20 V; Ik = 77 mA, P0 = 560 mW, Lp = 5 mH, Cp = 680 nF
Valve output Permitted electrical values
Dump valve U0 = 14.5 V; Ik = 164 mA, P0 = 1.28 W, Lp = 3 mH, Cp = 640 nF
Main Unit Personal Computer – Characteristics:
Celeron 560 MHz processor VGA and LCD
Operating System Windows NT(Windows 2000 optional)
Ethernet interface
64 MB SDRAM (128 MB optional) 2 x LPT interface (e.g. for floppy disk drive)
CANbus interface IDE interface (external, for CD-ROM)
4 x serial I/O
Technical specifications are subject to change without prior notice.
7/25/2019 Jampro System Description
http://slidepdf.com/reader/full/jampro-system-description 12/12
PRODUCT DESCRIPTION
10
J A MP r o S y s t em
J A MP r o S
s t em
Weatherford Oil Tool GmbHWeatherford products are subject to Weather-
ford’s standard terms and conditions. Unlessnoted otherwise, trademarks and servicemarks herein are property of Weatherford.Technical changes and misprints reserved.
Hainhäuser Weg 15030855 LangenhagenGermanyPhone ++49 511 7702-0Fax ++49 511 7702-187
© 2006 Weatherford. All rights reserved. E-mail: [email protected]